All of lore.kernel.org
 help / color / mirror / Atom feed
From: Henning Schild <henning.schild@siemens.com>
To: linux-kernel@vger.kernel.org, linux-leds@vger.kernel.org,
	platform-driver-x86@vger.kernel.org,
	linux-watchdog@vger.kernel.org
Cc: Srikanth Krishnakar <skrishnakar@gmail.com>,
	Jan Kiszka <jan.kiszka@siemens.com>,
	Henning Schild <henning.schild@siemens.com>,
	Gerd Haeussler <gerd.haeussler.ext@siemens.com>,
	Guenter Roeck <linux@roeck-us.net>,
	Wim Van Sebroeck <wim@linux-watchdog.org>,
	Mark Gross <mgross@linux.intel.com>,
	Hans de Goede <hdegoede@redhat.com>, Pavel Machek <pavel@ucw.cz>,
	Andy Shevchenko <andy.shevchenko@gmail.com>
Subject: [PATCH] platform/x86: pmc_atom: use callback for all dmi quirk entries
Date: Mon, 15 Mar 2021 15:58:55 +0100	[thread overview]
Message-ID: <20210315145855.17174-1-henning.schild@siemens.com> (raw)
In-Reply-To: <ef5fe493-285d-145c-8d05-7f9bd0cb47c5@redhat.com>

Introduce a global variable to remember the matching entry for later
printing. Also having a callback allows to stop matching after the first
hit.

Signed-off-by: Henning Schild <henning.schild@siemens.com>
---
 drivers/platform/x86/pmc_atom.c | 26 ++++++++++++++++++++------
 1 file changed, 20 insertions(+), 6 deletions(-)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index 38542d547f29..d0f74856cd8b 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -364,8 +364,16 @@ static void pmc_dbgfs_register(struct pmc_dev *pmc)
 #endif /* CONFIG_DEBUG_FS */
 
 static bool pmc_clk_is_critical = true;
+static const struct dmi_system_id *dmi_critical;
 
-static int siemens_clk_is_critical(const struct dmi_system_id *d)
+static int dmi_callback(const struct dmi_system_id *d)
+{
+	dmi_critical = d;
+
+	return 1;
+}
+
+static int dmi_callback_siemens(const struct dmi_system_id *d)
 {
 	u32 st_id;
 
@@ -373,7 +381,7 @@ static int siemens_clk_is_critical(const struct dmi_system_id *d)
 		goto out;
 
 	if (st_id == SIMATIC_IPC_IPC227E || st_id == SIMATIC_IPC_IPC277E)
-		return 1;
+		return dmi_callback(d);
 
 out:
 	pmc_clk_is_critical = false;
@@ -388,6 +396,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk0 is used for an external HSIC USB HUB */
 		.ident = "MPL CEC1x",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"),
@@ -396,6 +405,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */
 		.ident = "Lex 3I380D",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
@@ -404,6 +414,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Lex 2I385SW",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "2I385SW"),
@@ -412,6 +423,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB3163",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
@@ -420,6 +432,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB4063",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_BOARD_NAME, "CB4063"),
@@ -428,6 +441,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB6263",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
@@ -436,13 +450,14 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB6363",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
 		},
 	},
 	{
-		.callback = siemens_clk_is_critical,
+		.callback = dmi_callback_siemens,
 		.ident = "SIEMENS AG",
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
@@ -457,7 +472,6 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
 {
 	struct platform_device *clkdev;
 	struct pmc_clk_data *clk_data;
-	const struct dmi_system_id *d;
 
 	clk_data = kzalloc(sizeof(*clk_data), GFP_KERNEL);
 	if (!clk_data)
@@ -468,8 +482,8 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
 	if (dmi_check_system(critclk_systems)) {
 		clk_data->critical = pmc_clk_is_critical;
 		if (clk_data->critical) {
-			d = dmi_first_match(critclk_systems);
-			pr_info("%s critclks quirk enabled\n", d->ident);
+			pr_info("%s critclks quirk enabled\n",
+				dmi_critical->ident);
 		}
 	}
 
-- 
2.26.2


  parent reply	other threads:[~2021-03-15 15:00 UTC|newest]

Thread overview: 44+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-03-15  9:57 [PATCH v2 0/4] add device drivers for Siemens Industrial PCs Henning Schild
2021-03-15  9:57 ` [PATCH v2 1/4] platform/x86: simatic-ipc: add main driver for Siemens devices Henning Schild
2021-03-15 10:31   ` Andy Shevchenko
2021-03-15 16:30     ` Henning Schild
2021-03-17 19:13     ` Henning Schild
2021-03-17 20:03       ` Hans de Goede
2021-03-18 11:30         ` Enrico Weigelt, metux IT consult
2021-03-18 11:45           ` Hans de Goede
2021-03-26  9:55             ` Henning Schild
2021-03-26 12:21               ` Hans de Goede
2021-03-15  9:57 ` [PATCH v2 2/4] leds: simatic-ipc-leds: add new driver for Siemens Industial PCs Henning Schild
2021-03-15 10:48   ` Andy Shevchenko
2021-03-15 11:19     ` Pavel Machek
2021-03-15 11:26       ` Andy Shevchenko
2021-03-15 12:40       ` Henning Schild
2021-03-18 11:38       ` Enrico Weigelt, metux IT consult
2021-03-27  9:46         ` Henning Schild
2021-04-01 16:20           ` Enrico Weigelt, metux IT consult
2021-03-27  9:56       ` Henning Schild
2021-03-18 10:27     ` Enrico Weigelt, metux IT consult
2021-03-18 12:40       ` Alexander Dahl
2021-03-23 17:45         ` Henning Schild
2021-03-26 16:33     ` Henning Schild
2021-03-18 10:25   ` Enrico Weigelt, metux IT consult
2021-03-27 11:16     ` Henning Schild
2021-03-27 11:41       ` Henning Schild
2021-03-15  9:57 ` [PATCH v2 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs Henning Schild
2021-03-15 15:10   ` Guenter Roeck
2021-03-29 16:28     ` Henning Schild
2021-03-15  9:57 ` [PATCH v2 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs Henning Schild
2021-03-15 10:14   ` Henning Schild
2021-03-15 10:19     ` Hans de Goede
2021-03-15 12:09       ` Henning Schild
2021-03-15 14:58       ` Henning Schild [this message]
2021-03-15 16:31         ` [PATCH] platform/x86: pmc_atom: use callback for all dmi quirk entries Hans de Goede
2021-03-15 17:00           ` Henning Schild
2021-03-15 18:01             ` Hans de Goede
2021-03-16  5:47               ` Henning Schild
2021-03-16  9:43                 ` Hans de Goede
2021-03-15 13:25   ` [PATCH v2 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs kernel test robot
2021-03-15 13:25     ` kernel test robot
2021-03-15 10:55 ` [PATCH v2 0/4] add device drivers for Siemens Industrial PCs Andy Shevchenko
2021-03-15 16:08   ` Henning Schild
2021-08-02  9:21   ` Henning Schild

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20210315145855.17174-1-henning.schild@siemens.com \
    --to=henning.schild@siemens.com \
    --cc=andy.shevchenko@gmail.com \
    --cc=gerd.haeussler.ext@siemens.com \
    --cc=hdegoede@redhat.com \
    --cc=jan.kiszka@siemens.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-leds@vger.kernel.org \
    --cc=linux-watchdog@vger.kernel.org \
    --cc=linux@roeck-us.net \
    --cc=mgross@linux.intel.com \
    --cc=pavel@ucw.cz \
    --cc=platform-driver-x86@vger.kernel.org \
    --cc=skrishnakar@gmail.com \
    --cc=wim@linux-watchdog.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.