From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1755920Ab0FXWGK (ORCPT ); Thu, 24 Jun 2010 18:06:10 -0400 Received: from imr3.ericy.com ([198.24.6.13]:39699 "EHLO imr3.ericy.com" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1751760Ab0FXWGG (ORCPT ); Thu, 24 Jun 2010 18:06:06 -0400 From: Guenter Roeck To: Randy Dunlap , Jean Delvare , Andrew Morton , "Ira W. Snyder" , Hans de Goede , Mark Brown , Samuel Ortiz , Jonathan Cameron CC: lm-sensors@lm-sensors.org, linux-kernel@vger.kernel.org, linux-doc@vger.kernel.org, Guenter Roeck Subject: [PATCH v3 3/4] hwmon: Update sysfs-interface to include new attributes Date: Thu, 24 Jun 2010 15:01:00 -0700 Message-ID: <1277416861-32494-4-git-send-email-guenter.roeck@ericsson.com> X-Mailer: git-send-email 1.7.0.87.g0901d In-Reply-To: <1277416861-32494-1-git-send-email-guenter.roeck@ericsson.com> References: <1277416861-32494-1-git-send-email-guenter.roeck@ericsson.com> MIME-Version: 1.0 Content-Type: text/plain Sender: linux-kernel-owner@vger.kernel.org List-ID: X-Mailing-List: linux-kernel@vger.kernel.org Added _lcrit and _crit to voltage attributes. Added _lcrit to temperature attributes. Signed-off-by: Guenter Roeck --- Documentation/hwmon/sysfs-interface | 21 ++++++++++++++++++++- 1 files changed, 20 insertions(+), 1 deletions(-) diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface index d4e2917..7f60c0d 100644 --- a/Documentation/hwmon/sysfs-interface +++ b/Documentation/hwmon/sysfs-interface @@ -107,10 +107,24 @@ in[0-*]_min Voltage min value. Unit: millivolt RW +in[0-*]_lcrit Voltage critical min value. + Unit: millivolt + RW + If voltage drops to or below this limit, the system may + take drastic action such as power down or reset. At the very + least, it should report a fault. + in[0-*]_max Voltage max value. Unit: millivolt RW +in[0-*]_crit Voltage critical max value. + Unit: millivolt + RW + If voltage reaches or exceeds this limit, the system may + take drastic action such as power down or reset. At the very + least, it should report a fault. + in[0-*]_input Voltage input value. Unit: millivolt RO @@ -284,11 +298,16 @@ temp[1-*]_input Temperature input value. Unit: millidegree Celsius RO -temp[1-*]_crit Temperature critical value, typically greater than +temp[1-*]_crit Temperature critical max value, typically greater than corresponding temp_max values. Unit: millidegree Celsius RW +temp[1-*]_lcrit Temperature critical min value, typically lower than + corresponding temp_min values. + Unit: millidegree Celsius + RW + temp[1-*]_crit_hyst Temperature hysteresis value for critical limit. Unit: millidegree Celsius -- 1.7.0.87.g0901d From mboxrd@z Thu Jan 1 00:00:00 1970 From: Guenter Roeck Date: Thu, 24 Jun 2010 22:01:00 +0000 Subject: [lm-sensors] [PATCH v3 3/4] hwmon: Update sysfs-interface to Message-Id: <1277416861-32494-4-git-send-email-guenter.roeck@ericsson.com> List-Id: References: <1277416861-32494-1-git-send-email-guenter.roeck@ericsson.com> In-Reply-To: <1277416861-32494-1-git-send-email-guenter.roeck@ericsson.com> MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: Randy Dunlap , Jean Delvare , Andrew Morton , "Ira W. Snyder" , Hans de Goede , Mark Brown , Samuel Ortiz , Jonathan Cameron Cc: lm-sensors@lm-sensors.org, linux-kernel@vger.kernel.org, linux-doc@vger.kernel.org, Guenter Roeck Added _lcrit and _crit to voltage attributes. Added _lcrit to temperature attributes. Signed-off-by: Guenter Roeck --- Documentation/hwmon/sysfs-interface | 21 ++++++++++++++++++++- 1 files changed, 20 insertions(+), 1 deletions(-) diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface index d4e2917..7f60c0d 100644 --- a/Documentation/hwmon/sysfs-interface +++ b/Documentation/hwmon/sysfs-interface @@ -107,10 +107,24 @@ in[0-*]_min Voltage min value. Unit: millivolt RW +in[0-*]_lcrit Voltage critical min value. + Unit: millivolt + RW + If voltage drops to or below this limit, the system may + take drastic action such as power down or reset. At the very + least, it should report a fault. + in[0-*]_max Voltage max value. Unit: millivolt RW +in[0-*]_crit Voltage critical max value. + Unit: millivolt + RW + If voltage reaches or exceeds this limit, the system may + take drastic action such as power down or reset. At the very + least, it should report a fault. + in[0-*]_input Voltage input value. Unit: millivolt RO @@ -284,11 +298,16 @@ temp[1-*]_input Temperature input value. Unit: millidegree Celsius RO -temp[1-*]_crit Temperature critical value, typically greater than +temp[1-*]_crit Temperature critical max value, typically greater than corresponding temp_max values. Unit: millidegree Celsius RW +temp[1-*]_lcrit Temperature critical min value, typically lower than + corresponding temp_min values. + Unit: millidegree Celsius + RW + temp[1-*]_crit_hyst Temperature hysteresis value for critical limit. Unit: millidegree Celsius -- 1.7.0.87.g0901d _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors