From mboxrd@z Thu Jan 1 00:00:00 1970 From: Guenter Roeck Date: Sun, 06 Feb 2011 16:13:02 +0000 Subject: Re: [lm-sensors] Standalone driver for W83677HG-I, NCT6775F, Message-Id: <20110206161302.GB30271@ericsson.com> List-Id: References: <20110205175852.GA26672@ericsson.com> In-Reply-To: <20110205175852.GA26672@ericsson.com> MIME-Version: 1.0 Content-Type: text/plain; charset="utf-8" Content-Transfer-Encoding: 8bit To: lm-sensors@vger.kernel.org Hi Ian, On Sun, Feb 06, 2011 at 04:36:10AM -0500, Ian Dobson wrote: [ ... ] > >> temp2: -60.0°C (high = +50.0°C, hyst = +55.0°C) sensor = diode > > > > This doesn't look good either. Can you report the raw values you get when > > reading > > registers 0x150/0x151, 0x75/0x76, 0x152, and 0x200 ? > > > > I have been wondering if I should retrieve the temperature values from > > 0x73/0x75/0x77. > > This is another set of temperature registers supported by both chips and > > used as > > fan monitoring source. 0x150 and 0x200 specify the temperature source for > > 0x151 and > > 0x75, respectively. > > > > Thanks, > > Guenter > > 0x150 = 0 > 0x151 = 0 > 0x075 = 31 > 0x076 = 0 > 0x152 = 0 > 0x200 = c > Looks like they are using PECI agent 0 as monitoring source. Odd, though, that 0x150 reads zero but reports -60 degrees C. Is that fluctuating ? Also, can you dump registers 0x100, 0x200, 0x300, and 0x621 to 0x626 ? Those registers define the mapping from temperature sources to registers (0x152 was wrong; should have said 0x622). Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors