From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1755387Ab3FDXP7 (ORCPT ); Tue, 4 Jun 2013 19:15:59 -0400 Received: from 1wt.eu ([62.212.114.60]:35412 "EHLO 1wt.eu" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1752907Ab3FDWmP (ORCPT ); Tue, 4 Jun 2013 18:42:15 -0400 Message-Id: <20130604172133.083450535@1wt.eu> User-Agent: quilt/0.48-1 Date: Tue, 04 Jun 2013 19:22:37 +0200 From: Willy Tarreau To: linux-kernel@vger.kernel.org, stable@vger.kernel.org Cc: Ian Abbott , Willy Tarreau Subject: [ 067/184] staging: comedi: ni_labpc: correct differential In-Reply-To: <58df134a4b98edf5b0073e2e1e988fe6@local> Sender: linux-kernel-owner@vger.kernel.org List-ID: X-Mailing-List: linux-kernel@vger.kernel.org 2.6.32-longterm review patch. If anyone has any objections, please let me know. ------------------ channel sequence for AI commands From: Ian Abbott Commit 4c4bc25d0fa6beaf054c0b4c3b324487f266c820 upstream. Tuomas reported problems getting meaningful output from a Lab-PC+ in differential mode for AI cmds, but AI insn reads gave correct readings. He tracked it down to two problems, one of which is addressed by this patch. It seems the setting of the channel bits for particular scanning modes was incorrect for differential mode. (Only half the number of channels are available in differential mode; comedi refers to them as channels 0, 1, 2 and 3, but the hardware documentation refers to them as channels 0, 2, 4 and 6.) In differential mode, the setting of the channel enable bits in the command1 register should depend on whether the scan enable bit is set. Effectively, we need to double the comedi channel number when the scan enable bit is not set in differential mode. The scan enable bit gets set when the AI scan mode is `MODE_MULT_CHAN_UP` or `MODE_MULT_CHAN_DOWN`, and gets cleared when the AI scan mode is `MODE_SINGLE_CHAN` or `MODE_SINGLE_CHAN_INTERVAL`. The existing test for whether the comedi channel number needs to be doubled in differential mode is incorrect in `labpc_ai_cmd()`. This patch corrects the test. Thanks to Tuomas for suggesting the fix. Signed-off-by: Ian Abbott Signed-off-by: Willy Tarreau --- drivers/staging/comedi/drivers/ni_labpc.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/drivers/staging/comedi/drivers/ni_labpc.c b/drivers/staging/comedi/drivers/ni_labpc.c index 4ac745a..eada2ce 100644 --- a/drivers/staging/comedi/drivers/ni_labpc.c +++ b/drivers/staging/comedi/drivers/ni_labpc.c @@ -1178,7 +1178,9 @@ static int labpc_ai_cmd(struct comedi_device *dev, struct comedi_subdevice *s) else channel = CR_CHAN(cmd->chanlist[0]); /* munge channel bits for differential / scan disabled mode */ - if (labpc_ai_scan_mode(cmd) != MODE_SINGLE_CHAN && aref == AREF_DIFF) + if ((labpc_ai_scan_mode(cmd) == MODE_SINGLE_CHAN || + labpc_ai_scan_mode(cmd) == MODE_SINGLE_CHAN_INTERVAL) && + aref == AREF_DIFF) channel *= 2; devpriv->command1_bits |= ADC_CHAN_BITS(channel); devpriv->command1_bits |= thisboard->ai_range_code[range]; -- 1.7.12.2.21.g234cd45.dirty