Hi, On Tue, Jan 24, 2017 at 10:32:23AM +0800, Chen-Yu Tsai wrote: > On the Allwinner A80 SoC, the PLL lock status indicators are grouped > together in a separate register, as opposed to being scattered in each > PLL's configuration register. > > Add a flag to support this. > > Signed-off-by: Chen-Yu Tsai > --- > drivers/clk/sunxi-ng/ccu_common.c | 8 ++++++-- > drivers/clk/sunxi-ng/ccu_common.h | 2 ++ > 2 files changed, 8 insertions(+), 2 deletions(-) > > diff --git a/drivers/clk/sunxi-ng/ccu_common.c b/drivers/clk/sunxi-ng/ccu_common.c > index 51d4bac97ab3..3fd0c3331aff 100644 > --- a/drivers/clk/sunxi-ng/ccu_common.c > +++ b/drivers/clk/sunxi-ng/ccu_common.c > @@ -25,13 +25,17 @@ static DEFINE_SPINLOCK(ccu_lock); > > void ccu_helper_wait_for_lock(struct ccu_common *common, u32 lock) > { > + void __iomem *addr; > u32 reg; > > if (!lock) > return; > > - WARN_ON(readl_relaxed_poll_timeout(common->base + common->reg, reg, > - reg & lock, 100, 70000)); > + addr = common->base + common->reg; > + if (common->features & CCU_FEATURE_LOCK_REG) > + addr = common->base + common->lock_reg; I'd rather have an else here (but it's really just a nitpick). Thanks, Maxime -- Maxime Ripard, Free Electrons Embedded Linux and Kernel engineering http://free-electrons.com