From mboxrd@z Thu Jan 1 00:00:00 1970 Return-path: Received: from mx4.wp.pl ([212.77.101.11]:16982 "EHLO mx4.wp.pl" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1752481AbeDPRZA (ORCPT ); Mon, 16 Apr 2018 13:25:00 -0400 Date: Mon, 16 Apr 2018 10:24:52 -0700 From: Jakub Kicinski To: Stanislaw Gruszka Cc: linux-wireless@vger.kernel.org Subject: Re: [PATCH 2/2 v2] mt7601u: run calibration works after finishing scanning Message-ID: <20180416102452.09f0a9bc@cakuba.netronome.com> (sfid-20180416_192503_829874_D1979EEA) In-Reply-To: <1523879778-6455-2-git-send-email-sgruszka@redhat.com> References: <1523879778-6455-1-git-send-email-sgruszka@redhat.com> <1523879778-6455-2-git-send-email-sgruszka@redhat.com> MIME-Version: 1.0 Content-Type: text/plain; charset=US-ASCII Sender: linux-wireless-owner@vger.kernel.org List-ID: On Mon, 16 Apr 2018 13:56:18 +0200, Stanislaw Gruszka wrote: > When finishing scanning we switch to operational channel sill with > SCANNING flag. This mean that we never perform calibration works after > scanning. To fix the problem queue calibration works on > .sw_scan_complete() routine. > > Signed-off-by: Stanislaw Gruszka Acked-by: Jakub Kicinski Thank you!!