From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Return-path: Date: Fri, 29 Jun 2018 09:21:56 +0200 From: Andrew Lunn To: Guenter Roeck Cc: netdev , Florian Fainelli , Russell King , vadimp@mellanox.com, linux-hwmon@vger.kernel.org Subject: Re: [PATCH RFC 1/2] hwmon: Add support for power min, lcrit, min_alarm and lcrit_alarm Message-ID: <20180629072156.GA11285@lunn.ch> References: <1530218475-4369-1-git-send-email-andrew@lunn.ch> <1530218475-4369-2-git-send-email-andrew@lunn.ch> <20180628224236.GB20118@roeck-us.net> MIME-Version: 1.0 Content-Type: text/plain; charset=us-ascii Content-Disposition: inline In-Reply-To: <20180628224236.GB20118@roeck-us.net> List-ID: On Thu, Jun 28, 2018 at 03:42:36PM -0700, Guenter Roeck wrote: > On Thu, Jun 28, 2018 at 10:41:14PM +0200, Andrew Lunn wrote: > > Some sensors support reporting minimal and lower critical power, as > > well as alarms when these thresholds are reached. Add support for > > these attributes to the hwmon core. > > > > Signed-off-by: Andrew Lunn > > I am inclined to accept this patch immediately. I'll do that > in the next couple of days unless someone gives me a good reason > not to. Hi Guenter We need to watch out for merge dependencies. If you take it, you probably should also take the second patch into your tree as well. Otherwise, you need a stable branch DaveM can pull into net-next if he takes the second patch. I also have a patch to lm-sensors sensors, so it prints these values. I will create a github pull request. Andrew