Subject: [PATCH v4 01/34] Add Vision Processing Unit (VPU) documentation.
Date: Fri, 29 Jan 2021 18:20:51 -0800	[thread overview]
Message-ID: <20210130022124.65083-37-mgross@linux.intel.com> (raw)
In-Reply-To: <20210130022124.65083-1-mgross@linux.intel.com>

From: mark gross <mgross@linux.intel.com>

The Intel VPU needs a complicated SW stack to make it work.  Add a
directory to hold VPU related documentation including an architectural
overview of the SW stack that the patches implement.

Cc: Jonathan Corbet <corbet@lwn.net>
Signed-off-by: Mark Gross <mgross@linux.intel.com>
---
 Documentation/index.rst                  |   1 +
 Documentation/vpu/index.rst              |  16 ++
 Documentation/vpu/vpu-stack-overview.rst | 270 +++++++++++++++++++++++
 3 files changed, 287 insertions(+)
 create mode 100644 Documentation/vpu/index.rst
 create mode 100644 Documentation/vpu/vpu-stack-overview.rst

diff --git a/Documentation/index.rst b/Documentation/index.rst
index 5888e8a7272f..81a02f2af939 100644
--- a/Documentation/index.rst
+++ b/Documentation/index.rst
@@ -137,6 +137,7 @@ needed).
    misc-devices/index
    scheduler/index
    mhi/index
+   vpu/index
 
 Architecture-agnostic documentation
 -----------------------------------
diff --git a/Documentation/vpu/index.rst b/Documentation/vpu/index.rst
new file mode 100644
index 000000000000..7e290e048910
--- /dev/null
+++ b/Documentation/vpu/index.rst
@@ -0,0 +1,16 @@
+.. SPDX-License-Identifier: GPL-2.0-only
+
+============================================
+Vision Processor Unit Documentation
+============================================
+
+This documentation contains information for the Intel VPU stack.
+
+.. class:: toc-title
+
+	   Table of contents
+
+.. toctree::
+   :maxdepth: 2
+
+   vpu-stack-overview
diff --git a/Documentation/vpu/vpu-stack-overview.rst b/Documentation/vpu/vpu-stack-overview.rst
new file mode 100644
index 000000000000..1fe9ce423177
--- /dev/null
+++ b/Documentation/vpu/vpu-stack-overview.rst
@@ -0,0 +1,270 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+======================
+Intel VPU architecture
+======================
+
+Overview
+========
+
+The Intel Movidius acquisition has developed a Vision Processing Unit (VPU)
+roadmap of products starting with Keem Bay (KMB). The hardware configurations
+the VPU can support include:
+
+1. Standalone smart camera that does local Computer Vision (CV) processing in
+   camera
+2. Standalone appliance or signel board computer connected to a network and
+   tethered cameras doing local CV processing
+3. Embedded in a USB dongle or M.2 as an CV accelerator.
+4. Multiple VPU enabled SOC's on a PCIe card as a CV accelerator in a larger IA
+   box or server.
+
+Keem Bay is the first instance of this family of products. This document
+provides an architectural overview of the software stack supporting the VPU
+enabled products.
+
+Keem Bay (KMB) is a Computer Vision AI processing SoC based on ARM A53 CPU that
+provides Edge neural network acceleration (inference) and includes a Vision
+Processing Unit (VPU) hardware. The ARM CPU SubSystem (CPUSS) interfaces
+locally to the VPU and enables integration/interfacing with a remote host over
+PCIe or USB or Ethernet interfaces. The interface between the CPUSS and the VPU
+is implemented with hardware FIFOs (Control) and coherent memory mapping (Data)
+such that zero copy processing can happen within the VPU.
+
+The KMB can be used in all 4 of the above classes of designs.
+
+We refer to the 'local host' as being the ARM part of the SoC, while the
+'remote host' as the IA system hosting the KMB device(s). The KMB SoC boots
+from an eMMC via uBoot and ARM Linux compatible device tree interface with an
+expectation to fully boot within hundreds of milliseconds. There is also
+support for downloading the kernel and root file system image from a remote
+host.
+
+The eMMC can be updated with standard Mender update process.
+See https://github.com/mendersoftware/mender
+
+The VPU is started and controlled from the A53 local host. Its firmware image
+is loaded using the drive firware helper KAPI's.
+
+The VPU IP firware payload consists of a SPARC ISA RTEMS bootloader and/or
+application binary.
+
+The interface allowing (remote or local) host clients to access VPU IP
+capabilities is realized through an abstracted programming model, which
+provides Remote Proxy APIs for a host CPU application to dynamically create and
+execute CV and NN workloads on the VPU. All frameworks exposed through
+programming model’s APIs are contained in the pre-compiled standard firmware
+image.
+
+There is a significant software stack built up to support KMB and the use
+cases. The rest of this documentation provides an overview of the components
+of the stack.
+
+Keem Bay IPC
+============
+
+Directly interfaces with the KMB hardware FIFOs to provide zero copy processing
+from the VPU. It implements the lowest level protocol for interacting with the
+VPU.
+
+The Keem Bay IPC mechanism is based on shared memory and hardware FIFOs.
+Specifically there are:
+
+* Two 128-entry hardware FIFOs, one for the CPU and one for the VPU.
+* Two shared memory regions, used as memory pool for allocating IPC buffers.
+
+An IPC channel is a software abstraction allowing communication multiplexing,
+so that multiple applications / users can concurrently communicate with the
+VPU.  IPC channels area conceptually similar to socket ports.
+
+There are a total of 1024 channels, each one identified by a channel ID,
+ranging from 0 to 1023.
+
+Channels are divided in two categories:
+
+* High-Speed (HS) channels, having IDs in the 0-9 range.
+* General-Purpose (GP) channels, having IDs in the 10-1023 range.
+
+HS channels have higher priority over GP channels and can be used by
+applications requiring higher throughput or lower latency.
+
+Since all the channels share the same hardare resources (i.e., the hardware
+FIFOs and the IPC memory pools), the Keem Bay IPC driver uses software queues
+to give a higher priority to HS channels.
+
+The driver supports a build-time configurable number of communication channels
+defined in a so-called Channel Mapping Table.
+
+An IPC channel is full duplex: a pending operation from a certain channel does
+not block other operations on the same channel, regardless of their operation
+mode (blocking or non-blocking).
+
+Operation mode is individually selectable for each channel, per operation
+direction (read or write). All operations for that direction comply to
+selection.
+
+
+Keem Bay-VPU-IPC
+================
+
+This is the MMIO driver of the VPU IP block inside the SOC. It is a control
+driver mapping IPC channel communication to Xlink virtual channels.
+
+This driver provides the following functionality to other drivers in the
+communication stack:
+
+* VPU IP execution control (firmware load, start, reset)
+* VPU IP event notifications (device connected, device disconnected, WDT event)
+* VPU IP device status query (OFF, BUSY, READY, ERROR, RECOVERY)
+* Communication via the IPC protocol (wrapping the Keem Bay IPC driver and
+  exposing it to higher level Xlink layer)
+
+In addition to the above, the driver exposes SoC information (like stepping,
+device ID, etc.) to user-space via sysfs.
+
+This driver depends on the 'Keem Bay IPC' driver, which enables the Keem Bay
+IPC communication protocol.
+
+The driver uses the Firmware API to load the VPU firmware from user-space.
+
+Xlink-IPC
+=========
+This component implements the IPC specific Xlink protocol. It maps channel
+IDs to hardware FIFO entries, using the Keem Bay VPU IPC driver.
+
+Some of the main functions this driver provides:
+
+* establishing a connection with an IPC device
+* obtaining a list with the available devices
+* obtaining the status for a device
+* booting a device
+* resetting a device
+* opening and closing channels
+* issuing read and write operations
+
+Xlink-core
+==========
+
+This component implements an abstracted set of control and communication APIs
+based on channel identification. It is intended to support VPU technology both
+at SoC level as well as at IP level, over multiple interfaces.
+
+It provides symmetrical services, where the producer and the consumer have
+the same privileges.
+
+Xlink driver has the ability to abstract several types of communication
+channels underneath, allowing the usage of different interfaces with the same
+function calls.
+
+Xlink services are available to both kernel and user space clients and include:
+
+* interface abstract control and communication API
+* multi device support
+* concurrent communication across 4096 communication channels (from 0 to
+  0xFFF), with customizable properties
+* full duplex channels with multiprocess and multithread support
+* channel IDs can be mapped to desired physical interface (PCIe, USB, ETH, IPC)
+  via a Channel Mapping Table
+* asynchronous fast passthrough mode: remote host data packets are directly
+  dispatched using interrupt systems running on local host to IPC calls for low
+  overhead
+* channel handshaking mechanism for peer to peer communication, without the
+  need of static channel preallocation
+* channel resource management
+* asynchronous data and device notifications to subscribers
+
+Xlink transports: PCIe, USB, ETH, IPC, XLink-PCIe
+
+XLink-PCIe
+==========
+This is an endpoint driver that maps Xlink channel IDs to PCIe channels.
+
+This component ensures (remote)host-to-(local)host communication, and VPU IP
+communication via an asynchronous passthrough mode, where PCIe data loads are
+directly dispatched to Xlink-IPC.
+
+The component builds and advertises Device IDs that are used by local host
+application in case of multi device scenarios.
+
+XLink-USB
+==========
+This is an endpoint driver that maps Xlink channel IDs to bidirectional
+USB endpoints and supports CDC USB class protocol. More than one Xlink channels
+can be mapped to a single USB endpoint.
+
+This component ensures host-to-host communication, and, as well, asynchronous
+passthrough communication, where USB transfer packets are directly dispatched
+to Xlink-IPC.
+
+The component builds and advertises Device IDs that can are used by local host
+application in case of multi device scenarios.
+
+XLink-ETH
+=========
+
+This is an endpoint driver that maps Xlink channel IDs to Ethernet
+sockets.
+
+This component ensures host-to-host communication, and, as well, asynchronous
+passthrough communication, where Ethernet data loads are directly dispatched to
+Xlink-IPC.
+
+The component builds and advertises Device IDs that can are used by local host
+application in case of multi device scenarios.
+
+Assorted drivers that depend on this stack:
+
+Xlink-SMB
+=========
+The Intel Edge.AI Computer Vision platforms have to be monitored using platform
+devices like sensors, fan controller, IO expander etc. Some of these devices
+are memory mapped and some are I2C-based. None of these devices is directly
+accessible to the host.
+
+The host here refers to the server to which the vision accelerators are
+connected over PCIe Interface. The Host needs to do a consolidated action based
+on the parameters of platform devices. In general, most of the standard devices
+(includes sensors, fan controller, IO expander etc) are I2C/SMBus based and are
+used to provide the status of the accelerator. Standard drivers for these
+devices are available based on I2C/SMBus APIs.
+
+Instead of changing the sensor drivers to adapt to PCIe interface, a generic
+I2C adapter "Xlink-SMBus" which underneath uses Xlink as physical medium is
+used. With Xlink-SMBus, the drivers for the platform devices don't need to
+undergo any interface change.
+
+TSEN
+====
+
+Thermal sensor driver for exporting thermal events to the local Arm64 host as
+well as to the remote X86 host if in the PCIe add-in CV accelerator
+configuration.
+
+The driver receives the junction temperature from different heating points
+inside the SOC. The driver will receive the temperature on SMBus connection and
+forward over Xlink-smb when in a remote host configuration.
+
+In Keem Bay, the four thermal junction temperature points are Media Subsystem
+(mss), Neral Network subsystem (nce), Compute subsystem (cse) and SOC(maximum
+of mss, nce and cse).
+
+HDDL
+====
+
+- Exports details of temperature sensor, current sensor and fan controller
+  present in Intel Edge.AI Computer Vision platforms to IA host.
+- Enable Time sync of Intel Edge.AI Computer Vision platform with IA host.
+- Handles device connect and disconnect events.
+- Receives slave address from the IA host for memory mapped thermal sensors
+  present in SoC (Documentation/hwmon/intel_tsens_sensors.rst).
+- Registers I2C slave device for slaves present in Intel Edge.AI Computer
+  Vision platform
+
+
+VPUMGR (VPU Manager)
+====================
+
+Bridges firmware on VPU side and applications on CPU user-space, it assists
+firmware on VPU side serving multiple user space application processes on CPU
+side concurrently while also performing necessary data buffer management on
+behalf of VPU IP.
-- 
2.17.1


  parent reply	other threads:[~2021-01-30  9:56 UTC|newest]

Thread overview: 82+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-01-30  2:20 [PATCH v3 00/34] Intel Vision Processing base enabling mgross
2021-01-30  2:20 ` [PATCH v3 01/34] Add Vision Processing Unit (VPU) documentation mgross
2021-01-30  2:20 ` [PATCH v3 02/34] dt-bindings: mailbox: Add Intel VPU IPC mailbox bindings mgross
2021-01-30  2:20 ` [PATCH v3 03/34] mailbox: vpu-ipc-mailbox: Add support for Intel VPU IPC mailbox mgross
2021-02-01  7:07   ` Jassi Brar
2021-02-01 15:49     ` Alessandrelli, Daniele
2021-01-30  2:20 ` [PATCH v3 04/34] dt-bindings: Add bindings for Keem Bay IPC driver mgross
2021-01-30  2:20 ` [PATCH v3 05/34] keembay-ipc: Add Keem Bay IPC module mgross
2021-01-30  2:20 ` [PATCH v3 06/34] dt-bindings: Add bindings for Keem Bay VPU IPC driver mgross
2021-01-30  2:20 ` [PATCH v3 07/34] keembay-vpu-ipc: Add Keem Bay VPU IPC module mgross
2021-01-30  2:20 ` [PATCH v3 08/34] misc: xlink-pcie: Add documentation for XLink PCIe driver mgross
2021-01-30  2:20 ` [PATCH v3 09/34] misc: xlink-pcie: lh: Add PCIe EPF driver for Local Host mgross
2021-01-30  2:20 ` [PATCH v3 10/34] misc: xlink-pcie: lh: Add PCIe EP DMA functionality mgross
2021-01-30  2:20 ` [PATCH v3 11/34] misc: xlink-pcie: lh: Add core communication logic mgross
2021-01-30  2:20 ` [PATCH v3 12/34] misc: xlink-pcie: lh: Prepare changes for adding remote host driver mgross
2021-01-30  2:20 ` [PATCH v3 13/34] misc: xlink-pcie: rh: Add PCIe EP driver for Remote Host mgross
2021-01-30  2:20 ` [PATCH v3 14/34] misc: xlink-pcie: rh: Add core communication logic mgross
2021-01-30  2:20 ` [PATCH v3 15/34] misc: xlink-pcie: Add XLink API interface mgross
2021-01-30  2:20 ` [PATCH v3 16/34] misc: xlink-pcie: Add asynchronous event notification support for XLink mgross
2021-01-30  2:20 ` [PATCH v3 17/34] xlink-ipc: Add xlink ipc device tree bindings mgross
2021-01-30  2:20 ` [PATCH v3 18/34] xlink-ipc: Add xlink ipc driver mgross
2021-01-30  2:20 ` [PATCH v3 19/34] xlink-core: Add xlink core device tree bindings mgross
2021-01-30  2:20 ` [PATCH v3 20/34] xlink-core: Add xlink core driver xLink mgross
2021-01-30  2:20 ` [PATCH v3 21/34] xlink-core: Enable xlink protocol over pcie mgross
2021-01-30  2:20 ` [PATCH v3 22/34] xlink-core: Enable VPU IP management and runtime control mgross
2021-01-30  2:20 ` [PATCH v3 23/34] xlink-core: add async channel and events mgross
2021-01-30  2:20 ` [PATCH v3 24/34] dt-bindings: misc: Add Keem Bay vpumgr mgross
2021-01-30  2:20 ` [PATCH v3 25/34] misc: Add Keem Bay VPU manager mgross
2021-02-01  2:04   ` Randy Dunlap
2021-01-30  2:20 ` [PATCH v3 26/34] dt-bindings: misc: intel_tsens: Add tsens thermal bindings documentation mgross
2021-01-30  2:20 ` [PATCH v3 27/34] misc: Tsens ARM host thermal driver mgross
2021-01-30  2:20 ` [PATCH v3 28/34] misc: Intel tsens IA host driver mgross
2021-01-30  7:01   ` Joe Perches
2021-02-02  7:21     ` C, Udhayakumar
2021-01-30  2:20 ` [PATCH v3 29/34] Intel tsens i2c slave driver mgross
2021-02-01  2:07   ` Randy Dunlap
2021-01-30  2:20 ` [PATCH v3 30/34] misc:intel_tsens: Intel Keem Bay tsens driver mgross
2021-01-30  2:20 ` [PATCH v3 31/34] Intel Keem Bay XLink SMBus driver mgross
2021-01-30  2:20 ` [PATCH v3 32/34] dt-bindings: misc: hddl_dev: Add hddl device management documentation mgross
2021-01-30  2:20 ` [PATCH v3 33/34] misc: Hddl device management for local host mgross
2021-01-30  2:20 ` [PATCH v3 34/34] misc: HDDL device management for IA host mgross
2021-01-30  2:20 ` [PATCH v4 00/34] Intel Vision Processing base enabling mgross
2021-01-30  2:20 ` mgross [this message]
2021-01-30  2:20 ` [PATCH v4 02/34] dt-bindings: mailbox: Add Intel VPU IPC mailbox bindings mgross
2021-01-30  2:20 ` [PATCH v4 03/34] mailbox: vpu-ipc-mailbox: Add support for Intel VPU IPC mailbox mgross
2021-01-30  2:20 ` [PATCH v4 04/34] dt-bindings: Add bindings for Keem Bay IPC driver mgross
2021-01-30  2:20 ` [PATCH v4 05/34] keembay-ipc: Add Keem Bay IPC module mgross
2021-01-30  2:20 ` [PATCH v4 06/34] dt-bindings: Add bindings for Keem Bay VPU IPC driver mgross
2021-01-30  2:20 ` [PATCH v4 07/34] keembay-vpu-ipc: Add Keem Bay VPU IPC module mgross
2021-01-30  2:20 ` [PATCH v4 08/34] misc: xlink-pcie: Add documentation for XLink PCIe driver mgross
2021-01-30  2:20 ` [PATCH v4 09/34] misc: xlink-pcie: lh: Add PCIe EPF driver for Local Host mgross
2021-01-30  2:21 ` [PATCH v4 10/34] misc: xlink-pcie: lh: Add PCIe EP DMA functionality mgross
2021-01-30  2:21 ` [PATCH v4 11/34] misc: xlink-pcie: lh: Add core communication logic mgross
2021-01-30  2:21 ` [PATCH v4 12/34] misc: xlink-pcie: lh: Prepare changes for adding remote host driver mgross
2021-01-30  2:21 ` [PATCH v4 13/34] misc: xlink-pcie: rh: Add PCIe EP driver for Remote Host mgross
2021-01-30  2:21 ` [PATCH v4 14/34] misc: xlink-pcie: rh: Add core communication logic mgross
2021-01-30  2:21 ` [PATCH v4 15/34] misc: xlink-pcie: Add XLink API interface mgross
2021-01-30  2:21 ` [PATCH v4 16/34] misc: xlink-pcie: Add asynchronous event notification support for XLink mgross
2021-01-30  2:21 ` [PATCH v4 17/34] xlink-ipc: Add xlink ipc device tree bindings mgross
2021-01-30  2:21 ` [PATCH v4 18/34] xlink-ipc: Add xlink ipc driver mgross
2021-01-30  2:21 ` [PATCH v4 19/34] xlink-core: Add xlink core device tree bindings mgross
2021-01-30  2:21 ` [PATCH v4 20/34] xlink-core: Add xlink core driver xLink mgross
2021-01-30  2:21 ` [PATCH v4 21/34] xlink-core: Enable xlink protocol over pcie mgross
2021-01-30  2:21 ` [PATCH v4 22/34] xlink-core: Enable VPU IP management and runtime control mgross
2021-01-30  2:21 ` [PATCH v4 23/34] xlink-core: add async channel and events mgross
2021-01-30  2:21 ` [PATCH v4 24/34] dt-bindings: misc: Add Keem Bay vpumgr mgross
2021-01-30  2:21 ` [PATCH v4 25/34] misc: Add Keem Bay VPU manager mgross
2021-01-30  2:21 ` [PATCH v4 26/34] dt-bindings: misc: intel_tsens: Add tsens thermal bindings documentation mgross
2021-01-30 17:23   ` Rob Herring
2021-02-02  8:47     ` C, Udhayakumar
2021-01-30  2:21 ` [PATCH v4 27/34] misc: Tsens ARM host thermal driver mgross
2021-01-30  2:21 ` [PATCH v4 28/34] misc: Intel tsens IA host driver mgross
2021-01-30  2:21 ` [PATCH v4 29/34] Intel tsens i2c slave driver mgross
2021-02-01  2:13   ` Randy Dunlap
2021-02-01 15:20     ` Gross, Mark
2021-01-30  2:21 ` [PATCH v4 30/34] misc:intel_tsens: Intel Keem Bay tsens driver mgross
2021-01-30  2:21 ` [PATCH v4 31/34] Intel Keem Bay XLink SMBus driver mgross
2021-01-30  2:21 ` [PATCH v4 32/34] dt-bindings: misc: hddl_dev: Add hddl device management documentation mgross
2021-01-30 17:23   ` Rob Herring
2021-02-02  8:48     ` C, Udhayakumar
2021-01-30  2:21 ` [PATCH v4 33/34] misc: Hddl device management for local host mgross
2021-01-30  2:21 ` [PATCH v4 34/34] misc: HDDL device management for IA host mgross

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20210130022124.65083-37-mgross@linux.intel.com \
    --to=mgross@linux.intel.com \
    --cc=arnd@arndb.de \
    --cc=bp@suse.de \
    --cc=corbet@lwn.net \
    --cc=damien.lemoal@wdc.com \
    --cc=dragan.cvetic@xilinx.com \
    --cc=gregkh@linuxfoundation.org \
    --cc=jassisinghbrar@gmail.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=markgross@kernel.org \
    --cc=palmerdabbelt@google.com \
    --cc=paul.walmsley@sifive.com \
    --cc=peng.fan@nxp.com \
    --cc=robh+dt@kernel.org \
    --cc=shawnguo@kernel.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.