* [PATCH v2] iio: gyro: mpu3050: Fix reported temperature value
@ 2021-04-22 3:38 Dmitry Osipenko
[not found] ` <CAHp75VdkpTqGyHSdYYwYQ-PY2c=pDWeB_-gYKsrA2iX7POPWmQ@mail.gmail.com>
0 siblings, 1 reply; 2+ messages in thread
From: Dmitry Osipenko @ 2021-04-22 3:38 UTC (permalink / raw)
To: Linus Walleij, Jonathan Cameron, Lars-Peter Clausen,
Andy Shevchenko, Maxim Schwalm, Svyatoslav Ryhel
Cc: linux-iio, linux-kernel
The raw temperature value is a 16-bit signed integer. The sign casting
is missing in the code, which results in a wrong temperature reported
by userspace tools, fix it.
Cc: stable@vger.kernel.org
Fixes: 3904b28efb2c ("iio: gyro: Add driver for the MPU-3050 gyroscope")
Datasheet: https://www.cdiweb.com/datasheets/invensense/mpu-3000a.pdf
Tested-by: Maxim Schwalm <maxim.schwalm@gmail.com> # Asus TF700T
Tested-by: Svyatoslav Ryhel <clamor95@gmail.com> # Asus TF201
Reported-by: Svyatoslav Ryhel <clamor95@gmail.com>
Reviewed-by: Andy Shevchenko <Andy.Shevchenko@gmail.com>
Reviewed-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
---
Changelog:
v2: - Replaced "signed 16bit integer" wording with "16-bit signed integer",
replaced "Link" tag with the "Datasheet" and added "Fixes" tag as was
suggested by Andy Shevchenko.
- Added r-b from Andy Shevchenko and Linus Walleij.
drivers/iio/gyro/mpu3050-core.c | 13 +++++++++++--
1 file changed, 11 insertions(+), 2 deletions(-)
diff --git a/drivers/iio/gyro/mpu3050-core.c b/drivers/iio/gyro/mpu3050-core.c
index ac90be03332a..ce9d1d3687f5 100644
--- a/drivers/iio/gyro/mpu3050-core.c
+++ b/drivers/iio/gyro/mpu3050-core.c
@@ -272,7 +272,16 @@ static int mpu3050_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_OFFSET:
switch (chan->type) {
case IIO_TEMP:
- /* The temperature scaling is (x+23000)/280 Celsius */
+ /*
+ * The temperature scaling is (x+23000)/280 Celsius,
+ * where 23000 includes room temperature offset of
+ * +35C, 280 is the precision scale and x is the 16-bit
+ * signed integer which corresponds to the temperature
+ * range of -40C..85C.
+ *
+ * Temperature value itself represents temperature of
+ * the sensor die.
+ */
*val = 23000;
return IIO_VAL_INT;
default:
@@ -329,7 +338,7 @@ static int mpu3050_read_raw(struct iio_dev *indio_dev,
goto out_read_raw_unlock;
}
- *val = be16_to_cpu(raw_val);
+ *val = (s16)be16_to_cpu(raw_val);
ret = IIO_VAL_INT;
goto out_read_raw_unlock;
--
2.30.2
^ permalink raw reply related [flat|nested] 2+ messages in thread
* Re: [PATCH v1] iio: gyro: mpu3050: Fix reported temperature value
[not found] ` <CAHp75VdkpTqGyHSdYYwYQ-PY2c=pDWeB_-gYKsrA2iX7POPWmQ@mail.gmail.com>
@ 2021-04-22 17:42 ` Dmitry Osipenko
0 siblings, 0 replies; 2+ messages in thread
From: Dmitry Osipenko @ 2021-04-22 17:42 UTC (permalink / raw)
To: Andy Shevchenko
Cc: Linus Walleij, Jonathan Cameron, Lars-Peter Clausen,
Maxim Schwalm, Svyatoslav Ryhel, linux-iio, linux-kernel
22.04.2021 09:46, Andy Shevchenko пишет:
> case IIO_TEMP:
> - /* The temperature scaling is (x+23000)/280
> Celsius */
> + /*
> + * The temperature scaling is (x+23000)/280
> Celsius,
> + * where 23000 includes room temperature
> offset of
> + * +35C, 280 is the precision scale and x is
> the 16-bit
> + * signed integer which corresponds to the
> temperature
> + * range of -40C..85C.
>
>
>
> Datasheet says typical -30°... also think about the other comment you
> gave, I.e. about temperature of the die itself. Are you suggesting that
> at -40° the die T is also -40°? Does it have perpetuum mobile ? ;) it
> might dissipate not to much energy, but we don’t know the linearity of
> the curve there.
My understanding that -40C is the minimum temperature which sensor may
report.
Alright, I think the comment could be improved a tad anyways. I'll
prepare v3, thanks.
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2021-04-22 17:43 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2021-04-22 3:38 [PATCH v2] iio: gyro: mpu3050: Fix reported temperature value Dmitry Osipenko
[not found] ` <CAHp75VdkpTqGyHSdYYwYQ-PY2c=pDWeB_-gYKsrA2iX7POPWmQ@mail.gmail.com>
2021-04-22 17:42 ` [PATCH v1] " Dmitry Osipenko
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.