From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: MIME-Version: 1.0 In-Reply-To: References: <20170621061358.GA17661@makarhum-e6330> <20170621094148.GA27878@x1c> From: Luiz Augusto von Dentz Date: Wed, 21 Jun 2017 22:31:39 +0300 Message-ID: Subject: Re: [PATCH] obexd: Fix null pointer dereference. To: Matias Karhumaa , "linux-bluetooth@vger.kernel.org" Content-Type: text/plain; charset="UTF-8" Sender: linux-bluetooth-owner@vger.kernel.org List-ID: Hi Matias, On Wed, Jun 21, 2017 at 8:36 PM, Luiz Augusto von Dentz wrote: > Hi Johan, > > On Wed, Jun 21, 2017 at 12:41 PM, Johan Hedberg wrote: >> Hi Matias, >> >> On Wed, Jun 21, 2017, Matias Karhumaa wrote: >>> By sending OPP Put request before CONNECT we were able to cause >>> SIGSEGV in obexd. Crash was caused by null pointer dereference. >>> >>> gdb output: >>> >>> Program received signal SIGSEGV, Segmentation fault. >>> manager_request_authorization (transfer=transfer@entry=0x0, new_folder=new_folder@entry=0x7fffffffda18, new_name=new_name@entry=0x7fffffffda20) at obexd/src/manager.c:677 >>> 677 struct obex_session *os = transfer->session; >>> (gdb) bt >>> *#0 manager_request_authorization (transfer=transfer@entry=0x0, new_folder=new_folder@entry=0x7fffffffda18, new_name=new_name@entry=0x7fffffffda20) at obexd/src/manager.c:677 >>> *#1 0x000000000041b7a5 in opp_chkput (os=0x67de60, user_data=0x0) at obexd/plugins/opp.c:80 >>> *#2 0x0000000000426cc5 in check_put (obex=0x678a50, req=0x679250, user_data=0x67de60) at obexd/src/obex.c:831 >>> *#3 cmd_put (obex=0x678a50, req=0x679250, user_data=0x67de60) at obexd/src/obex.c:887 >>> *#4 0x00000000004145e7 in handle_request (req=0x679250, obex=0x678a50) at gobex/gobex.c:1199 >>> *#5 incoming_data (io=, cond=, user_data=0x678a50) at gobex/gobex.c:1375 >>> *#6 0x00007ffff749204a in g_main_dispatch (context=0x674810) at /build/glib2.0-prJhLS/glib2.0-2.48.2/./glib/gmain.c:3154 >>> *#7 g_main_context_dispatch (context=context@entry=0x674810) at /build/glib2.0-prJhLS/glib2.0-2.48.2/./glib/gmain.c:3769 >>> *#8 0x00007ffff74923f0 in g_main_context_iterate (context=0x674810, block=block@entry=1, dispatch=dispatch@entry=1, self=) >>> at /build/glib2.0-prJhLS/glib2.0-2.48.2/./glib/gmain.c:3840 >>> *#9 0x00007ffff7492712 in g_main_loop_run (loop=0x66fdf0) at /build/glib2.0-prJhLS/glib2.0-2.48.2/./glib/gmain.c:4034 >>> *#10 0x000000000040dd0f in main (argc=1, argv=0x7fffffffde08) at obexd/src/main.c:322 >>> >>> Crash was found using Synopsys Defensics Obex Server test suite. >>> --- >>> obexd/src/obex.c | 2 +- >>> 1 file changed, 1 insertion(+), 1 deletion(-) >>> >>> diff --git a/obexd/src/obex.c b/obexd/src/obex.c >>> index 788bffc..91fa838 100644 >>> --- a/obexd/src/obex.c >>> +++ b/obexd/src/obex.c >>> @@ -825,7 +825,7 @@ static gboolean check_put(GObex *obex, GObexPacket *req, void *user_data) >>> struct obex_session *os = user_data; >>> int ret; >>> >>> - if (os->service->chkput == NULL) >>> + if (os->service->chkput == NULL || os->service_data == NULL) >>> goto done; >> >> As far as I understand, os->service_data is the OBEX service-specific >> context, which I think can in principle validly be NULL. Also, isn't it >> so that OBEX Object Push permits PUT without a preceding CONNECT (at >> least that's what I remember from the times I was working with OBEX)? > > Yep, OPP can start a transfer without a CONNECT so the service_data > will need to be instantiated directly on PUT if that wasn't created > yet. > >> It seems to me that the bug is with opp.c passing the service_data to >> manager_request_authorization(), and service_data is expected to be the >> obex_transfer object. However, currently the code creates this object >> only upon CONNECT (in opp_connect). >> >> I think one possible way to solve this would be to trigger a call to >> os->service->connect if CONNECT hasn't been explicitly issued, however >> then the code needs to track this in some other way since service_data >> seems too unreliable. How about the following: https://gist.github.com/Vudentz/1736d6af9608b9332b93858d92a3feff -- Luiz Augusto von Dentz