From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1756458AbcJYTeG (ORCPT ); Tue, 25 Oct 2016 15:34:06 -0400 Received: from quechua.inka.de ([193.197.184.2]:48830 "EHLO mail.inka.de" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1750806AbcJYTeD (ORCPT ); Tue, 25 Oct 2016 15:34:03 -0400 X-Greylist: delayed 911 seconds by postgrey-1.27 at vger.kernel.org; Tue, 25 Oct 2016 15:34:03 EDT To: linux-kernel@vger.kernel.org Subject: Re: [RFC] shutdown machine when li-ion battery goes below 3V References: <20161024212250.GA31336@amd> Organization: MIME-Version: 1.0 Content-Type: text/plain; charset=US-ASCII Content-Transfer-Encoding: 7BIT From: Olaf Titz Date: Tue, 25 Oct 2016 21:18:46 +0200 Message-ID: Sender: linux-kernel-owner@vger.kernel.org List-ID: X-Mailing-List: linux-kernel@vger.kernel.org > + res = bq27xxx_battery_voltage(di, &val); > + if (res) > + return res; > + > + mV = val.intval / 1000; Reading that code I stumbled over the comment in bq27xxx_battery_voltage saying that it returns millivolts. The code here, the code in bq27xxx_battery_voltage and power_supply.h all indicate that it in fact returns microvolts. Please double-check and fix, as it stands now the code looks inconsistent (but not knowing that device at all I don't feel fit to submit a fix). regards, Olaf