On Fri, May 20, 2022 at 03:33:03PM +0200, AngeloGioacchino Del Regno wrote: > +// SPDX-License-Identifier: GPL-2.0 > +/* > + * Copyright (c) 2022 Collabora Ltd. > + * Author: AngeloGioacchino Del Regno > + * Please make the entire comment a C++ one so things look more intentional. > +static const unsigned int ldo_volt_table10[] = { > + 1200000, 1300000, 1500000, 1800000, > + 1200000, 1300000, 1500000, 1800000, > + 1200000, 1300000, 1500000, 1800000, > + 1200000, 1300000, 1500000, 1800000, > +}; So the top bits of the voltate selection field just get ignored? Might be easier to just write the code to not include the top bits. > +static int mt6331_get_status(struct regulator_dev *rdev) > +{ > + struct mt6331_regulator_info *info = rdev_get_drvdata(rdev); > + u32 reg, en_mask, regval; > + int ret; > + > + if (info->qi > 0) { > + reg = info->desc.enable_reg; > + en_mask = info->qi; If the regulator doesn't have status readback it shouldn't provide a get_status() operation. > +static int mt6331_ldo_set_mode(struct regulator_dev *rdev, unsigned int mode) > +{ > + int ret, val = 0; > + struct mt6331_regulator_info *info = rdev_get_drvdata(rdev); > + > + if (!info->modeset_mask) { > + dev_err(&rdev->dev, "regulator %s doesn't support set_mode\n", > + info->desc.name); > + return -EINVAL; > + } Just don't provide the operation for these regulators then. That'll mean a separate ops struct but that's fine.