From: Niklas Söderlund commit 0f510a2457cbbba18a98492bab1bf540be57ebd1 upstream. The hardware manual states that the operation of the sensor is not guaranteed with temperatures above 125°C, not that the readings are invalid. Remove the bound check and try to deliver temperature readings even if we are outside the guaranteed operation range. Signed-off-by: Niklas Söderlund Signed-off-by: Daniel Lezcano Link: https://lore.kernel.org/r/20200117160554.3812787-3-niklas.soderlund+renesas@ragnatech.se Signed-off-by: Biju Das --- drivers/thermal/rcar_gen3_thermal.c | 4 +--- 1 file changed, 1 insertion(+), 3 deletions(-) diff --git a/drivers/thermal/rcar_gen3_thermal.c b/drivers/thermal/rcar_gen3_thermal.c index 42ec69d29540..e7a0c7fc9897 100644 --- a/drivers/thermal/rcar_gen3_thermal.c +++ b/drivers/thermal/rcar_gen3_thermal.c @@ -182,9 +182,7 @@ static int rcar_gen3_thermal_get_temp(void *devdata, int *temp) tsc->coef.a2); mcelsius = FIXPT_TO_MCELSIUS(val); - /* Make sure we are inside specifications */ - if ((mcelsius < MCELSIUS(-40)) || (mcelsius > MCELSIUS(125))) - return -EIO; + /* Guaranteed operating range is -40C to 125C. */ /* Round value to device granularity setting */ *temp = rcar_gen3_thermal_round(mcelsius); -- 2.17.1