From mboxrd@z Thu Jan 1 00:00:00 1970 From: dianders@chromium.org (Doug Anderson) Date: Wed, 6 Aug 2014 19:16:51 -0700 Subject: [PATCH v4 2/2] pwm: rockchip: Added to support for RK3288 SoC In-Reply-To: <53E2D605.2000704@rock-chips.com> References: <1406197295-10604-1-git-send-email-caesar.wang@rock-chips.com> <1406197295-10604-3-git-send-email-caesar.wang@rock-chips.com> <53E2D605.2000704@rock-chips.com> Message-ID: To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org Caesar, On Wed, Aug 6, 2014 at 6:27 PM, caesar wrote: > Doug, > > ? 2014?08?07? 06:46, Doug Anderson ??: > >> Caesar, >> >> On Thu, Jul 24, 2014 at 3:21 AM, Caesar Wang >> wrote: >>> >>> +static const struct rockchip_pwm_data pwm_data_v1 = { >>> + .regs.duty = PWM_HRC, >>> + .regs.period = PWM_LRC, >>> + .regs.cntr = PWM_CNTR, >>> + .regs.ctrl = PWM_CTRL, >>> + .prescaler = PRESCALER, >>> + .set_enable = rockchip_pwm_set_enable_v1, >>> +}; >>> + >>> +static const struct rockchip_pwm_data pwm_data_v2 = { >>> + .regs.duty = PWM_LRC, >>> + .regs.period = PWM_HRC, >>> + .regs.cntr = PWM_CNTR, >>> + .regs.ctrl = PWM_CTRL, >>> + .prescaler = PRESCALER-1, >>> + .set_enable = rockchip_pwm_set_enable_v2, >>> +}; >>> + >>> +static const struct rockchip_pwm_data pwm_data_vop = { >>> + .regs.duty = PWM_LRC, >>> + .regs.period = PWM_HRC, >>> + .regs.cntr = PWM_CTRL, >>> + .regs.ctrl = PWM_CNTR, >> >> Did you really mean to flip CTRL and CNTR here? If so, that's super >> confusing and deserves a comment. AKA, I think the above should not >> be: >> >> + .regs.cntr = PWM_CTRL, >> + .regs.ctrl = PWM_CNTR, >> >> ...but should be >> >> + .regs.cntr = PWM_CNTR, >> + .regs.ctrl = PWM_CTRL, >> >> If you didn't mean to flip CTRL and CNTR here, then just get rid of >> pwm_data_vop and refer to pwm_data_v2. In fact, I'd suggest that you >> totally remove the "rockchip,vop-pwm" since there's nothing different >> between "rockchip,rk3288-pwm" and "rockchip,vop-pwm". > > > Sorry,I think it's no problem. the "rockchip,rk3288-pwm" and > "rockchip,vop-pwm" are seperate PWM controllers. > They are just different registers address between CNTR and CTRL . OK, I looked up in the TRM. Right, the CNTR and CTRL are flipped on the vop. So I think that the only change you need is to add: #define PWM_VOP_CTRL 0x00 #define PWM_VOP_CNTR 0x0c ...then use these new #defines for the vop structure. As you have the code written right now it's very confusing. The new #defines will fix this. >> Have you validated Thierry's suggestion to allow you to access your >> memory range? > > Yes,we have solve it in lcdc driver. > The Mark Yao have the submission in [0]. > > [0]: https://lkml.org/lkml/2014/8/4/20 Excellent! Then we should be able to land after you fix the above. -Doug