From mboxrd@z Thu Jan 1 00:00:00 1970 From: Amit Kucheria Subject: [PATCHv3 18/23] drivers: thermal: tsens: Common get_temp() learns to do ADC conversion Date: Wed, 20 Mar 2019 18:47:58 +0530 Message-ID: <389f9e70f715e2884418d77c9ff06fad6878eacc.1553086065.git.amit.kucheria@linaro.org> References: Return-path: In-Reply-To: In-Reply-To: References: Sender: linux-kernel-owner@vger.kernel.org To: linux-kernel@vger.kernel.org, linux-arm-msm@vger.kernel.org, bjorn.andersson@linaro.org, edubezval@gmail.com, andy.gross@linaro.org, Daniel Lezcano , David Brown , Zhang Rui Cc: linux-pm@vger.kernel.org List-Id: linux-arm-msm@vger.kernel.org get_temp() learns to return temperature regardless of whether it is returned as ADC code or direct temperature. Signed-off-by: Amit Kucheria --- drivers/thermal/qcom/tsens-common.c | 13 +++++++++---- 1 file changed, 9 insertions(+), 4 deletions(-) diff --git a/drivers/thermal/qcom/tsens-common.c b/drivers/thermal/qcom/tsens-common.c index 5adbf1a2e0fb..92747ccb2850 100644 --- a/drivers/thermal/qcom/tsens-common.c +++ b/drivers/thermal/qcom/tsens-common.c @@ -129,10 +129,15 @@ int get_temp_tsens_valid(struct tsens_priv *priv, int i, int *temp) if (ret) return ret; - mask = GENMASK(priv->fields[LAST_TEMP_0].msb, - priv->fields[LAST_TEMP_0].lsb); - /* Convert temperature from deciCelsius to milliCelsius */ - *temp = sign_extend32(last_temp, fls(mask) - 1) * 100; + if (priv->feat->adc) { + /* Convert temperature from ADC code to milliCelsius */ + *temp = code_to_degc(last_temp, s) * 1000; + } else { + mask = GENMASK(priv->fields[LAST_TEMP_0].msb, + priv->fields[LAST_TEMP_0].lsb); + /* Convert temperature from deciCelsius to milliCelsius */ + *temp = sign_extend32(last_temp, fls(mask) - 1) * 100; + } return 0; } -- 2.17.1