devicetree.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
* [PATCH v13 2/3] dt-bindings: iio: temperature: add MLX90632 device bindings
@ 2018-01-11 10:20 Crt Mori
       [not found] ` <20180111102010.27350-1-cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>
  0 siblings, 1 reply; 2+ messages in thread
From: Crt Mori @ 2018-01-11 10:20 UTC (permalink / raw)
  To: Jonathan Cameron
  Cc: linux-iio-u79uwXL29TY76Z2rM5mHXA,
	devicetree-u79uwXL29TY76Z2rM5mHXA, Crt Mori

Add device tree bindings for MLX90632 IR temperature sensor.

Signed-off-by: Crt Mori <cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>
Reviewed-by: Rob Herring <robh-DgEjT+Ai2ygdnm+yROfE0A@public.gmane.org>
---
 .../bindings/iio/temperature/mlx90632.txt          | 28 ++++++++++++++++++++++
 1 file changed, 28 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/iio/temperature/mlx90632.txt

diff --git a/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
new file mode 100644
index 000000000000..0b05812001f8
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
@@ -0,0 +1,28 @@
+* Melexis MLX90632 contactless Infra Red temperature sensor
+
+Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
+
+There are various applications for the Infra Red contactless temperature sensor
+and MLX90632 is most suitable for consumer applications where measured object
+temperature is in range between -20 to 200 degrees Celsius with relative error
+of measurement below 1 degree Celsius in object temperature range for
+industrial applications. Since it can operate and measure ambient temperature
+in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
+
+Be aware that electronics surrounding the sensor can increase ambient
+temperature. MLX90632 can be calibrated to reduce the housing effect via
+already existing EEPROM parameters.
+
+Since measured object emissivity effects Infra Red energy emitted, emissivity
+should be set before requesting the object temperature.
+
+Required properties:
+  - compatible: should be "melexis,mlx90632"
+  - reg: the I2C address of the sensor (default 0x3a)
+
+Example:
+
+mlx90632@3a {
+	compatible = "melexis,mlx90632";
+	reg = <0x3a>;
+};
-- 
2.15.0

^ permalink raw reply related	[flat|nested] 2+ messages in thread

* Re: [PATCH v13 2/3] dt-bindings: iio: temperature: add MLX90632 device bindings
       [not found] ` <20180111102010.27350-1-cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>
@ 2018-02-04 10:21   ` Jonathan Cameron
  0 siblings, 0 replies; 2+ messages in thread
From: Jonathan Cameron @ 2018-02-04 10:21 UTC (permalink / raw)
  To: Crt Mori
  Cc: linux-iio-u79uwXL29TY76Z2rM5mHXA, devicetree-u79uwXL29TY76Z2rM5mHXA

On Thu, 11 Jan 2018 11:20:10 +0100
Crt Mori <cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org> wrote:

> Add device tree bindings for MLX90632 IR temperature sensor.
> 
> Signed-off-by: Crt Mori <cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>
> Reviewed-by: Rob Herring <robh-DgEjT+Ai2ygdnm+yROfE0A@public.gmane.org>
Applied to the togreg branch of iio.git and pushed out as testing
for the autobuilders to play with it.

Jonathan

> ---
>  .../bindings/iio/temperature/mlx90632.txt          | 28 ++++++++++++++++++++++
>  1 file changed, 28 insertions(+)
>  create mode 100644 Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
> 
> diff --git a/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
> new file mode 100644
> index 000000000000..0b05812001f8
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
> @@ -0,0 +1,28 @@
> +* Melexis MLX90632 contactless Infra Red temperature sensor
> +
> +Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
> +
> +There are various applications for the Infra Red contactless temperature sensor
> +and MLX90632 is most suitable for consumer applications where measured object
> +temperature is in range between -20 to 200 degrees Celsius with relative error
> +of measurement below 1 degree Celsius in object temperature range for
> +industrial applications. Since it can operate and measure ambient temperature
> +in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
> +
> +Be aware that electronics surrounding the sensor can increase ambient
> +temperature. MLX90632 can be calibrated to reduce the housing effect via
> +already existing EEPROM parameters.
> +
> +Since measured object emissivity effects Infra Red energy emitted, emissivity
> +should be set before requesting the object temperature.
> +
> +Required properties:
> +  - compatible: should be "melexis,mlx90632"
> +  - reg: the I2C address of the sensor (default 0x3a)
> +
> +Example:
> +
> +mlx90632@3a {
> +	compatible = "melexis,mlx90632";
> +	reg = <0x3a>;
> +};

^ permalink raw reply	[flat|nested] 2+ messages in thread

end of thread, other threads:[~2018-02-04 10:21 UTC | newest]

Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2018-01-11 10:20 [PATCH v13 2/3] dt-bindings: iio: temperature: add MLX90632 device bindings Crt Mori
     [not found] ` <20180111102010.27350-1-cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>
2018-02-04 10:21   ` Jonathan Cameron

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).