On Fri, Oct 23, 2020 at 10:56 PM Ray Jui wrote: > > > > On 10/13/2020 10:12 PM, Rayagonda Kokatanur wrote: > > > > > > On Wed, Oct 14, 2020 at 8:50 AM Dhananjay Phadke > > > wrote: > > > > On Sun, 11 Oct 2020 23:52:53 +0530, Rayagonda Kokatanur wrote: > > > --- a/drivers/i2c/busses/i2c-bcm-iproc.c > > > +++ b/drivers/i2c/busses/i2c-bcm-iproc.c > > > > > > - } else if (status & BIT(IS_S_RD_EVENT_SHIFT)) { > > > - /* Start of SMBUS for Master Read */ > > > + I2C_SLAVE_WRITE_REQUESTED, > > &rx_data); > > > + iproc_i2c->rx_start_rcvd = true; > > > + iproc_i2c->slave_read_complete = false; > > > + } else if (rx_status == I2C_SLAVE_RX_DATA && > > > + iproc_i2c->rx_start_rcvd) { > > > + /* Middle of SMBUS Master write */ > > > i2c_slave_event(iproc_i2c->slave, > > > - I2C_SLAVE_READ_REQUESTED, > > &value); > > > - iproc_i2c_wr_reg(iproc_i2c, S_TX_OFFSET, value); > > > + I2C_SLAVE_WRITE_RECEIVED, > > &rx_data); > > > + } else if (rx_status == I2C_SLAVE_RX_END && > > > + iproc_i2c->rx_start_rcvd) { > > > + /* End of SMBUS Master write */ > > > + if (iproc_i2c->slave_rx_only) > > > + i2c_slave_event(iproc_i2c->slave, > > > + > > I2C_SLAVE_WRITE_RECEIVED, > > > + &rx_data); > > > + > > > + i2c_slave_event(iproc_i2c->slave, > > I2C_SLAVE_STOP, > > > + &rx_data); > > > + } else if (rx_status == I2C_SLAVE_RX_FIFO_EMPTY) { > > > + iproc_i2c->rx_start_rcvd = false; > > > + iproc_i2c->slave_read_complete = true; > > > + break; > > > + } > > > > > > - val = BIT(S_CMD_START_BUSY_SHIFT); > > > - iproc_i2c_wr_reg(iproc_i2c, S_CMD_OFFSET, val); > > > + rx_bytes++; > > > > rx_bytes should be incremented only along with > > I2C_SLAVE_WRITE_RECEIVED event? > > > > > > It should be incremented in both I2C_SLAVE_WRITE_REQUESTED and > > I2C_SLAVE_WRITE_RECEIVED cases because in both case it is reading valid > > bytes from rx fifo. > > > > > > > > > > +static bool bcm_iproc_i2c_slave_isr(struct bcm_iproc_i2c_dev > > *iproc_i2c, > > > + u32 status) > > > +{ > > > + u32 val; > > > + u8 value; > > > + > > > + /* > > > + * Slave events in case of master-write, master-write-read and, > > > + * master-read > > > + * > > > + * Master-write : only IS_S_RX_EVENT_SHIFT event > > > + * Master-write-read: both IS_S_RX_EVENT_SHIFT and > > IS_S_RD_EVENT_SHIFT > > > + * events > > > + * Master-read : both IS_S_RX_EVENT_SHIFT and > > IS_S_RD_EVENT_SHIFT > > > + * events or only IS_S_RD_EVENT_SHIFT > > > + */ > > > + if (status & BIT(IS_S_RX_EVENT_SHIFT) || > > > + status & BIT(IS_S_RD_EVENT_SHIFT)) { > > > + /* disable slave interrupts */ > > > + val = iproc_i2c_rd_reg(iproc_i2c, IE_OFFSET); > > > + val &= ~iproc_i2c->slave_int_mask; > > > + iproc_i2c_wr_reg(iproc_i2c, IE_OFFSET, val); > > > + > > > + if (status & BIT(IS_S_RD_EVENT_SHIFT)) > > > + /* Master-write-read request */ > > > + iproc_i2c->slave_rx_only = false; > > > + else > > > + /* Master-write request only */ > > > + iproc_i2c->slave_rx_only = true; > > > + > > > + /* schedule tasklet to read data later */ > > > + tasklet_schedule(&iproc_i2c->slave_rx_tasklet); > > > + > > > + /* clear only IS_S_RX_EVENT_SHIFT interrupt */ > > > + iproc_i2c_wr_reg(iproc_i2c, IS_OFFSET, > > > + BIT(IS_S_RX_EVENT_SHIFT)); > > > > > > > Both tasklet and isr are writing to status (IS_OFFSET) reg. > > > > > > Yes this is required. > > > > For ex, If IS_S_RD_EVENT_SHIFT interrupt, this should be cleared once > > the driver completes reading all data from rx fifo. > > After this the driver can start sending data to master. > > > > If both tasklet and isr are accessing the IS_OFFSET register, don't you > need lock protection against race condition? That is, ISR can interrupt > tasklet. All interrupts are disbaled when the tasklet is running. Interrupts are re-enabled at the end of the tasklet. So no race condition between tasklet and isr. Best regards, Rayagonda > > > > > > > The tasklet seems to be batching up rx fifo reads because of > > time-sensitive > > Master-write-read transaction? Linux I2C framework is byte interface > > anyway. > > Can the need to batch reads be avoided by setting slave rx threshold for > > interrupt (S_FIFO_RX_THLD) to 1-byte? > > > > > > To process more data with a single interrupt we are batching up rx fifo > > reads. > > This will reduce the number of interrupts. > > > > Also to avoid tasklet running more time (20us) we have a threshold of 10 > > bytes for batching read. > > This is a better/optimised approach than reading single byte data per > > interrupt. > > > > > > Also, wouldn't tasklets be susceptible to other interrupts? If fifo > > reads > > have to be batched up, can it be changed to threaded irq? > > > > > > tasklets have higher priority than threaded irq, since i2c is time > > sensitive so using a tasklet is preferred over threaded irq. > >