From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: X-Spam-Checker-Version: SpamAssassin 3.4.0 (2014-02-07) on aws-us-west-2-korg-lkml-1.web.codeaurora.org X-Spam-Level: X-Spam-Status: No, score=-16.8 required=3.0 tests=BAYES_00, HEADER_FROM_DIFFERENT_DOMAINS,INCLUDES_CR_TRAILER,INCLUDES_PATCH, MAILING_LIST_MULTI,SPF_HELO_NONE,SPF_PASS,USER_AGENT_GIT autolearn=unavailable autolearn_force=no version=3.4.0 Received: from mail.kernel.org (mail.kernel.org [198.145.29.99]) by smtp.lore.kernel.org (Postfix) with ESMTP id 28D79C433E0 for ; Wed, 3 Mar 2021 02:49:28 +0000 (UTC) Received: from vger.kernel.org (vger.kernel.org [23.128.96.18]) by mail.kernel.org (Postfix) with ESMTP id D15FD64EA4 for ; Wed, 3 Mar 2021 02:49:27 +0000 (UTC) Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S232444AbhCCCj4 (ORCPT ); Tue, 2 Mar 2021 21:39:56 -0500 Received: from lizzard.sbs.de ([194.138.37.39]:46166 "EHLO lizzard.sbs.de" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1579464AbhCBQ6e (ORCPT ); Tue, 2 Mar 2021 11:58:34 -0500 Received: from mail1.sbs.de (mail1.sbs.de [192.129.41.35]) by lizzard.sbs.de (8.15.2/8.15.2) with ESMTPS id 122GXDXW028682 (version=TLSv1.2 cipher=DHE-RSA-AES256-GCM-SHA384 bits=256 verify=OK); Tue, 2 Mar 2021 17:33:13 +0100 Received: from md1za8fc.ad001.siemens.net ([167.87.44.113]) by mail1.sbs.de (8.15.2/8.15.2) with ESMTP id 122GXBHO025192; Tue, 2 Mar 2021 17:33:12 +0100 From: Henning Schild To: linux-kernel@vger.kernel.org, linux-leds@vger.kernel.org, platform-driver-x86@vger.kernel.org, linux-watchdog@vger.kernel.org Cc: Srikanth Krishnakar , Jan Kiszka , Henning Schild , Gerd Haeussler , Guenter Roeck , Wim Van Sebroeck , Mark Gross , Hans de Goede , Pavel Machek Subject: [PATCH 1/4] platform/x86: simatic-ipc: add main driver for Siemens devices Date: Tue, 2 Mar 2021 17:33:06 +0100 Message-Id: <20210302163309.25528-2-henning.schild@siemens.com> X-Mailer: git-send-email 2.26.2 In-Reply-To: <20210302163309.25528-1-henning.schild@siemens.com> References: <20210302163309.25528-1-henning.schild@siemens.com> MIME-Version: 1.0 Content-Transfer-Encoding: 8bit Precedence: bulk List-ID: X-Mailing-List: linux-leds@vger.kernel.org From: Henning Schild This mainly implements detection of these devices and will allow secondary drivers to work on such machines. The identification is DMI-based with a vendor specific way to tell them apart in a reliable way. Drivers for LEDs and Watchdogs will follow to make use of that platform detection. Signed-off-by: Gerd Haeussler Signed-off-by: Henning Schild --- drivers/platform/x86/Kconfig | 9 + drivers/platform/x86/Makefile | 3 + drivers/platform/x86/simatic-ipc.c | 166 ++++++++++++++++++ .../platform_data/x86/simatic-ipc-base.h | 33 ++++ include/linux/platform_data/x86/simatic-ipc.h | 68 +++++++ 5 files changed, 279 insertions(+) create mode 100644 drivers/platform/x86/simatic-ipc.c create mode 100644 include/linux/platform_data/x86/simatic-ipc-base.h create mode 100644 include/linux/platform_data/x86/simatic-ipc.h diff --git a/drivers/platform/x86/Kconfig b/drivers/platform/x86/Kconfig index ad4e630e73e2..bb9e282d89cf 100644 --- a/drivers/platform/x86/Kconfig +++ b/drivers/platform/x86/Kconfig @@ -1284,6 +1284,15 @@ config INTEL_TELEMETRY directly via debugfs files. Various tools may use this interface for SoC state monitoring. +config SIEMENS_SIMATIC_IPC + tristate "Siemens Simatic IPC Class driver" + depends on PCI + help + This Simatic IPC class driver is the central of several drivers. It + is mainly used for system identification, after which drivers in other + classes will take care of driving specifics of those machines. + i.e. leds and watchdogs + endif # X86_PLATFORM_DEVICES config PMC_ATOM diff --git a/drivers/platform/x86/Makefile b/drivers/platform/x86/Makefile index 60d554073749..26cdebf2e701 100644 --- a/drivers/platform/x86/Makefile +++ b/drivers/platform/x86/Makefile @@ -138,3 +138,6 @@ obj-$(CONFIG_INTEL_TELEMETRY) += intel_telemetry_core.o \ intel_telemetry_pltdrv.o \ intel_telemetry_debugfs.o obj-$(CONFIG_PMC_ATOM) += pmc_atom.o + +# Siemens Simatic Industrial PCs +obj-$(CONFIG_SIEMENS_SIMATIC_IPC) += simatic-ipc.o diff --git a/drivers/platform/x86/simatic-ipc.c b/drivers/platform/x86/simatic-ipc.c new file mode 100644 index 000000000000..6adcdac1a0d7 --- /dev/null +++ b/drivers/platform/x86/simatic-ipc.c @@ -0,0 +1,166 @@ +// SPDX-License-Identifier: GPL-2.0 +/* + * Siemens SIMATIC IPC driver for LEDs + * + * Copyright (c) Siemens AG, 2018-2021 + * + * Authors: + * Henning Schild + * Jan Kiszka + * Gerd Haeussler + * + * This program is free software; you can redistribute it and/or modify + * it under the terms of the GNU General Public License version 2 as + * published by the Free Software Foundation. + */ + +#include +#include +#include +#include + +static struct platform_device *ipc_led_platform_device; +static struct platform_device *ipc_wdt_platform_device; + +static const struct dmi_system_id simatic_ipc_whitelist[] = { + { + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"), + }, + }, + {} +}; + +static struct simatic_ipc_platform platform_data; + +static struct { + u32 station_id; + u8 led_mode; + u8 wdt_mode; +} device_modes[] = { + { SIMATIC_IPC_IPC127E, SIMATIC_IPC_DEVICE_127E, SIMATIC_IPC_DEVICE_NONE}, + { SIMATIC_IPC_IPC227D, SIMATIC_IPC_DEVICE_227D, SIMATIC_IPC_DEVICE_NONE}, + { SIMATIC_IPC_IPC227E, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_227E}, + { SIMATIC_IPC_IPC277E, SIMATIC_IPC_DEVICE_NONE, SIMATIC_IPC_DEVICE_227E}, + { SIMATIC_IPC_IPC427D, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_NONE}, + { SIMATIC_IPC_IPC427E, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_427E}, + { SIMATIC_IPC_IPC477E, SIMATIC_IPC_DEVICE_NONE, SIMATIC_IPC_DEVICE_427E}, +}; + +static int register_platform_devices(u32 station_id) +{ + int i; + u8 ledmode = SIMATIC_IPC_DEVICE_NONE; + u8 wdtmode = SIMATIC_IPC_DEVICE_NONE; + + platform_data.devmode = SIMATIC_IPC_DEVICE_NONE; + + for (i = 0; i < ARRAY_SIZE(device_modes); i++) { + if (device_modes[i].station_id == station_id) { + ledmode = device_modes[i].led_mode; + wdtmode = device_modes[i].wdt_mode; + break; + } + } + + if (ledmode != SIMATIC_IPC_DEVICE_NONE) { + platform_data.devmode = ledmode; + ipc_led_platform_device = platform_device_register_data + (NULL, KBUILD_MODNAME "_leds", PLATFORM_DEVID_NONE, + &platform_data, sizeof(struct simatic_ipc_platform)); + if (IS_ERR(ipc_led_platform_device)) + return PTR_ERR(ipc_led_platform_device); + + pr_debug(KBUILD_MODNAME ": device=%s created\n", + ipc_led_platform_device->name); + } + + if (wdtmode != SIMATIC_IPC_DEVICE_NONE) { + platform_data.devmode = wdtmode; + ipc_wdt_platform_device = platform_device_register_data + (NULL, KBUILD_MODNAME "_wdt", PLATFORM_DEVID_NONE, + &platform_data, sizeof(struct simatic_ipc_platform)); + if (IS_ERR(ipc_wdt_platform_device)) + return PTR_ERR(ipc_wdt_platform_device); + + pr_debug(KBUILD_MODNAME ": device=%s created\n", + ipc_wdt_platform_device->name); + } + + if (ledmode == SIMATIC_IPC_DEVICE_NONE && + wdtmode == SIMATIC_IPC_DEVICE_NONE) { + pr_warn(KBUILD_MODNAME + ": unsupported IPC detected, station id=%08x\n", + station_id); + return -EINVAL; + } else { + return 0; + } +} + +/* + * Get membase address from PCI, used in leds and wdt modul. Here we read + * the bar0. The final address calculation is done in the appropriate modules + */ + +u32 simatic_ipc_get_membase0(unsigned int p2sb) +{ + u32 bar0 = 0; +#ifdef CONFIG_PCI + struct pci_bus *bus; + /* + * The GPIO memory is bar0 of the hidden P2SB device. Unhide the device + * to have a quick look at it, before we hide it again. + * Also grab the pci rescan lock so that device does not get discovered + * and remapped while it is visible. + * This code is inspired by drivers/mfd/lpc_ich.c + */ + bus = pci_find_bus(0, 0); + pci_lock_rescan_remove(); + pci_bus_write_config_byte(bus, p2sb, 0xE1, 0x0); + pci_bus_read_config_dword(bus, p2sb, PCI_BASE_ADDRESS_0, &bar0); + + bar0 &= ~0xf; + pci_bus_write_config_byte(bus, p2sb, 0xE1, 0x1); + pci_unlock_rescan_remove(); +#endif /* CONFIG_PCI */ + return bar0; +} +EXPORT_SYMBOL(simatic_ipc_get_membase0); + +static int __init simatic_ipc_init_module(void) +{ + const struct dmi_system_id *match; + u32 station_id; + int err; + + match = dmi_first_match(simatic_ipc_whitelist); + if (!match) + return 0; + + err = dmi_walk(simatic_ipc_find_dmi_entry_helper, &station_id); + + if (err || station_id == SIMATIC_IPC_INVALID_STATION_ID) { + pr_warn(KBUILD_MODNAME ": DMI entry %d not found\n", + DMI_ENTRY_OEM); + return 0; + } + + return register_platform_devices(station_id); +} + +static void __exit simatic_ipc_exit_module(void) +{ + platform_device_unregister(ipc_led_platform_device); + ipc_led_platform_device = NULL; + + platform_device_unregister(ipc_wdt_platform_device); + ipc_wdt_platform_device = NULL; +} + +module_init(simatic_ipc_init_module); +module_exit(simatic_ipc_exit_module); + +MODULE_LICENSE("GPL"); +MODULE_AUTHOR("Gerd Haeussler "); +MODULE_ALIAS("dmi:*:svnSIEMENSAG:*"); diff --git a/include/linux/platform_data/x86/simatic-ipc-base.h b/include/linux/platform_data/x86/simatic-ipc-base.h new file mode 100644 index 000000000000..d8e59eb8fc96 --- /dev/null +++ b/include/linux/platform_data/x86/simatic-ipc-base.h @@ -0,0 +1,33 @@ +/* SPDX-License-Identifier: GPL-2.0 */ +/* + * Siemens SIMATIC IPC drivers + * + * Copyright (c) Siemens AG, 2018-2021 + * + * Authors: + * Henning Schild + * Gerd Haeussler + * + * This program is free software; you can redistribute it and/or modify + * it under the terms of the GNU General Public License version 2 as + * published by the Free Software Foundation. + */ + +#ifndef __PLATFORM_DATA_X86_SIMATIC_IPC_BASE_H +#define __PLATFORM_DATA_X86_SIMATIC_IPC_BASE_H + +#include + +#define SIMATIC_IPC_DEVICE_NONE 0 +#define SIMATIC_IPC_DEVICE_227D 1 +#define SIMATIC_IPC_DEVICE_427E 2 +#define SIMATIC_IPC_DEVICE_127E 3 +#define SIMATIC_IPC_DEVICE_227E 4 + +struct simatic_ipc_platform { + u8 devmode; +}; + +u32 simatic_ipc_get_membase0(unsigned int p2sb); + +#endif /* __PLATFORM_DATA_X86_SIMATIC_IPC_BASE_H */ diff --git a/include/linux/platform_data/x86/simatic-ipc.h b/include/linux/platform_data/x86/simatic-ipc.h new file mode 100644 index 000000000000..90bb0d7cf09a --- /dev/null +++ b/include/linux/platform_data/x86/simatic-ipc.h @@ -0,0 +1,68 @@ +/* SPDX-License-Identifier: GPL-2.0 */ +/* + * Siemens SIMATIC IPC drivers + * + * Copyright (c) Siemens AG, 2018-2021 + * + * Authors: + * Henning Schild + * Gerd Haeussler + * + * This program is free software; you can redistribute it and/or modify + * it under the terms of the GNU General Public License version 2 as + * published by the Free Software Foundation. + */ + +#ifndef __PLATFORM_DATA_X86_SIMATIC_IPC_H +#define __PLATFORM_DATA_X86_SIMATIC_IPC_H + +#include +#include + +#define DMI_ENTRY_OEM 129 + +enum simatic_ipc_station_ids { + SIMATIC_IPC_INVALID_STATION_ID = 0, + SIMATIC_IPC_IPC227D = 0x00000501, + SIMATIC_IPC_IPC427D = 0x00000701, + SIMATIC_IPC_IPC227E = 0x00000901, + SIMATIC_IPC_IPC277E = 0x00000902, + SIMATIC_IPC_IPC427E = 0x00000A01, + SIMATIC_IPC_IPC477E = 0x00000A02, + SIMATIC_IPC_IPC127E = 0x00000D01, +}; + +static inline u32 simatic_ipc_get_station_id(u8 *data) +{ + u32 station_id = SIMATIC_IPC_INVALID_STATION_ID; + int i; + struct { + u8 type; /* type (0xff = binary) */ + u8 len; /* len of data entry */ + u8 reserved[3]; + u32 station_id; /* station id (LE) */ + } __packed * data_entry = (void *)data; + + /* find 4th entry in OEM data */ + for (i = 0; i < 3; i++) + data_entry = (void *)((u8 *)(data_entry) + data_entry->len); + + /* decode station id */ + if (data_entry && data_entry->type == 0xff && data_entry->len == 9) + station_id = le32_to_cpu(data_entry->station_id); + + return station_id; +} + +static inline void +simatic_ipc_find_dmi_entry_helper(const struct dmi_header *dh, void *_data) +{ + u32 *id = _data; + + if (dh->type != DMI_ENTRY_OEM) + return; + + *id = simatic_ipc_get_station_id((u8 *)dh + sizeof(struct dmi_header)); +} + +#endif /* __PLATFORM_DATA_X86_SIMATIC_IPC_H */ -- 2.26.2