Hi, On Fri, Nov 16, 2018 at 05:23:47PM +0100, Lubomir Rintel wrote: > According to [1] and [2], the temperature values are in tenths of degree > Celsius. Exposing the Celsius value makes the battery appear on fire: > > $ upower -i /org/freedesktop/UPower/devices/battery_olpc_battery > ... > temperature: 236.9 degrees C > > Tested on OLPC XO-1 and OLPC XO-1.75 laptops. > > [1] include/linux/power_supply.h > [2] Documentation/power/power_supply_class.txt > > Fixes: fb972873a767 ("[BATTERY] One Laptop Per Child power/battery driver") > Cc: stable@vger.kernel.org > Signed-off-by: Lubomir Rintel > Acked-by: Pavel Machek > > --- This is queued to next. -- Sebastian > Changes since v1: > - Add Fixes tag and an Ack > > drivers/power/supply/olpc_battery.c | 4 ++-- > 1 file changed, 2 insertions(+), 2 deletions(-) > > diff --git a/drivers/power/supply/olpc_battery.c b/drivers/power/supply/olpc_battery.c > index 6da79ae14860..5a97e42a3547 100644 > --- a/drivers/power/supply/olpc_battery.c > +++ b/drivers/power/supply/olpc_battery.c > @@ -428,14 +428,14 @@ static int olpc_bat_get_property(struct power_supply *psy, > if (ret) > return ret; > > - val->intval = (s16)be16_to_cpu(ec_word) * 100 / 256; > + val->intval = (s16)be16_to_cpu(ec_word) * 10 / 256; > break; > case POWER_SUPPLY_PROP_TEMP_AMBIENT: > ret = olpc_ec_cmd(EC_AMB_TEMP, NULL, 0, (void *)&ec_word, 2); > if (ret) > return ret; > > - val->intval = (int)be16_to_cpu(ec_word) * 100 / 256; > + val->intval = (int)be16_to_cpu(ec_word) * 10 / 256; > break; > case POWER_SUPPLY_PROP_CHARGE_COUNTER: > ret = olpc_ec_cmd(EC_BAT_ACR, NULL, 0, (void *)&ec_word, 2); > -- > 2.19.1 >