On Fri, May 23, 2014 at 03:51:10PM +0800, Chen-Yu Tsai wrote: > The N factor for PLL6 counts from 1 to 32, as specified in the A23 > manual, and shown in Allwinner's original code. > > This patch fixes the N factor in the clock driver, as well as the > comment describing it. > > Signed-off-by: Chen-Yu Tsai Acked-by: Maxime Ripard Thanks, Maxime -- Maxime Ripard, Free Electrons Embedded Linux, Kernel and Android engineering http://free-electrons.com