On Wed, Mar 30, 2016 at 10:03:28PM +0200, Boris Brezillon wrote: > Currently the PWM core mixes the current PWM state with the per-platform > reference config (specified through the PWM lookup table, DT definition or > directly hardcoded in PWM drivers). > > Create a pwm_args struct to store this reference config, so that PWM users > can differentiate the current config from the reference one. > > Patch all places where pwm->args should be initialized. We keep the > pwm_set_polarity/period() calls until all PWM users are patched to > use pwm_args instead of pwm_get_period/polarity(). Perhaps a helper would be useful? Something like: static inline void pwm_apply_args(struct pwm_device *pwm, const struct pwm_args *args) { pwm_set_duty_cycle(pwm, args->duty_cycle); pwm_set_period(pwm, args->period); } ? That would make it slightly easier to get rid of it again after all clients have been converted. With the exception of pwm-clps711x all of these args are set at of_xlate time (for DT) or from the lookup table in pwm_get() (for non-DT), so it might even be possible to move this call to the core, so that removal of it will be a one-liner. Thierry