On Sat, Apr 08, 2017 at 12:19:04AM +0800, Icenowy Zheng wrote: > The CLK_NUMBER value of PRCM CCU is wrongly set to (CLK_APB0_PWD + 1), > which prevented the IR mod clock from being set up. > > Change it to (CLK_IR + 1) in order to correctly get IR mod set up. Applied both, thanks. Maxime -- Maxime Ripard, Free Electrons Embedded Linux and Kernel engineering http://free-electrons.com