linux-kernel.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
From: Andy Shevchenko <andy.shevchenko@gmail.com>
To: Henning Schild <henning.schild@siemens.com>
Cc: Linux Kernel Mailing List <linux-kernel@vger.kernel.org>,
	Linux LED Subsystem <linux-leds@vger.kernel.org>,
	Platform Driver <platform-driver-x86@vger.kernel.org>,
	linux-watchdog@vger.kernel.org,
	Srikanth Krishnakar <skrishnakar@gmail.com>,
	Jan Kiszka <jan.kiszka@siemens.com>,
	Gerd Haeussler <gerd.haeussler.ext@siemens.com>,
	Guenter Roeck <linux@roeck-us.net>,
	Wim Van Sebroeck <wim@linux-watchdog.org>,
	Mark Gross <mgross@linux.intel.com>,
	Hans de Goede <hdegoede@redhat.com>, Pavel Machek <pavel@ucw.cz>,
	Michael Haener <michael.haener@siemens.com>
Subject: Re: [PATCH 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs
Date: Thu, 4 Mar 2021 11:50:52 +0200	[thread overview]
Message-ID: <CAHp75Vf1gkb+qWhv7a5Q3Bf-brDkMsOKdFo4ckSpG2e-7bqWng@mail.gmail.com> (raw)
In-Reply-To: <20210302163309.25528-5-henning.schild@siemens.com>

On Thu, Mar 4, 2021 at 9:27 AM Henning Schild
<henning.schild@siemens.com> wrote:

> Siemens industrial PCs unfortunately can not always be properly
> identified the way we used to. An earlier commit introduced code that
> allows proper identification without looking at DMI strings that could
> differ based on product branding.
> Switch over to that proper way and revert commits that used to collect
> the machines based on unstable strings.

> +#include <linux/platform_data/x86/simatic-ipc.h>

> +static int pmc_clk_is_critical(const struct dmi_system_id *d)
> +{
> +       int ret = true;
> +       u32 station_id;
> +
> +       if (!strcmp(d->ident, "SIEMENS AG")) {
> +               if (dmi_walk(simatic_ipc_find_dmi_entry_helper, &station_id))
> +                       ret = false;
> +               else
> +                       ret = (station_id == SIMATIC_IPC_IPC227E ||
> +                              station_id == SIMATIC_IPC_IPC277E);
> +       }
> +
> +       return ret;

Much easier to rewrite it as

if (strcmp(...)) // BTW, do we have a dmi_* helper for that?
  return true;

if (dmi_walk)
  return false;

return station_id == || ...;

> +}

Maybe instead you can rewrite it as a callback in DMI table which
changes a (global, yeah) variable that you simply reassign...



>         if (d) {
> -               clk_data->critical = true;
> -               pr_info("%s critclks quirk enabled\n", d->ident);
> +               clk_data->critical = pmc_clk_is_critical(d);
> +               if (clk_data->critical)
> +                       pr_info("%s critclks quirk enabled\n", d->ident);
>         }

...somewhere here?

Like
  clk_data->critical = global_var;
  if (...)
    pr_info();

It seems it will reduce burden on a callback by dropping strcmp() call.

-- 
With Best Regards,
Andy Shevchenko

  reply	other threads:[~2021-03-04  9:52 UTC|newest]

Thread overview: 46+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-03-02 16:33 [PATCH 0/4] add device drivers for Siemens Industrial PCs Henning Schild
2021-03-02 16:33 ` [PATCH 1/4] platform/x86: simatic-ipc: add main driver for Siemens devices Henning Schild
2021-03-04 10:11   ` Andy Shevchenko
2021-03-04 13:47     ` Hans de Goede
2021-03-05 15:42       ` Andy Shevchenko
2021-03-05 16:14         ` Hans de Goede
2021-03-05 16:25           ` Andy Shevchenko
2021-03-05 16:36             ` Hans de Goede
2021-03-05 16:41             ` Andy Shevchenko
2021-03-05 16:47               ` Andy Shevchenko
2021-03-05 16:42         ` Henning Schild
2021-03-05 17:17           ` Andy Shevchenko
2021-03-05 17:44             ` Andy Shevchenko
2021-03-08 12:57               ` Henning Schild
2021-03-08 13:43                 ` Andy Shevchenko
2021-03-04 19:42     ` Henning Schild
2021-03-05 15:46       ` Andy Shevchenko
2021-03-05 16:31         ` Henning Schild
2021-03-04 14:03   ` Hans de Goede
2021-03-02 16:33 ` [PATCH 2/4] leds: simatic-ipc-leds: add new driver for Siemens Industial PCs Henning Schild
2021-03-02 20:54   ` Pavel Machek
2021-03-03 13:11     ` Henning Schild
2021-03-03 19:31       ` Pavel Machek
2021-03-03 20:48         ` Henning Schild
2021-03-03 20:56           ` Henning Schild
2021-03-05 18:25             ` Henning Schild
2021-03-06 12:54               ` Henning Schild
2021-03-06 13:06                 ` Henning Schild
2021-03-15 11:49                   ` Pavel Machek
2021-03-15 11:41               ` Pavel Machek
2021-03-03 17:37     ` Henning Schild
2021-03-03 17:40       ` Pavel Machek
2021-03-03 18:49         ` Henning Schild
2021-03-03 19:27           ` Pavel Machek
2021-03-02 16:33 ` [PATCH 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs Henning Schild
2021-03-02 18:38   ` Guenter Roeck
2021-03-03 14:21     ` Henning Schild
2021-03-03 14:49       ` Jan Kiszka
2021-03-08 15:20       ` Henning Schild
     [not found]   ` <CAHp75VdUXWDg-2o8fmeo7EoMtRLfCnFOw5ptwjXTv9fKMmHv2A@mail.gmail.com>
2021-03-04  9:00     ` Henning Schild
2021-03-02 16:33 ` [PATCH 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs Henning Schild
2021-03-04  9:50   ` Andy Shevchenko [this message]
2021-03-04 10:19 ` [PATCH 0/4] add device drivers for Siemens Industrial PCs Andy Shevchenko
2021-03-04 10:20   ` Andy Shevchenko
2021-03-04 19:26     ` Henning Schild
2021-03-04 19:14   ` Henning Schild

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=CAHp75Vf1gkb+qWhv7a5Q3Bf-brDkMsOKdFo4ckSpG2e-7bqWng@mail.gmail.com \
    --to=andy.shevchenko@gmail.com \
    --cc=gerd.haeussler.ext@siemens.com \
    --cc=hdegoede@redhat.com \
    --cc=henning.schild@siemens.com \
    --cc=jan.kiszka@siemens.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-leds@vger.kernel.org \
    --cc=linux-watchdog@vger.kernel.org \
    --cc=linux@roeck-us.net \
    --cc=mgross@linux.intel.com \
    --cc=michael.haener@siemens.com \
    --cc=pavel@ucw.cz \
    --cc=platform-driver-x86@vger.kernel.org \
    --cc=skrishnakar@gmail.com \
    --cc=wim@linux-watchdog.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).