Subject: Re: [PATCH RFC 0/8] Introduce warming in thermal framework
Date: Mon, 19 Oct 2020 14:42:48 -0400	[thread overview]
Message-ID: <CALD-y_wQeuUq=0+_TGWYwOAcM4zdmGbtCMYZ+Oa587HtzHHqVQ@mail.gmail.com> (raw)
In-Reply-To: <20200917032226.820371-1-thara.gopinath@linaro.org>

On Wed, 16 Sep 2020 at 23:22, Thara Gopinath <thara.gopinath@linaro.org> wrote:
>
> Thermal framework today supports monitoring for rising temperatures and
> subsequently initiating cooling action in case of a thermal trip point
> being crossed. There are scenarios where a SoC need warming mitigating
> action to be activated if the temperature falls below a cetain permissible
> limit.  Since warming action can be considered mirror opposite of cooling
> action, most of the thermal framework can be re-used to achieve this. The
> key assumption in this patch series is that a device can act either as a
> warming device or a cooling device and not as both.
>
> In order to support warming three extensions are needed in the thermal
> framework.
>
> 1. Indication that a trip point is being monitored for falling temperature
> and not rising temperature. We discussed two different ways to achieve this
> during LPC. First option is to introduce a new trip type to indicate that a
> trip is a cold trip(THERMAL_TRIP_COLD). The second option is to introduce a
> new property for trip point that will indicate whether a trip point is
> being monitored for rising temperature or falling temperature. The patch
> series(patches 1-4) chooses the second approach since it allows trip points
> of any type to be monitored for rising or falling temperature.Also this was
> the preferred approach when discussed during LPC. The approach that
> introduces a new cold trip type was posted on the list earlier as a RFC and
> can be found at [1].
>
> 2. Extend the exisitng governors to handle monitoring of falling
> temperature. The patch series(patches 5 & 6) extends the step wise governor
> to monitor the falling temperature.Other governors return doing nothing if
> the trip point they are being called for is being monitored for falling
> temperature. The governors' mitigate function is called "throttle" in the
> thermal framework and with this patch series it is a misnomer as the
> function is called for both throttling and warming up. Ideally
> "throttle" should be renamed to "mitigate" to improve readability of code.
> The renaming is not part of this series.
>
> 3. Finally, the cooling device framework itself can be reused for a warming
> device. As stated before a device can act either as a warming device or a
> cooling device and not as both.  With this the cooling state in the
> framework can be considered as mitigating state with 0 as the state with no
> thermal mitigation and higher the number higher the thermal mitigation.
> Again what affects the code readability and comprehension is the term
> "cooling" which is a misnomer here. Ideally the term "cooling" should be
> renamed to "mitigating" and hence thermal_cooling_device will become
> thermal_mitgating_device. The renaming is not part of the patch series as
> even though the renaming is a simple search-replace, it will change a lot
> of files.  The patch series(patches 7 & 8) instead introduces a minimal set
> of _warming_device_ apis to register and unregister warming devices which
> internally is identical to the _cooling_device_ counterpart.

Gentle ping for review..

>
> 1. https://lkml.org/lkml/2020/7/10/639
>
> Thara Gopinath (8):
>   dt-bindings: thermal: Introduce monitor-falling parameter to thermal
>     trip point binding
>   thermal: Introduce new property monitor_type for trip point.
>   thermal: thermal_of: Extend thermal dt driver to support
>     bi-directional monitoring of a thermal trip point.
>   thermal:core:Add genetlink notifications for monitoring falling
>     temperature
>   thermal: gov_step_wise: Extend thermal step-wise governor to monitor
>     falling temperature.
>   thermal: Modify thermal governors to do nothing for trip points being
>     monitored for falling temperature
>   thermal:core: Add is_warming_dev and supporting warming device api's
>     to the cooling dev framework.
>   soc:qcom:qcom_aoss: Change cooling_device_register to
>     warming_device_register
>
>  .../bindings/thermal/thermal-zones.yaml       |   7 ++
>  drivers/soc/qcom/qcom_aoss.c                  |   6 +-
>  drivers/thermal/gov_bang_bang.c               |  12 ++
>  drivers/thermal/gov_fair_share.c              |  12 ++
>  drivers/thermal/gov_power_allocator.c         |  12 ++
>  drivers/thermal/gov_step_wise.c               |  62 +++++++---
>  drivers/thermal/thermal_core.c                | 113 +++++++++++++++---
>  drivers/thermal/thermal_core.h                |   2 +
>  drivers/thermal/thermal_of.c                  |  22 ++++
>  include/linux/thermal.h                       |   9 ++
>  include/uapi/linux/thermal.h                  |   5 +
>  11 files changed, 226 insertions(+), 36 deletions(-)
>
> --
> 2.25.1
>


-- 
Warm Regards
Thara

  parent reply	other threads:[~2020-10-19 18:43 UTC|newest]

Thread overview: 13+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2020-09-17  3:22 [PATCH RFC 0/8] Introduce warming in thermal framework Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 1/8] dt-bindings: thermal: Introduce monitor-falling parameter to thermal trip point binding Thara Gopinath
2020-09-23 16:03   ` Rob Herring
2020-09-28 11:21     ` Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 2/8] thermal: Introduce new property monitor_type for trip point Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 3/8] thermal: thermal_of: Extend thermal dt driver to support bi-directional monitoring of a thermal " Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 4/8] thermal:core:Add genetlink notifications for monitoring falling temperature Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 5/8] thermal: gov_step_wise: Extend thermal step-wise governor to monitor " Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 6/8] thermal: Modify thermal governors to do nothing for trip points being monitored for " Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 7/8] thermal:core: Add is_warming_dev and supporting warming device api's to the cooling dev framework Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 8/8] soc:qcom:qcom_aoss: Change cooling_device_register to warming_device_register Thara Gopinath
2020-10-19 18:42 ` Thara Gopinath [this message]
2020-10-19 19:22   ` [PATCH RFC 0/8] Introduce warming in thermal framework Daniel Lezcano

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to='CALD-y_wQeuUq=0+_TGWYwOAcM4zdmGbtCMYZ+Oa587HtzHHqVQ@mail.gmail.com' \
    --to=thara.gopinath@linaro.org \
    --cc=agross@kernel.org \
    --cc=amitk@kernel.org \
    --cc=bjorn.andersson@linaro.org \
    --cc=daniel.lezcano@linaro.org \
    --cc=devicetree@vger.kernel.org \
    --cc=linux-arm-msm@vger.kernel.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pm@vger.kernel.org \
    --cc=lukasz.luba@arm.com \
    --cc=robh+dt@kernel.org \
    --cc=rui.zhang@intel.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).