On Tue, Mar 02, 2021 at 03:24:58PM +0300, Dmitry Osipenko wrote: > The tegra_powergate_power_up() has a typo in the error code path where it > will try to disable clocks twice, fix it. In practice that error never > happens, so this is a minor correction. > > Tested-by: Peter Geis # Ouya T30 > Tested-by: Nicolas Chauvet # PAZ00 T20 and TK1 T124 > Tested-by: Matt Merhar # Ouya T30 > Signed-off-by: Dmitry Osipenko > --- > drivers/soc/tegra/pmc.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) Applied, thanks. Thierry