From: Henning Schild <henning.schild@siemens.com>
To: linux-kernel@vger.kernel.org, linux-leds@vger.kernel.org,
	platform-driver-x86@vger.kernel.org,
	linux-watchdog@vger.kernel.org
Cc: Srikanth Krishnakar <skrishnakar@gmail.com>,
	Jan Kiszka <jan.kiszka@siemens.com>,
	Henning Schild <henning.schild@siemens.com>,
	Gerd Haeussler <gerd.haeussler.ext@siemens.com>,
	Guenter Roeck <linux@roeck-us.net>,
	Wim Van Sebroeck <wim@linux-watchdog.org>,
	Mark Gross <mgross@linux.intel.com>,
	Hans de Goede <hdegoede@redhat.com>, Pavel Machek <pavel@ucw.cz>,
	Andy Shevchenko <andy.shevchenko@gmail.com>
Subject: [PATCH] platform/x86: pmc_atom: use callback for all dmi quirk entries
Date: Mon, 15 Mar 2021 15:58:55 +0100	[thread overview]
Message-ID: <20210315145855.17174-1-henning.schild@siemens.com> (raw)
In-Reply-To: <ef5fe493-285d-145c-8d05-7f9bd0cb47c5@redhat.com>

Introduce a global variable to remember the matching entry for later
printing. Also having a callback allows to stop matching after the first
hit.

Signed-off-by: Henning Schild <henning.schild@siemens.com>
---
 drivers/platform/x86/pmc_atom.c | 26 ++++++++++++++++++++------
 1 file changed, 20 insertions(+), 6 deletions(-)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index 38542d547f29..d0f74856cd8b 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -364,8 +364,16 @@ static void pmc_dbgfs_register(struct pmc_dev *pmc)
 #endif /* CONFIG_DEBUG_FS */
 
 static bool pmc_clk_is_critical = true;
+static const struct dmi_system_id *dmi_critical;
 
-static int siemens_clk_is_critical(const struct dmi_system_id *d)
+static int dmi_callback(const struct dmi_system_id *d)
+{
+	dmi_critical = d;
+
+	return 1;
+}
+
+static int dmi_callback_siemens(const struct dmi_system_id *d)
 {
 	u32 st_id;
 
@@ -373,7 +381,7 @@ static int siemens_clk_is_critical(const struct dmi_system_id *d)
 		goto out;
 
 	if (st_id == SIMATIC_IPC_IPC227E || st_id == SIMATIC_IPC_IPC277E)
-		return 1;
+		return dmi_callback(d);
 
 out:
 	pmc_clk_is_critical = false;
@@ -388,6 +396,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk0 is used for an external HSIC USB HUB */
 		.ident = "MPL CEC1x",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"),
@@ -396,6 +405,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */
 		.ident = "Lex 3I380D",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
@@ -404,6 +414,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Lex 2I385SW",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "2I385SW"),
@@ -412,6 +423,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB3163",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
@@ -420,6 +432,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB4063",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_BOARD_NAME, "CB4063"),
@@ -428,6 +441,7 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB6263",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
@@ -436,13 +450,14 @@ static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB6363",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
 		},
 	},
 	{
-		.callback = siemens_clk_is_critical,
+		.callback = dmi_callback_siemens,
 		.ident = "SIEMENS AG",
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
@@ -457,7 +472,6 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
 {
 	struct platform_device *clkdev;
 	struct pmc_clk_data *clk_data;
-	const struct dmi_system_id *d;
 
 	clk_data = kzalloc(sizeof(*clk_data), GFP_KERNEL);
 	if (!clk_data)
@@ -468,8 +482,8 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
 	if (dmi_check_system(critclk_systems)) {
 		clk_data->critical = pmc_clk_is_critical;
 		if (clk_data->critical) {
-			d = dmi_first_match(critclk_systems);
-			pr_info("%s critclks quirk enabled\n", d->ident);
+			pr_info("%s critclks quirk enabled\n",
+				dmi_critical->ident);
 		}
 	}
 
-- 
2.26.2


  parent reply	other threads:[~2021-03-15 15:00 UTC|newest]

Thread overview: 43+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-03-15  9:57 [PATCH v2 0/4] add device drivers for Siemens Industrial PCs Henning Schild
2021-03-15  9:57 ` [PATCH v2 1/4] platform/x86: simatic-ipc: add main driver for Siemens devices Henning Schild
2021-03-15 10:31   ` Andy Shevchenko
2021-03-15 16:30     ` Henning Schild
2021-03-17 19:13     ` Henning Schild
2021-03-17 20:03       ` Hans de Goede
2021-03-18 11:30         ` Enrico Weigelt, metux IT consult
2021-03-18 11:45           ` Hans de Goede
2021-03-26  9:55             ` Henning Schild
2021-03-26 12:21               ` Hans de Goede
2021-03-15  9:57 ` [PATCH v2 2/4] leds: simatic-ipc-leds: add new driver for Siemens Industial PCs Henning Schild
2021-03-15 10:48   ` Andy Shevchenko
2021-03-15 11:19     ` Pavel Machek
2021-03-15 11:26       ` Andy Shevchenko
2021-03-15 12:40       ` Henning Schild
2021-03-18 11:38       ` Enrico Weigelt, metux IT consult
2021-03-27  9:46         ` Henning Schild
2021-04-01 16:20           ` Enrico Weigelt, metux IT consult
2021-03-27  9:56       ` Henning Schild
2021-03-18 10:27     ` Enrico Weigelt, metux IT consult
2021-03-18 12:40       ` Alexander Dahl
2021-03-23 17:45         ` Henning Schild
2021-03-26 16:33     ` Henning Schild
2021-03-18 10:25   ` Enrico Weigelt, metux IT consult
2021-03-27 11:16     ` Henning Schild
2021-03-27 11:41       ` Henning Schild
2021-03-15  9:57 ` [PATCH v2 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs Henning Schild
2021-03-15 15:10   ` Guenter Roeck
2021-03-29 16:28     ` Henning Schild
2021-03-15  9:57 ` [PATCH v2 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs Henning Schild
2021-03-15 10:14   ` Henning Schild
2021-03-15 10:19     ` Hans de Goede
2021-03-15 12:09       ` Henning Schild
2021-03-15 14:58       ` Henning Schild [this message]
2021-03-15 16:31         ` [PATCH] platform/x86: pmc_atom: use callback for all dmi quirk entries Hans de Goede
2021-03-15 17:00           ` Henning Schild
2021-03-15 18:01             ` Hans de Goede
2021-03-16  5:47               ` Henning Schild
2021-03-16  9:43                 ` Hans de Goede
2021-03-15 13:25   ` [PATCH v2 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs kernel test robot
2021-03-15 10:55 ` [PATCH v2 0/4] add device drivers for Siemens Industrial PCs Andy Shevchenko
2021-03-15 16:08   ` Henning Schild
2021-08-02  9:21   ` Henning Schild

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20210315145855.17174-1-henning.schild@siemens.com \
    --to=henning.schild@siemens.com \
    --cc=andy.shevchenko@gmail.com \
    --cc=gerd.haeussler.ext@siemens.com \
    --cc=hdegoede@redhat.com \
    --cc=jan.kiszka@siemens.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-leds@vger.kernel.org \
    --cc=linux-watchdog@vger.kernel.org \
    --cc=linux@roeck-us.net \
    --cc=mgross@linux.intel.com \
    --cc=pavel@ucw.cz \
    --cc=platform-driver-x86@vger.kernel.org \
    --cc=skrishnakar@gmail.com \
    --cc=wim@linux-watchdog.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).