[03/66] ALSA: oxygen: fix analog capture on Claro halo cards
diff mbox series

Message ID 20101022183556.522657637@clark.site
State New, archived
Headers show
Series
  • 2.6.32.25-stable review
Related show

Commit Message

Greg KH Oct. 22, 2010, 6:34 p.m. UTC
2.6.32-stable review patch.  If anyone has any objections, please let us know.

------------------

From: Erik J. Staab <ejs@insightbb.com>

commit 0873a5ae747847ee55a63db409dff3476e45bcd9 upstream.

On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input.  Using the default first input, which isn't connected
to anything, would result in silence.

Signed-off-by: Erik J. Staab <ejs@insightbb.com>
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>

---
 sound/pci/oxygen/oxygen.c |    4 ++++
 1 file changed, 4 insertions(+)



--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Patch
diff mbox series

--- a/sound/pci/oxygen/oxygen.c
+++ b/sound/pci/oxygen/oxygen.c
@@ -393,6 +393,10 @@  static int __devinit get_oxygen_model(st
 		chip->model.suspend = claro_suspend;
 		chip->model.resume = claro_resume;
 		chip->model.set_adc_params = set_ak5385_params;
+		chip->model.device_config = PLAYBACK_0_TO_I2S |
+					    PLAYBACK_1_TO_SPDIF |
+					    CAPTURE_0_FROM_I2S_2 |
+					    CAPTURE_1_FROM_SPDIF;
 		break;
 	}
 	if (id->driver_data == MODEL_MERIDIAN ||