platform-driver-x86.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
From: Henning Schild <henning.schild@siemens.com>
To: "Enrico Weigelt, metux IT consult" <lkml@metux.net>,
	Andy Shevchenko <andy.shevchenko@gmail.com>
Cc: <linux-kernel@vger.kernel.org>, <linux-leds@vger.kernel.org>,
	<platform-driver-x86@vger.kernel.org>,
	<linux-watchdog@vger.kernel.org>,
	Srikanth Krishnakar <skrishnakar@gmail.com>,
	Jan Kiszka <jan.kiszka@siemens.com>,
	Gerd Haeussler <gerd.haeussler.ext@siemens.com>,
	Guenter Roeck <linux@roeck-us.net>,
	Wim Van Sebroeck <wim@linux-watchdog.org>,
	Mark Gross <mgross@linux.intel.com>,
	Hans de Goede <hdegoede@redhat.com>, Pavel Machek <pavel@ucw.cz>
Subject: Re: [PATCH v3 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs
Date: Mon, 12 Apr 2021 17:35:31 +0200	[thread overview]
Message-ID: <20210412173531.4140e461@md1za8fc.ad001.siemens.net> (raw)
In-Reply-To: <ffdfe9a9-ab17-18af-300e-062b79d132f3@metux.net>

Am Thu, 1 Apr 2021 18:15:41 +0200
schrieb "Enrico Weigelt, metux IT consult" <lkml@metux.net>:

> On 29.03.21 19:49, Henning Schild wrote:
> 
> Hi,
> 
> > This driver adds initial support for several devices from Siemens.
> > It is based on a platform driver introduced in an earlier commit.  
> 
> Where does the wdt actually come from ?
> 
> Is it in the SoC ? (which SoC exactly). SoC-builtin wdt is a pretty 
> usual case.
> 
> Or some external chip ?
> 
> The code smells a bit like two entirely different wdt's that just have
> some similarities. If that's the case, I'd rather split it into two
> separate drivers and let the parent driver (board file) instantiate
> the correct one.

In fact they are the same watchdog device. The only difference is the
"secondary enable" which controls whether the watchdog causes a reboot
or just raises an alarm. The alarm feature is not even implemented in
the given driver, we just enable that secondary enable regardless.

In one range of devices (227E) that second enable is part of a
pio-based control register. On the other range (427E) it unfortunately
is a P2SB gpio, which gets us right into the discussion we have around
the LEDs.
With that i have my doubts that two drivers would be the way to go,
most likely not. 

Only that i have no clue which pinctrl driver should be used here. My
guess is "sunrisepoint" because the CPUs are "SkyLake" i.e. i5-6442EQ,
i3-6102E
And "grep INT344B /sys/firmware/acpi/tables/DSDT" matches. I booted a
kernel patched with the series from Andy but the "pinctrl-sunrisepoint"
does not seem to even claim the memory. Still trying to understand how
to make use of these pinctrl drivers they are in place but i lack
example users (drivers). If they should be available in sysfs, i might
be looking at the wrong place ... /sys/class/gpio/ does not list
anything

regards,
Henning



> 
> --mtx
> 


  parent reply	other threads:[~2021-04-12 15:47 UTC|newest]

Thread overview: 40+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-03-29 17:49 [PATCH v3 0/4] add device drivers for Siemens Industrial PCs Henning Schild
2021-03-29 17:49 ` [PATCH v3 1/4] platform/x86: simatic-ipc: add main driver for Siemens devices Henning Schild
2021-11-26 12:39   ` Henning Schild
2021-03-29 17:49 ` [PATCH v3 2/4] leds: simatic-ipc-leds: add new driver for Siemens Industial PCs Henning Schild
2021-03-30 11:04   ` Andy Shevchenko
2021-03-30 11:58     ` Henning Schild
2021-03-30 12:15       ` Andy Shevchenko
2021-03-30 12:30         ` Henning Schild
2021-03-30 12:41           ` Andy Shevchenko
2021-03-30 15:23             ` Henning Schild
2021-03-31 15:40               ` Andy Shevchenko
2021-04-01 10:44                 ` Henning Schild
2021-04-01 11:04                   ` Andy Shevchenko
2021-04-12 11:56                     ` Henning Schild
2021-05-05 14:58                       ` Enrico Weigelt, metux IT consult
2021-04-12 15:15                     ` Henning Schild
2021-11-26 13:28     ` Henning Schild
2021-11-26 14:02       ` Andy Shevchenko
2021-11-26 14:44         ` Henning Schild
2021-11-26 14:59           ` Andy Shevchenko
2021-11-26 19:54             ` Henning Schild
2021-11-25 17:11   ` Henning Schild
2021-03-29 17:49 ` [PATCH v3 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs Henning Schild
2021-04-01 16:15   ` Enrico Weigelt, metux IT consult
2021-04-06 14:52     ` Henning Schild
2021-04-07  8:53       ` Andy Shevchenko
2021-04-07 12:17         ` Guenter Roeck
2021-11-26 13:18           ` Henning Schild
2021-04-12 15:35     ` Henning Schild [this message]
2021-04-12 16:06       ` Guenter Roeck
2021-04-12 16:17         ` Henning Schild
2021-11-25 17:08   ` Henning Schild
2021-11-25 17:10   ` Henning Schild
2021-03-29 17:49 ` [PATCH v3 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs Henning Schild
2021-03-29 18:00 ` [PATCH v3 0/4] add device drivers for Siemens Industrial PCs Henning Schild
2021-04-07 11:36 ` Hans de Goede
2021-04-12 11:27   ` Henning Schild
2021-07-12 11:35   ` Henning Schild
2021-07-12 12:09     ` Andy Shevchenko
2021-07-12 16:11       ` Henning Schild

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20210412173531.4140e461@md1za8fc.ad001.siemens.net \
    --to=henning.schild@siemens.com \
    --cc=andy.shevchenko@gmail.com \
    --cc=gerd.haeussler.ext@siemens.com \
    --cc=hdegoede@redhat.com \
    --cc=jan.kiszka@siemens.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-leds@vger.kernel.org \
    --cc=linux-watchdog@vger.kernel.org \
    --cc=linux@roeck-us.net \
    --cc=lkml@metux.net \
    --cc=mgross@linux.intel.com \
    --cc=pavel@ucw.cz \
    --cc=platform-driver-x86@vger.kernel.org \
    --cc=skrishnakar@gmail.com \
    --cc=wim@linux-watchdog.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).