All of lore.kernel.org
 help / color / mirror / Atom feed
From: Tony Lindgren <tony@atomide.com>
To: linux-omap@vger.kernel.org
Cc: linux-arm-kernel@lists.infradead.org
Subject: [PATCH 09/11] ARM: OMAP2+: Drop legacy platform data for omap4 l4_cfg
Date: Mon,  8 Mar 2021 15:46:25 +0200	[thread overview]
Message-ID: <20210308134627.13056-10-tony@atomide.com> (raw)
In-Reply-To: <20210308134627.13056-1-tony@atomide.com>

We can now probe interconnects with simple-pm-bus and genpd.

Signed-off-by: Tony Lindgren <tony@atomide.com>
---
 arch/arm/mach-omap2/omap_hwmod_44xx_data.c | 98 ----------------------
 1 file changed, 98 deletions(-)

diff --git a/arch/arm/mach-omap2/omap_hwmod_44xx_data.c b/arch/arm/mach-omap2/omap_hwmod_44xx_data.c
--- a/arch/arm/mach-omap2/omap_hwmod_44xx_data.c
+++ b/arch/arm/mach-omap2/omap_hwmod_44xx_data.c
@@ -92,27 +92,6 @@ static struct omap_hwmod omap44xx_l3_main_3_hwmod = {
 	},
 };
 
-/*
- * 'l4' class
- * instance(s): l4_abe, l4_cfg
- */
-static struct omap_hwmod_class omap44xx_l4_hwmod_class = {
-	.name	= "l4",
-};
-
-/* l4_cfg */
-static struct omap_hwmod omap44xx_l4_cfg_hwmod = {
-	.name		= "l4_cfg",
-	.class		= &omap44xx_l4_hwmod_class,
-	.clkdm_name	= "l4_cfg_clkdm",
-	.prcm = {
-		.omap4 = {
-			.clkctrl_offs = OMAP4_CM_L4CFG_L4_CFG_CLKCTRL_OFFSET,
-			.context_offs = OMAP4_RM_L4CFG_L4_CFG_CONTEXT_OFFSET,
-		},
-	},
-};
-
 /*
  * 'ocp_wp_noc' class
  * instance(s): ocp_wp_noc
@@ -168,29 +147,6 @@ static struct omap_hwmod omap44xx_ocmc_ram_hwmod = {
 	},
 };
 
-
-/*
- * 'prcm' class
- * power and reset manager (part of the prcm infrastructure) + clock manager 2
- * + clock manager 1 (in always on power domain) + local prm in mpu
- */
-
-static struct omap_hwmod_class omap44xx_prcm_hwmod_class = {
-	.name	= "prcm",
-};
-
-/* cm_core */
-static struct omap_hwmod omap44xx_cm_core_hwmod = {
-	.name		= "cm_core",
-	.class		= &omap44xx_prcm_hwmod_class,
-	.flags		= HWMOD_NO_IDLEST,
-	.prcm = {
-		.omap4 = {
-			.flags = HWMOD_OMAP4_NO_CONTEXT_LOSS_BIT,
-		},
-	},
-};
-
 /*
  * 'sl2if' class
  * shared level 2 memory interface
@@ -242,14 +198,6 @@ static struct omap_hwmod_ocp_if omap44xx_l3_main_2__l3_main_1 = {
 	.user		= OCP_USER_MPU | OCP_USER_SDMA,
 };
 
-/* l4_cfg -> l3_main_1 */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__l3_main_1 = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_l3_main_1_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
 /* l3_main_1 -> l3_main_2 */
 static struct omap_hwmod_ocp_if omap44xx_l3_main_1__l3_main_2 = {
 	.master		= &omap44xx_l3_main_1_hwmod,
@@ -258,14 +206,6 @@ static struct omap_hwmod_ocp_if omap44xx_l3_main_1__l3_main_2 = {
 	.user		= OCP_USER_MPU,
 };
 
-/* l4_cfg -> l3_main_2 */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__l3_main_2 = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_l3_main_2_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
 /* l3_main_1 -> l3_main_3 */
 static struct omap_hwmod_ocp_if omap44xx_l3_main_1__l3_main_3 = {
 	.master		= &omap44xx_l3_main_1_hwmod,
@@ -282,30 +222,6 @@ static struct omap_hwmod_ocp_if omap44xx_l3_main_2__l3_main_3 = {
 	.user		= OCP_USER_MPU | OCP_USER_SDMA,
 };
 
-/* l4_cfg -> l3_main_3 */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__l3_main_3 = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_l3_main_3_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
-/* l3_main_1 -> l4_cfg */
-static struct omap_hwmod_ocp_if omap44xx_l3_main_1__l4_cfg = {
-	.master		= &omap44xx_l3_main_1_hwmod,
-	.slave		= &omap44xx_l4_cfg_hwmod,
-	.clk		= "l3_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
-/* l4_cfg -> ocp_wp_noc */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__ocp_wp_noc = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_ocp_wp_noc_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
 /* l3_main_2 -> ocmc_ram */
 static struct omap_hwmod_ocp_if omap44xx_l3_main_2__ocmc_ram = {
 	.master		= &omap44xx_l3_main_2_hwmod,
@@ -314,14 +230,6 @@ static struct omap_hwmod_ocp_if omap44xx_l3_main_2__ocmc_ram = {
 	.user		= OCP_USER_MPU | OCP_USER_SDMA,
 };
 
-/* l4_cfg -> cm_core */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__cm_core = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_cm_core_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
 /* l3_main_2 -> sl2if */
 static struct omap_hwmod_ocp_if __maybe_unused omap44xx_l3_main_2__sl2if = {
 	.master		= &omap44xx_l3_main_2_hwmod,
@@ -334,16 +242,10 @@ static struct omap_hwmod_ocp_if *omap44xx_hwmod_ocp_ifs[] __initdata = {
 	&omap44xx_l3_main_3__l3_instr,
 	&omap44xx_ocp_wp_noc__l3_instr,
 	&omap44xx_l3_main_2__l3_main_1,
-	&omap44xx_l4_cfg__l3_main_1,
 	&omap44xx_l3_main_1__l3_main_2,
-	&omap44xx_l4_cfg__l3_main_2,
 	&omap44xx_l3_main_1__l3_main_3,
 	&omap44xx_l3_main_2__l3_main_3,
-	&omap44xx_l4_cfg__l3_main_3,
-	&omap44xx_l3_main_1__l4_cfg,
-	&omap44xx_l4_cfg__ocp_wp_noc,
 	&omap44xx_l3_main_2__ocmc_ram,
-	&omap44xx_l4_cfg__cm_core,
 	/* &omap44xx_l3_main_2__sl2if, */
 	NULL,
 };
-- 
2.30.1

WARNING: multiple messages have this Message-ID (diff)
From: Tony Lindgren <tony@atomide.com>
To: linux-omap@vger.kernel.org
Cc: linux-arm-kernel@lists.infradead.org
Subject: [PATCH 09/11] ARM: OMAP2+: Drop legacy platform data for omap4 l4_cfg
Date: Mon,  8 Mar 2021 15:46:25 +0200	[thread overview]
Message-ID: <20210308134627.13056-10-tony@atomide.com> (raw)
In-Reply-To: <20210308134627.13056-1-tony@atomide.com>

We can now probe interconnects with simple-pm-bus and genpd.

Signed-off-by: Tony Lindgren <tony@atomide.com>
---
 arch/arm/mach-omap2/omap_hwmod_44xx_data.c | 98 ----------------------
 1 file changed, 98 deletions(-)

diff --git a/arch/arm/mach-omap2/omap_hwmod_44xx_data.c b/arch/arm/mach-omap2/omap_hwmod_44xx_data.c
--- a/arch/arm/mach-omap2/omap_hwmod_44xx_data.c
+++ b/arch/arm/mach-omap2/omap_hwmod_44xx_data.c
@@ -92,27 +92,6 @@ static struct omap_hwmod omap44xx_l3_main_3_hwmod = {
 	},
 };
 
-/*
- * 'l4' class
- * instance(s): l4_abe, l4_cfg
- */
-static struct omap_hwmod_class omap44xx_l4_hwmod_class = {
-	.name	= "l4",
-};
-
-/* l4_cfg */
-static struct omap_hwmod omap44xx_l4_cfg_hwmod = {
-	.name		= "l4_cfg",
-	.class		= &omap44xx_l4_hwmod_class,
-	.clkdm_name	= "l4_cfg_clkdm",
-	.prcm = {
-		.omap4 = {
-			.clkctrl_offs = OMAP4_CM_L4CFG_L4_CFG_CLKCTRL_OFFSET,
-			.context_offs = OMAP4_RM_L4CFG_L4_CFG_CONTEXT_OFFSET,
-		},
-	},
-};
-
 /*
  * 'ocp_wp_noc' class
  * instance(s): ocp_wp_noc
@@ -168,29 +147,6 @@ static struct omap_hwmod omap44xx_ocmc_ram_hwmod = {
 	},
 };
 
-
-/*
- * 'prcm' class
- * power and reset manager (part of the prcm infrastructure) + clock manager 2
- * + clock manager 1 (in always on power domain) + local prm in mpu
- */
-
-static struct omap_hwmod_class omap44xx_prcm_hwmod_class = {
-	.name	= "prcm",
-};
-
-/* cm_core */
-static struct omap_hwmod omap44xx_cm_core_hwmod = {
-	.name		= "cm_core",
-	.class		= &omap44xx_prcm_hwmod_class,
-	.flags		= HWMOD_NO_IDLEST,
-	.prcm = {
-		.omap4 = {
-			.flags = HWMOD_OMAP4_NO_CONTEXT_LOSS_BIT,
-		},
-	},
-};
-
 /*
  * 'sl2if' class
  * shared level 2 memory interface
@@ -242,14 +198,6 @@ static struct omap_hwmod_ocp_if omap44xx_l3_main_2__l3_main_1 = {
 	.user		= OCP_USER_MPU | OCP_USER_SDMA,
 };
 
-/* l4_cfg -> l3_main_1 */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__l3_main_1 = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_l3_main_1_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
 /* l3_main_1 -> l3_main_2 */
 static struct omap_hwmod_ocp_if omap44xx_l3_main_1__l3_main_2 = {
 	.master		= &omap44xx_l3_main_1_hwmod,
@@ -258,14 +206,6 @@ static struct omap_hwmod_ocp_if omap44xx_l3_main_1__l3_main_2 = {
 	.user		= OCP_USER_MPU,
 };
 
-/* l4_cfg -> l3_main_2 */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__l3_main_2 = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_l3_main_2_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
 /* l3_main_1 -> l3_main_3 */
 static struct omap_hwmod_ocp_if omap44xx_l3_main_1__l3_main_3 = {
 	.master		= &omap44xx_l3_main_1_hwmod,
@@ -282,30 +222,6 @@ static struct omap_hwmod_ocp_if omap44xx_l3_main_2__l3_main_3 = {
 	.user		= OCP_USER_MPU | OCP_USER_SDMA,
 };
 
-/* l4_cfg -> l3_main_3 */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__l3_main_3 = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_l3_main_3_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
-/* l3_main_1 -> l4_cfg */
-static struct omap_hwmod_ocp_if omap44xx_l3_main_1__l4_cfg = {
-	.master		= &omap44xx_l3_main_1_hwmod,
-	.slave		= &omap44xx_l4_cfg_hwmod,
-	.clk		= "l3_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
-/* l4_cfg -> ocp_wp_noc */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__ocp_wp_noc = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_ocp_wp_noc_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
 /* l3_main_2 -> ocmc_ram */
 static struct omap_hwmod_ocp_if omap44xx_l3_main_2__ocmc_ram = {
 	.master		= &omap44xx_l3_main_2_hwmod,
@@ -314,14 +230,6 @@ static struct omap_hwmod_ocp_if omap44xx_l3_main_2__ocmc_ram = {
 	.user		= OCP_USER_MPU | OCP_USER_SDMA,
 };
 
-/* l4_cfg -> cm_core */
-static struct omap_hwmod_ocp_if omap44xx_l4_cfg__cm_core = {
-	.master		= &omap44xx_l4_cfg_hwmod,
-	.slave		= &omap44xx_cm_core_hwmod,
-	.clk		= "l4_div_ck",
-	.user		= OCP_USER_MPU | OCP_USER_SDMA,
-};
-
 /* l3_main_2 -> sl2if */
 static struct omap_hwmod_ocp_if __maybe_unused omap44xx_l3_main_2__sl2if = {
 	.master		= &omap44xx_l3_main_2_hwmod,
@@ -334,16 +242,10 @@ static struct omap_hwmod_ocp_if *omap44xx_hwmod_ocp_ifs[] __initdata = {
 	&omap44xx_l3_main_3__l3_instr,
 	&omap44xx_ocp_wp_noc__l3_instr,
 	&omap44xx_l3_main_2__l3_main_1,
-	&omap44xx_l4_cfg__l3_main_1,
 	&omap44xx_l3_main_1__l3_main_2,
-	&omap44xx_l4_cfg__l3_main_2,
 	&omap44xx_l3_main_1__l3_main_3,
 	&omap44xx_l3_main_2__l3_main_3,
-	&omap44xx_l4_cfg__l3_main_3,
-	&omap44xx_l3_main_1__l4_cfg,
-	&omap44xx_l4_cfg__ocp_wp_noc,
 	&omap44xx_l3_main_2__ocmc_ram,
-	&omap44xx_l4_cfg__cm_core,
 	/* &omap44xx_l3_main_2__sl2if, */
 	NULL,
 };
-- 
2.30.1

_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel

  parent reply	other threads:[~2021-03-08 13:47 UTC|newest]

Thread overview: 24+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-03-08 13:46 [PATCH 00/11] Drop legacy data for omap4 Tony Lindgren
2021-03-08 13:46 ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 01/11] ARM: OMAP2+: Drop legacy platform data for omap4 iss Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 02/11] ARM: OMAP2+: Drop legacy platform data for omap4 control modules Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 03/11] ARM: OMAP2+: Drop legacy platform data for omap4 dmm Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 04/11] ARM: OMAP2+: Drop legacy platform data for omap4 emif Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 05/11] ARM: OMAP2+: Drop legacy platform data for omap4 debugss Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 06/11] ARM: OMAP2+: Drop legacy platform data for omap4 mpu Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 07/11] ARM: OMAP2+: Drop legacy platform data for omap4 l4_wkup Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 08/11] ARM: OMAP2+: Drop legacy platform data for omap4 l4_per Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` Tony Lindgren [this message]
2021-03-08 13:46   ` [PATCH 09/11] ARM: OMAP2+: Drop legacy platform data for omap4 l4_cfg Tony Lindgren
2021-03-08 13:46 ` [PATCH 10/11] ARM: OMAP2+: Drop legacy platform data for omap4 l3 Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren
2021-03-08 13:46 ` [PATCH 11/11] ARM: OMAP2+: Drop legacy platform data for omap4 hwmod Tony Lindgren
2021-03-08 13:46   ` Tony Lindgren

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20210308134627.13056-10-tony@atomide.com \
    --to=tony@atomide.com \
    --cc=linux-arm-kernel@lists.infradead.org \
    --cc=linux-omap@vger.kernel.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.