linux-kernel.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
* [PATCH v4] thermal: qoriq: Update the settings for TMUv2
@ 2020-05-26  6:02 Yuantian Tang
  2020-05-26 12:32 ` Daniel Lezcano
  0 siblings, 1 reply; 2+ messages in thread
From: Yuantian Tang @ 2020-05-26  6:02 UTC (permalink / raw)
  To: daniel.lezcano, rui.zhang, edubezval
  Cc: linux-pm, linux-kernel, Yuantian Tang

For TMU v2, TMSAR registers need to be set properly to get the
accurate temperature values.
Also the temperature read needs to be converted to degree Celsius
since it is in degrees Kelvin.

Signed-off-by: Yuantian Tang <andy.tang@nxp.com>
---
v4:
	- replace the hard-coded number with constant variables
	- update some comments as needed

 drivers/thermal/qoriq_thermal.c | 26 ++++++++++++++++++++++++--
 1 file changed, 24 insertions(+), 2 deletions(-)

diff --git a/drivers/thermal/qoriq_thermal.c b/drivers/thermal/qoriq_thermal.c
index 028a6bbf75dc..73049f9bea25 100644
--- a/drivers/thermal/qoriq_thermal.c
+++ b/drivers/thermal/qoriq_thermal.c
@@ -11,6 +11,7 @@
 #include <linux/regmap.h>
 #include <linux/sizes.h>
 #include <linux/thermal.h>
+#include <linux/units.h>
 
 #include "thermal_core.h"
 #include "thermal_hwmon.h"
@@ -23,6 +24,7 @@
 #define TMTMIR_DEFAULT	0x0000000f
 #define TIER_DISABLE	0x0
 #define TEUMR0_V2		0x51009c00
+#define TMSARA_V2		0xe
 #define TMU_VER1		0x1
 #define TMU_VER2		0x2
 
@@ -50,6 +52,9 @@
 					    * Site Register
 					    */
 #define TRITSR_V	BIT(31)
+#define REGS_V2_TMSAR(n)	(0x304 + 16 * (n))	/* TMU monitoring
+						* site adjustment register
+						*/
 #define REGS_TTRnCR(n)	(0xf10 + 4 * (n)) /* Temperature Range n
 					   * Control Register
 					   */
@@ -85,12 +90,21 @@ static int tmu_get_temp(void *p, int *temp)
 	/*
 	 * REGS_TRITSR(id) has the following layout:
 	 *
+	 * For TMU Rev1:
 	 * 31  ... 7 6 5 4 3 2 1 0
 	 *  V          TEMP
 	 *
 	 * Where V bit signifies if the measurement is ready and is
 	 * within sensor range. TEMP is an 8 bit value representing
-	 * temperature in C.
+	 * temperature in Celsius.
+
+	 * For TMU Rev2:
+	 * 31  ... 8 7 6 5 4 3 2 1 0
+	 *  V          TEMP
+	 *
+	 * Where V bit signifies if the measurement is ready and is
+	 * within sensor range. TEMP is an 9 bit value representing
+	 * temperature in KelVin.
 	 */
 	if (regmap_read_poll_timeout(qdata->regmap,
 				     REGS_TRITSR(qsensor->id),
@@ -100,7 +114,10 @@ static int tmu_get_temp(void *p, int *temp)
 				     10 * USEC_PER_MSEC))
 		return -ENODATA;
 
-	*temp = (val & 0xff) * 1000;
+	if (qdata->ver == TMU_VER1)
+		*temp = (val & GENMASK(7, 0)) * MILLIDEGREE_PER_DEGREE;
+	else
+		*temp = kelvin_to_millicelsius(val & GENMASK(8, 0));
 
 	return 0;
 }
@@ -192,6 +209,8 @@ static int qoriq_tmu_calibration(struct device *dev,
 
 static void qoriq_tmu_init_device(struct qoriq_tmu_data *data)
 {
+	int i;
+
 	/* Disable interrupt, using polling instead */
 	regmap_write(data->regmap, REGS_TIER, TIER_DISABLE);
 
@@ -202,6 +221,8 @@ static void qoriq_tmu_init_device(struct qoriq_tmu_data *data)
 	} else {
 		regmap_write(data->regmap, REGS_V2_TMTMIR, TMTMIR_DEFAULT);
 		regmap_write(data->regmap, REGS_V2_TEUMR(0), TEUMR0_V2);
+		for (i = 0; i < SITES_MAX; i++)
+			regmap_write(data->regmap, REGS_V2_TMSAR(i), TMSARA_V2);
 	}
 
 	/* Disable monitoring */
@@ -212,6 +233,7 @@ static const struct regmap_range qoriq_yes_ranges[] = {
 	regmap_reg_range(REGS_TMR, REGS_TSCFGR),
 	regmap_reg_range(REGS_TTRnCR(0), REGS_TTRnCR(3)),
 	regmap_reg_range(REGS_V2_TEUMR(0), REGS_V2_TEUMR(2)),
+	regmap_reg_range(REGS_V2_TMSAR(0), REGS_V2_TMSAR(15)),
 	regmap_reg_range(REGS_IPBRR(0), REGS_IPBRR(1)),
 	/* Read only registers below */
 	regmap_reg_range(REGS_TRITSR(0), REGS_TRITSR(15)),
-- 
2.17.1


^ permalink raw reply related	[flat|nested] 2+ messages in thread

* Re: [PATCH v4] thermal: qoriq: Update the settings for TMUv2
  2020-05-26  6:02 [PATCH v4] thermal: qoriq: Update the settings for TMUv2 Yuantian Tang
@ 2020-05-26 12:32 ` Daniel Lezcano
  0 siblings, 0 replies; 2+ messages in thread
From: Daniel Lezcano @ 2020-05-26 12:32 UTC (permalink / raw)
  To: Yuantian Tang, rui.zhang, edubezval; +Cc: linux-pm, linux-kernel

On 26/05/2020 08:02, Yuantian Tang wrote:
> For TMU v2, TMSAR registers need to be set properly to get the
> accurate temperature values.
> Also the temperature read needs to be converted to degree Celsius
> since it is in degrees Kelvin.
> 
> Signed-off-by: Yuantian Tang <andy.tang@nxp.com>

Applied, thanks!




-- 
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog

^ permalink raw reply	[flat|nested] 2+ messages in thread

end of thread, other threads:[~2020-05-26 12:32 UTC | newest]

Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2020-05-26  6:02 [PATCH v4] thermal: qoriq: Update the settings for TMUv2 Yuantian Tang
2020-05-26 12:32 ` Daniel Lezcano

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).