From: "Niklas Söderlund" <niklas.soderlund@ragnatech.se> To: Geert Uytterhoeven <geert+renesas@glider.be> Cc: Magnus Damm <magnus.damm@gmail.com>, linux-renesas-soc@vger.kernel.org, linux-arm-kernel@lists.infradead.org Subject: Re: [PATCH] arm64: dts: renesas: r8a779g0: Add thermal nodes Date: Thu, 9 Feb 2023 22:37:36 +0100 [thread overview] Message-ID: <Y+VnoFzPx5/9XpV1@oden.dyn.berto.se> (raw) In-Reply-To: <b92a1a28afb9f75f24f0137af9f77e95d7ebaec3.1675959327.git.geert+renesas@glider.be> Hello Geert, Thanks for your work. On 2023-02-09 17:23:30 +0100, Geert Uytterhoeven wrote: > Add device nodes for the Thermal Sensor/Chip Internal Voltage > Monitor/Core Voltage Monitor (THS/CIVM/CVM) and the various thermal > zones on the Renesas R-Car V4H (R8A779G0) SoC. > > Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Reviewed-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> > --- > To be queued in renesas-devel for v6.4. > > For testing, this patch and its dependencies can be found at > https://git.kernel.org/pub/scm/linux/kernel/git/geert/renesas-drivers.git/log/?h=topic/r8a779g0-thermal-v1 > > arch/arm64/boot/dts/renesas/r8a779g0.dtsi | 70 +++++++++++++++++++++++ > 1 file changed, 70 insertions(+) > > diff --git a/arch/arm64/boot/dts/renesas/r8a779g0.dtsi b/arch/arm64/boot/dts/renesas/r8a779g0.dtsi > index 70eaf79569258357..6d5ccc6f02a1173c 100644 > --- a/arch/arm64/boot/dts/renesas/r8a779g0.dtsi > +++ b/arch/arm64/boot/dts/renesas/r8a779g0.dtsi > @@ -438,6 +438,18 @@ sysc: system-controller@e6180000 { > #power-domain-cells = <1>; > }; > > + tsc: thermal@e6198000 { > + compatible = "renesas,r8a779g0-thermal"; > + reg = <0 0xe6198000 0 0x200>, > + <0 0xe61a0000 0 0x200>, > + <0 0xe61a8000 0 0x200>, > + <0 0xe61b0000 0 0x200>; > + clocks = <&cpg CPG_MOD 919>; > + power-domains = <&sysc R8A779G0_PD_ALWAYS_ON>; > + resets = <&cpg 919>; > + #thermal-sensor-cells = <1>; > + }; > + > intc_ex: interrupt-controller@e61c0000 { > compatible = "renesas,intc-ex-r8a779g0", "renesas,irqc"; > #interrupt-cells = <2>; > @@ -1402,6 +1414,64 @@ prr: chipid@fff00044 { > }; > }; > > + thermal-zones { > + sensor_thermal_cr52: sensor1-thermal { > + polling-delay-passive = <250>; > + polling-delay = <1000>; > + thermal-sensors = <&tsc 0>; > + > + trips { > + sensor1_crit: sensor1-crit { > + temperature = <120000>; > + hysteresis = <1000>; > + type = "critical"; > + }; > + }; > + }; > + > + sensor_thermal_cnn: sensor2-thermal { > + polling-delay-passive = <250>; > + polling-delay = <1000>; > + thermal-sensors = <&tsc 1>; > + > + trips { > + sensor2_crit: sensor2-crit { > + temperature = <120000>; > + hysteresis = <1000>; > + type = "critical"; > + }; > + }; > + }; > + > + sensor_thermal_ca76: sensor3-thermal { > + polling-delay-passive = <250>; > + polling-delay = <1000>; > + thermal-sensors = <&tsc 2>; > + > + trips { > + sensor3_crit: sensor3-crit { > + temperature = <120000>; > + hysteresis = <1000>; > + type = "critical"; > + }; > + }; > + }; > + > + sensor_thermal_ddr1: sensor4-thermal { > + polling-delay-passive = <250>; > + polling-delay = <1000>; > + thermal-sensors = <&tsc 3>; > + > + trips { > + sensor4_crit: sensor4-crit { > + temperature = <120000>; > + hysteresis = <1000>; > + type = "critical"; > + }; > + }; > + }; > + }; > + > timer { > compatible = "arm,armv8-timer"; > interrupts-extended = <&gic GIC_PPI 13 (GIC_CPU_MASK_SIMPLE(4) | IRQ_TYPE_LEVEL_LOW)>, > -- > 2.34.1 > -- Kind Regards, Niklas Söderlund
WARNING: multiple messages have this Message-ID (diff)
From: "Niklas Söderlund" <niklas.soderlund@ragnatech.se> To: Geert Uytterhoeven <geert+renesas@glider.be> Cc: Magnus Damm <magnus.damm@gmail.com>, linux-renesas-soc@vger.kernel.org, linux-arm-kernel@lists.infradead.org Subject: Re: [PATCH] arm64: dts: renesas: r8a779g0: Add thermal nodes Date: Thu, 9 Feb 2023 22:37:36 +0100 [thread overview] Message-ID: <Y+VnoFzPx5/9XpV1@oden.dyn.berto.se> (raw) In-Reply-To: <b92a1a28afb9f75f24f0137af9f77e95d7ebaec3.1675959327.git.geert+renesas@glider.be> Hello Geert, Thanks for your work. On 2023-02-09 17:23:30 +0100, Geert Uytterhoeven wrote: > Add device nodes for the Thermal Sensor/Chip Internal Voltage > Monitor/Core Voltage Monitor (THS/CIVM/CVM) and the various thermal > zones on the Renesas R-Car V4H (R8A779G0) SoC. > > Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Reviewed-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> > --- > To be queued in renesas-devel for v6.4. > > For testing, this patch and its dependencies can be found at > https://git.kernel.org/pub/scm/linux/kernel/git/geert/renesas-drivers.git/log/?h=topic/r8a779g0-thermal-v1 > > arch/arm64/boot/dts/renesas/r8a779g0.dtsi | 70 +++++++++++++++++++++++ > 1 file changed, 70 insertions(+) > > diff --git a/arch/arm64/boot/dts/renesas/r8a779g0.dtsi b/arch/arm64/boot/dts/renesas/r8a779g0.dtsi > index 70eaf79569258357..6d5ccc6f02a1173c 100644 > --- a/arch/arm64/boot/dts/renesas/r8a779g0.dtsi > +++ b/arch/arm64/boot/dts/renesas/r8a779g0.dtsi > @@ -438,6 +438,18 @@ sysc: system-controller@e6180000 { > #power-domain-cells = <1>; > }; > > + tsc: thermal@e6198000 { > + compatible = "renesas,r8a779g0-thermal"; > + reg = <0 0xe6198000 0 0x200>, > + <0 0xe61a0000 0 0x200>, > + <0 0xe61a8000 0 0x200>, > + <0 0xe61b0000 0 0x200>; > + clocks = <&cpg CPG_MOD 919>; > + power-domains = <&sysc R8A779G0_PD_ALWAYS_ON>; > + resets = <&cpg 919>; > + #thermal-sensor-cells = <1>; > + }; > + > intc_ex: interrupt-controller@e61c0000 { > compatible = "renesas,intc-ex-r8a779g0", "renesas,irqc"; > #interrupt-cells = <2>; > @@ -1402,6 +1414,64 @@ prr: chipid@fff00044 { > }; > }; > > + thermal-zones { > + sensor_thermal_cr52: sensor1-thermal { > + polling-delay-passive = <250>; > + polling-delay = <1000>; > + thermal-sensors = <&tsc 0>; > + > + trips { > + sensor1_crit: sensor1-crit { > + temperature = <120000>; > + hysteresis = <1000>; > + type = "critical"; > + }; > + }; > + }; > + > + sensor_thermal_cnn: sensor2-thermal { > + polling-delay-passive = <250>; > + polling-delay = <1000>; > + thermal-sensors = <&tsc 1>; > + > + trips { > + sensor2_crit: sensor2-crit { > + temperature = <120000>; > + hysteresis = <1000>; > + type = "critical"; > + }; > + }; > + }; > + > + sensor_thermal_ca76: sensor3-thermal { > + polling-delay-passive = <250>; > + polling-delay = <1000>; > + thermal-sensors = <&tsc 2>; > + > + trips { > + sensor3_crit: sensor3-crit { > + temperature = <120000>; > + hysteresis = <1000>; > + type = "critical"; > + }; > + }; > + }; > + > + sensor_thermal_ddr1: sensor4-thermal { > + polling-delay-passive = <250>; > + polling-delay = <1000>; > + thermal-sensors = <&tsc 3>; > + > + trips { > + sensor4_crit: sensor4-crit { > + temperature = <120000>; > + hysteresis = <1000>; > + type = "critical"; > + }; > + }; > + }; > + }; > + > timer { > compatible = "arm,armv8-timer"; > interrupts-extended = <&gic GIC_PPI 13 (GIC_CPU_MASK_SIMPLE(4) | IRQ_TYPE_LEVEL_LOW)>, > -- > 2.34.1 > -- Kind Regards, Niklas Söderlund _______________________________________________ linux-arm-kernel mailing list linux-arm-kernel@lists.infradead.org http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
next prev parent reply other threads:[~2023-02-09 21:37 UTC|newest] Thread overview: 6+ messages / expand[flat|nested] mbox.gz Atom feed top 2023-02-09 16:23 [PATCH] arm64: dts: renesas: r8a779g0: Add thermal nodes Geert Uytterhoeven 2023-02-09 16:23 ` Geert Uytterhoeven 2023-02-09 16:30 ` Wolfram Sang 2023-02-09 16:30 ` Wolfram Sang 2023-02-09 21:37 ` Niklas Söderlund [this message] 2023-02-09 21:37 ` Niklas Söderlund
Reply instructions: You may reply publicly to this message via plain-text email using any one of the following methods: * Save the following mbox file, import it into your mail client, and reply-to-all from there: mbox Avoid top-posting and favor interleaved quoting: https://en.wikipedia.org/wiki/Posting_style#Interleaved_style * Reply using the --to, --cc, and --in-reply-to switches of git-send-email(1): git send-email \ --in-reply-to=Y+VnoFzPx5/9XpV1@oden.dyn.berto.se \ --to=niklas.soderlund@ragnatech.se \ --cc=geert+renesas@glider.be \ --cc=linux-arm-kernel@lists.infradead.org \ --cc=linux-renesas-soc@vger.kernel.org \ --cc=magnus.damm@gmail.com \ /path/to/YOUR_REPLY https://kernel.org/pub/software/scm/git/docs/git-send-email.html * If your mail client supports setting the In-Reply-To header via mailto: links, try the mailto: linkBe sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes, see mirroring instructions on how to clone and mirror all data and code used by this external index.