All of lore.kernel.org
 help / color / mirror / Atom feed
From: Chanwoo Choi <cw00.choi@samsung.com>
To: "Leonard Crestez" <leonard.crestez@nxp.com>,
	"Artur Świgoń" <a.swigon@partner.samsung.com>,
	"georgi.djakov@linaro.org" <georgi.djakov@linaro.org>,
	"Viresh Kumar" <viresh.kumar@linaro.org>
Cc: "devicetree@vger.kernel.org" <devicetree@vger.kernel.org>,
	"linux-arm-kernel@lists.infradead.org" 
	<linux-arm-kernel@lists.infradead.org>,
	"linux-samsung-soc@vger.kernel.org" 
	<linux-samsung-soc@vger.kernel.org>,
	"linux-kernel@vger.kernel.org" <linux-kernel@vger.kernel.org>,
	"linux-pm@vger.kernel.org" <linux-pm@vger.kernel.org>,
	"dri-devel@lists.freedesktop.org"
	<dri-devel@lists.freedesktop.org>,
	"krzk@kernel.org" <krzk@kernel.org>,
	"myungjoo.ham@samsung.com" <myungjoo.ham@samsung.com>,
	"inki.dae@samsung.com" <inki.dae@samsung.com>,
	"sw0312.kim@samsung.com" <sw0312.kim@samsung.com>,
	"m.szyprowski@samsung.com" <m.szyprowski@samsung.com>,
	"Rafael J. Wysocki" <rafael@kernel.org>,
	Saravana Kannan <saravanak@google.com>,
	Lukasz Luba <l.luba@partner.samsung.com>,
	"cpgs (cpgs@samsung.com)" <cpgs@samsung.com>
Subject: Re: [RFC PATCH 09/11] devfreq: exynos-bus: Add interconnect functionality to exynos-bus
Date: Tue, 20 Aug 2019 08:44:05 +0900	[thread overview]
Message-ID: <08bd637a-2038-9f64-a189-682427ce5bfb@samsung.com> (raw)
In-Reply-To: <VI1PR04MB7023B5095F706635354C4C50EED70@VI1PR04MB7023.eurprd04.prod.outlook.com>

Hi Artur and Leonard,

On 19. 8. 9. 오전 12:00, Leonard Crestez wrote:
> On 29.07.2019 04:49, Chanwoo Choi wrote:
>> On 19. 7. 23. 오후 9:20, Artur Świgoń wrote:
>>> This patch adds interconnect functionality to the exynos-bus devfreq
>>> driver.
>>>
>>> The devfreq target() callback provided by exynos-bus now selects either the
>>> frequency calculated by the devfreq governor or the frequency requested via
>>> the interconnect API for the given node, whichever is higher.
>>
>> Basically, I agree to support the QoS requirement between devices.
>> But, I think that need to consider the multiple cases.
>>
>> 1. When changing the devfreq governor by user,
>> For example of the connection between bus_dmc/leftbus/display on patch8,
>> there are possible multiple cases with various devfreq governor
>> which is changed on the runtime by user through sysfs interface.
>>
>> If users changes the devfreq governor as following:
>> Before,
>> - bus_dmc (simple_ondemand, available frequency 100/200/300/400 MHz)
>> --> bus_leftbus(simple_ondemand, available frequency 100/200/300/400 MHz)
>> ----> bus_display(passive)
>>
>> After changed governor of bus_dmc,
>> if the min_freq by interconnect requirement is 400Mhz,
>> - bus_dmc (powersave) : min_freq and max_freq and cur_freq is 100MHz
>> --> bus_leftbus(simple_ondemand) : cur_freq is 400Mhz
>> ----> bus_display(passive)
>>
>> The final frequency is 400MHz of bus_dmc
>> even if the min_freq/max_freq/cur_freq is 100MHz.
>> It cannot show the correct min_freq/max_freq through
>> devfreq sysfs interface.
>>
>>
>> 2. When disabling the some frequency by devfreq-thermal throttling,
>> This patch checks the min_freq of interconnect requirement
>> in the exynos_bus_target() and exynos_bus_passive_target().
>> Also, it cannot show the correct min_freq/max_freq through
>> devfreq sysfs interface.
>>
>> For example of bus_dmc bus,
>> - The available frequencies are 100MHz, 200MHz, 300MHz, 400MHz
>> - Disable 400MHz by devfreq-thermal throttling
>> - min_freq is 100MHz
>> - max_freq is 300MHz
>> - min_freq of interconnect is 400MHz
>>
>> In result, the final frequency is 400MHz by exynos_bus_target()
>> There are no problem for working. But, the user cannot know
>> reason why cur_freq is 400MHz even if max_freq is 300MHz.
>>
>> Basically, update_devfreq() considers the all constraints
>> of min_freq/max_freq to decide the proper target frequency.
> 
> I think that applying the interconnect min_freq via dev_pm_qos can help 
> with many of these concerns: update_devfreq controls all the min/max 
> handling, sysfs is accurate and better decisions can be made regarding 
> thermal. Enforcing constraints in the core is definitely better.
> 
> This wouldn't even be a very big change, you don't need to actually move 
> the interconnect code outside of devfreq. Just make every devfreq/icc 
> node register a dev_pm_qos_request for itself during registration and 
> call dev_pm_qos_update_request inside exynos_bus_icc_set.
> 
> See: https://patchwork.kernel.org/patch/11084279/

I agree this approach of Leonard. If we use the dev_pm_qos[1] feature,
it resolve the issue of my comment1/2.

In summary, when receive the minimum frequency requirement
from interconnect path, the each bus uses the dev_pm_qos interface
in order to inform the minimum frequency from interconnect to devfreq.
And then the devfreq core will execute the update_devfreq()
with all frequency requirements as following:
- the user input (min/max frequency though devfreq sysfs
- the target frequency provided by devfreq governor
- the minimum frequency from interconnect path

-- 
Best Regards,
Chanwoo Choi
Samsung Electronics

WARNING: multiple messages have this Message-ID (diff)
From: Chanwoo Choi <cw00.choi@samsung.com>
To: "Leonard Crestez" <leonard.crestez@nxp.com>,
	"Artur Świgoń" <a.swigon@partner.samsung.com>,
	"georgi.djakov@linaro.org" <georgi.djakov@linaro.org>,
	"Viresh Kumar" <viresh.kumar@linaro.org>
Cc: "devicetree@vger.kernel.org" <devicetree@vger.kernel.org>,
	"linux-arm-kernel@lists.infradead.org"
	<linux-arm-kernel@lists.infradead.org>,
	"linux-samsung-soc@vger.kernel.org"
	<linux-samsung-soc@vger.kernel.org>,
	"linux-kernel@vger.kernel.org" <linux-kernel@vger.kernel.org>,
	"linux-pm@vger.kernel.org" <linux-pm@vger.kernel.org>,
	"dri-devel@lists.freedesktop.org"
	<dri-devel@lists.freedesktop.org>,
	"krzk@kernel.org" <krzk@kernel.org>,
	"myungjoo.ham@samsung.com" <myungjoo.ham@samsung.com>,
	"inki.dae@samsung.com" <inki.dae@samsung.com>,
	"sw0312.kim@samsung.com" <sw0312.kim@samsung.com>,
	"m.szyprowski@samsung.com" <m.szyprowski@samsung.com>,
	"Rafael J. Wysocki" <rafael@kernel.org>,
	Saravana Kannan <saravanak@google.com>,
	Lukasz Luba <l.luba@partner.samsung.com>
Subject: Re: [RFC PATCH 09/11] devfreq: exynos-bus: Add interconnect functionality to exynos-bus
Date: Tue, 20 Aug 2019 08:44:05 +0900	[thread overview]
Message-ID: <08bd637a-2038-9f64-a189-682427ce5bfb@samsung.com> (raw)
In-Reply-To: <VI1PR04MB7023B5095F706635354C4C50EED70@VI1PR04MB7023.eurprd04.prod.outlook.com>

Hi Artur and Leonard,

On 19. 8. 9. 오전 12:00, Leonard Crestez wrote:
> On 29.07.2019 04:49, Chanwoo Choi wrote:
>> On 19. 7. 23. 오후 9:20, Artur Świgoń wrote:
>>> This patch adds interconnect functionality to the exynos-bus devfreq
>>> driver.
>>>
>>> The devfreq target() callback provided by exynos-bus now selects either the
>>> frequency calculated by the devfreq governor or the frequency requested via
>>> the interconnect API for the given node, whichever is higher.
>>
>> Basically, I agree to support the QoS requirement between devices.
>> But, I think that need to consider the multiple cases.
>>
>> 1. When changing the devfreq governor by user,
>> For example of the connection between bus_dmc/leftbus/display on patch8,
>> there are possible multiple cases with various devfreq governor
>> which is changed on the runtime by user through sysfs interface.
>>
>> If users changes the devfreq governor as following:
>> Before,
>> - bus_dmc (simple_ondemand, available frequency 100/200/300/400 MHz)
>> --> bus_leftbus(simple_ondemand, available frequency 100/200/300/400 MHz)
>> ----> bus_display(passive)
>>
>> After changed governor of bus_dmc,
>> if the min_freq by interconnect requirement is 400Mhz,
>> - bus_dmc (powersave) : min_freq and max_freq and cur_freq is 100MHz
>> --> bus_leftbus(simple_ondemand) : cur_freq is 400Mhz
>> ----> bus_display(passive)
>>
>> The final frequency is 400MHz of bus_dmc
>> even if the min_freq/max_freq/cur_freq is 100MHz.
>> It cannot show the correct min_freq/max_freq through
>> devfreq sysfs interface.
>>
>>
>> 2. When disabling the some frequency by devfreq-thermal throttling,
>> This patch checks the min_freq of interconnect requirement
>> in the exynos_bus_target() and exynos_bus_passive_target().
>> Also, it cannot show the correct min_freq/max_freq through
>> devfreq sysfs interface.
>>
>> For example of bus_dmc bus,
>> - The available frequencies are 100MHz, 200MHz, 300MHz, 400MHz
>> - Disable 400MHz by devfreq-thermal throttling
>> - min_freq is 100MHz
>> - max_freq is 300MHz
>> - min_freq of interconnect is 400MHz
>>
>> In result, the final frequency is 400MHz by exynos_bus_target()
>> There are no problem for working. But, the user cannot know
>> reason why cur_freq is 400MHz even if max_freq is 300MHz.
>>
>> Basically, update_devfreq() considers the all constraints
>> of min_freq/max_freq to decide the proper target frequency.
> 
> I think that applying the interconnect min_freq via dev_pm_qos can help 
> with many of these concerns: update_devfreq controls all the min/max 
> handling, sysfs is accurate and better decisions can be made regarding 
> thermal. Enforcing constraints in the core is definitely better.
> 
> This wouldn't even be a very big change, you don't need to actually move 
> the interconnect code outside of devfreq. Just make every devfreq/icc 
> node register a dev_pm_qos_request for itself during registration and 
> call dev_pm_qos_update_request inside exynos_bus_icc_set.
> 
> See: https://patchwork.kernel.org/patch/11084279/

I agree this approach of Leonard. If we use the dev_pm_qos[1] feature,
it resolve the issue of my comment1/2.

In summary, when receive the minimum frequency requirement
from interconnect path, the each bus uses the dev_pm_qos interface
in order to inform the minimum frequency from interconnect to devfreq.
And then the devfreq core will execute the update_devfreq()
with all frequency requirements as following:
- the user input (min/max frequency though devfreq sysfs
- the target frequency provided by devfreq governor
- the minimum frequency from interconnect path

-- 
Best Regards,
Chanwoo Choi
Samsung Electronics

WARNING: multiple messages have this Message-ID (diff)
From: Chanwoo Choi <cw00.choi@samsung.com>
To: "Leonard Crestez" <leonard.crestez@nxp.com>,
	"Artur Świgoń" <a.swigon@partner.samsung.com>,
	"georgi.djakov@linaro.org" <georgi.djakov@linaro.org>,
	"Viresh Kumar" <viresh.kumar@linaro.org>
Cc: "devicetree@vger.kernel.org" <devicetree@vger.kernel.org>,
	"linux-samsung-soc@vger.kernel.org"
	<linux-samsung-soc@vger.kernel.org>,
	Saravana Kannan <saravanak@google.com>,
	"linux-pm@vger.kernel.org" <linux-pm@vger.kernel.org>,
	"Rafael J. Wysocki" <rafael@kernel.org>,
	"sw0312.kim@samsung.com" <sw0312.kim@samsung.com>,
	"linux-kernel@vger.kernel.org" <linux-kernel@vger.kernel.org>,
	"dri-devel@lists.freedesktop.org"
	<dri-devel@lists.freedesktop.org>,
	Lukasz Luba <l.luba@partner.samsung.com>,
	"inki.dae@samsung.com" <inki.dae@samsung.com>,
	"myungjoo.ham@samsung.com" <myungjoo.ham@samsung.com>,
	"krzk@kernel.org" <krzk@kernel.org>,
	"cpgs \(cpgs@samsung.com\)" <cpgs@samsung.com>,
	"linux-arm-kernel@lists.infradead.org"
	<linux-arm-kernel@lists.infradead.org>,
	"m.szyprowski@samsung.com" <m.szyprowski@samsung.com>
Subject: Re: [RFC PATCH 09/11] devfreq: exynos-bus: Add interconnect functionality to exynos-bus
Date: Tue, 20 Aug 2019 08:44:05 +0900	[thread overview]
Message-ID: <08bd637a-2038-9f64-a189-682427ce5bfb@samsung.com> (raw)
In-Reply-To: <VI1PR04MB7023B5095F706635354C4C50EED70@VI1PR04MB7023.eurprd04.prod.outlook.com>

Hi Artur and Leonard,

On 19. 8. 9. 오전 12:00, Leonard Crestez wrote:
> On 29.07.2019 04:49, Chanwoo Choi wrote:
>> On 19. 7. 23. 오후 9:20, Artur Świgoń wrote:
>>> This patch adds interconnect functionality to the exynos-bus devfreq
>>> driver.
>>>
>>> The devfreq target() callback provided by exynos-bus now selects either the
>>> frequency calculated by the devfreq governor or the frequency requested via
>>> the interconnect API for the given node, whichever is higher.
>>
>> Basically, I agree to support the QoS requirement between devices.
>> But, I think that need to consider the multiple cases.
>>
>> 1. When changing the devfreq governor by user,
>> For example of the connection between bus_dmc/leftbus/display on patch8,
>> there are possible multiple cases with various devfreq governor
>> which is changed on the runtime by user through sysfs interface.
>>
>> If users changes the devfreq governor as following:
>> Before,
>> - bus_dmc (simple_ondemand, available frequency 100/200/300/400 MHz)
>> --> bus_leftbus(simple_ondemand, available frequency 100/200/300/400 MHz)
>> ----> bus_display(passive)
>>
>> After changed governor of bus_dmc,
>> if the min_freq by interconnect requirement is 400Mhz,
>> - bus_dmc (powersave) : min_freq and max_freq and cur_freq is 100MHz
>> --> bus_leftbus(simple_ondemand) : cur_freq is 400Mhz
>> ----> bus_display(passive)
>>
>> The final frequency is 400MHz of bus_dmc
>> even if the min_freq/max_freq/cur_freq is 100MHz.
>> It cannot show the correct min_freq/max_freq through
>> devfreq sysfs interface.
>>
>>
>> 2. When disabling the some frequency by devfreq-thermal throttling,
>> This patch checks the min_freq of interconnect requirement
>> in the exynos_bus_target() and exynos_bus_passive_target().
>> Also, it cannot show the correct min_freq/max_freq through
>> devfreq sysfs interface.
>>
>> For example of bus_dmc bus,
>> - The available frequencies are 100MHz, 200MHz, 300MHz, 400MHz
>> - Disable 400MHz by devfreq-thermal throttling
>> - min_freq is 100MHz
>> - max_freq is 300MHz
>> - min_freq of interconnect is 400MHz
>>
>> In result, the final frequency is 400MHz by exynos_bus_target()
>> There are no problem for working. But, the user cannot know
>> reason why cur_freq is 400MHz even if max_freq is 300MHz.
>>
>> Basically, update_devfreq() considers the all constraints
>> of min_freq/max_freq to decide the proper target frequency.
> 
> I think that applying the interconnect min_freq via dev_pm_qos can help 
> with many of these concerns: update_devfreq controls all the min/max 
> handling, sysfs is accurate and better decisions can be made regarding 
> thermal. Enforcing constraints in the core is definitely better.
> 
> This wouldn't even be a very big change, you don't need to actually move 
> the interconnect code outside of devfreq. Just make every devfreq/icc 
> node register a dev_pm_qos_request for itself during registration and 
> call dev_pm_qos_update_request inside exynos_bus_icc_set.
> 
> See: https://patchwork.kernel.org/patch/11084279/

I agree this approach of Leonard. If we use the dev_pm_qos[1] feature,
it resolve the issue of my comment1/2.

In summary, when receive the minimum frequency requirement
from interconnect path, the each bus uses the dev_pm_qos interface
in order to inform the minimum frequency from interconnect to devfreq.
And then the devfreq core will execute the update_devfreq()
with all frequency requirements as following:
- the user input (min/max frequency though devfreq sysfs
- the target frequency provided by devfreq governor
- the minimum frequency from interconnect path

-- 
Best Regards,
Chanwoo Choi
Samsung Electronics

_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel

  reply	other threads:[~2019-08-19 23:40 UTC|newest]

Thread overview: 111+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
     [not found] <CGME20190723122022eucas1p2f568f74f981f9de9012eb693c3b446d5@eucas1p2.samsung.com>
2019-07-23 12:20 ` [RFC PATCH 00/11] Simple QoS for exynos-bus driver using interconnect Artur Świgoń
2019-07-23 12:20   ` Artur Świgoń
     [not found]   ` <CGME20190723122022eucas1p1266d90873d564894bd852c20140f8474@eucas1p1.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 01/11] devfreq: exynos-bus: Extract exynos_bus_profile_init() Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 19:07       ` Krzysztof Kozlowski
2019-07-24 19:07         ` Krzysztof Kozlowski
2019-07-31 13:00         ` Artur Świgoń
2019-07-31 13:00           ` Artur Świgoń
2019-08-05  9:56           ` Krzysztof Kozlowski
2019-08-05  9:56             ` Krzysztof Kozlowski
2019-07-25 12:43       ` Chanwoo Choi
2019-07-25 12:43         ` Chanwoo Choi
2019-07-26 10:42         ` Krzysztof Kozlowski
2019-07-26 10:42           ` Krzysztof Kozlowski
2019-07-26 10:42           ` Krzysztof Kozlowski
2019-07-26 10:52           ` Chanwoo Choi
2019-07-26 10:52             ` Chanwoo Choi
     [not found]   ` <CGME20190723122023eucas1p2ff56c00b60a676ed85d9fe159a1839f2@eucas1p2.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 02/11] devfreq: exynos-bus: Extract exynos_bus_profile_init_passive() Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 19:08       ` Krzysztof Kozlowski
2019-07-24 19:08         ` Krzysztof Kozlowski
2019-07-24 19:08         ` Krzysztof Kozlowski
2019-07-25 12:45       ` Chanwoo Choi
2019-07-25 12:45         ` Chanwoo Choi
     [not found]   ` <CGME20190723122024eucas1p1ff060d072132bfbc8a8a1d10fa1f90f8@eucas1p1.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 03/11] devfreq: exynos-bus: Change goto-based logic to if-else logic Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 19:10       ` Krzysztof Kozlowski
2019-07-24 19:10         ` Krzysztof Kozlowski
2019-07-25 12:56       ` Chanwoo Choi
2019-07-25 12:56         ` Chanwoo Choi
2019-07-25 13:02         ` Chanwoo Choi
2019-07-25 13:02           ` Chanwoo Choi
     [not found]   ` <CGME20190723122024eucas1p25a480ccddaa69ee1d0f1a07960ca3f22@eucas1p2.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 04/11] devfreq: exynos-bus: Clean up code Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 19:14       ` Krzysztof Kozlowski
2019-07-24 19:14         ` Krzysztof Kozlowski
2019-07-25 12:50       ` Chanwoo Choi
2019-07-25 12:50         ` Chanwoo Choi
2019-07-26 10:45         ` Krzysztof Kozlowski
2019-07-26 10:45           ` Krzysztof Kozlowski
2019-07-26 11:04           ` Chanwoo Choi
2019-07-26 11:04             ` Chanwoo Choi
     [not found]   ` <CGME20190723122025eucas1p251df372451e0b27ad7f2e3c89df60b64@eucas1p2.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 05/11] icc: Export of_icc_get_from_provider() Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 19:15       ` Krzysztof Kozlowski
2019-07-24 19:15         ` Krzysztof Kozlowski
2019-07-24 19:15         ` Krzysztof Kozlowski
     [not found]   ` <CGME20190723122026eucas1p2acf705de2a47ba54f383d916f5383144@eucas1p2.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 06/11] icc: Relax requirement in of_icc_get_from_provider() Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 19:16       ` Krzysztof Kozlowski
2019-07-24 19:16         ` Krzysztof Kozlowski
     [not found]   ` <CGME20190723122027eucas1p124f44370a63b16dcb765585761d661a3@eucas1p1.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 07/11] icc: Relax condition in apply_constraints() Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
     [not found]   ` <CGME20190723122027eucas1p24b1d76e3139f7cc52614d7613ff9ba98@eucas1p2.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 08/11] arm: dts: exynos: Add parents and #interconnect-cells to Exynos4412 Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 19:24       ` Krzysztof Kozlowski
2019-07-24 19:24         ` Krzysztof Kozlowski
2019-07-24 19:24         ` Krzysztof Kozlowski
2019-07-31 13:00         ` Artur Świgoń
2019-07-31 13:00           ` Artur Świgoń
2019-07-25 13:13       ` Chanwoo Choi
2019-07-25 13:13         ` Chanwoo Choi
2019-07-26 12:02         ` Marek Szyprowski
2019-07-26 12:02           ` Marek Szyprowski
2019-07-29  1:20           ` Chanwoo Choi
2019-07-29  1:20             ` Chanwoo Choi
     [not found]   ` <CGME20190723122028eucas1p2eb75f35b810e71d6c590370aaff0997b@eucas1p2.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 09/11] devfreq: exynos-bus: Add interconnect functionality to exynos-bus Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 18:36       ` Krzysztof Kozlowski
2019-07-24 18:36         ` Krzysztof Kozlowski
2019-07-31 13:01         ` Artur Świgoń
2019-07-31 13:01           ` Artur Świgoń
2019-07-26  8:05       ` Georgi Djakov
2019-07-26  8:05         ` Georgi Djakov
2019-08-01  7:59         ` Artur Świgoń
2019-08-01  7:59           ` Artur Świgoń
2019-08-07 14:21           ` Georgi Djakov
2019-08-07 14:21             ` Georgi Djakov
2019-08-08 13:28             ` Artur Świgoń
2019-08-08 13:28               ` Artur Świgoń
2019-07-29  1:52       ` Chanwoo Choi
2019-07-29  1:52         ` Chanwoo Choi
2019-08-08 13:18         ` Artur Świgoń
2019-08-08 13:18           ` Artur Świgoń
2019-08-09  2:17           ` Chanwoo Choi
2019-08-09  2:17             ` Chanwoo Choi
2019-08-08 15:00         ` Leonard Crestez
2019-08-08 15:00           ` Leonard Crestez
2019-08-08 15:00           ` Leonard Crestez
2019-08-19 23:44           ` Chanwoo Choi [this message]
2019-08-19 23:44             ` Chanwoo Choi
2019-08-19 23:44             ` Chanwoo Choi
2019-08-06 13:41       ` Leonard Crestez
2019-08-06 13:41         ` Leonard Crestez
2019-08-06 13:41         ` Leonard Crestez
2019-08-08 13:19         ` Artur Świgoń
2019-08-08 13:19           ` Artur Świgoń
2019-08-08 13:19           ` Artur Świgoń
     [not found]   ` <CGME20190723122029eucas1p21e1a51e759f9b605d2c89daf659af7bb@eucas1p2.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 10/11] arm: dts: exynos: Add interconnects to Exynos4412 mixer Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
     [not found]   ` <CGME20190723122029eucas1p2915f536d9ef43a7bd043a878a553439f@eucas1p2.samsung.com>
2019-07-23 12:20     ` [RFC PATCH 11/11] drm: exynos: mixer: Add interconnect support Artur Świgoń
2019-07-23 12:20       ` Artur Świgoń
2019-07-24 18:52       ` Krzysztof Kozlowski
2019-07-24 18:52         ` Krzysztof Kozlowski
2019-07-24 18:53   ` [RFC PATCH 00/11] Simple QoS for exynos-bus driver using interconnect Krzysztof Kozlowski
2019-07-24 18:53     ` Krzysztof Kozlowski
2019-07-24 18:53     ` Krzysztof Kozlowski
2019-08-13  6:17   ` Chanwoo Choi
2019-08-13  6:17     ` Chanwoo Choi
2019-08-13  6:19     ` Chanwoo Choi
2019-08-13  6:19       ` Chanwoo Choi

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=08bd637a-2038-9f64-a189-682427ce5bfb@samsung.com \
    --to=cw00.choi@samsung.com \
    --cc=a.swigon@partner.samsung.com \
    --cc=cpgs@samsung.com \
    --cc=devicetree@vger.kernel.org \
    --cc=dri-devel@lists.freedesktop.org \
    --cc=georgi.djakov@linaro.org \
    --cc=inki.dae@samsung.com \
    --cc=krzk@kernel.org \
    --cc=l.luba@partner.samsung.com \
    --cc=leonard.crestez@nxp.com \
    --cc=linux-arm-kernel@lists.infradead.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pm@vger.kernel.org \
    --cc=linux-samsung-soc@vger.kernel.org \
    --cc=m.szyprowski@samsung.com \
    --cc=myungjoo.ham@samsung.com \
    --cc=rafael@kernel.org \
    --cc=saravanak@google.com \
    --cc=sw0312.kim@samsung.com \
    --cc=viresh.kumar@linaro.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.