All of lore.kernel.org
 help / color / mirror / Atom feed
* [BlueZ PATCH v6] doc:adding definitions for load default params mgmt op
@ 2020-05-28 13:54 Alain Michaud
  2020-06-10  8:50 ` Marcel Holtmann
  0 siblings, 1 reply; 2+ messages in thread
From: Alain Michaud @ 2020-05-28 13:54 UTC (permalink / raw)
  To: linux-bluetooth; +Cc: Alain Michaud

This change adds the definition for the read/set default parameter
commands.

In particular, these commands are used to read and set the system
default parameters.  The use of a TLV format also ensures that
parameters are expandable in the future.

This will allow bluetoothd to load parameters from a conf file that may
be customized for the specific requirements of each platforms.

---

 doc/mgmt-api.txt | 113 +++++++++++++++++++++++++++++++++++++++++++++++
 1 file changed, 113 insertions(+)

diff --git a/doc/mgmt-api.txt b/doc/mgmt-api.txt
index 6ee01fed8..cbe6422a5 100644
--- a/doc/mgmt-api.txt
+++ b/doc/mgmt-api.txt
@@ -3223,6 +3223,119 @@ Set Experimental Feature Command
 				Invalid Index
 
 
+Read Default System Configuration Command
+=============================
+
+	Command Code:		0x004b
+	Controller Index:	<controller id>
+	Command Parameters:
+	Return Parameters:	Parameter1 {
+					Parameter_Type (2 Octet)
+					Value_Length (1 Octet)
+					Value (0-255 Octets)
+				}
+				Parameter2 { }
+				...
+
+	This command is used to read a list of default controller parameters.
+
+	Currently defined Parameter_Type values are:
+
+		0x0000	BR/EDR Page Scan Type
+		0x0001	BR/EDR Page Scan Interval
+		0x0002	BR/EDR Page Scan Window
+		0x0003	BR/EDR Inquiry Scan Type
+		0x0004	BR/EDR Inquiry Scan Interval
+		0x0005	BR/EDR Inquiry Scan Window
+		0x0006	BR/EDR Link Supervision Timeout
+		0x0007	BR/EDR Page Timeout
+		0x0008	BR/EDR Min Sniff Interval
+		0x0009	BR/EDR Max Sniff Interval
+		0x000a	LE Advertisement Min Interval
+		0x000b	LE Advertisement Max Interval
+		0x000c	LE Multi Advertisement Rotation Interval
+		0x000d	LE Scanning Interval for auto connect
+		0x000e	LE Scanning Window for auto connect
+		0x000f	LE Scanning Interval for wake scenarios
+		0x0010	LE Scanning Window for wake scenarios
+		0x0011	LE Scanning Interval for discovery
+		0x0012	LE Scanning Window for discovery
+		0x0013	LE Scanning Interval for adv monitoring
+		0x0014	LE Scanning Window for adv monitoring
+		0x0015	LE Scanning Interval for connect
+		0x0016	LE Scanning Window for connect
+		0x0017	LE Min Connection Interval
+		0x0018	LE Max Connection Interval
+		0x0019	LE Connection Latency
+		0x001a	LE Connection Supervision Timeout
+
+	This command can be used at any time and will return a list of supported
+	parameters as well as their current default value.
+
+	This command generates a Command Complete event on success or
+	a Command Status event on failure.
+
+	Possible errors:	Invalid Parameters
+				Invalid Index
+
+Set Default System Configuration Command
+=============================
+
+	Command Code:		0x004c
+	Controller Index:	<controller id>
+	Command Parameters:	Parameter1 {
+					Parameter_Type (2 Octet)
+					Value_Length (1 Octet)
+					Value (0-255 Octets)
+				}
+				Parameter2 { }
+				...
+	Return Parameters:
+
+	This command is used to set a list of default controller parameters.
+
+	Currently defined Parameter_Type values are:
+
+		0x0000	BR/EDR Page Scan Type
+		0x0001	BR/EDR Page Scan Interval
+		0x0002	BR/EDR Page Scan Window
+		0x0003	BR/EDR Inquiry Scan Type
+		0x0004	BR/EDR Inquiry Scan Interval
+		0x0005	BR/EDR Inquiry Scan Window
+		0x0006	BR/EDR Link Supervision Timeout
+		0x0007	BR/EDR Page Timeout
+		0x0008	BR/EDR Min Sniff Interval
+		0x0009	BR/EDR Max Sniff Interval
+		0x000a	LE Advertisement Min Interval
+		0x000b	LE Advertisement Max Interval
+		0x000c	LE Multi Advertisement Rotation Interval
+		0x000d	LE Scanning Interval for auto connect
+		0x000e	LE Scanning Window for auto connect
+		0x000f	LE Scanning Interval for wake scenarios
+		0x0010	LE Scanning Window for wake scenarios
+		0x0011	LE Scanning Interval for discovery
+		0x0012	LE Scanning Window for discovery
+		0x0013	LE Scanning Interval for adv monitoring
+		0x0014	LE Scanning Window for adv monitoring
+		0x0015	LE Scanning Interval for connect
+		0x0016	LE Scanning Window for connect
+		0x0017	LE Min Connection Interval
+		0x0018	LE Max Connection Interval
+		0x0019	LE Connection Latency
+		0x001a	LE Connection Supervision Timeout
+
+	This command can be used when the controller is not powered and
+	all supported parameters will be programmed once powered. Non supported
+	parameters will be ignored.  Note that these only control the default
+	parameters.  Higher level Apis may influence the effective value used.
+
+	This command generates a Command Complete event on success or
+	a Command Status event on failure.
+
+	Possible errors:	Invalid Parameters
+				Invalid Index
+
+
 Command Complete Event
 ======================
 
-- 
2.27.0.rc0.183.gde8f92d652-goog


^ permalink raw reply related	[flat|nested] 2+ messages in thread

end of thread, other threads:[~2020-06-10  8:50 UTC | newest]

Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2020-05-28 13:54 [BlueZ PATCH v6] doc:adding definitions for load default params mgmt op Alain Michaud
2020-06-10  8:50 ` Marcel Holtmann

This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.