From: "Álvaro Fernández Rojas" <noltari@gmail.com> To: hauke@hauke-m.de, zajec5@gmail.com, tsbogend@alpha.franken.de, robh+dt@kernel.org, f.fainelli@gmail.com, jonas.gorski@gmail.com, bcm-kernel-feedback-list@broadcom.com, linux-mips@vger.kernel.org, devicetree@vger.kernel.org, linux-kernel@vger.kernel.org, linux-arm-kernel@lists.infradead.org Cc: "Álvaro Fernández Rojas" <noltari@gmail.com> Subject: [PATCH v2 4/6] mips: bmips: dts: add BCM6362 power domain support Date: Wed, 10 Jun 2020 18:32:59 +0200 [thread overview] Message-ID: <20200610163301.461160-5-noltari@gmail.com> (raw) In-Reply-To: <20200610163301.461160-1-noltari@gmail.com> BCM6362 SoCs have a power domain controller to enable/disable certain components in order to save power. Signed-off-by: Álvaro Fernández Rojas <noltari@gmail.com> Acked-by: Florian Fainelli <f.fainelli@gmail.com> --- v2: Add dt-bindings header files. arch/mips/boot/dts/brcm/bcm6362.dtsi | 6 ++++++ include/dt-bindings/soc/bcm6362-pm.h | 21 +++++++++++++++++++++ 2 files changed, 27 insertions(+) create mode 100644 include/dt-bindings/soc/bcm6362-pm.h diff --git a/arch/mips/boot/dts/brcm/bcm6362.dtsi b/arch/mips/boot/dts/brcm/bcm6362.dtsi index 8ae6981735b8..c98f9111e3c8 100644 --- a/arch/mips/boot/dts/brcm/bcm6362.dtsi +++ b/arch/mips/boot/dts/brcm/bcm6362.dtsi @@ -108,6 +108,12 @@ uart1: serial@10000120 { status = "disabled"; }; + periph_pwr: power-controller@10001848 { + compatible = "brcm,bcm6362-power-controller"; + reg = <0x10001848 0x4>; + #power-domain-cells = <1>; + }; + leds0: led-controller@10001900 { #address-cells = <1>; #size-cells = <0>; diff --git a/include/dt-bindings/soc/bcm6362-pm.h b/include/dt-bindings/soc/bcm6362-pm.h new file mode 100644 index 000000000000..d087ba63c7a1 --- /dev/null +++ b/include/dt-bindings/soc/bcm6362-pm.h @@ -0,0 +1,21 @@ +/* SPDX-License-Identifier: GPL-2.0+ */ + +#ifndef __DT_BINDINGS_BMIPS_BCM6362_PM_H +#define __DT_BINDINGS_BMIPS_BCM6362_PM_H + +#define BCM6362_POWER_DOMAIN_SAR 0 +#define BCM6362_POWER_DOMAIN_IPSEC 1 +#define BCM6362_POWER_DOMAIN_MIPS 2 +#define BCM6362_POWER_DOMAIN_DECT 3 +#define BCM6362_POWER_DOMAIN_USBH 4 +#define BCM6362_POWER_DOMAIN_USBD 5 +#define BCM6362_POWER_DOMAIN_ROBOSW 6 +#define BCM6362_POWER_DOMAIN_PCM 7 +#define BCM6362_POWER_DOMAIN_PERIPH 8 +#define BCM6362_POWER_DOMAIN_ADSL_PHY 9 +#define BCM6362_POWER_DOMAIN_GMII_PADS 10 +#define BCM6362_POWER_DOMAIN_FAP 11 +#define BCM6362_POWER_DOMAIN_PCIE 12 +#define BCM6362_POWER_DOMAIN_WLAN_PADS 13 + +#endif /* __DT_BINDINGS_BMIPS_BCM6362_PM_H */ -- 2.26.2
WARNING: multiple messages have this Message-ID (diff)
From: "Álvaro Fernández Rojas" <noltari@gmail.com> To: hauke@hauke-m.de, zajec5@gmail.com, tsbogend@alpha.franken.de, robh+dt@kernel.org, f.fainelli@gmail.com, jonas.gorski@gmail.com, bcm-kernel-feedback-list@broadcom.com, linux-mips@vger.kernel.org, devicetree@vger.kernel.org, linux-kernel@vger.kernel.org, linux-arm-kernel@lists.infradead.org Cc: "Álvaro Fernández Rojas" <noltari@gmail.com> Subject: [PATCH v2 4/6] mips: bmips: dts: add BCM6362 power domain support Date: Wed, 10 Jun 2020 18:32:59 +0200 [thread overview] Message-ID: <20200610163301.461160-5-noltari@gmail.com> (raw) In-Reply-To: <20200610163301.461160-1-noltari@gmail.com> BCM6362 SoCs have a power domain controller to enable/disable certain components in order to save power. Signed-off-by: Álvaro Fernández Rojas <noltari@gmail.com> Acked-by: Florian Fainelli <f.fainelli@gmail.com> --- v2: Add dt-bindings header files. arch/mips/boot/dts/brcm/bcm6362.dtsi | 6 ++++++ include/dt-bindings/soc/bcm6362-pm.h | 21 +++++++++++++++++++++ 2 files changed, 27 insertions(+) create mode 100644 include/dt-bindings/soc/bcm6362-pm.h diff --git a/arch/mips/boot/dts/brcm/bcm6362.dtsi b/arch/mips/boot/dts/brcm/bcm6362.dtsi index 8ae6981735b8..c98f9111e3c8 100644 --- a/arch/mips/boot/dts/brcm/bcm6362.dtsi +++ b/arch/mips/boot/dts/brcm/bcm6362.dtsi @@ -108,6 +108,12 @@ uart1: serial@10000120 { status = "disabled"; }; + periph_pwr: power-controller@10001848 { + compatible = "brcm,bcm6362-power-controller"; + reg = <0x10001848 0x4>; + #power-domain-cells = <1>; + }; + leds0: led-controller@10001900 { #address-cells = <1>; #size-cells = <0>; diff --git a/include/dt-bindings/soc/bcm6362-pm.h b/include/dt-bindings/soc/bcm6362-pm.h new file mode 100644 index 000000000000..d087ba63c7a1 --- /dev/null +++ b/include/dt-bindings/soc/bcm6362-pm.h @@ -0,0 +1,21 @@ +/* SPDX-License-Identifier: GPL-2.0+ */ + +#ifndef __DT_BINDINGS_BMIPS_BCM6362_PM_H +#define __DT_BINDINGS_BMIPS_BCM6362_PM_H + +#define BCM6362_POWER_DOMAIN_SAR 0 +#define BCM6362_POWER_DOMAIN_IPSEC 1 +#define BCM6362_POWER_DOMAIN_MIPS 2 +#define BCM6362_POWER_DOMAIN_DECT 3 +#define BCM6362_POWER_DOMAIN_USBH 4 +#define BCM6362_POWER_DOMAIN_USBD 5 +#define BCM6362_POWER_DOMAIN_ROBOSW 6 +#define BCM6362_POWER_DOMAIN_PCM 7 +#define BCM6362_POWER_DOMAIN_PERIPH 8 +#define BCM6362_POWER_DOMAIN_ADSL_PHY 9 +#define BCM6362_POWER_DOMAIN_GMII_PADS 10 +#define BCM6362_POWER_DOMAIN_FAP 11 +#define BCM6362_POWER_DOMAIN_PCIE 12 +#define BCM6362_POWER_DOMAIN_WLAN_PADS 13 + +#endif /* __DT_BINDINGS_BMIPS_BCM6362_PM_H */ -- 2.26.2 _______________________________________________ linux-arm-kernel mailing list linux-arm-kernel@lists.infradead.org http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
next prev parent reply other threads:[~2020-06-10 16:33 UTC|newest] Thread overview: 116+ messages / expand[flat|nested] mbox.gz Atom feed top 2020-06-09 10:52 [PATCH 0/4] bmips: add BCM63xx power domain controller Álvaro Fernández Rojas 2020-06-09 10:52 ` Álvaro Fernández Rojas 2020-06-09 10:52 ` [PATCH 1/4] dt-bindings: soc: brcm: add BCM63xx power domain binding Álvaro Fernández Rojas 2020-06-09 10:52 ` Álvaro Fernández Rojas 2020-06-10 1:15 ` Florian Fainelli 2020-06-10 1:15 ` Florian Fainelli 2020-06-10 6:03 ` Álvaro Fernández Rojas 2020-06-10 6:03 ` Álvaro Fernández Rojas 2020-06-09 10:52 ` [PATCH 2/4] soc: bcm: add BCM63xx power domain driver Álvaro Fernández Rojas 2020-06-09 10:52 ` Álvaro Fernández Rojas 2020-06-10 2:19 ` Florian Fainelli 2020-06-10 2:19 ` Florian Fainelli 2020-06-09 10:52 ` [PATCH 3/4] mips: bmips: dts: add BCM6328 power domain support Álvaro Fernández Rojas 2020-06-09 10:52 ` Álvaro Fernández Rojas 2020-06-10 1:12 ` Florian Fainelli 2020-06-10 1:12 ` Florian Fainelli 2020-06-09 10:52 ` [PATCH 4/4] mips: bmips: dts: add BCM6362 " Álvaro Fernández Rojas 2020-06-09 10:52 ` Álvaro Fernández Rojas 2020-06-10 2:21 ` Florian Fainelli 2020-06-10 2:21 ` Florian Fainelli 2020-06-10 2:27 ` Florian Fainelli 2020-06-10 2:27 ` Florian Fainelli 2020-06-10 16:32 ` [PATCH v2 0/6] bmips: add BCM63xx power domain controller Álvaro Fernández Rojas 2020-06-10 16:32 ` Álvaro Fernández Rojas 2020-06-10 16:32 ` [PATCH v2 1/6] dt-bindings: soc: brcm: add BCM63xx power domain binding Álvaro Fernández Rojas 2020-06-10 16:32 ` Álvaro Fernández Rojas 2020-06-10 16:44 ` Florian Fainelli 2020-06-10 16:44 ` Florian Fainelli 2020-06-10 16:32 ` [PATCH v2 2/6] soc: bcm: add BCM63xx power domain driver Álvaro Fernández Rojas 2020-06-10 16:32 ` Álvaro Fernández Rojas 2020-06-10 16:49 ` Florian Fainelli 2020-06-10 16:49 ` Florian Fainelli 2020-06-10 16:32 ` [PATCH v2 3/6] mips: bmips: dts: add BCM6328 power domain support Álvaro Fernández Rojas 2020-06-10 16:32 ` Álvaro Fernández Rojas 2020-06-10 16:32 ` Álvaro Fernández Rojas [this message] 2020-06-10 16:32 ` [PATCH v2 4/6] mips: bmips: dts: add BCM6362 " Álvaro Fernández Rojas 2020-06-10 16:33 ` [PATCH v2 5/6] mips: bmips: dts: add BCM63268 " Álvaro Fernández Rojas 2020-06-10 16:33 ` Álvaro Fernández Rojas 2020-06-10 16:33 ` [PATCH v2 6/6] mips: bmips: add BCM6318 power domain definitions Álvaro Fernández Rojas 2020-06-10 16:33 ` Álvaro Fernández Rojas 2020-06-10 16:49 ` [PATCH v2 0/6] bmips: add BCM63xx power domain controller Florian Fainelli 2020-06-10 16:49 ` Florian Fainelli 2020-06-10 17:16 ` [PATCH v3 0/9] " Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-10 17:16 ` [PATCH v3 1/9] dt-bindings: soc: brcm: add BCM63xx power domain binding Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-12 21:55 ` Rob Herring 2020-06-12 21:55 ` Rob Herring 2020-06-12 21:56 ` Rob Herring 2020-06-12 21:56 ` Rob Herring 2020-06-10 17:16 ` [PATCH v3 2/9] mips: bmips: dts: add BCM6328 power domain definitions Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-10 17:16 ` [PATCH v3 3/9] mips: bmips: dts: add BCM6362 " Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-10 17:16 ` [PATCH v3 4/9] mips: bmips: dts: add BCM63268 " Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-10 17:16 ` [PATCH v3 5/9] mips: bmips: add BCM6318 " Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-10 17:16 ` [PATCH v3 6/9] soc: bcm: add BCM63xx power domain driver Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-10 17:16 ` [PATCH v3 7/9] mips: bmips: dts: add BCM6328 power domain support Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-10 17:16 ` [PATCH v3 8/9] mips: bmips: dts: add BCM6362 " Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-10 17:16 ` [PATCH v3 9/9] mips: bmips: dts: add BCM63268 " Álvaro Fernández Rojas 2020-06-10 17:16 ` Álvaro Fernández Rojas 2020-06-13 8:21 ` [PATCH v4 0/9] bmips: add BCM63xx power domain controller Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-06-13 8:21 ` [PATCH v4 1/9] dt-bindings: soc: brcm: add BCM63xx power domain binding Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-07-09 22:59 ` Rob Herring 2020-07-09 22:59 ` Rob Herring 2020-06-13 8:21 ` [PATCH v4 2/9] mips: bmips: add BCM6328 power domain definitions Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-06-14 4:45 ` Florian Fainelli 2020-06-14 4:45 ` Florian Fainelli 2020-07-09 23:00 ` Rob Herring 2020-07-09 23:00 ` Rob Herring 2020-06-13 8:21 ` [PATCH v4 3/9] mips: bmips: add BCM6362 " Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-06-14 4:46 ` Florian Fainelli 2020-06-14 4:46 ` Florian Fainelli 2020-07-09 23:00 ` Rob Herring 2020-07-09 23:00 ` Rob Herring 2020-06-13 8:21 ` [PATCH v4 4/9] mips: bmips: add BCM63268 " Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-06-14 4:46 ` Florian Fainelli 2020-06-14 4:46 ` Florian Fainelli 2020-07-09 23:01 ` Rob Herring 2020-07-09 23:01 ` Rob Herring 2020-06-13 8:21 ` [PATCH v4 5/9] mips: bmips: add BCM6318 " Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-06-14 4:46 ` Florian Fainelli 2020-06-14 4:46 ` Florian Fainelli 2020-07-09 23:01 ` Rob Herring 2020-07-09 23:01 ` Rob Herring 2020-06-13 8:21 ` [PATCH v4 6/9] soc: bcm: add BCM63xx power domain driver Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-06-14 4:48 ` Florian Fainelli 2020-06-14 4:48 ` Florian Fainelli 2020-06-13 8:21 ` [PATCH v4 7/9] mips: bmips: dts: add BCM6328 power domain support Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-07-23 9:10 ` Thomas Bogendoerfer 2020-07-23 9:10 ` Thomas Bogendoerfer 2020-06-13 8:21 ` [PATCH v4 8/9] mips: bmips: dts: add BCM6362 " Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-07-23 9:10 ` Thomas Bogendoerfer 2020-07-23 9:10 ` Thomas Bogendoerfer 2020-06-13 8:21 ` [PATCH v4 9/9] mips: bmips: dts: add BCM63268 " Álvaro Fernández Rojas 2020-06-13 8:21 ` Álvaro Fernández Rojas 2020-06-14 4:48 ` Florian Fainelli 2020-06-14 4:48 ` Florian Fainelli 2020-07-23 9:10 ` Thomas Bogendoerfer 2020-07-23 9:10 ` Thomas Bogendoerfer 2020-07-24 22:15 ` [PATCH v4 0/9] bmips: add BCM63xx power domain controller Florian Fainelli 2020-07-24 22:15 ` Florian Fainelli
Reply instructions: You may reply publicly to this message via plain-text email using any one of the following methods: * Save the following mbox file, import it into your mail client, and reply-to-all from there: mbox Avoid top-posting and favor interleaved quoting: https://en.wikipedia.org/wiki/Posting_style#Interleaved_style * Reply using the --to, --cc, and --in-reply-to switches of git-send-email(1): git send-email \ --in-reply-to=20200610163301.461160-5-noltari@gmail.com \ --to=noltari@gmail.com \ --cc=bcm-kernel-feedback-list@broadcom.com \ --cc=devicetree@vger.kernel.org \ --cc=f.fainelli@gmail.com \ --cc=hauke@hauke-m.de \ --cc=jonas.gorski@gmail.com \ --cc=linux-arm-kernel@lists.infradead.org \ --cc=linux-kernel@vger.kernel.org \ --cc=linux-mips@vger.kernel.org \ --cc=robh+dt@kernel.org \ --cc=tsbogend@alpha.franken.de \ --cc=zajec5@gmail.com \ /path/to/YOUR_REPLY https://kernel.org/pub/software/scm/git/docs/git-send-email.html * If your mail client supports setting the In-Reply-To header via mailto: links, try the mailto: linkBe sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes, see mirroring instructions on how to clone and mirror all data and code used by this external index.