All of lore.kernel.org
 help / color / mirror / Atom feed
From: Henning Schild <henning.schild@siemens.com>
To: linux-kernel@vger.kernel.org, linux-leds@vger.kernel.org,
	platform-driver-x86@vger.kernel.org,
	linux-watchdog@vger.kernel.org
Cc: Srikanth Krishnakar <skrishnakar@gmail.com>,
	Jan Kiszka <jan.kiszka@siemens.com>,
	Henning Schild <henning.schild@siemens.com>,
	Gerd Haeussler <gerd.haeussler.ext@siemens.com>,
	Guenter Roeck <linux@roeck-us.net>,
	Wim Van Sebroeck <wim@linux-watchdog.org>,
	Mark Gross <mgross@linux.intel.com>,
	Hans de Goede <hdegoede@redhat.com>, Pavel Machek <pavel@ucw.cz>,
	Andy Shevchenko <andy.shevchenko@gmail.com>,
	Michael Haener <michael.haener@siemens.com>
Subject: [PATCH v2 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs
Date: Mon, 15 Mar 2021 10:57:10 +0100	[thread overview]
Message-ID: <20210315095710.7140-5-henning.schild@siemens.com> (raw)
In-Reply-To: <20210315095710.7140-1-henning.schild@siemens.com>

Siemens industrial PCs unfortunately can not always be properly
identified the way we used to. An earlier commit introduced code that
allows proper identification without looking at DMI strings that could
differ based on product branding.
Switch over to that proper way and revert commits that used to collect
the machines based on unstable strings.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Fixes: e8796c6c69d1 ("platform/x86: pmc_atom: Add Siemens CONNECT ...")
Fixes: f110d252ae79 ("platform/x86: pmc_atom: Add Siemens SIMATIC ...")
Fixes: ad0d315b4d4e ("platform/x86: pmc_atom: Add Siemens SIMATIC ...")
Tested-by: Michael Haener <michael.haener@siemens.com>
Signed-off-by: Henning Schild <henning.schild@siemens.com>
---
 drivers/platform/x86/pmc_atom.c | 47 +++++++++++++++++++--------------
 1 file changed, 27 insertions(+), 20 deletions(-)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index ca684ed760d1..38542d547f29 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -13,6 +13,7 @@
 #include <linux/io.h>
 #include <linux/platform_data/x86/clk-pmc-atom.h>
 #include <linux/platform_data/x86/pmc_atom.h>
+#include <linux/platform_data/x86/simatic-ipc.h>
 #include <linux/platform_device.h>
 #include <linux/pci.h>
 #include <linux/seq_file.h>
@@ -362,6 +363,23 @@ static void pmc_dbgfs_register(struct pmc_dev *pmc)
 }
 #endif /* CONFIG_DEBUG_FS */
 
+static bool pmc_clk_is_critical = true;
+
+static int siemens_clk_is_critical(const struct dmi_system_id *d)
+{
+	u32 st_id;
+
+	if (dmi_walk(simatic_ipc_find_dmi_entry_helper, &st_id))
+		goto out;
+
+	if (st_id == SIMATIC_IPC_IPC227E || st_id == SIMATIC_IPC_IPC277E)
+		return 1;
+
+out:
+	pmc_clk_is_critical = false;
+	return 1;
+}
+
 /*
  * Some systems need one or more of their pmc_plt_clks to be
  * marked as critical.
@@ -424,24 +442,10 @@ static const struct dmi_system_id critclk_systems[] = {
 		},
 	},
 	{
-		.ident = "SIMATIC IPC227E",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
-			DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
-		},
-	},
-	{
-		.ident = "SIMATIC IPC277E",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
-			DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
-		},
-	},
-	{
-		.ident = "CONNECT X300",
+		.callback = siemens_clk_is_critical,
+		.ident = "SIEMENS AG",
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
-			DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
 		},
 	},
 
@@ -453,7 +457,7 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
 {
 	struct platform_device *clkdev;
 	struct pmc_clk_data *clk_data;
-	const struct dmi_system_id *d = dmi_first_match(critclk_systems);
+	const struct dmi_system_id *d;
 
 	clk_data = kzalloc(sizeof(*clk_data), GFP_KERNEL);
 	if (!clk_data)
@@ -461,9 +465,12 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
 
 	clk_data->base = pmc_regmap; /* offset is added by client */
 	clk_data->clks = pmc_data->clks;
-	if (d) {
-		clk_data->critical = true;
-		pr_info("%s critclks quirk enabled\n", d->ident);
+	if (dmi_check_system(critclk_systems)) {
+		clk_data->critical = pmc_clk_is_critical;
+		if (clk_data->critical) {
+			d = dmi_first_match(critclk_systems);
+			pr_info("%s critclks quirk enabled\n", d->ident);
+		}
 	}
 
 	clkdev = platform_device_register_data(&pdev->dev, "clk-pmc-atom",
-- 
2.26.2


  parent reply	other threads:[~2021-03-15  9:58 UTC|newest]

Thread overview: 44+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-03-15  9:57 [PATCH v2 0/4] add device drivers for Siemens Industrial PCs Henning Schild
2021-03-15  9:57 ` [PATCH v2 1/4] platform/x86: simatic-ipc: add main driver for Siemens devices Henning Schild
2021-03-15 10:31   ` Andy Shevchenko
2021-03-15 16:30     ` Henning Schild
2021-03-17 19:13     ` Henning Schild
2021-03-17 20:03       ` Hans de Goede
2021-03-18 11:30         ` Enrico Weigelt, metux IT consult
2021-03-18 11:45           ` Hans de Goede
2021-03-26  9:55             ` Henning Schild
2021-03-26 12:21               ` Hans de Goede
2021-03-15  9:57 ` [PATCH v2 2/4] leds: simatic-ipc-leds: add new driver for Siemens Industial PCs Henning Schild
2021-03-15 10:48   ` Andy Shevchenko
2021-03-15 11:19     ` Pavel Machek
2021-03-15 11:26       ` Andy Shevchenko
2021-03-15 12:40       ` Henning Schild
2021-03-18 11:38       ` Enrico Weigelt, metux IT consult
2021-03-27  9:46         ` Henning Schild
2021-04-01 16:20           ` Enrico Weigelt, metux IT consult
2021-03-27  9:56       ` Henning Schild
2021-03-18 10:27     ` Enrico Weigelt, metux IT consult
2021-03-18 12:40       ` Alexander Dahl
2021-03-23 17:45         ` Henning Schild
2021-03-26 16:33     ` Henning Schild
2021-03-18 10:25   ` Enrico Weigelt, metux IT consult
2021-03-27 11:16     ` Henning Schild
2021-03-27 11:41       ` Henning Schild
2021-03-15  9:57 ` [PATCH v2 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs Henning Schild
2021-03-15 15:10   ` Guenter Roeck
2021-03-29 16:28     ` Henning Schild
2021-03-15  9:57 ` Henning Schild [this message]
2021-03-15 10:14   ` [PATCH v2 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs Henning Schild
2021-03-15 10:19     ` Hans de Goede
2021-03-15 12:09       ` Henning Schild
2021-03-15 14:58       ` [PATCH] platform/x86: pmc_atom: use callback for all dmi quirk entries Henning Schild
2021-03-15 16:31         ` Hans de Goede
2021-03-15 17:00           ` Henning Schild
2021-03-15 18:01             ` Hans de Goede
2021-03-16  5:47               ` Henning Schild
2021-03-16  9:43                 ` Hans de Goede
2021-03-15 13:25   ` [PATCH v2 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs kernel test robot
2021-03-15 13:25     ` kernel test robot
2021-03-15 10:55 ` [PATCH v2 0/4] add device drivers for Siemens Industrial PCs Andy Shevchenko
2021-03-15 16:08   ` Henning Schild
2021-08-02  9:21   ` Henning Schild

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20210315095710.7140-5-henning.schild@siemens.com \
    --to=henning.schild@siemens.com \
    --cc=andy.shevchenko@gmail.com \
    --cc=gerd.haeussler.ext@siemens.com \
    --cc=hdegoede@redhat.com \
    --cc=jan.kiszka@siemens.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-leds@vger.kernel.org \
    --cc=linux-watchdog@vger.kernel.org \
    --cc=linux@roeck-us.net \
    --cc=mgross@linux.intel.com \
    --cc=michael.haener@siemens.com \
    --cc=pavel@ucw.cz \
    --cc=platform-driver-x86@vger.kernel.org \
    --cc=skrishnakar@gmail.com \
    --cc=wim@linux-watchdog.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.