* [lm-sensors] PATCH: hwmon-f71882fg-16-add-and-update-doc.patch
@ 2008-12-15 13:31 Hans de Goede
2008-12-15 16:26 ` Jean Delvare
` (2 more replies)
0 siblings, 3 replies; 4+ messages in thread
From: Hans de Goede @ 2008-12-15 13:31 UTC (permalink / raw)
To: lm-sensors
[-- Attachment #1: Type: text/plain, Size: 210 bytes --]
Hi Jean,
Add some documentation about the f71882fg driver, and update the Kconfig
documentation to report the new supported models.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Thanks & Regards,
Hans
[-- Attachment #2: hwmon-f71882fg-16-add-and-update-doc.patch --]
[-- Type: text/plain, Size: 4868 bytes --]
Add some documentation about the f71882fg driver, and update the Kconfig
documentation to report the new supported models.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
diff -up vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg.foo vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg
--- vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg.foo 2008-12-15 13:21:31.000000000 +0100
+++ vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg 2008-12-15 14:25:54.000000000 +0100
@@ -0,0 +1,89 @@
+Kernel driver f71882fg
+======================
+
+Supported chips:
+ * Fintek F71882FG or F71883FG
+ Prefix: 'f71882fg'
+ Addresses scanned: none, address read from Super I/O config space
+ Datasheet: Available from the Fintek website
+ * Fintek F71862FG or F71863FG
+ Prefix: 'f71862fg'
+ Addresses scanned: none, address read from Super I/O config space
+ Datasheet: Available from the Fintek website
+ * Fintek F8000
+ Prefix: 'f8000'
+ Addresses scanned: none, address read from Super I/O config space
+ Datasheet: Not public
+
+Author: Hans de Goede <hdegoede@redhat.com>
+
+
+Description
+-----------
+
+The Fintek F718xxFG/F8000 Super I/O chip includes complete hardware monitoring
+capabilities. It can monitor up to 9 voltages (3 for the F8000), 4 fans and
+3 temperature sensors.
+
+This chip also has fan controlling features, using either DC or PWM, in
+three different modes (one manual, two automatic).
+
+The driver assumes that no more than one chip is present, which seems
+reasonable.
+
+
+Monitoring
+----------
+
+The Voltage, Fan and Temperature Monitoring uses the standard sysfs
+interface as documented in sysfs-interface, without any exceptions.
+
+
+Fan Control
+-----------
+
+Both PWM (pulse-width modulation) and DC fan speed control methods are
+supported. The right one to use depends on external circuitry on the
+motherboard, so the driver assumes that the BIOS set the method
+properly.
+
+There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC
+voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM
+mode where the actual RPM of the fan (as measured) is controled and the speed
+gets specified as 0-100% of the fan#_full_speed file.
+
+Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a
+whole lot of a difference when modifying fan control settings. The only
+important difference is that in RPM mode the 0-100% controls the fan speed
+between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs
+RPM mode, it will also set fan#_full_speed properly, if it does not then
+fan control will not work properly, unless you set a sane fan#_full_speed
+value yourself.
+
+Switching between these modes requires re-initializing a whole bunch of
+registers, so the mode which the BIOS has set is kept. The mode is
+printed when loading the driver.
+
+Three different fan control modes are supported; the mode number is written
+to the pwm<n>_enable file. Note that not all modes are supported on all
+chips, and some modes may only be available in RPM / PWM mode on the F8000.
+Writing an unsupported mode will result in an invalid parameter error.
+
+* 1: Manual mode
+ You ask for a specific PWM duty cycle / DC voltage or a specific % of
+ fan#_full_speed by writing to the pwm<n> file. This mode is only
+ available on the F8000 if the fan channel is in RPM mode.
+
+* 2: Normal auto mode
+ You can define a number of temperature/fan speed trip points, which % the
+ fan should run at at this temp and which temp a fan should follow using the
+ standard sysfs interface. The number and type of trip points is chip
+ depended, see which files are available in sysfs.
+ Fan/PWM channel 3 of the F8000 is always in this mode!
+
+* 3: Thermostat mode (Only available on the F8000 when in duty cycle mode)
+ The fan speed is regulated to keep the temp the fan is mapped to between
+ temp#_auto_point2_temp and temp#_auto_point3_temp.
+
+Both of the automatic modes require that pwm1 corresponds to fan1, pwm2 to
+fan2 and pwm3 to fan3.
diff -up vanilla-2.6.28-rc8/drivers/hwmon/Kconfig.foo vanilla-2.6.28-rc8/drivers/hwmon/Kconfig
--- vanilla-2.6.28-rc8/drivers/hwmon/Kconfig.foo 2008-12-15 14:26:14.000000000 +0100
+++ vanilla-2.6.28-rc8/drivers/hwmon/Kconfig 2008-12-15 14:27:32.000000000 +0100
@@ -284,11 +284,12 @@ config SENSORS_F71805F
will be called f71805f.
config SENSORS_F71882FG
- tristate "Fintek F71882FG and F71883FG"
+ tristate "Fintek F71862FG, F71882FG and F8000"
depends on EXPERIMENTAL
help
If you say yes here you get support for hardware monitoring
- features of the Fintek F71882FG and F71883FG Super-I/O chips.
+ features of the Fintek F71882FG/F71883FG, F71862FG/71863FG
+ and F8000 Super-I/O chips.
This driver can also be built as a module. If so, the module
will be called f71882fg.
[-- Attachment #3: Type: text/plain, Size: 153 bytes --]
_______________________________________________
lm-sensors mailing list
lm-sensors@lm-sensors.org
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
^ permalink raw reply [flat|nested] 4+ messages in thread
* Re: [lm-sensors] PATCH: hwmon-f71882fg-16-add-and-update-doc.patch
2008-12-15 13:31 [lm-sensors] PATCH: hwmon-f71882fg-16-add-and-update-doc.patch Hans de Goede
@ 2008-12-15 16:26 ` Jean Delvare
2008-12-15 22:39 ` Hans de Goede
2008-12-16 8:24 ` Jean Delvare
2 siblings, 0 replies; 4+ messages in thread
From: Jean Delvare @ 2008-12-15 16:26 UTC (permalink / raw)
To: lm-sensors
On Mon, 15 Dec 2008 14:31:08 +0100, Hans de Goede wrote:
> Hi Jean,
>
> Add some documentation about the f71882fg driver, and update the Kconfig
> documentation to report the new supported models.
>
> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Review:
> Add some documentation about the f71882fg driver, and update the Kconfig
> documentation to report the new supported models.
>
> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
> diff -up vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg.foo vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg
> --- vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg.foo 2008-12-15 13:21:31.000000000 +0100
> +++ vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg 2008-12-15 14:25:54.000000000 +0100
> @@ -0,0 +1,89 @@
> +Kernel driver f71882fg
> +===========
> +
> +Supported chips:
> + * Fintek F71882FG or F71883FG
I certainly hope this is "and", not "or" ;)
> + Prefix: 'f71882fg'
> + Addresses scanned: none, address read from Super I/O config space
> + Datasheet: Available from the Fintek website
> + * Fintek F71862FG or F71863FG
Ditto.
> + Prefix: 'f71862fg'
> + Addresses scanned: none, address read from Super I/O config space
> + Datasheet: Available from the Fintek website
> + * Fintek F8000
> + Prefix: 'f8000'
> + Addresses scanned: none, address read from Super I/O config space
> + Datasheet: Not public
> +
> +Author: Hans de Goede <hdegoede@redhat.com>
> +
> +
> +Description
> +-----------
> +
> +The Fintek F718xxFG/F8000 Super I/O chip includes complete hardware monitoring
> +capabilities. It can monitor up to 9 voltages (3 for the F8000), 4 fans and
> +3 temperature sensors.
The use of a singular to designate 3 different chips sounds strange
IMHO.
> +
> +This chip also has fan controlling features, using either DC or PWM, in
> +three different modes (one manual, two automatic).
> +
> +The driver assumes that no more than one chip is present, which seems
> +reasonable.
> +
> +
> +Monitoring
> +----------
> +
> +The Voltage, Fan and Temperature Monitoring uses the standard sysfs
> +interface as documented in sysfs-interface, without any exceptions.
> +
> +
> +Fan Control
> +-----------
> +
> +Both PWM (pulse-width modulation) and DC fan speed control methods are
> +supported. The right one to use depends on external circuitry on the
> +motherboard, so the driver assumes that the BIOS set the method
> +properly.
> +
> +There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC
> +voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM
> +mode where the actual RPM of the fan (as measured) is controled and the speed
Spelling: controlled.
> +gets specified as 0-100% of the fan#_full_speed file.
> +
> +Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a
> +whole lot of a difference when modifying fan control settings. The only
> +important difference is that in RPM mode the 0-100% controls the fan speed
> +between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs
> +RPM mode, it will also set fan#_full_speed properly, if it does not then
> +fan control will not work properly, unless you set a sane fan#_full_speed
> +value yourself.
> +
> +Switching between these modes requires re-initializing a whole bunch of
> +registers, so the mode which the BIOS has set is kept. The mode is
> +printed when loading the driver.
> +
> +Three different fan control modes are supported; the mode number is written
> +to the pwm<n>_enable file. Note that not all modes are supported on all
This mix of # and <n> for channel number is a bit confusing.
> +chips, and some modes may only be available in RPM / PWM mode on the F8000.
> +Writing an unsupported mode will result in an invalid parameter error.
> +
> +* 1: Manual mode
> + You ask for a specific PWM duty cycle / DC voltage or a specific % of
> + fan#_full_speed by writing to the pwm<n> file. This mode is only
> + available on the F8000 if the fan channel is in RPM mode.
> +
> +* 2: Normal auto mode
> + You can define a number of temperature/fan speed trip points, which % the
> + fan should run at at this temp and which temp a fan should follow using the
> + standard sysfs interface. The number and type of trip points is chip
> + depended, see which files are available in sysfs.
> + Fan/PWM channel 3 of the F8000 is always in this mode!
> +
> +* 3: Thermostat mode (Only available on the F8000 when in duty cycle mode)
> + The fan speed is regulated to keep the temp the fan is mapped to between
> + temp#_auto_point2_temp and temp#_auto_point3_temp.
> +
> +Both of the automatic modes require that pwm1 corresponds to fan1, pwm2 to
> +fan2 and pwm3 to fan3.
> diff -up vanilla-2.6.28-rc8/drivers/hwmon/Kconfig.foo vanilla-2.6.28-rc8/drivers/hwmon/Kconfig
> --- vanilla-2.6.28-rc8/drivers/hwmon/Kconfig.foo 2008-12-15 14:26:14.000000000 +0100
> +++ vanilla-2.6.28-rc8/drivers/hwmon/Kconfig 2008-12-15 14:27:32.000000000 +0100
> @@ -284,11 +284,12 @@ config SENSORS_F71805F
> will be called f71805f.
>
> config SENSORS_F71882FG
> - tristate "Fintek F71882FG and F71883FG"
> + tristate "Fintek F71862FG, F71882FG and F8000"
> depends on EXPERIMENTAL
> help
> If you say yes here you get support for hardware monitoring
> - features of the Fintek F71882FG and F71883FG Super-I/O chips.
> + features of the Fintek F71882FG/F71883FG, F71862FG/71863FG
> + and F8000 Super-I/O chips.
>
> This driver can also be built as a module. If so, the module
> will be called f71882fg.
--
Jean Delvare
_______________________________________________
lm-sensors mailing list
lm-sensors@lm-sensors.org
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
^ permalink raw reply [flat|nested] 4+ messages in thread
* Re: [lm-sensors] PATCH: hwmon-f71882fg-16-add-and-update-doc.patch
2008-12-15 13:31 [lm-sensors] PATCH: hwmon-f71882fg-16-add-and-update-doc.patch Hans de Goede
2008-12-15 16:26 ` Jean Delvare
@ 2008-12-15 22:39 ` Hans de Goede
2008-12-16 8:24 ` Jean Delvare
2 siblings, 0 replies; 4+ messages in thread
From: Hans de Goede @ 2008-12-15 22:39 UTC (permalink / raw)
To: lm-sensors
[-- Attachment #1: Type: text/plain, Size: 5850 bytes --]
Jean Delvare wrote:
> On Mon, 15 Dec 2008 14:31:08 +0100, Hans de Goede wrote:
>> Hi Jean,
>>
>> Add some documentation about the f71882fg driver, and update the Kconfig
>> documentation to report the new supported models.
>>
>> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
>
> Review:
>
Thanks, updated version with all found issues fixed attached.
Regards,
Hans
>> Add some documentation about the f71882fg driver, and update the Kconfig
>> documentation to report the new supported models.
>>
>> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
>> diff -up vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg.foo vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg
>> --- vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg.foo 2008-12-15 13:21:31.000000000 +0100
>> +++ vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg 2008-12-15 14:25:54.000000000 +0100
>> @@ -0,0 +1,89 @@
>> +Kernel driver f71882fg
>> +======================
>> +
>> +Supported chips:
>> + * Fintek F71882FG or F71883FG
>
> I certainly hope this is "and", not "or" ;)
>
>> + Prefix: 'f71882fg'
>> + Addresses scanned: none, address read from Super I/O config space
>> + Datasheet: Available from the Fintek website
>> + * Fintek F71862FG or F71863FG
>
> Ditto.
>
>> + Prefix: 'f71862fg'
>> + Addresses scanned: none, address read from Super I/O config space
>> + Datasheet: Available from the Fintek website
>> + * Fintek F8000
>> + Prefix: 'f8000'
>> + Addresses scanned: none, address read from Super I/O config space
>> + Datasheet: Not public
>> +
>> +Author: Hans de Goede <hdegoede@redhat.com>
>> +
>> +
>> +Description
>> +-----------
>> +
>> +The Fintek F718xxFG/F8000 Super I/O chip includes complete hardware monitoring
>> +capabilities. It can monitor up to 9 voltages (3 for the F8000), 4 fans and
>> +3 temperature sensors.
>
> The use of a singular to designate 3 different chips sounds strange
> IMHO.
>
>> +
>> +This chip also has fan controlling features, using either DC or PWM, in
>> +three different modes (one manual, two automatic).
>> +
>> +The driver assumes that no more than one chip is present, which seems
>> +reasonable.
>> +
>> +
>> +Monitoring
>> +----------
>> +
>> +The Voltage, Fan and Temperature Monitoring uses the standard sysfs
>> +interface as documented in sysfs-interface, without any exceptions.
>> +
>> +
>> +Fan Control
>> +-----------
>> +
>> +Both PWM (pulse-width modulation) and DC fan speed control methods are
>> +supported. The right one to use depends on external circuitry on the
>> +motherboard, so the driver assumes that the BIOS set the method
>> +properly.
>> +
>> +There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC
>> +voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM
>> +mode where the actual RPM of the fan (as measured) is controled and the speed
>
> Spelling: controlled.
>
>> +gets specified as 0-100% of the fan#_full_speed file.
>> +
>> +Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a
>> +whole lot of a difference when modifying fan control settings. The only
>> +important difference is that in RPM mode the 0-100% controls the fan speed
>> +between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs
>> +RPM mode, it will also set fan#_full_speed properly, if it does not then
>> +fan control will not work properly, unless you set a sane fan#_full_speed
>> +value yourself.
>> +
>> +Switching between these modes requires re-initializing a whole bunch of
>> +registers, so the mode which the BIOS has set is kept. The mode is
>> +printed when loading the driver.
>> +
>> +Three different fan control modes are supported; the mode number is written
>> +to the pwm<n>_enable file. Note that not all modes are supported on all
>
> This mix of # and <n> for channel number is a bit confusing.
>
>> +chips, and some modes may only be available in RPM / PWM mode on the F8000.
>> +Writing an unsupported mode will result in an invalid parameter error.
>> +
>> +* 1: Manual mode
>> + You ask for a specific PWM duty cycle / DC voltage or a specific % of
>> + fan#_full_speed by writing to the pwm<n> file. This mode is only
>> + available on the F8000 if the fan channel is in RPM mode.
>> +
>> +* 2: Normal auto mode
>> + You can define a number of temperature/fan speed trip points, which % the
>> + fan should run at at this temp and which temp a fan should follow using the
>> + standard sysfs interface. The number and type of trip points is chip
>> + depended, see which files are available in sysfs.
>> + Fan/PWM channel 3 of the F8000 is always in this mode!
>> +
>> +* 3: Thermostat mode (Only available on the F8000 when in duty cycle mode)
>> + The fan speed is regulated to keep the temp the fan is mapped to between
>> + temp#_auto_point2_temp and temp#_auto_point3_temp.
>> +
>> +Both of the automatic modes require that pwm1 corresponds to fan1, pwm2 to
>> +fan2 and pwm3 to fan3.
>> diff -up vanilla-2.6.28-rc8/drivers/hwmon/Kconfig.foo vanilla-2.6.28-rc8/drivers/hwmon/Kconfig
>> --- vanilla-2.6.28-rc8/drivers/hwmon/Kconfig.foo 2008-12-15 14:26:14.000000000 +0100
>> +++ vanilla-2.6.28-rc8/drivers/hwmon/Kconfig 2008-12-15 14:27:32.000000000 +0100
>> @@ -284,11 +284,12 @@ config SENSORS_F71805F
>> will be called f71805f.
>>
>> config SENSORS_F71882FG
>> - tristate "Fintek F71882FG and F71883FG"
>> + tristate "Fintek F71862FG, F71882FG and F8000"
>> depends on EXPERIMENTAL
>> help
>> If you say yes here you get support for hardware monitoring
>> - features of the Fintek F71882FG and F71883FG Super-I/O chips.
>> + features of the Fintek F71882FG/F71883FG, F71862FG/71863FG
>> + and F8000 Super-I/O chips.
>>
>> This driver can also be built as a module. If so, the module
>> will be called f71882fg.
>
>
>
[-- Attachment #2: hwmon-f71882fg-16-add-and-update-doc-v2.patch --]
[-- Type: text/plain, Size: 4868 bytes --]
Add some documentation about the f71882fg driver, and update the Kconfig
documentation to report the new supported models.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
diff -up vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg.foo vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg
--- vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg.foo 2008-12-15 13:21:31.000000000 +0100
+++ vanilla-2.6.28-rc8/Documentation/hwmon/f71882fg 2008-12-15 14:25:54.000000000 +0100
@@ -0,0 +1,89 @@
+Kernel driver f71882fg
+======================
+
+Supported chips:
+ * Fintek F71882FG and F71883FG
+ Prefix: 'f71882fg'
+ Addresses scanned: none, address read from Super I/O config space
+ Datasheet: Available from the Fintek website
+ * Fintek F71862FG and F71863FG
+ Prefix: 'f71862fg'
+ Addresses scanned: none, address read from Super I/O config space
+ Datasheet: Available from the Fintek website
+ * Fintek F8000
+ Prefix: 'f8000'
+ Addresses scanned: none, address read from Super I/O config space
+ Datasheet: Not public
+
+Author: Hans de Goede <hdegoede@redhat.com>
+
+
+Description
+-----------
+
+Fintek F718xxFG/F8000 Super I/O chips include complete hardware monitoring
+capabilities. They can monitor up to 9 voltages (3 for the F8000), 4 fans and
+3 temperature sensors.
+
+These chips also have fan controlling features, using either DC or PWM, in
+three different modes (one manual, two automatic).
+
+The driver assumes that no more than one chip is present, which seems
+reasonable.
+
+
+Monitoring
+----------
+
+The Voltage, Fan and Temperature Monitoring uses the standard sysfs
+interface as documented in sysfs-interface, without any exceptions.
+
+
+Fan Control
+-----------
+
+Both PWM (pulse-width modulation) and DC fan speed control methods are
+supported. The right one to use depends on external circuitry on the
+motherboard, so the driver assumes that the BIOS set the method
+properly.
+
+There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC
+voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM
+mode where the actual RPM of the fan (as measured) is controlled and the speed
+gets specified as 0-100% of the fan#_full_speed file.
+
+Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a
+whole lot of a difference when modifying fan control settings. The only
+important difference is that in RPM mode the 0-100% controls the fan speed
+between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs
+RPM mode, it will also set fan#_full_speed properly, if it does not then
+fan control will not work properly, unless you set a sane fan#_full_speed
+value yourself.
+
+Switching between these modes requires re-initializing a whole bunch of
+registers, so the mode which the BIOS has set is kept. The mode is
+printed when loading the driver.
+
+Three different fan control modes are supported; the mode number is written
+to the pwm#_enable file. Note that not all modes are supported on all
+chips, and some modes may only be available in RPM / PWM mode on the F8000.
+Writing an unsupported mode will result in an invalid parameter error.
+
+* 1: Manual mode
+ You ask for a specific PWM duty cycle / DC voltage or a specific % of
+ fan#_full_speed by writing to the pwm# file. This mode is only
+ available on the F8000 if the fan channel is in RPM mode.
+
+* 2: Normal auto mode
+ You can define a number of temperature/fan speed trip points, which % the
+ fan should run at at this temp and which temp a fan should follow using the
+ standard sysfs interface. The number and type of trip points is chip
+ depended, see which files are available in sysfs.
+ Fan/PWM channel 3 of the F8000 is always in this mode!
+
+* 3: Thermostat mode (Only available on the F8000 when in duty cycle mode)
+ The fan speed is regulated to keep the temp the fan is mapped to between
+ temp#_auto_point2_temp and temp#_auto_point3_temp.
+
+Both of the automatic modes require that pwm1 corresponds to fan1, pwm2 to
+fan2 and pwm3 to fan3.
diff -up vanilla-2.6.28-rc8/drivers/hwmon/Kconfig.foo vanilla-2.6.28-rc8/drivers/hwmon/Kconfig
--- vanilla-2.6.28-rc8/drivers/hwmon/Kconfig.foo 2008-12-15 14:26:14.000000000 +0100
+++ vanilla-2.6.28-rc8/drivers/hwmon/Kconfig 2008-12-15 14:27:32.000000000 +0100
@@ -284,11 +284,12 @@ config SENSORS_F71805F
will be called f71805f.
config SENSORS_F71882FG
- tristate "Fintek F71882FG and F71883FG"
+ tristate "Fintek F71862FG, F71882FG and F8000"
depends on EXPERIMENTAL
help
If you say yes here you get support for hardware monitoring
- features of the Fintek F71882FG and F71883FG Super-I/O chips.
+ features of the Fintek F71882FG/F71883FG, F71862FG/71863FG
+ and F8000 Super-I/O chips.
This driver can also be built as a module. If so, the module
will be called f71882fg.
[-- Attachment #3: Type: text/plain, Size: 153 bytes --]
_______________________________________________
lm-sensors mailing list
lm-sensors@lm-sensors.org
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
^ permalink raw reply [flat|nested] 4+ messages in thread
* Re: [lm-sensors] PATCH: hwmon-f71882fg-16-add-and-update-doc.patch
2008-12-15 13:31 [lm-sensors] PATCH: hwmon-f71882fg-16-add-and-update-doc.patch Hans de Goede
2008-12-15 16:26 ` Jean Delvare
2008-12-15 22:39 ` Hans de Goede
@ 2008-12-16 8:24 ` Jean Delvare
2 siblings, 0 replies; 4+ messages in thread
From: Jean Delvare @ 2008-12-16 8:24 UTC (permalink / raw)
To: lm-sensors
On Mon, 15 Dec 2008 23:39:35 +0100, Hans de Goede wrote:
> Jean Delvare wrote:
> > On Mon, 15 Dec 2008 14:31:08 +0100, Hans de Goede wrote:
> >> Hi Jean,
> >>
> >> Add some documentation about the f71882fg driver, and update the Kconfig
> >> documentation to report the new supported models.
> >>
> >> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
> >
> > Review:
>
> Thanks, updated version with all found issues fixed attached.
Applied, thanks.
--
Jean Delvare
_______________________________________________
lm-sensors mailing list
lm-sensors@lm-sensors.org
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
^ permalink raw reply [flat|nested] 4+ messages in thread
end of thread, other threads:[~2008-12-16 8:24 UTC | newest]
Thread overview: 4+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2008-12-15 13:31 [lm-sensors] PATCH: hwmon-f71882fg-16-add-and-update-doc.patch Hans de Goede
2008-12-15 16:26 ` Jean Delvare
2008-12-15 22:39 ` Hans de Goede
2008-12-16 8:24 ` Jean Delvare
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.