* Re: VGA passthrough on unstable
@ 2011-05-17 23:14 Liwei
  0 siblings, 0 replies; 21+ messages in thread
From: Liwei @ 2011-05-17 23:14 UTC (permalink / raw)
  To: konrad.wilk; +Cc: xen-devel

>Date: Tue, 10 May 2011 13:55:04 -0400
>From: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
>Subject: Re: [Xen-devel] Re: VGA passthrough on unstable
>To: JavMV <javiapple@hotmail.com>
>Cc: xen-devel@lists.xensource.com
>Message-ID: <20110510175504.GA15697@dumpdata.com>
>Content-Type: text/plain; charset=us-ascii
>
>> How can i fix this?
>> Is the patch hvmloader already applied in xen-unstable4.2?
>> Is there any difference between using pci-stub instead of pciback?
>
>Not for HVM guests.
>>
>> With these 2 patches applied I cannot run the virtual machine neither with
>> gfx_passthru = 0, but without those patches i was able to do it and was able
>> to see the Nvidia Card inside Windows but with error code43 and a yellow
>> exclamation symbol...
>
>Hmm, Does the error code show up anything on Google?

Whoops, I didn't notice there was a response to my post.

I did do a search but that is a pretty generic error Windows gives
when the driver decides something is wrong. No way of knowing
precisely what unless the driver spews some information somewhere
(which I think is unlikely).

However come to think of it, I did encounter that message twice
before. Once when I tested with PCI passthrough in ESXi and the other
time when the stock xen corrupted my card's firmware (I think, had to
reflash the backup firmware with nvflash for the card to work again).

So I guess in this case it may be due to the card being in an unknown
state when the driver is loaded? What if I made a change in xen to
execute card firmware even if gfx_passthrough = 0, without all the
modifications required for VGA passthrough? Though I suspect the
firmware expects some of the special VGA address mapping?

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
@ 2011-05-31 14:59 Liwei
  0 siblings, 0 replies; 21+ messages in thread
From: Liwei @ 2011-05-31 14:59 UTC (permalink / raw)
  To: Pasi Kärkkäinen; +Cc: xen-devel, xen-users

Hello Pasi, list,
   Just to update that the ATI passthrough patch works fine on the HD
6870 (Yeah, went ahead and bought one). On the vanilla xen, it almost
works (with quirks) as a secondary adaptor (i.e. gfx_passthrough = 0).
   This is after a few hours "testing" out both setups (patch and
vanilla) using Portal 2. The game did crash once every 20 minutes or
so using the vanilla xen, but was absolutely stable using the patch.
3DMark05 gave a score of about 18400 in both setups, which seem
congruent with the scores from this graphics chip.
   So IMHO, if anybody wants to do graphics passthrough, definitely
go for an ATI card.

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-24 15:35 Liwei
@ 2011-05-24 15:44 ` Liwei
  0 siblings, 0 replies; 21+ messages in thread
From: Liwei @ 2011-05-24 15:44 UTC (permalink / raw)
  To: xen-devel, xen-users

[-- Attachment #1: Type: text/plain, Size: 3965 bytes --]

Oh, I forgot to mention that there was a kernel bugcheck logged after
the first two tries. See attached.

On 24 May 2011 23:35, Liwei <xieliwei@gmail.com> wrote:
> Hello all,
>    I've made some progress after manually editing dsdt.asl to reserve
> my card's memory ranges based on lspci, and fixing a bug in the
> previous patch where a pair of braces were missing causing the wrong
> video BIOS to be loaded. The fixed patch is attached. Do take note
> that I've also removed the changes for secondary card passthrough.
>    With those changes I am able to boot into Windows with the driver
> installed (Fresh install with gfx_passthrough = 0). Logging in using
> remote desktop, I can see that the driver is active. I also see that
> screen spanning is active as I can move my mouse pointer between both
> monitors. Everything looks good - until I tried to physically login.
>    First two tries:
>        The login screen disappears, leaving both screens black with
> my cursor free to move around. After a few seconds, the whole system
> (Dom0 + DomU) locks up. The reset button didn't work as normal;
> usually pressing it will immediately reboot the PC, but this time it
> had no response for a few seconds, then it shut down, and almost
> immediately started again, returning back to normal. Weird.
>        The logs from qemu and syslog didn't show anything special
> happening before and up to the lockup. xl dmesg didn't throw up
> anything interesting before the lockup either, though that was viewed
> through a script that repeatedly calls xl dmesg over a ssh connection.
>
>    After that, I tried to compare the memory ranges from Device
> Manager to the ranges specified in dsdt.asl. Matches. But I also
> noticed the original PCI memory reserve overlapped with the range of
> the card. Not sure whether that was bad, but I pushed the range back
> anyways and tried again.
>    Third and subsequent tries:
>        After logging in, but before the login screen disappears, the
> DomU reboots. I didn't see any BSOD flash by but a minidump appears.
> Analysing it gives me the following:
>        VIDEO_TDR_FAILURE (116)
>        Attempt to reset the display driver and recover from timeout failed.
>        Arguments:
>        Arg1: fffffa8003bdb010, Optional pointer to internal TDR recovery
> context (TDR_RECOVERY_CONTEXT).
>        Arg2: fffff8800f204520, The pointer into responsible device driver
> module (e.g. owner tag).
>        Arg3: 0000000000000000, Optional error code (NTSTATUS) of the last
> failed operation.
>        Arg4: 0000000000000002, Optional internal context dependent data.
>        Also I noticed that if the display goes into suspend, it never
> comes back. I'm still able to do stuff over remote desktop though.
>
>    Sometimes I get the following minidump too, even in a remote
> desktop session:
>        BUGCODE_USB_DRIVER (fe)
>        USB Driver bugcheck, first parameter is USB bugcheck code.
>        Arguments:
>        Arg1: 0000000000000008, USBBUGCODE_RESERVED_USBHUB
>        Arg2: 0000000000000006, USBHUB_TRAP_FATAL_TIMEOUT
>        Arg3: 0000000000000006, TimeoutCode: Timeout_PCE_Disable_Action -
> PortData->PortChangeListDone - Timeout trying to set Disable bit
>        Arg4: fffffa8003434000, TimeoutContext - PortData
>
>    Also, if I give the DomU more than about 3GB of memory, windows
> fails to boot with the non ACPI compliant BIOS BSOD. Also, windows
> installer doesn't get past the "Starting Windows" part, the pulsating
> logo also never appears.
>
>    I'm basically learning what every part of the code I'm messing
> with does as I go on, but this is really way too complex for one
> person to go through in a reasonable timeframe. So most of the changes
> I've made are pretty bruteforce-y. I'd really appreciate someone
> giving me a hand in this.
>
>    Also attached are dmesg and qemu logs.
>
> Thanks
>

[-- Attachment #2: messages.cat.log --]
[-- Type: application/octet-stream, Size: 40069 bytes --]

May 24 20:17:07 localhost kernel: [  216.814146]  [<ffffffff81280eb1>] ? xenbus_dev_changed+0x1c1/0x1d0
May 24 20:17:07 localhost kernel: [  216.814149]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:17:07 localhost kernel: [  216.814151]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:17:07 localhost kernel: [  216.814154]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:17:07 localhost kernel: [  216.814156]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:17:07 localhost kernel: [  216.814158]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:17:07 localhost kernel: [  216.814161]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:17:07 localhost kernel: [  216.814163]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:17:07 localhost kernel: [  216.814166]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:19:37 localhost kernel: [  367.458379] Registering the dns_resolver key type
May 24 20:27:51 localhost kernel: [  861.453109] Modules linked in: nls_utf8 cifs xt_physdev tun iptable_filter ip_tables x_tables parport_pc ppdev lp parport bluetooth rfkill cpufreq_userspace cpufreq_powersave cpufreq_stats cpufreq_conservative binfmt_misc fuse nfsd exportfs nfs lockd fscache nfs_acl auth_rpcgss sunrpc bridge stp ext3 jbd loop firewire_sbp2 i2c_i801 shpchp pci_hotplug tpm_tis tpm i2c_core psmouse evdev serio_raw pcspkr tpm_bios processor wmi button acpi_processor ext4 mbcache jbd2 crc16 dm_mod sg sr_mod pata_marvell ata_generic sd_mod crc_t10dif cdrom pata_jmicron firewire_ohci mvsas firewire_core libsas ahci scsi_transport_sas libata crc_itu_t sky2 scsi_mod thermal thermal_sys [last unloaded: scsi_wait_scan]
May 24 20:27:51 localhost kernel: [  861.453262] Pid: 40, comm: xenwatch Not tainted 2.6.32.39-temp #2
May 24 20:27:51 localhost kernel: [  861.453267] Call Trace:
May 24 20:27:51 localhost kernel: [  861.453279]  [<ffffffff81051240>] ? __schedule_bug+0x40/0x60
May 24 20:27:51 localhost kernel: [  861.453288]  [<ffffffff813e2f1a>] ? thread_return+0x716/0x7cc
May 24 20:27:51 localhost kernel: [  861.453297]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:27:51 localhost kernel: [  861.453305]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:27:51 localhost kernel: [  861.453313]  [<ffffffff8127eb85>] ? read_reply+0xa5/0x150
May 24 20:27:51 localhost kernel: [  861.453321]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:27:51 localhost kernel: [  861.453329]  [<ffffffff8127edfb>] ? xs_talkv+0xdb/0x1e0
May 24 20:27:51 localhost kernel: [  861.453336]  [<ffffffff8127f281>] ? unregister_xenbus_watch+0x101/0x240
May 24 20:27:51 localhost kernel: [  861.453344]  [<ffffffff81286819>] ? pciback_xenbus_remove+0x79/0x80
May 24 20:27:51 localhost kernel: [  861.453351]  [<ffffffff81280668>] ? xenbus_dev_remove+0x48/0x70
May 24 20:27:51 localhost kernel: [  861.453360]  [<ffffffff812cd369>] ? __device_release_driver+0x69/0xe0
May 24 20:27:51 localhost kernel: [  861.453367]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:27:51 localhost kernel: [  861.453375]  [<ffffffff812cd4b5>] ? device_release_driver+0x25/0x40
May 24 20:27:51 localhost kernel: [  861.453382]  [<ffffffff812cc591>] ? bus_remove_device+0x91/0xc0
May 24 20:27:51 localhost kernel: [  861.453389]  [<ffffffff812ca768>] ? device_del+0x118/0x1c0
May 24 20:27:51 localhost kernel: [  861.453396]  [<ffffffff812ca819>] ? device_unregister+0x9/0x20
May 24 20:27:51 localhost kernel: [  861.453402]  [<ffffffff81280d8e>] ? xenbus_dev_changed+0x9e/0x1d0
May 24 20:27:51 localhost kernel: [  861.453410]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:27:51 localhost kernel: [  861.453417]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:27:51 localhost kernel: [  861.453424]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:27:51 localhost kernel: [  861.453431]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:27:51 localhost kernel: [  861.453437]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:27:51 localhost kernel: [  861.453445]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:27:51 localhost kernel: [  861.453452]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:27:51 localhost kernel: [  861.453459]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:27:51 localhost kernel: [  861.453466]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:27:51 localhost kernel: [  861.499976] xenbr0: port 2(vif1.0) entering disabled state
May 24 20:27:51 localhost kernel: [  861.522358] xenbr0: port 2(vif1.0) entering disabled state
May 24 20:27:52 localhost kernel: [  862.269591] xenbr0: port 3(tap1.0) entering disabled state
May 24 20:27:52 localhost kernel: [  862.294017] xenbr0: port 3(tap1.0) entering disabled state
May 24 20:27:54 localhost kernel: [  864.267076] device vif2.0 entered promiscuous mode
May 24 20:27:54 localhost kernel: [  864.274943] xenbr0: port 2(vif2.0) entering forwarding state
May 24 20:27:55 localhost kernel: [  864.557449] device tap2.0 entered promiscuous mode
May 24 20:27:55 localhost kernel: [  864.565764] xenbr0: port 3(tap2.0) entering forwarding state
May 24 20:27:55 localhost kernel: [  864.761088] Modules linked in: nls_utf8 cifs xt_physdev tun iptable_filter ip_tables x_tables parport_pc ppdev lp parport bluetooth rfkill cpufreq_userspace cpufreq_powersave cpufreq_stats cpufreq_conservative binfmt_misc fuse nfsd exportfs nfs lockd fscache nfs_acl auth_rpcgss sunrpc bridge stp ext3 jbd loop firewire_sbp2 i2c_i801 shpchp pci_hotplug tpm_tis tpm i2c_core psmouse evdev serio_raw pcspkr tpm_bios processor wmi button acpi_processor ext4 mbcache jbd2 crc16 dm_mod sg sr_mod pata_marvell ata_generic sd_mod crc_t10dif cdrom pata_jmicron firewire_ohci mvsas firewire_core libsas ahci scsi_transport_sas libata crc_itu_t sky2 scsi_mod thermal thermal_sys [last unloaded: scsi_wait_scan]
May 24 20:27:55 localhost kernel: [  864.761175] Pid: 40, comm: xenwatch Not tainted 2.6.32.39-temp #2
May 24 20:27:55 localhost kernel: [  864.761177] Call Trace:
May 24 20:27:55 localhost kernel: [  864.761183]  [<ffffffff81051240>] ? __schedule_bug+0x40/0x60
May 24 20:27:55 localhost kernel: [  864.761187]  [<ffffffff813e2f1a>] ? thread_return+0x716/0x7cc
May 24 20:27:55 localhost kernel: [  864.761191]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:27:55 localhost kernel: [  864.761194]  [<ffffffff8100c6ad>] ? xen_mc_flush+0xad/0x1e0
May 24 20:27:55 localhost kernel: [  864.761197]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:27:55 localhost kernel: [  864.761199]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:27:55 localhost kernel: [  864.761203]  [<ffffffff8127eb85>] ? read_reply+0xa5/0x150
May 24 20:27:55 localhost kernel: [  864.761206]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:27:55 localhost kernel: [  864.761210]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.761212]  [<ffffffff8127edfb>] ? xs_talkv+0xdb/0x1e0
May 24 20:27:55 localhost kernel: [  864.761215]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.761218]  [<ffffffff8127f052>] ? xs_single+0x42/0x60
May 24 20:27:55 localhost kernel: [  864.761220]  [<ffffffff8127f6df>] ? xenbus_read+0x3f/0x70
May 24 20:27:55 localhost kernel: [  864.761222]  [<ffffffff8127f8aa>] ? xenbus_scanf+0x1a/0x70
May 24 20:27:55 localhost kernel: [  864.761225]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:27:55 localhost kernel: [  864.761228]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:27:55 localhost kernel: [  864.761231]  [<ffffffff81286b7c>] ? pciback_publish_pci_root+0x4c/0x1d0
May 24 20:27:55 localhost kernel: [  864.761233]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:27:55 localhost kernel: [  864.761236]  [<ffffffff8112710c>] ? kfree+0xbc/0x170
May 24 20:27:55 localhost kernel: [  864.761239]  [<ffffffff8127faa3>] ? xenbus_printf+0xd3/0x190
May 24 20:27:55 localhost kernel: [  864.761242]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.761247]  [<ffffffff812896d8>] ? pciback_publish_pci_roots+0x88/0xc0
May 24 20:27:55 localhost kernel: [  864.761250]  [<ffffffff8128706c>] ? pciback_setup_backend+0x24c/0x310
May 24 20:27:55 localhost kernel: [  864.761253]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:27:55 localhost kernel: [  864.761255]  [<ffffffff8127f7f3>] ? xenbus_gather+0xe3/0x180
May 24 20:27:55 localhost kernel: [  864.761258]  [<ffffffff8128777e>] ? pciback_xenbus_probe+0x13e/0x1c0
May 24 20:27:55 localhost kernel: [  864.761260]  [<ffffffff812807ac>] ? xenbus_dev_probe+0x7c/0x150
May 24 20:27:55 localhost kernel: [  864.761264]  [<ffffffff812cd673>] ? driver_probe_device+0x93/0x190
May 24 20:27:55 localhost kernel: [  864.761266]  [<ffffffff812cd810>] ? __device_attach+0x0/0x60
May 24 20:27:55 localhost kernel: [  864.761269]  [<ffffffff812cc7cc>] ? bus_for_each_drv+0x5c/0x90
May 24 20:27:55 localhost kernel: [  864.761271]  [<ffffffff812cd92c>] ? device_attach+0x8c/0xa0
May 24 20:27:55 localhost kernel: [  864.761274]  [<ffffffff812cc5e5>] ? bus_probe_device+0x25/0x40
May 24 20:27:55 localhost kernel: [  864.761276]  [<ffffffff812cafba>] ? device_add+0x51a/0x600
May 24 20:27:55 localhost kernel: [  864.761279]  [<ffffffff81280c44>] ? xenbus_probe_node+0x144/0x1f0
May 24 20:27:55 localhost kernel: [  864.761281]  [<ffffffff81280eb1>] ? xenbus_dev_changed+0x1c1/0x1d0
May 24 20:27:55 localhost kernel: [  864.761284]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:27:55 localhost kernel: [  864.761286]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:27:55 localhost kernel: [  864.761288]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:27:55 localhost kernel: [  864.761290]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:27:55 localhost kernel: [  864.761294]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:27:55 localhost kernel: [  864.761297]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:27:55 localhost kernel: [  864.761299]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:27:55 localhost kernel: [  864.761302]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:27:55 localhost kernel: [  864.761783] Modules linked in: nls_utf8 cifs xt_physdev tun iptable_filter ip_tables x_tables parport_pc ppdev lp parport bluetooth rfkill cpufreq_userspace cpufreq_powersave cpufreq_stats cpufreq_conservative binfmt_misc fuse nfsd exportfs nfs lockd fscache nfs_acl auth_rpcgss sunrpc bridge stp ext3 jbd loop firewire_sbp2 i2c_i801 shpchp pci_hotplug tpm_tis tpm i2c_core psmouse evdev serio_raw pcspkr tpm_bios processor wmi button acpi_processor ext4 mbcache jbd2 crc16 dm_mod sg sr_mod pata_marvell ata_generic sd_mod crc_t10dif cdrom pata_jmicron firewire_ohci mvsas firewire_core libsas ahci scsi_transport_sas libata crc_itu_t sky2 scsi_mod thermal thermal_sys [last unloaded: scsi_wait_scan]
May 24 20:27:55 localhost kernel: [  864.761878] Pid: 40, comm: xenwatch Not tainted 2.6.32.39-temp #2
May 24 20:27:55 localhost kernel: [  864.761880] Call Trace:
May 24 20:27:55 localhost kernel: [  864.761883]  [<ffffffff81051240>] ? __schedule_bug+0x40/0x60
May 24 20:27:55 localhost kernel: [  864.761886]  [<ffffffff813e2f1a>] ? thread_return+0x716/0x7cc
May 24 20:27:55 localhost kernel: [  864.761889]  [<ffffffff8120a4ca>] ? string+0x3a/0xf0
May 24 20:27:55 localhost kernel: [  864.761893]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:27:55 localhost kernel: [  864.761896]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:27:55 localhost kernel: [  864.761899]  [<ffffffff8127eb85>] ? read_reply+0xa5/0x150
May 24 20:27:55 localhost kernel: [  864.761902]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:27:55 localhost kernel: [  864.761904]  [<ffffffff8127edfb>] ? xs_talkv+0xdb/0x1e0
May 24 20:27:55 localhost kernel: [  864.761907]  [<ffffffff8127f66b>] ? xenbus_write+0x6b/0xa0
May 24 20:27:55 localhost kernel: [  864.761909]  [<ffffffff8127fa98>] ? xenbus_printf+0xc8/0x190
May 24 20:27:55 localhost kernel: [  864.761912]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.761915]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.761917]  [<ffffffff8120ba06>] ? snprintf+0x36/0x40
May 24 20:27:55 localhost kernel: [  864.761920]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:27:55 localhost kernel: [  864.761923]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.761926]  [<ffffffff81286bdb>] ? pciback_publish_pci_root+0xab/0x1d0
May 24 20:27:55 localhost kernel: [  864.761928]  [<ffffffff8112710c>] ? kfree+0xbc/0x170
May 24 20:27:55 localhost kernel: [  864.761931]  [<ffffffff8127faa3>] ? xenbus_printf+0xd3/0x190
May 24 20:27:55 localhost kernel: [  864.761933]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.761936]  [<ffffffff812896d8>] ? pciback_publish_pci_roots+0x88/0xc0
May 24 20:27:55 localhost kernel: [  864.761939]  [<ffffffff8128706c>] ? pciback_setup_backend+0x24c/0x310
May 24 20:27:55 localhost kernel: [  864.761942]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:27:55 localhost kernel: [  864.761945]  [<ffffffff8127f7f3>] ? xenbus_gather+0xe3/0x180
May 24 20:27:55 localhost kernel: [  864.761948]  [<ffffffff8128777e>] ? pciback_xenbus_probe+0x13e/0x1c0
May 24 20:27:55 localhost kernel: [  864.761950]  [<ffffffff812807ac>] ? xenbus_dev_probe+0x7c/0x150
May 24 20:27:55 localhost kernel: [  864.761953]  [<ffffffff812cd673>] ? driver_probe_device+0x93/0x190
May 24 20:27:55 localhost kernel: [  864.761956]  [<ffffffff812cd810>] ? __device_attach+0x0/0x60
May 24 20:27:55 localhost kernel: [  864.761958]  [<ffffffff812cc7cc>] ? bus_for_each_drv+0x5c/0x90
May 24 20:27:55 localhost kernel: [  864.761961]  [<ffffffff812cd92c>] ? device_attach+0x8c/0xa0
May 24 20:27:55 localhost kernel: [  864.761963]  [<ffffffff812cc5e5>] ? bus_probe_device+0x25/0x40
May 24 20:27:55 localhost kernel: [  864.761966]  [<ffffffff812cafba>] ? device_add+0x51a/0x600
May 24 20:27:55 localhost kernel: [  864.761968]  [<ffffffff81280c44>] ? xenbus_probe_node+0x144/0x1f0
May 24 20:27:55 localhost kernel: [  864.761971]  [<ffffffff81280eb1>] ? xenbus_dev_changed+0x1c1/0x1d0
May 24 20:27:55 localhost kernel: [  864.761974]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:27:55 localhost kernel: [  864.761976]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:27:55 localhost kernel: [  864.761979]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:27:55 localhost kernel: [  864.761981]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:27:55 localhost kernel: [  864.761984]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:27:55 localhost kernel: [  864.761987]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:27:55 localhost kernel: [  864.761990]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:27:55 localhost kernel: [  864.761992]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:27:55 localhost kernel: [  864.762621] Modules linked in: nls_utf8 cifs xt_physdev tun iptable_filter ip_tables x_tables parport_pc ppdev lp parport bluetooth rfkill cpufreq_userspace cpufreq_powersave cpufreq_stats cpufreq_conservative binfmt_misc fuse nfsd exportfs nfs lockd fscache nfs_acl auth_rpcgss sunrpc bridge stp ext3 jbd loop firewire_sbp2 i2c_i801 shpchp pci_hotplug tpm_tis tpm i2c_core psmouse evdev serio_raw pcspkr tpm_bios processor wmi button acpi_processor ext4 mbcache jbd2 crc16 dm_mod sg sr_mod pata_marvell ata_generic sd_mod crc_t10dif cdrom pata_jmicron firewire_ohci mvsas firewire_core libsas ahci scsi_transport_sas libata crc_itu_t sky2 scsi_mod thermal thermal_sys [last unloaded: scsi_wait_scan]
May 24 20:27:55 localhost kernel: [  864.762674] Pid: 40, comm: xenwatch Not tainted 2.6.32.39-temp #2
May 24 20:27:55 localhost kernel: [  864.762675] Call Trace:
May 24 20:27:55 localhost kernel: [  864.762679]  [<ffffffff81051240>] ? __schedule_bug+0x40/0x60
May 24 20:27:55 localhost kernel: [  864.762682]  [<ffffffff813e2f1a>] ? thread_return+0x716/0x7cc
May 24 20:27:55 localhost kernel: [  864.762684]  [<ffffffff8120a4ca>] ? string+0x3a/0xf0
May 24 20:27:55 localhost kernel: [  864.762687]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:27:55 localhost kernel: [  864.762690]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:27:55 localhost kernel: [  864.762693]  [<ffffffff8127eb85>] ? read_reply+0xa5/0x150
May 24 20:27:55 localhost kernel: [  864.762695]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:27:55 localhost kernel: [  864.762698]  [<ffffffff8127edfb>] ? xs_talkv+0xdb/0x1e0
May 24 20:27:55 localhost kernel: [  864.762701]  [<ffffffff8127f66b>] ? xenbus_write+0x6b/0xa0
May 24 20:27:55 localhost kernel: [  864.762703]  [<ffffffff8127fa98>] ? xenbus_printf+0xc8/0x190
May 24 20:27:55 localhost kernel: [  864.762706]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.762709]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.762712]  [<ffffffff8120ba06>] ? snprintf+0x36/0x40
May 24 20:27:55 localhost kernel: [  864.762715]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:27:55 localhost kernel: [  864.762718]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.762720]  [<ffffffff81286ce1>] ? pciback_publish_pci_root+0x1b1/0x1d0
May 24 20:27:55 localhost kernel: [  864.762723]  [<ffffffff8112710c>] ? kfree+0xbc/0x170
May 24 20:27:55 localhost kernel: [  864.762726]  [<ffffffff8127faa3>] ? xenbus_printf+0xd3/0x190
May 24 20:27:55 localhost kernel: [  864.762728]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:27:55 localhost kernel: [  864.762731]  [<ffffffff812896d8>] ? pciback_publish_pci_roots+0x88/0xc0
May 24 20:27:55 localhost kernel: [  864.762734]  [<ffffffff8128706c>] ? pciback_setup_backend+0x24c/0x310
May 24 20:27:55 localhost kernel: [  864.762737]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:27:55 localhost kernel: [  864.762740]  [<ffffffff8127f7f3>] ? xenbus_gather+0xe3/0x180
May 24 20:27:55 localhost kernel: [  864.762743]  [<ffffffff8128777e>] ? pciback_xenbus_probe+0x13e/0x1c0
May 24 20:27:55 localhost kernel: [  864.762745]  [<ffffffff812807ac>] ? xenbus_dev_probe+0x7c/0x150
May 24 20:27:55 localhost kernel: [  864.762748]  [<ffffffff812cd673>] ? driver_probe_device+0x93/0x190
May 24 20:27:55 localhost kernel: [  864.762751]  [<ffffffff812cd810>] ? __device_attach+0x0/0x60
May 24 20:27:55 localhost kernel: [  864.762753]  [<ffffffff812cc7cc>] ? bus_for_each_drv+0x5c/0x90
May 24 20:27:55 localhost kernel: [  864.762756]  [<ffffffff812cd92c>] ? device_attach+0x8c/0xa0
May 24 20:27:55 localhost kernel: [  864.762758]  [<ffffffff812cc5e5>] ? bus_probe_device+0x25/0x40
May 24 20:27:55 localhost kernel: [  864.762761]  [<ffffffff812cafba>] ? device_add+0x51a/0x600
May 24 20:27:55 localhost kernel: [  864.762764]  [<ffffffff81280c44>] ? xenbus_probe_node+0x144/0x1f0
May 24 20:27:55 localhost kernel: [  864.762767]  [<ffffffff81280eb1>] ? xenbus_dev_changed+0x1c1/0x1d0
May 24 20:27:55 localhost kernel: [  864.762769]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:27:55 localhost kernel: [  864.762772]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:27:55 localhost kernel: [  864.762774]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:27:55 localhost kernel: [  864.762777]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:27:55 localhost kernel: [  864.762780]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:27:55 localhost kernel: [  864.762782]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:27:55 localhost kernel: [  864.762784]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:27:55 localhost kernel: [  864.762787]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:29:05 localhost kernel: [  935.224515] Modules linked in: nls_utf8 cifs xt_physdev tun iptable_filter ip_tables x_tables parport_pc ppdev lp parport bluetooth rfkill cpufreq_userspace cpufreq_powersave cpufreq_stats cpufreq_conservative binfmt_misc fuse nfsd exportfs nfs lockd fscache nfs_acl auth_rpcgss sunrpc bridge stp ext3 jbd loop firewire_sbp2 i2c_i801 shpchp pci_hotplug tpm_tis tpm i2c_core psmouse evdev serio_raw pcspkr tpm_bios processor wmi button acpi_processor ext4 mbcache jbd2 crc16 dm_mod sg sr_mod pata_marvell ata_generic sd_mod crc_t10dif cdrom pata_jmicron firewire_ohci mvsas firewire_core libsas ahci scsi_transport_sas libata crc_itu_t sky2 scsi_mod thermal thermal_sys [last unloaded: scsi_wait_scan]
May 24 20:29:05 localhost kernel: [  935.224570] Pid: 40, comm: xenwatch Not tainted 2.6.32.39-temp #2
May 24 20:29:05 localhost kernel: [  935.224572] Call Trace:
May 24 20:29:05 localhost kernel: [  935.224578]  [<ffffffff81051240>] ? __schedule_bug+0x40/0x60
May 24 20:29:05 localhost kernel: [  935.224581]  [<ffffffff813e2f1a>] ? thread_return+0x716/0x7cc
May 24 20:29:05 localhost kernel: [  935.224585]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:29:05 localhost kernel: [  935.224588]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:29:05 localhost kernel: [  935.224591]  [<ffffffff8127eb85>] ? read_reply+0xa5/0x150
May 24 20:29:05 localhost kernel: [  935.224595]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:29:05 localhost kernel: [  935.224597]  [<ffffffff8127edfb>] ? xs_talkv+0xdb/0x1e0
May 24 20:29:05 localhost kernel: [  935.224600]  [<ffffffff8127f281>] ? unregister_xenbus_watch+0x101/0x240
May 24 20:29:05 localhost kernel: [  935.224603]  [<ffffffff81286819>] ? pciback_xenbus_remove+0x79/0x80
May 24 20:29:05 localhost kernel: [  935.224605]  [<ffffffff81280668>] ? xenbus_dev_remove+0x48/0x70
May 24 20:29:05 localhost kernel: [  935.224609]  [<ffffffff812cd369>] ? __device_release_driver+0x69/0xe0
May 24 20:29:05 localhost kernel: [  935.224611]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:29:05 localhost kernel: [  935.224614]  [<ffffffff812cd4b5>] ? device_release_driver+0x25/0x40
May 24 20:29:05 localhost kernel: [  935.224616]  [<ffffffff812cc591>] ? bus_remove_device+0x91/0xc0
May 24 20:29:05 localhost kernel: [  935.224619]  [<ffffffff812ca768>] ? device_del+0x118/0x1c0
May 24 20:29:05 localhost kernel: [  935.224621]  [<ffffffff812ca819>] ? device_unregister+0x9/0x20
May 24 20:29:05 localhost kernel: [  935.224623]  [<ffffffff81280d8e>] ? xenbus_dev_changed+0x9e/0x1d0
May 24 20:29:05 localhost kernel: [  935.224626]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:29:05 localhost kernel: [  935.224628]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:29:05 localhost kernel: [  935.224630]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:29:05 localhost kernel: [  935.224633]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:29:05 localhost kernel: [  935.224635]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:29:05 localhost kernel: [  935.224638]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:29:05 localhost kernel: [  935.224641]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:29:05 localhost kernel: [  935.224643]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:29:05 localhost kernel: [  935.224645]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:29:05 localhost kernel: [  935.247685] xenbr0: port 2(vif2.0) entering disabled state
May 24 20:29:05 localhost kernel: [  935.266290] xenbr0: port 2(vif2.0) entering disabled state
May 24 20:29:06 localhost kernel: [  935.796485] xenbr0: port 3(tap2.0) entering disabled state
May 24 20:29:06 localhost kernel: [  935.820594] xenbr0: port 3(tap2.0) entering disabled state
May 24 20:29:08 localhost kernel: [  937.957796] device tap3.0 entered promiscuous mode
May 24 20:29:08 localhost kernel: [  937.959367] device vif3.0 entered promiscuous mode
May 24 20:29:08 localhost kernel: [  937.963581] Modules linked in: nls_utf8 cifs xt_physdev tun iptable_filter ip_tables x_tables parport_pc ppdev lp parport bluetooth rfkill cpufreq_userspace cpufreq_powersave cpufreq_stats cpufreq_conservative binfmt_misc fuse nfsd exportfs nfs lockd fscache nfs_acl auth_rpcgss sunrpc bridge stp ext3 jbd loop firewire_sbp2 i2c_i801 shpchp pci_hotplug tpm_tis tpm i2c_core psmouse evdev serio_raw pcspkr tpm_bios processor wmi button acpi_processor ext4 mbcache jbd2 crc16 dm_mod sg sr_mod pata_marvell ata_generic sd_mod crc_t10dif cdrom pata_jmicron firewire_ohci mvsas firewire_core libsas ahci scsi_transport_sas libata crc_itu_t sky2 scsi_mod thermal thermal_sys [last unloaded: scsi_wait_scan]
May 24 20:29:08 localhost kernel: [  937.963677] Pid: 40, comm: xenwatch Not tainted 2.6.32.39-temp #2
May 24 20:29:08 localhost kernel: [  937.963680] Call Trace:
May 24 20:29:08 localhost kernel: [  937.963686]  [<ffffffff81051240>] ? __schedule_bug+0x40/0x60
May 24 20:29:08 localhost kernel: [  937.963691]  [<ffffffff813e2f1a>] ? thread_return+0x716/0x7cc
May 24 20:29:08 localhost kernel: [  937.963695]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:29:08 localhost kernel: [  937.963698]  [<ffffffff8100c6ad>] ? xen_mc_flush+0xad/0x1e0
May 24 20:29:08 localhost kernel: [  937.963701]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:29:08 localhost kernel: [  937.963704]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:29:08 localhost kernel: [  937.963708]  [<ffffffff8127eb85>] ? read_reply+0xa5/0x150
May 24 20:29:08 localhost kernel: [  937.963712]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:29:08 localhost kernel: [  937.963716]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.963719]  [<ffffffff8127edfb>] ? xs_talkv+0xdb/0x1e0
May 24 20:29:08 localhost kernel: [  937.963722]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.963725]  [<ffffffff8127f052>] ? xs_single+0x42/0x60
May 24 20:29:08 localhost kernel: [  937.963727]  [<ffffffff8127f6df>] ? xenbus_read+0x3f/0x70
May 24 20:29:08 localhost kernel: [  937.963730]  [<ffffffff8127f8aa>] ? xenbus_scanf+0x1a/0x70
May 24 20:29:08 localhost kernel: [  937.963733]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:29:08 localhost kernel: [  937.963736]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:29:08 localhost kernel: [  937.963740]  [<ffffffff81286b7c>] ? pciback_publish_pci_root+0x4c/0x1d0
May 24 20:29:08 localhost kernel: [  937.963743]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:29:08 localhost kernel: [  937.963747]  [<ffffffff8112710c>] ? kfree+0xbc/0x170
May 24 20:29:08 localhost kernel: [  937.963749]  [<ffffffff8127faa3>] ? xenbus_printf+0xd3/0x190
May 24 20:29:08 localhost kernel: [  937.963753]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.963756]  [<ffffffff812896d8>] ? pciback_publish_pci_roots+0x88/0xc0
May 24 20:29:08 localhost kernel: [  937.963759]  [<ffffffff8128706c>] ? pciback_setup_backend+0x24c/0x310
May 24 20:29:08 localhost kernel: [  937.963763]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:29:08 localhost kernel: [  937.963765]  [<ffffffff8127f7f3>] ? xenbus_gather+0xe3/0x180
May 24 20:29:08 localhost kernel: [  937.963769]  [<ffffffff8128777e>] ? pciback_xenbus_probe+0x13e/0x1c0
May 24 20:29:08 localhost kernel: [  937.963772]  [<ffffffff812807ac>] ? xenbus_dev_probe+0x7c/0x150
May 24 20:29:08 localhost kernel: [  937.963776]  [<ffffffff812cd673>] ? driver_probe_device+0x93/0x190
May 24 20:29:08 localhost kernel: [  937.963779]  [<ffffffff812cd810>] ? __device_attach+0x0/0x60
May 24 20:29:08 localhost kernel: [  937.963782]  [<ffffffff812cc7cc>] ? bus_for_each_drv+0x5c/0x90
May 24 20:29:08 localhost kernel: [  937.963785]  [<ffffffff812cd92c>] ? device_attach+0x8c/0xa0
May 24 20:29:08 localhost kernel: [  937.963788]  [<ffffffff812cc5e5>] ? bus_probe_device+0x25/0x40
May 24 20:29:08 localhost kernel: [  937.963791]  [<ffffffff812cafba>] ? device_add+0x51a/0x600
May 24 20:29:08 localhost kernel: [  937.963794]  [<ffffffff81280c44>] ? xenbus_probe_node+0x144/0x1f0
May 24 20:29:08 localhost kernel: [  937.963797]  [<ffffffff81280eb1>] ? xenbus_dev_changed+0x1c1/0x1d0
May 24 20:29:08 localhost kernel: [  937.963800]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:29:08 localhost kernel: [  937.963803]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:29:08 localhost kernel: [  937.963806]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:29:08 localhost kernel: [  937.963810]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:29:08 localhost kernel: [  937.963814]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:29:08 localhost kernel: [  937.963817]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:29:08 localhost kernel: [  937.963820]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:29:08 localhost kernel: [  937.963823]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:29:08 localhost kernel: [  937.963876] Modules linked in: nls_utf8 cifs xt_physdev tun iptable_filter ip_tables x_tables parport_pc ppdev lp parport bluetooth rfkill cpufreq_userspace cpufreq_powersave cpufreq_stats cpufreq_conservative binfmt_misc fuse nfsd exportfs nfs lockd fscache nfs_acl auth_rpcgss sunrpc bridge stp ext3 jbd loop firewire_sbp2 i2c_i801 shpchp pci_hotplug tpm_tis tpm i2c_core psmouse evdev serio_raw pcspkr tpm_bios processor wmi button acpi_processor ext4 mbcache jbd2 crc16 dm_mod sg sr_mod pata_marvell ata_generic sd_mod crc_t10dif cdrom pata_jmicron firewire_ohci mvsas firewire_core libsas ahci scsi_transport_sas libata crc_itu_t sky2 scsi_mod thermal thermal_sys [last unloaded: scsi_wait_scan]
May 24 20:29:08 localhost kernel: [  937.963938] Pid: 40, comm: xenwatch Not tainted 2.6.32.39-temp #2
May 24 20:29:08 localhost kernel: [  937.963940] Call Trace:
May 24 20:29:08 localhost kernel: [  937.963943]  [<ffffffff81051240>] ? __schedule_bug+0x40/0x60
May 24 20:29:08 localhost kernel: [  937.963946]  [<ffffffff813e2f1a>] ? thread_return+0x716/0x7cc
May 24 20:29:08 localhost kernel: [  937.963949]  [<ffffffff8120a4ca>] ? string+0x3a/0xf0
May 24 20:29:08 localhost kernel: [  937.963952]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:29:08 localhost kernel: [  937.963955]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:29:08 localhost kernel: [  937.963958]  [<ffffffff8127eb85>] ? read_reply+0xa5/0x150
May 24 20:29:08 localhost kernel: [  937.963960]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:29:08 localhost kernel: [  937.963963]  [<ffffffff8127edfb>] ? xs_talkv+0xdb/0x1e0
May 24 20:29:08 localhost kernel: [  937.963966]  [<ffffffff8127f66b>] ? xenbus_write+0x6b/0xa0
May 24 20:29:08 localhost kernel: [  937.963969]  [<ffffffff8127fa98>] ? xenbus_printf+0xc8/0x190
May 24 20:29:08 localhost kernel: [  937.963972]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.963975]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.963978]  [<ffffffff8120ba06>] ? snprintf+0x36/0x40
May 24 20:29:08 localhost kernel: [  937.963981]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:29:08 localhost kernel: [  937.963984]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.963987]  [<ffffffff81286bdb>] ? pciback_publish_pci_root+0xab/0x1d0
May 24 20:29:08 localhost kernel: [  937.963990]  [<ffffffff8112710c>] ? kfree+0xbc/0x170
May 24 20:29:08 localhost kernel: [  937.963993]  [<ffffffff8127faa3>] ? xenbus_printf+0xd3/0x190
May 24 20:29:08 localhost kernel: [  937.963996]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.963999]  [<ffffffff812896d8>] ? pciback_publish_pci_roots+0x88/0xc0
May 24 20:29:08 localhost kernel: [  937.964002]  [<ffffffff8128706c>] ? pciback_setup_backend+0x24c/0x310
May 24 20:29:08 localhost kernel: [  937.964006]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:29:08 localhost kernel: [  937.964009]  [<ffffffff8127f7f3>] ? xenbus_gather+0xe3/0x180
May 24 20:29:08 localhost kernel: [  937.964012]  [<ffffffff8128777e>] ? pciback_xenbus_probe+0x13e/0x1c0
May 24 20:29:08 localhost kernel: [  937.964014]  [<ffffffff812807ac>] ? xenbus_dev_probe+0x7c/0x150
May 24 20:29:08 localhost kernel: [  937.964017]  [<ffffffff812cd673>] ? driver_probe_device+0x93/0x190
May 24 20:29:08 localhost kernel: [  937.964020]  [<ffffffff812cd810>] ? __device_attach+0x0/0x60
May 24 20:29:08 localhost kernel: [  937.964023]  [<ffffffff812cc7cc>] ? bus_for_each_drv+0x5c/0x90
May 24 20:29:08 localhost kernel: [  937.964026]  [<ffffffff812cd92c>] ? device_attach+0x8c/0xa0
May 24 20:29:08 localhost kernel: [  937.964029]  [<ffffffff812cc5e5>] ? bus_probe_device+0x25/0x40
May 24 20:29:08 localhost kernel: [  937.964031]  [<ffffffff812cafba>] ? device_add+0x51a/0x600
May 24 20:29:08 localhost kernel: [  937.964034]  [<ffffffff81280c44>] ? xenbus_probe_node+0x144/0x1f0
May 24 20:29:08 localhost kernel: [  937.964037]  [<ffffffff81280eb1>] ? xenbus_dev_changed+0x1c1/0x1d0
May 24 20:29:08 localhost kernel: [  937.964040]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:29:08 localhost kernel: [  937.964042]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:29:08 localhost kernel: [  937.964045]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:29:08 localhost kernel: [  937.964047]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:29:08 localhost kernel: [  937.964050]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:29:08 localhost kernel: [  937.964053]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:29:08 localhost kernel: [  937.964056]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:29:08 localhost kernel: [  937.964059]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:29:08 localhost kernel: [  937.964550] Modules linked in: nls_utf8 cifs xt_physdev tun iptable_filter ip_tables x_tables parport_pc ppdev lp parport bluetooth rfkill cpufreq_userspace cpufreq_powersave cpufreq_stats cpufreq_conservative binfmt_misc fuse nfsd exportfs nfs lockd fscache nfs_acl auth_rpcgss sunrpc bridge stp ext3 jbd loop firewire_sbp2 i2c_i801 shpchp pci_hotplug tpm_tis tpm i2c_core psmouse evdev serio_raw pcspkr tpm_bios processor wmi button acpi_processor ext4 mbcache jbd2 crc16 dm_mod sg sr_mod pata_marvell ata_generic sd_mod crc_t10dif cdrom pata_jmicron firewire_ohci mvsas firewire_core libsas ahci scsi_transport_sas libata crc_itu_t sky2 scsi_mod thermal thermal_sys [last unloaded: scsi_wait_scan]
May 24 20:29:08 localhost kernel: [  937.964630] Pid: 40, comm: xenwatch Not tainted 2.6.32.39-temp #2
May 24 20:29:08 localhost kernel: [  937.964632] Call Trace:
May 24 20:29:08 localhost kernel: [  937.964635]  [<ffffffff81051240>] ? __schedule_bug+0x40/0x60
May 24 20:29:08 localhost kernel: [  937.964638]  [<ffffffff813e2f1a>] ? thread_return+0x716/0x7cc
May 24 20:29:08 localhost kernel: [  937.964641]  [<ffffffff8120a4ca>] ? string+0x3a/0xf0
May 24 20:29:08 localhost kernel: [  937.964644]  [<ffffffff8100fea9>] ? xen_force_evtchn_callback+0x9/0x10
May 24 20:29:08 localhost kernel: [  937.964647]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:29:08 localhost kernel: [  937.964650]  [<ffffffff8127eb85>] ? read_reply+0xa5/0x150
May 24 20:29:08 localhost kernel: [  937.964653]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:29:08 localhost kernel: [  937.964656]  [<ffffffff8127edfb>] ? xs_talkv+0xdb/0x1e0
May 24 20:29:08 localhost kernel: [  937.964659]  [<ffffffff8127f66b>] ? xenbus_write+0x6b/0xa0
May 24 20:29:08 localhost kernel: [  937.964661]  [<ffffffff8127fa98>] ? xenbus_printf+0xc8/0x190
May 24 20:29:08 localhost kernel: [  937.964664]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.964667]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.964670]  [<ffffffff8120ba06>] ? snprintf+0x36/0x40
May 24 20:29:08 localhost kernel: [  937.964673]  [<ffffffff81010872>] ? check_events+0x12/0x20
May 24 20:29:08 localhost kernel: [  937.964676]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.964678]  [<ffffffff81286ce1>] ? pciback_publish_pci_root+0x1b1/0x1d0
May 24 20:29:08 localhost kernel: [  937.964681]  [<ffffffff8112710c>] ? kfree+0xbc/0x170
May 24 20:29:08 localhost kernel: [  937.964684]  [<ffffffff8127faa3>] ? xenbus_printf+0xd3/0x190
May 24 20:29:08 localhost kernel: [  937.964687]  [<ffffffff81286b30>] ? pciback_publish_pci_root+0x0/0x1d0
May 24 20:29:08 localhost kernel: [  937.964690]  [<ffffffff812896d8>] ? pciback_publish_pci_roots+0x88/0xc0
May 24 20:29:08 localhost kernel: [  937.964693]  [<ffffffff8128706c>] ? pciback_setup_backend+0x24c/0x310
May 24 20:29:08 localhost kernel: [  937.964696]  [<ffffffff8101085f>] ? xen_restore_fl_direct_end+0x0/0x1
May 24 20:29:08 localhost kernel: [  937.964699]  [<ffffffff8127f7f3>] ? xenbus_gather+0xe3/0x180
May 24 20:29:08 localhost kernel: [  937.964702]  [<ffffffff8128777e>] ? pciback_xenbus_probe+0x13e/0x1c0
May 24 20:29:08 localhost kernel: [  937.964705]  [<ffffffff812807ac>] ? xenbus_dev_probe+0x7c/0x150
May 24 20:29:08 localhost kernel: [  937.964708]  [<ffffffff812cd673>] ? driver_probe_device+0x93/0x190
May 24 20:29:08 localhost kernel: [  937.964710]  [<ffffffff812cd810>] ? __device_attach+0x0/0x60
May 24 20:29:08 localhost kernel: [  937.964714]  [<ffffffff812cc7cc>] ? bus_for_each_drv+0x5c/0x90
May 24 20:29:08 localhost kernel: [  937.964717]  [<ffffffff812cd92c>] ? device_attach+0x8c/0xa0
May 24 20:29:08 localhost kernel: [  937.964720]  [<ffffffff812cc5e5>] ? bus_probe_device+0x25/0x40
May 24 20:29:08 localhost kernel: [  937.964723]  [<ffffffff812cafba>] ? device_add+0x51a/0x600
May 24 20:29:08 localhost kernel: [  937.964726]  [<ffffffff81280c44>] ? xenbus_probe_node+0x144/0x1f0
May 24 20:29:08 localhost kernel: [  937.964729]  [<ffffffff81280eb1>] ? xenbus_dev_changed+0x1c1/0x1d0
May 24 20:29:08 localhost kernel: [  937.964733]  [<ffffffff8127ea08>] ? xenwatch_thread+0xa8/0x180
May 24 20:29:08 localhost kernel: [  937.964736]  [<ffffffff8107f7b0>] ? autoremove_wake_function+0x0/0x30
May 24 20:29:08 localhost kernel: [  937.964739]  [<ffffffff8127e960>] ? xenwatch_thread+0x0/0x180
May 24 20:29:08 localhost kernel: [  937.964741]  [<ffffffff8107f3fe>] ? kthread+0x8e/0xa0
May 24 20:29:08 localhost kernel: [  937.964744]  [<ffffffff8101511a>] ? child_rip+0xa/0x20
May 24 20:29:08 localhost kernel: [  937.964747]  [<ffffffff810142a1>] ? int_ret_from_sys_call+0x7/0x1b
May 24 20:29:08 localhost kernel: [  937.964749]  [<ffffffff81014a61>] ? retint_restore_args+0x5/0x6
May 24 20:29:08 localhost kernel: [  937.964752]  [<ffffffff81015110>] ? child_rip+0x0/0x20
May 24 20:29:08 localhost kernel: [  937.965975] xenbr0: port 2(tap3.0) entering forwarding state
May 24 20:29:08 localhost kernel: [  937.968904] xenbr0: port 3(vif3.0) entering forwarding state

[-- Attachment #3: qemu-dm-W7Test.cat.log --]
[-- Type: application/octet-stream, Size: 863 bytes --]

pt_iomem_map: e_phys=ffffffff maddr=f2100000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=f1864000 maddr=fbb00000 type=0 len=16384 index=0 first_map=0
pt_ioport_map: e_phys=c200 pio_base=b800 len=256 index=2 first_map=0
pt_iomem_map: e_phys=f1860000 maddr=f2100000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c04000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=f186e000 maddr=a0c04000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c05000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c00000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=f186f000 maddr=a0c05000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=f1868000 maddr=a0c00000 type=0 len=16384 index=0 first_map=0
reset requested in cpu_handle_ioreq.
Issued domain 1 reboot

[-- Attachment #4: Type: text/plain, Size: 138 bytes --]

_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xensource.com
http://lists.xensource.com/xen-devel

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
@ 2011-05-24 15:35 Liwei
  2011-05-24 15:44 ` Liwei
  0 siblings, 1 reply; 21+ messages in thread
From: Liwei @ 2011-05-24 15:35 UTC (permalink / raw)
  To: xen-devel, xen-users; +Cc: Gennady Marchenko

[-- Attachment #1: Type: text/plain, Size: 3521 bytes --]

Hello all,
    I've made some progress after manually editing dsdt.asl to reserve
my card's memory ranges based on lspci, and fixing a bug in the
previous patch where a pair of braces were missing causing the wrong
video BIOS to be loaded. The fixed patch is attached. Do take note
that I've also removed the changes for secondary card passthrough.
    With those changes I am able to boot into Windows with the driver
installed (Fresh install with gfx_passthrough = 0). Logging in using
remote desktop, I can see that the driver is active. I also see that
screen spanning is active as I can move my mouse pointer between both
monitors. Everything looks good - until I tried to physically login.
    First two tries:
        The login screen disappears, leaving both screens black with
my cursor free to move around. After a few seconds, the whole system
(Dom0 + DomU) locks up. The reset button didn't work as normal;
usually pressing it will immediately reboot the PC, but this time it
had no response for a few seconds, then it shut down, and almost
immediately started again, returning back to normal. Weird.
        The logs from qemu and syslog didn't show anything special
happening before and up to the lockup. xl dmesg didn't throw up
anything interesting before the lockup either, though that was viewed
through a script that repeatedly calls xl dmesg over a ssh connection.

    After that, I tried to compare the memory ranges from Device
Manager to the ranges specified in dsdt.asl. Matches. But I also
noticed the original PCI memory reserve overlapped with the range of
the card. Not sure whether that was bad, but I pushed the range back
anyways and tried again.
    Third and subsequent tries:
        After logging in, but before the login screen disappears, the
DomU reboots. I didn't see any BSOD flash by but a minidump appears.
Analysing it gives me the following:
	VIDEO_TDR_FAILURE (116)
	Attempt to reset the display driver and recover from timeout failed.
	Arguments:
	Arg1: fffffa8003bdb010, Optional pointer to internal TDR recovery
context (TDR_RECOVERY_CONTEXT).
	Arg2: fffff8800f204520, The pointer into responsible device driver
module (e.g. owner tag).
	Arg3: 0000000000000000, Optional error code (NTSTATUS) of the last
failed operation.
	Arg4: 0000000000000002, Optional internal context dependent data.
        Also I noticed that if the display goes into suspend, it never
comes back. I'm still able to do stuff over remote desktop though.

    Sometimes I get the following minidump too, even in a remote
desktop session:
	BUGCODE_USB_DRIVER (fe)
	USB Driver bugcheck, first parameter is USB bugcheck code.
	Arguments:
	Arg1: 0000000000000008, USBBUGCODE_RESERVED_USBHUB
	Arg2: 0000000000000006, USBHUB_TRAP_FATAL_TIMEOUT
	Arg3: 0000000000000006, TimeoutCode: Timeout_PCE_Disable_Action -
PortData->PortChangeListDone - Timeout trying to set Disable bit
	Arg4: fffffa8003434000, TimeoutContext - PortData

    Also, if I give the DomU more than about 3GB of memory, windows
fails to boot with the non ACPI compliant BIOS BSOD. Also, windows
installer doesn't get past the "Starting Windows" part, the pulsating
logo also never appears.

    I'm basically learning what every part of the code I'm messing
with does as I go on, but this is really way too complex for one
person to go through in a reasonable timeframe. So most of the changes
I've made are pretty bruteforce-y. I'd really appreciate someone
giving me a hand in this.

    Also attached are dmesg and qemu logs.

Thanks

[-- Attachment #2: vga-pt-xen42-xieliwei-v3.patch --]
[-- Type: application/octet-stream, Size: 8575 bytes --]

--- tools/firmware/hvmloader/acpi/dsdt.asl.orig	2011-05-02 09:55:12.000000000 +0800
+++ tools/firmware/hvmloader/acpi/dsdt.asl	2011-05-24 20:41:17.667767180 +0800
@@ -158,42 +158,70 @@
                         ResourceProducer, MinFixed, MaxFixed, PosDecode,
                         EntireRange,
                         0x0000,
                         0x0D00,
                         0xFFFF,
                         0x0000,
                         0xF300)
 
                     /* reserve memory for pci devices */
                     DWordMemory(
                         ResourceProducer, PosDecode, MinFixed, MaxFixed,
                         Cacheable, ReadWrite,
                         0x00000000,
                         0x000A0000,
                         0x000BFFFF,
                         0x00000000,
                         0x00020000)
 
+                    /* reserve MMIO BARs of gfx for 1:1 mapping */
                     DWordMemory(
                         ResourceProducer, PosDecode, MinFixed, MaxFixed,
                         Cacheable, ReadWrite,
                         0x00000000,
-                        0xF0000000,
-                        0xF4FFFFFF,
+                        0xB0000000,
+                        0xB7FFFFFF,
+                        0x00000000,
+                        0x08000000)
+
+                    DWordMemory(
+                        ResourceProducer, PosDecode, MinFixed, MaxFixed,
+                        NonCacheable, ReadWrite,
+                        0x00000000,
+                        0xF4000000,
+                        0xF5FFFFFF,
+                        0x00000000,
+                        0x02000000)
+
+                    DWordMemory(
+                        ResourceProducer, PosDecode, MinFixed, MaxFixed,
+                        Cacheable, ReadWrite,
+                        0x00000000,
+                        0xB8000000,
+                        0xBBFFFFFF,
+                        0x00000000,
+                        0x04000000)
+
+                    DWordMemory(
+                        ResourceProducer, PosDecode, MinFixed, MaxFixed,
+                        Cacheable, ReadWrite,
+                        0x00000000,
+                        0xF6000000,
+                        0xFAFFFFFF,
                         0x00000000,
                         0x05000000,
                         ,, _Y01)
                 })
 
                 CreateDWordField(PRT0, \_SB.PCI0._CRS._Y01._MIN, MMIN)
                 CreateDWordField(PRT0, \_SB.PCI0._CRS._Y01._MAX, MMAX)
                 CreateDWordField(PRT0, \_SB.PCI0._CRS._Y01._LEN, MLEN)
 
                 Store(\_SB.PMIN, MMIN)
                 Store(\_SB.PLEN, MLEN)
                 Add(MMIN, MLEN, MMAX)
                 Subtract(MMAX, One, MMAX)
 
                 Return (PRT0)
             }
 
             Device(HPET) {
--- tools/firmware/hvmloader/hvmloader.c.orig	2011-05-05 21:18:46.314526582 +0000
+++ tools/firmware/hvmloader/hvmloader.c	2011-05-02 15:28:34.000000000 +0000
@@ -28,8 +28,9 @@
 #include <xen/version.h>
 #include <xen/hvm/params.h>
 
 #define ROM_INCLUDE_VGABIOS
+#define ROM_INCLUDE_PTVGABIOS
 #define ROM_INCLUDE_ETHERBOOT
 #include "roms.inc"
 
 asm (
@@ -113,8 +114,11 @@
 unsigned long pci_mem_end = PCI_MEM_END;
 
 enum virtual_vga virtual_vga = VGA_none;
 
+/* virtual BDF of pass-throughed gfx */
+uint8_t gfx_bdf;
+
 static void init_hypercalls(void)
 {
     uint32_t eax, ebx, ecx, edx;
     unsigned long i;
@@ -432,10 +436,12 @@
         vgabios_sz = round_option_rom(sizeof(vgabios_stdvga));
         break;
     case VGA_pt:
         printf("Loading VGABIOS of passthroughed gfx ...\n");
-        vgabios_sz =
-            round_option_rom((*(uint8_t *)(VGABIOS_PHYSICAL_ADDRESS+2)) * 512);
+        memcpy((void *)VGABIOS_PHYSICAL_ADDRESS,
+               vgabios_pt, sizeof(vgabios_pt));
+        *(uint8_t *)(VGABIOS_PHYSICAL_ADDRESS + sizeof(vgabios_pt)) = gfx_bdf;
+        vgabios_sz = round_option_rom(sizeof(vgabios_pt) + 1);
         break;
     default:
         printf("No emulated VGA adaptor ...\n");
         break;
--- tools/firmware/hvmloader/Makefile.orig	2011-05-05 21:18:46.314526582 +0000
+++ tools/firmware/hvmloader/Makefile	2011-05-02 14:33:47.000000000 +0000
@@ -55,8 +55,9 @@
 CIRRUSVGA_ROM := ../vgabios/VGABIOS-lgpl-latest.cirrus.debug.bin
 else
 CIRRUSVGA_ROM := ../vgabios/VGABIOS-lgpl-latest.cirrus.bin
 endif
+PTVGA_ROM     := ../vgabios/vgabios-pt.bin
 
 .PHONY: all
 all: subdirs-all
 	$(MAKE) hvmloader
@@ -93,8 +94,13 @@
 	echo "#ifdef ROM_INCLUDE_VGABIOS" >> $@.new
 	sh ./mkhex vgabios_cirrusvga $(CIRRUSVGA_ROM) >> $@.new
 	echo "#endif" >> $@.new
 endif
+ifneq ($(PTVGA_ROM),)
+	echo "#ifdef ROM_INCLUDE_PTVGABIOS" >> $@.new
+	sh ./mkhex vgabios_pt $(PTVGA_ROM) >> $@.new
+	echo "#endif" >> $@.new
+endif
 
 	echo "#ifdef ROM_INCLUDE_ETHERBOOT" >> $@.new
 	cat ../etherboot/eb-roms.h >> $@.new
 	echo "#endif" >> $@.new
--- tools/ioemu-remote/hw/pass-through.c.orig	2011-05-05 21:18:44.914414545 +0000
+++ tools/ioemu-remote/hw/pass-through.c	2011-05-03 00:40:39.323043803 +0000
@@ -3242,8 +3311,10 @@
     return 0;
 }
 
 /* read BAR */
+static int gfx_first_read_BAR[7] = {1, 1, 1, 1, 1, 1, 1};
+
 static int pt_bar_reg_read(struct pt_dev *ptdev,
         struct pt_reg_tbl *cfg_entry,
         uint32_t *value, uint32_t valid_mask)
 {
@@ -3264,8 +3335,19 @@
 
     /* use fixed-up value from kernel sysfs */
     *value = ptdev->pci_dev->base_addr[index];
 
+    if ( ptdev->pci_dev->device_class == 0x300 )
+    {
+        if ( gfx_first_read_BAR[index] == 1 )
+        {
+            gfx_first_read_BAR[index] = 0;
+            PT_LOG("first read BARs of gfx\n");
+            return 0;
+        }
+    }
+
+
     /* set emulate mask depend on BAR flag */
     switch (ptdev->bases[index].bar_flag)
     {
     case PT_BAR_FLAG_MEM:
--- tools/firmware/hvmloader/rombios.c.orig	2011-05-05 21:18:46.306458208 +0000
+++ tools/firmware/hvmloader/rombios.c	2011-05-02 15:35:04.000000000 +0000
@@ -41,8 +41,11 @@
 #define ROMBIOS_SIZE           0x00010000
 #define ROMBIOS_MAXOFFSET      0x0000FFFF
 #define ROMBIOS_END            (ROMBIOS_BEGIN + ROMBIOS_SIZE)
 
+/* virtual BDF of pass-throughed gfx declared in hvmloader.c*/
+extern uint8_t gfx_bdf;
+
 /*
  * Set up an empty TSS area for virtual 8086 mode to use. 
  * The only important thing is that it musn't have any bits set 
  * in the interrupt redirection bitmap, so all zeros will do.
@@ -151,8 +154,46 @@
             else if ( (vendor_id == 0x1013) && (device_id == 0xb8) )
                 virtual_vga = VGA_cirrus;
             else if ( virtual_vga == VGA_none )
-                virtual_vga = VGA_pt;
+            {
+                virtual_vga = VGA_pt;
+                gfx_bdf = devfn;
+
+                /* Make vBAR=pBAR */
+                printf("Make vBAR = pBAR of assigned gfx\n");
+                for ( bar = 0; bar < 7; bar++ )
+                {
+                    bar_reg = PCI_BASE_ADDRESS_0 + 4*bar;
+                    if ( bar == 6 )
+                            bar_reg = PCI_ROM_ADDRESS;
+                    /* When first time read, it will return physical address */
+                    bar_data = pci_readl(devfn, bar_reg);
+                    pci_writel(devfn, bar_reg, bar_data);
+
+                    /* Now enable the memory or I/O mapping. */
+                    cmd = pci_readw(devfn, PCI_COMMAND);
+                    if ( (bar_reg == PCI_ROM_ADDRESS) ||
+                             ((bar_data & PCI_BASE_ADDRESS_SPACE) ==
+                              PCI_BASE_ADDRESS_SPACE_MEMORY) )
+                          cmd |= PCI_COMMAND_MEMORY;
+                    else
+                          cmd |= PCI_COMMAND_IO;
+                    cmd |= PCI_COMMAND_MASTER;
+                    pci_writew(devfn, PCI_COMMAND, cmd);
+               }
+
+                /* Map the interrupt. */
+                pin = pci_readb(devfn, PCI_INTERRUPT_PIN);
+                if ( pin != 0 )
+                {
+                    /* This is the barber's pole mapping used by Xen. */
+                    link = ((pin - 1) + (devfn >> 3)) & 3;
+                    isa_irq = pci_readb(PCI_ISA_DEVFN, 0x60 + link);
+                    pci_writeb(devfn, PCI_INTERRUPT_LINE, isa_irq);
+                }
+                continue;
+            }
+
             break;
         case 0x0680:
             /* PIIX4 ACPI PM. Special device with special PCI config space. */
             ASSERT((vendor_id == 0x8086) && (device_id == 0x7113));

[-- Attachment #3: qemu-dm-W7Test.log --]
[-- Type: application/octet-stream, Size: 12541 bytes --]

domid: 1
Using file /dev/mapper/VMStore-W7Test in read-write mode
Strip off blktap sub-type prefix to /w7.iso (drv 'aio')
Using file /w7.iso in read-only mode
Watching /local/domain/0/device-model/1/logdirty/cmd
Watching /local/domain/0/device-model/1/command
Watching /local/domain/1/cpu
char device redirected to /dev/pts/2
qemu_map_cache_init nr_buckets = 10000 size 4194304
shared page at pfn feffd
buffered io page at pfn feffb
Guest uuid = 219251f8-2887-44a6-9447-39087b862786
Register xen platform.
Done register platform.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw state.
xs_read(/local/domain/0/device-model/1/xen_extended_power_mgmt): read error
medium change watch on `hda' (index: 1): aio:/w7.iso
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
Log-dirty: no command yet.
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
vcpu-set: watch node error.
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
xs_read(/local/domain/1/log-throttling): read error
qemu: ignoring not-understood drive `/local/domain/1/log-throttling'
medium change watch on `/local/domain/1/log-throttling' - unknown device, ignored
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 01:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x1:0x0.0x0
pt_register_regions: IO region registered (size=0x02000000 base_addr=0xf4000000)
pt_register_regions: IO region registered (size=0x08000000 base_addr=0xb000000c)
pt_register_regions: IO region registered (size=0x04000000 base_addr=0xb800000c)
pt_register_regions: IO region registered (size=0x00000080 base_addr=0x00004c01)
pt_register_regions: Expansion ROM registered (size=0x00080000 base_addr=0xaff00002)
pcilib: Cannot open /sys/bus/pci/devices/0000:00:02.0/config
pcilib: Cannot open /sys/bus/pci/devices/0000:00:02.0/config
setup_vga_pt: vga bios checksum is adjusted!
pt_msi_setup: msi mapped with pirq 37
pci_intx: intx=1
register_real_device: Real physical device 01:00.0 registered successfuly!
IRQ type = MSI-INTx
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 01:00.1 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x1:0x0.0x1
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xf2100000)
pt_msi_setup: msi mapped with pirq 36
pci_intx: intx=2
register_real_device: Real physical device 01:00.1 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 0e:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0xe:0x0.0x0
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xfbb00004)
pt_register_regions: IO region registered (size=0x00000100 base_addr=0x0000b801)
pt_register_regions: Expansion ROM registered (size=0x00020000 base_addr=0xa0600000)
pt_msi_setup: msi mapped with pirq 35
pci_intx: intx=1
register_real_device: Real physical device 0e:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 04:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x4:0x0.0x0
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xf6340004)
pt_register_regions: IO region registered (size=0x00800000 base_addr=0xf6800004)
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xf6341004)
pt_register_regions: Expansion ROM registered (size=0x00040000 base_addr=0xf6300000)
pt_msix_init: get MSI-X table bar base f6341000
pt_msix_init: table_off = 0, total_entries = 32
pt_msix_init: errno = 2
pt_msix_init: mapping physical MSI-X table to 7f7feff14000
pt_msi_setup: msi mapped with pirq 34
pci_intx: intx=1
register_real_device: Real physical device 04:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1a.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1a.0x0
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xa0c04000)
pci_intx: intx=1
register_real_device: Real physical device 00:1a.0 registered successfuly!
IRQ type = INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1b.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1b.0x0
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xa0c00004)
pt_msi_setup: msi mapped with pirq 33
pci_intx: intx=1
register_real_device: Real physical device 00:1b.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1d.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1d.0x0
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xa0c05000)
pci_intx: intx=1
register_real_device: Real physical device 00:1d.0 registered successfuly!
IRQ type = INTx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=f4000000 maddr=f4000000 type=0 len=33554432 index=0 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=b0000000 maddr=b0000000 type=8 len=134217728 index=1 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=b8000000 maddr=b8000000 type=8 len=67108864 index=3 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_ioport_map: e_phys=4c00 pio_base=4c00 len=128 index=5 first_map=1
pt_iomem_map: e_phys=f1000000 maddr=f6800000 type=0 len=8388608 index=2 first_map=1
pt_iomem_map: e_phys=f1860000 maddr=f2100000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f1864000 maddr=fbb00000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f1868000 maddr=a0c00000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f186c000 maddr=f6340000 type=0 len=4096 index=0 first_map=1
pt_iomem_map: e_phys=f186d000 maddr=f6341000 type=0 len=4096 index=4 first_map=1
pt_iomem_map: e_phys=f186e000 maddr=a0c04000 type=0 len=4096 index=0 first_map=1
pt_iomem_map: e_phys=f186f000 maddr=a0c05000 type=0 len=4096 index=0 first_map=1
pt_ioport_map: e_phys=c200 pio_base=b800 len=256 index=2 first_map=1
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw state.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is ro state.
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_iomem_map: e_phys=ffffffff maddr=f4000000 type=0 len=33554432 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=b0000000 type=8 len=134217728 index=1 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=b8000000 type=8 len=67108864 index=3 first_map=0
pt_ioport_map: e_phys=ffff pio_base=4c00 len=128 index=5 first_map=0
pt_iomem_map: e_phys=f4000000 maddr=f4000000 type=0 len=33554432 index=0 first_map=0
pt_iomem_map: e_phys=b0000000 maddr=b0000000 type=8 len=134217728 index=1 first_map=0
pt_iomem_map: e_phys=b8000000 maddr=b8000000 type=8 len=67108864 index=3 first_map=0
pt_ioport_map: e_phys=4c00 pio_base=4c00 len=128 index=5 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=f2100000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=f1860000 maddr=f2100000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=fbb00000 type=0 len=16384 index=0 first_map=0
pt_ioport_map: e_phys=ffff pio_base=b800 len=256 index=2 first_map=0
pt_iomem_map: e_phys=f1864000 maddr=fbb00000 type=0 len=16384 index=0 first_map=0
pt_ioport_map: e_phys=c200 pio_base=b800 len=256 index=2 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=f6340000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=f6800000 type=0 len=8388608 index=2 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=f6341000 type=0 len=4096 index=4 first_map=0
pt_iomem_map: e_phys=f186c000 maddr=f6340000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=f1000000 maddr=f6800000 type=0 len=8388608 index=2 first_map=0
pt_iomem_map: e_phys=f186d000 maddr=f6341000 type=0 len=4096 index=4 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c04000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=f186e000 maddr=a0c04000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c00000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=f1868000 maddr=a0c00000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c05000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=f186f000 maddr=a0c05000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=f4000000 type=0 len=33554432 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=b0000000 type=8 len=134217728 index=1 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=b8000000 type=8 len=67108864 index=3 first_map=0
pt_ioport_map: e_phys=ffff pio_base=4c00 len=128 index=5 first_map=0
pt_iomem_map: e_phys=f4000000 maddr=f4000000 type=0 len=33554432 index=0 first_map=0
pt_iomem_map: e_phys=b0000000 maddr=b0000000 type=8 len=134217728 index=1 first_map=0
pt_iomem_map: e_phys=b8000000 maddr=b8000000 type=8 len=67108864 index=3 first_map=0
pt_ioport_map: e_phys=4c00 pio_base=4c00 len=128 index=5 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=fbb00000 type=0 len=16384 index=0 first_map=0
pt_ioport_map: e_phys=ffff pio_base=b800 len=256 index=2 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=f2100000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=f1864000 maddr=fbb00000 type=0 len=16384 index=0 first_map=0
pt_ioport_map: e_phys=c200 pio_base=b800 len=256 index=2 first_map=0
pt_iomem_map: e_phys=f1860000 maddr=f2100000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c04000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=f186e000 maddr=a0c04000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c05000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=ffffffff maddr=a0c00000 type=0 len=16384 index=0 first_map=0
pt_iomem_map: e_phys=f186f000 maddr=a0c05000 type=0 len=4096 index=0 first_map=0
pt_iomem_map: e_phys=f1868000 maddr=a0c00000 type=0 len=16384 index=0 first_map=0

[-- Attachment #4: dmesg.log --]
[-- Type: application/octet-stream, Size: 43252 bytes --]

 __  __            _  _    ____                     _        _     _      
 \ \/ /___ _ __   | || |  |___ \    _   _ _ __  ___| |_ __ _| |__ | | ___ 
  \  // _ \ '_ \  | || |_   __) |__| | | | '_ \/ __| __/ _` | '_ \| |/ _ \
  /  \  __/ | | | |__   _| / __/|__| |_| | | | \__ \ || (_| | |_) | |  __/
 /_/\_\___|_| |_|    |_|(_)_____|   \__,_|_| |_|___/\__\__,_|_.__/|_|\___|
                                                                          
(XEN) Xen version 4.2-unstable (root@localhost) (gcc version 4.5.2 (Debian 4.5.2-11) ) Tue May 24 18:41:36 SGT 2011
(XEN) Latest ChangeSet: Mon May 23 17:38:28 2011 +0100 23369:37c77bacb52a
(XEN) Bootloader: GRUB 1.99~rc1-13
(XEN) Command line: placeholder dom0_mem=1024M loglvl=all guest_loglvl=all
(XEN) Video information:
(XEN)  VGA is text mode 80x25, font 8x16
(XEN)  VBE/DDC methods: none; EDID transfer time: 0 seconds
(XEN)  EDID info not retrieved because no DDC retrieval method detected
(XEN) Disc information:
(XEN)  Found 0 MBR signatures
(XEN)  Found 6 EDD information structures
(XEN) Xen-e820 RAM map:
(XEN)  0000000000000000 - 0000000000096c00 (usable)
(XEN)  0000000000096c00 - 00000000000a0000 (reserved)
(XEN)  00000000000e0000 - 0000000000100000 (reserved)
(XEN)  0000000000100000 - 000000009f780000 (usable)
(XEN)  000000009f780000 - 000000009f78e000 (ACPI data)
(XEN)  000000009f78e000 - 000000009f7d0000 (ACPI NVS)
(XEN)  000000009f7d0000 - 000000009f7e0000 (reserved)
(XEN)  000000009f7ed000 - 00000000a0000000 (reserved)
(XEN)  00000000fee00000 - 00000000fee01000 (reserved)
(XEN)  00000000ffa00000 - 0000000100000000 (reserved)
(XEN)  0000000100000000 - 0000000460000000 (usable)
(XEN) ACPI: RSDP 000F9AA0, 0024 (r2 ACPIAM)
(XEN) ACPI: XSDT 9F780100, 005C (r1 090909 XSDT1600 20090909 MSFT       97)
(XEN) ACPI: FACP 9F780290, 00F4 (r4 090909 FACP1600 20090909 MSFT       97)
(XEN) ACPI: DSDT 9F780460, 5910 (r2  1E659 1E659A27      A27 INTL 20051117)
(XEN) ACPI: FACS 9F78E000, 0040
(XEN) ACPI: APIC 9F780390, 008C (r2 090909 APIC1600 20090909 MSFT       97)
(XEN) ACPI: MCFG 9F780420, 003C (r1 090909 OEMMCFG  20090909 MSFT       97)
(XEN) ACPI: OEMB 9F78E040, 0072 (r1 090909 OEMB1600 20090909 MSFT       97)
(XEN) ACPI: HPET 9F78A460, 0038 (r1 090909 OEMHPET  20090909 MSFT       97)
(XEN) ACPI: DMAR 9F78E0C0, 0090 (r1    AMI  OEMDMAR        1 MSFT       97)
(XEN) ACPI: SSDT 9F790E30, 0363 (r1 DpgPmm    CpuPm       12 INTL 20051117)
(XEN) System RAM: 16375MB (16768088kB)
(XEN) No NUMA configuration found
(XEN) Faking a node at 0000000000000000-0000000460000000
(XEN) Domain heap initialised
(XEN) found SMP MP-table at 000ff780
(XEN) DMI present.
(XEN) Using APIC driver default
(XEN) ACPI: PM-Timer IO Port: 0x808
(XEN) ACPI: ACPI SLEEP INFO: pm1x_cnt[804,0], pm1x_evt[800,0]
(XEN) ACPI:                  wakeup_vec[9f78e00c], vec_size[20]
(XEN) ACPI: Local APIC address 0xfee00000
(XEN) ACPI: LAPIC (acpi_id[0x01] lapic_id[0x00] enabled)
(XEN) Processor #0 7:14 APIC version 21
(XEN) ACPI: LAPIC (acpi_id[0x02] lapic_id[0x02] enabled)
(XEN) Processor #2 7:14 APIC version 21
(XEN) ACPI: LAPIC (acpi_id[0x03] lapic_id[0x04] enabled)
(XEN) Processor #4 7:14 APIC version 21
(XEN) ACPI: LAPIC (acpi_id[0x04] lapic_id[0x06] enabled)
(XEN) Processor #6 7:14 APIC version 21
(XEN) ACPI: LAPIC (acpi_id[0x05] lapic_id[0x01] enabled)
(XEN) Processor #1 7:14 APIC version 21
(XEN) ACPI: LAPIC (acpi_id[0x06] lapic_id[0x03] enabled)
(XEN) Processor #3 7:14 APIC version 21
(XEN) ACPI: LAPIC (acpi_id[0x07] lapic_id[0x05] enabled)
(XEN) Processor #5 7:14 APIC version 21
(XEN) ACPI: LAPIC (acpi_id[0x08] lapic_id[0x07] enabled)
(XEN) Processor #7 7:14 APIC version 21
(XEN) ACPI: IOAPIC (id[0x08] address[0xfec00000] gsi_base[0])
(XEN) IOAPIC[0]: apic_id 8, version 32, address 0xfec00000, GSI 0-23
(XEN) ACPI: INT_SRC_OVR (bus 0 bus_irq 0 global_irq 2 dfl dfl)
(XEN) ACPI: INT_SRC_OVR (bus 0 bus_irq 9 global_irq 20 low level)
(XEN) ACPI: IRQ0 used by override.
(XEN) ACPI: IRQ2 used by override.
(XEN) ACPI: IRQ9 used by override.
(XEN) Enabling APIC mode:  Flat.  Using 1 I/O APICs
(XEN) ACPI: HPET id: 0xffffffff base: 0xfed00000
(XEN) PCI: MCFG configuration 0: base e0000000 segment 0 buses 0 - 255
(XEN) PCI: Not using MMCONFIG.
(XEN) Table is not found!
(XEN) Using ACPI (MADT) for SMP configuration information
(XEN) IRQ limits: 24 GSI, 1528 MSI/MSI-X
(XEN) Using scheduler: SMP Credit Scheduler (credit)
(XEN) Detected 2929.699 MHz processor.
(XEN) Initing memory sharing.
(XEN) mce_intel.c:1179: MCA Capability: BCAST 1 SER 0 CMCI 1 firstbank 0 extended MCE MSR 0
(XEN) Intel machine check reporting enabled
(XEN) Intel VT-d Snoop Control enabled.
(XEN) Intel VT-d Dom0 DMA Passthrough not enabled.
(XEN) Intel VT-d Queued Invalidation enabled.
(XEN) Intel VT-d Interrupt Remapping not enabled.
(XEN) Intel VT-d Shared EPT tables not enabled.
(XEN) I/O virtualisation enabled
(XEN)  - Dom0 mode: Relaxed
(XEN) ENABLING IO-APIC IRQs
(XEN)  -> Using new ACK method
(XEN) ..TIMER: vector=0xF0 apic1=0 pin1=2 apic2=-1 pin2=-1
(XEN) Platform timer is 14.318MHz HPET
(XEN) Allocated console ring of 64 KiB.
(XEN) VMX: Supported advanced features:
(XEN)  - APIC MMIO access virtualisation
(XEN)  - APIC TPR shadow
(XEN)  - Extended Page Tables (EPT)
(XEN)  - Virtual-Processor Identifiers (VPID)
(XEN)  - Virtual NMI
(XEN)  - MSR direct-access bitmap
(XEN) EPT supports 2MB super page.
(XEN) HVM: ASIDs enabled.
(XEN) HVM: VMX enabled
(XEN) HVM: Hardware Assisted Paging detected.
(XEN) Brought up 8 CPUs
(XEN) HPET: 8 timers (8 will be used for broadcast)
(XEN) ACPI sleep modes: S3
(XEN) mcheck_poll: Machine check polling timer started.
(XEN) *** LOADING DOMAIN 0 ***
(XEN) elf_parse_binary: phdr: paddr=0x1000000 memsz=0x51e000
(XEN) elf_parse_binary: phdr: paddr=0x151e000 memsz=0x90000
(XEN) elf_parse_binary: phdr: paddr=0x15ae000 memsz=0x8c8
(XEN) elf_parse_binary: phdr: paddr=0x15af000 memsz=0x16498
(XEN) elf_parse_binary: phdr: paddr=0x15c6000 memsz=0x297000
(XEN) elf_parse_binary: memory: 0x1000000 -> 0x185d000
(XEN) elf_xen_parse_note: GUEST_OS = "linux"
(XEN) elf_xen_parse_note: GUEST_VERSION = "2.6"
(XEN) elf_xen_parse_note: XEN_VERSION = "xen-3.0"
(XEN) elf_xen_parse_note: VIRT_BASE = 0xffffffff80000000
(XEN) elf_xen_parse_note: ENTRY = 0xffffffff815c6200
(XEN) elf_xen_parse_note: HYPERCALL_PAGE = 0xffffffff81009000
(XEN) elf_xen_parse_note: FEATURES = "!writable_page_tables|pae_pgdir_above_4gb"
(XEN) elf_xen_parse_note: PAE_MODE = "yes"
(XEN) elf_xen_parse_note: LOADER = "generic"
(XEN) elf_xen_parse_note: unknown xen elf note (0xd)
(XEN) elf_xen_parse_note: SUSPEND_CANCEL = 0x1
(XEN) elf_xen_parse_note: HV_START_LOW = 0xffff800000000000
(XEN) elf_xen_parse_note: PADDR_OFFSET = 0x0
(XEN) elf_xen_addr_calc_check: addresses:
(XEN)     virt_base        = 0xffffffff80000000
(XEN)     elf_paddr_offset = 0x0
(XEN)     virt_offset      = 0xffffffff80000000
(XEN)     virt_kstart      = 0xffffffff81000000
(XEN)     virt_kend        = 0xffffffff8185d000
(XEN)     virt_entry       = 0xffffffff815c6200
(XEN)     p2m_base         = 0xffffffffffffffff
(XEN)  Xen  kernel: 64-bit, lsb, compat32
(XEN)  Dom0 kernel: 64-bit, PAE, lsb, paddr 0x1000000 -> 0x185d000
(XEN) PHYSICAL MEMORY ARRANGEMENT:
(XEN)  Dom0 alloc.:   000000044e000000->0000000450000000 (246309 pages to be allocated)
(XEN)  Init. ramdisk: 000000045e225000->000000045ffff400
(XEN) VIRTUAL MEMORY ARRANGEMENT:
(XEN)  Loaded kernel: ffffffff81000000->ffffffff8185d000
(XEN)  Init. ramdisk: ffffffff8185d000->ffffffff83637400
(XEN)  Phys-Mach map: ffffffff83638000->ffffffff83838000
(XEN)  Start info:    ffffffff83838000->ffffffff838384b4
(XEN)  Page tables:   ffffffff83839000->ffffffff8385a000
(XEN)  Boot stack:    ffffffff8385a000->ffffffff8385b000
(XEN)  TOTAL:         ffffffff80000000->ffffffff83c00000
(XEN)  ENTRY ADDRESS: ffffffff815c6200
(XEN) Dom0 has maximum 8 VCPUs
(XEN) elf_load_binary: phdr 0 at 0xffffffff81000000 -> 0xffffffff8151e000
(XEN) elf_load_binary: phdr 1 at 0xffffffff8151e000 -> 0xffffffff815ae000
(XEN) elf_load_binary: phdr 2 at 0xffffffff815ae000 -> 0xffffffff815ae8c8
(XEN) elf_load_binary: phdr 3 at 0xffffffff815af000 -> 0xffffffff815c5498
(XEN) elf_load_binary: phdr 4 at 0xffffffff815c6000 -> 0xffffffff8164e000
(XEN) Scrubbing Free RAM: .......................................................................................................................................................done.
(XEN) Std. Loglevel: All
(XEN) Guest Loglevel: All
(XEN) Xen is relinquishing VGA console.
(XEN) *** Serial input -> DOM0 (type 'CTRL-a' three times to switch input to Xen)
(XEN) Freed 224kB init memory.
(XEN) PCI add device 00:00.0
(XEN) PCI add device 00:03.0
(XEN) PCI add device 00:05.0
(XEN) PCI add device 00:08.0
(XEN) PCI add device 00:08.1
(XEN) PCI add device 00:08.2
(XEN) PCI add device 00:08.3
(XEN) PCI add device 00:10.0
(XEN) PCI add device 00:10.1
(XEN) PCI add device 00:1a.0
(XEN) PCI add device 00:1b.0
(XEN) PCI add device 00:1c.0
(XEN) PCI add device 00:1c.4
(XEN) PCI add device 00:1c.5
(XEN) PCI add device 00:1c.6
(XEN) PCI add device 00:1c.7
(XEN) PCI add device 00:1d.0
(XEN) PCI add device 00:1e.0
(XEN) PCI add device 00:1f.0
(XEN) PCI add device 00:1f.2
(XEN) PCI add device 00:1f.3
(XEN) PCI add device 01:00.0
(XEN) PCI add device 01:00.1
(XEN) PCI add device 02:00.0
(XEN) PCI add device 03:00.0
(XEN) PCI add device 03:01.0
(XEN) PCI add device 03:02.0
(XEN) PCI add device 04:00.0
(XEN) PCI add device 05:00.0
(XEN) PCI add device 06:02.0
(XEN) PCI add device 06:03.0
(XEN) PCI add device 06:04.0
(XEN) PCI add device 06:05.0
(XEN) PCI add device 07:00.0
(XEN) PCI add device 08:00.0
(XEN) PCI add device 09:00.0
(XEN) PCI add device 0a:00.0
(XEN) PCI add device 0b:00.0
(XEN) PCI add device 0b:00.1
(XEN) PCI add device 0d:00.0
(XEN) PCI add device 0e:00.0
(XEN) PCI add device 0f:00.0
(XEN) PCI add device 10:00.0
(XEN) PCI add device 10:00.1
(XEN) PCI add device 11:03.0
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-1 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-1 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-1 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-1 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-1 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-1 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-1 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-1 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) cpuid.MWAIT[.eax=40, .ebx=40, .ecx=3, .edx=1120]
(XEN) Monitor-Mwait will be used to enter C-3 state
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=3b0 f_mport=3b0 np=c
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=3c0 f_mport=3c0 np=20
(XEN) domctl.c:986:d0 memory_map:add: gfn=a0 mfn=a0 nr_mfns=20
(XEN) physdev.c:170: dom1: 17:-1 already mapped to 17
(XEN) physdev.c:170: dom1: 16:-1 already mapped to 16
(XEN) physdev.c:170: dom1: 16:-1 already mapped to 16
(XEN) HVM1: HVM Loader
(XEN) HVM1: Detected Xen v4.2-unstable
(XEN) HVM1: Xenbus rings @0xfeffc000, event channel 9
(XEN) HVM1: System requested ROMBIOS
(XEN) HVM1: CPU speed is 2930 MHz
(XEN) irq.c:259: Dom1 PCI link 0 changed 0 -> 5
(XEN) HVM1: PCI-ISA link 0 routed to IRQ5
(XEN) irq.c:259: Dom1 PCI link 1 changed 0 -> 10
(XEN) HVM1: PCI-ISA link 1 routed to IRQ10
(XEN) irq.c:259: Dom1 PCI link 2 changed 0 -> 11
(XEN) HVM1: PCI-ISA link 2 routed to IRQ11
(XEN) irq.c:259: Dom1 PCI link 3 changed 0 -> 5
(XEN) HVM1: PCI-ISA link 3 routed to IRQ5
(XEN) HVM1: pci dev 01:2 INTD->IRQ5
(XEN) HVM1: pci dev 01:3 INTA->IRQ10
(XEN) HVM1: pci dev 03:0 INTA->IRQ5
(XEN) HVM1: pci dev 04:0 INTA->IRQ5
(XEN) HVM1: Make vBAR = pBAR of assigned gfx
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) HVM1: pci dev 06:0 INTB->IRQ5
(XEN) HVM1: pci dev 07:0 INTA->IRQ5
(XEN) HVM1: pci dev 08:0 INTA->IRQ5
(XEN) HVM1: pci dev 09:0 INTA->IRQ10
(XEN) HVM1: pci dev 0a:0 INTA->IRQ11
(XEN) HVM1: pci dev 0b:0 INTA->IRQ5
(XEN) HVM1: pci dev 03:0 bar 14 size 01000000: f0000008
(XEN) HVM1: pci dev 08:0 bar 18 size 00800000: f1000004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) HVM1: pci dev 08:0 bar 30 size 00040000: f1800000
(XEN) HVM1: pci dev 07:0 bar 30 size 00020000: f1840000
(XEN) HVM1: pci dev 06:0 bar 10 size 00004000: f1860000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) HVM1: pci dev 07:0 bar 10 size 00004000: f1864004
(XEN) HVM1: pci dev 0a:0 bar 10 size 00004000: f1868004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) HVM1: pci dev 08:0 bar 10 size 00001000: f186c004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) HVM1: pci dev 08:0 bar 20 size 00001000: f186d004
(XEN) HVM1: pci dev 09:0 bar 10 size 00001000: f186e000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) HVM1: pci dev 0b:0 bar 10 size 00001000: f186f000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) HVM1: pci dev 03:0 bar 10 size 00000100: 0000c001
(XEN) HVM1: pci dev 04:0 bar 10 size 00000100: 0000c101
(XEN) HVM1: pci dev 04:0 bar 14 size 00000100: f1870000
(XEN) HVM1: pci dev 07:0 bar 18 size 00000100: 0000c201
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) HVM1: pci dev 01:2 bar 20 size 00000020: 0000c301
(XEN) HVM1: pci dev 01:1 bar 20 size 00000010: 0000c321
(XEN) HVM1: pci dev 1f:0 bar 10 size 00000010: f1870100
(XEN) HVM1: pci dev 1f:0 bar 14 size 00000010: f1870110
(XEN) HVM1: pci dev 1f:0 bar 18 size 00000010: f1870120
(XEN) HVM1: pci dev 1f:0 bar 1c size 00000010: f1870130
(XEN) HVM1: pci dev 1f:0 bar 20 size 00000010: f1870140
(XEN) HVM1: pci dev 1f:0 bar 24 size 00000010: f1870150
(XEN) HVM1: pci dev 1f:0 bar 30 size 00000010: f1870160
(XEN) HVM1: Multiprocessor initialisation:
(XEN) HVM1:  - CPU0 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM1:  - CPU1 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM1:  - CPU2 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM1:  - CPU3 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM1:  - CPU4 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM1:  - CPU5 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM1:  - CPU6 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM1:  - CPU7 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM1: Testing HVM environment:
(XEN) HVM1:  - REP INSB across page boundaries ... passed
(XEN) HVM1:  - GS base MSRs and SWAPGS ... passed
(XEN) HVM1: Passed 2 of 2 tests
(XEN) HVM1: Writing SMBIOS tables ...
(XEN) HVM1: Loading ROMBIOS ...
(XEN) HVM1: 9852 bytes of ROMBIOS high-memory extensions:
(XEN) HVM1:   Relocating to 0xfc000000-0xfc00267c ... done
(XEN) HVM1: Creating MP tables ...
(XEN) HVM1: Loading VGABIOS of passthroughed gfx ...
(XEN) HVM1: Loading PCI Option ROM ...
(XEN) HVM1:  - Manufacturer: http://etherboot.org
(XEN) HVM1:  - Product name: gPXE
(XEN) HVM1: Loading ACPI ...
(XEN) HVM1:  - Lo data: 000ea020-000ea04f
(XEN) HVM1:  - Hi data: fc002800-fc0129af
(XEN) HVM1: vm86 TSS at fc012c00
(XEN) HVM1: BIOS map:
(XEN) HVM1:  c0000-cefff: VGA BIOS
(XEN) HVM1:  cf000-dcfff: Etherboot ROM
(XEN) HVM1:  eb000-eb269: SMBIOS tables
(XEN) HVM1:  f0000-fffff: Main BIOS
(XEN) HVM1: E820 table:
(XEN) HVM1:  [00]: 00000000:00000000 - 00000000:0009e000: RAM
(XEN) HVM1:  [01]: 00000000:0009e000 - 00000000:0009fc00: RESERVED
(XEN) HVM1:  [02]: 00000000:0009fc00 - 00000000:000a0000: RESERVED
(XEN) HVM1:  HOLE: 00000000:000a0000 - 00000000:000e0000
(XEN) HVM1:  [03]: 00000000:000e0000 - 00000000:00100000: RESERVED
(XEN) HVM1:  [04]: 00000000:00100000 - 00000000:7f800000: RAM
(XEN) HVM1:  HOLE: 00000000:7f800000 - 00000000:fc000000
(XEN) HVM1:  [05]: 00000000:fc000000 - 00000001:00000000: RESERVED
(XEN) HVM1: Invoking ROMBIOS ...
(XEN) HVM1: $Revision: 1.221 $ $Date: 2008/12/07 17:32:29 $
(XEN) HVM1: Bochs BIOS - build: 06/23/99
(XEN) HVM1: $Revision: 1.221 $ $Date: 2008/12/07 17:32:29 $
(XEN) HVM1: Options: apmbios pcibios eltorito PMM 
(XEN) HVM1: 
(XEN) HVM1: ata0 master: QEMU DVD-ROM ATAPI-4 CD-Rom/DVD-Rom
(XEN) HVM1: ata0-1: PCHS=16383/16/63 translation=lba LCHS=1024/255/63
(XEN) HVM1: ata0  slave: QEMU HARDDISK ATA-7 Hard-Disk (61440 MBytes)
(XEN) HVM1: 
(XEN) HVM1: 
(XEN) HVM1: 
(XEN) HVM1: Press F12 for boot menu.
(XEN) HVM1: 
(XEN) HVM1: Booting from Hard Disk...
(XEN) HVM1: Booting from 0000:7c00
(XEN) viridian.c:145:d1 Guest os:
(XEN) viridian.c:147:d1 	vendor: 1
(XEN) viridian.c:149:d1 	os: 4
(XEN) viridian.c:151:d1 	major: 6
(XEN) viridian.c:153:d1 	minor: 1
(XEN) viridian.c:155:d1 	sp: 0
(XEN) viridian.c:157:d1 	build: 1db0
(XEN) viridian.c:162:d1 Set hypercall page 3ffff001.
(XEN) irq.c:259: Dom1 PCI link 0 changed 5 -> 0
(XEN) irq.c:259: Dom1 PCI link 1 changed 10 -> 0
(XEN) irq.c:259: Dom1 PCI link 2 changed 11 -> 0
(XEN) irq.c:259: Dom1 PCI link 3 changed 5 -> 0
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=3b0 f_mport=3b0 np=c
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=3c0 f_mport=3c0 np=20
(XEN) domctl.c:986:d0 memory_map:add: gfn=a0 mfn=a0 nr_mfns=20
(XEN) physdev.c:170: dom2: 17:-1 already mapped to 17
(XEN) physdev.c:170: dom2: 16:-1 already mapped to 16
(XEN) physdev.c:170: dom2: 16:-1 already mapped to 16
(XEN) HVM2: HVM Loader
(XEN) HVM2: Detected Xen v4.2-unstable
(XEN) HVM2: Xenbus rings @0xfeffc000, event channel 9
(XEN) HVM2: System requested ROMBIOS
(XEN) HVM2: CPU speed is 2930 MHz
(XEN) irq.c:259: Dom2 PCI link 0 changed 0 -> 5
(XEN) HVM2: PCI-ISA link 0 routed to IRQ5
(XEN) irq.c:259: Dom2 PCI link 1 changed 0 -> 10
(XEN) HVM2: PCI-ISA link 1 routed to IRQ10
(XEN) irq.c:259: Dom2 PCI link 2 changed 0 -> 11
(XEN) HVM2: PCI-ISA link 2 routed to IRQ11
(XEN) irq.c:259: Dom2 PCI link 3 changed 0 -> 5
(XEN) HVM2: PCI-ISA link 3 routed to IRQ5
(XEN) HVM2: pci dev 01:2 INTD->IRQ5
(XEN) HVM2: pci dev 01:3 INTA->IRQ10
(XEN) HVM2: pci dev 03:0 INTA->IRQ5
(XEN) HVM2: pci dev 04:0 INTA->IRQ5
(XEN) HVM2: Make vBAR = pBAR of assigned gfx
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) HVM2: pci dev 06:0 INTB->IRQ5
(XEN) HVM2: pci dev 07:0 INTA->IRQ5
(XEN) HVM2: pci dev 08:0 INTA->IRQ5
(XEN) HVM2: pci dev 09:0 INTA->IRQ10
(XEN) HVM2: pci dev 0a:0 INTA->IRQ11
(XEN) HVM2: pci dev 0b:0 INTA->IRQ5
(XEN) HVM2: pci dev 03:0 bar 14 size 01000000: f0000008
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) HVM2: pci dev 08:0 bar 18 size 00800000: f1000004
(XEN) HVM2: pci dev 08:0 bar 30 size 00040000: f1800000
(XEN) HVM2: pci dev 07:0 bar 30 size 00020000: f1840000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) HVM2: pci dev 06:0 bar 10 size 00004000: f1860000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) HVM2: pci dev 07:0 bar 10 size 00004000: f1864004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) HVM2: pci dev 0a:0 bar 10 size 00004000: f1868004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) HVM2: pci dev 08:0 bar 10 size 00001000: f186c004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) HVM2: pci dev 08:0 bar 20 size 00001000: f186d004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) HVM2: pci dev 09:0 bar 10 size 00001000: f186e000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) HVM2: pci dev 0b:0 bar 10 size 00001000: f186f000
(XEN) HVM2: pci dev 03:0 bar 10 size 00000100: 0000c001
(XEN) HVM2: pci dev 04:0 bar 10 size 00000100: 0000c101
(XEN) HVM2: pci dev 04:0 bar 14 size 00000100: f1870000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) HVM2: pci dev 07:0 bar 18 size 00000100: 0000c201
(XEN) HVM2: pci dev 01:2 bar 20 size 00000020: 0000c301
(XEN) HVM2: pci dev 01:1 bar 20 size 00000010: 0000c321
(XEN) HVM2: pci dev 1f:0 bar 10 size 00000010: f1870100
(XEN) HVM2: pci dev 1f:0 bar 14 size 00000010: f1870110
(XEN) HVM2: pci dev 1f:0 bar 18 size 00000010: f1870120
(XEN) HVM2: pci dev 1f:0 bar 1c size 00000010: f1870130
(XEN) HVM2: pci dev 1f:0 bar 20 size 00000010: f1870140
(XEN) HVM2: pci dev 1f:0 bar 24 size 00000010: f1870150
(XEN) HVM2: pci dev 1f:0 bar 30 size 00000010: f1870160
(XEN) HVM2: Multiprocessor initialisation:
(XEN) HVM2:  - CPU0 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM2:  - CPU1 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM2:  - CPU2 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM2:  - CPU3 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM2:  - CPU4 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM2:  - CPU5 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM2:  - CPU6 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM2:  - CPU7 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM2: Testing HVM environment:
(XEN) HVM2:  - REP INSB across page boundaries ... passed
(XEN) HVM2:  - GS base MSRs and SWAPGS ... passed
(XEN) HVM2: Passed 2 of 2 tests
(XEN) HVM2: Writing SMBIOS tables ...
(XEN) HVM2: Loading ROMBIOS ...
(XEN) HVM2: 9852 bytes of ROMBIOS high-memory extensions:
(XEN) HVM2:   Relocating to 0xfc000000-0xfc00267c ... done
(XEN) HVM2: Creating MP tables ...
(XEN) HVM2: Loading VGABIOS of passthroughed gfx ...
(XEN) HVM2: Loading PCI Option ROM ...
(XEN) HVM2:  - Manufacturer: http://etherboot.org
(XEN) HVM2:  - Product name: gPXE
(XEN) HVM2: Loading ACPI ...
(XEN) HVM2:  - Lo data: 000ea020-000ea04f
(XEN) HVM2:  - Hi data: fc002800-fc0129af
(XEN) HVM2: vm86 TSS at fc012c00
(XEN) HVM2: BIOS map:
(XEN) HVM2:  c0000-cefff: VGA BIOS
(XEN) HVM2:  cf000-dcfff: Etherboot ROM
(XEN) HVM2:  eb000-eb269: SMBIOS tables
(XEN) HVM2:  f0000-fffff: Main BIOS
(XEN) HVM2: E820 table:
(XEN) HVM2:  [00]: 00000000:00000000 - 00000000:0009e000: RAM
(XEN) HVM2:  [01]: 00000000:0009e000 - 00000000:0009fc00: RESERVED
(XEN) HVM2:  [02]: 00000000:0009fc00 - 00000000:000a0000: RESERVED
(XEN) HVM2:  HOLE: 00000000:000a0000 - 00000000:000e0000
(XEN) HVM2:  [03]: 00000000:000e0000 - 00000000:00100000: RESERVED
(XEN) HVM2:  [04]: 00000000:00100000 - 00000000:7f800000: RAM
(XEN) HVM2:  HOLE: 00000000:7f800000 - 00000000:fc000000
(XEN) HVM2:  [05]: 00000000:fc000000 - 00000001:00000000: RESERVED
(XEN) HVM2: Invoking ROMBIOS ...
(XEN) HVM2: $Revision: 1.221 $ $Date: 2008/12/07 17:32:29 $
(XEN) HVM2: Bochs BIOS - build: 06/23/99
(XEN) HVM2: $Revision: 1.221 $ $Date: 2008/12/07 17:32:29 $
(XEN) HVM2: Options: apmbios pcibios eltorito PMM 
(XEN) HVM2: 
(XEN) HVM2: ata0 master: QEMU DVD-ROM ATAPI-4 CD-Rom/DVD-Rom
(XEN) HVM2: ata0-1: PCHS=16383/16/63 translation=lba LCHS=1024/255/63
(XEN) HVM2: ata0  slave: QEMU HARDDISK ATA-7 Hard-Disk (61440 MBytes)
(XEN) HVM2: 
(XEN) HVM2: 
(XEN) HVM2: 
(XEN) HVM2: Press F12 for boot menu.
(XEN) HVM2: 
(XEN) HVM2: Booting from Hard Disk...
(XEN) HVM2: Booting from 0000:7c00
(XEN) viridian.c:145:d2 Guest os:
(XEN) viridian.c:147:d2 	vendor: 1
(XEN) viridian.c:149:d2 	os: 4
(XEN) viridian.c:151:d2 	major: 6
(XEN) viridian.c:153:d2 	minor: 1
(XEN) viridian.c:155:d2 	sp: 0
(XEN) viridian.c:157:d2 	build: 1db0
(XEN) viridian.c:162:d2 Set hypercall page 3ffff001.
(XEN) irq.c:259: Dom2 PCI link 0 changed 5 -> 0
(XEN) irq.c:259: Dom2 PCI link 1 changed 10 -> 0
(XEN) irq.c:259: Dom2 PCI link 2 changed 11 -> 0
(XEN) irq.c:259: Dom2 PCI link 3 changed 5 -> 0
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=3b0 f_mport=3b0 np=c
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=3c0 f_mport=3c0 np=20
(XEN) domctl.c:986:d0 memory_map:add: gfn=a0 mfn=a0 nr_mfns=20
(XEN) physdev.c:170: dom3: 17:-1 already mapped to 17
(XEN) physdev.c:170: dom3: 16:-1 already mapped to 16
(XEN) physdev.c:170: dom3: 16:-1 already mapped to 16
(XEN) HVM3: HVM Loader
(XEN) HVM3: Detected Xen v4.2-unstable
(XEN) HVM3: Xenbus rings @0xfeffc000, event channel 9
(XEN) HVM3: System requested ROMBIOS
(XEN) HVM3: CPU speed is 2930 MHz
(XEN) irq.c:259: Dom3 PCI link 0 changed 0 -> 5
(XEN) HVM3: PCI-ISA link 0 routed to IRQ5
(XEN) irq.c:259: Dom3 PCI link 1 changed 0 -> 10
(XEN) HVM3: PCI-ISA link 1 routed to IRQ10
(XEN) irq.c:259: Dom3 PCI link 2 changed 0 -> 11
(XEN) HVM3: PCI-ISA link 2 routed to IRQ11
(XEN) irq.c:259: Dom3 PCI link 3 changed 0 -> 5
(XEN) HVM3: PCI-ISA link 3 routed to IRQ5
(XEN) HVM3: pci dev 01:2 INTD->IRQ5
(XEN) HVM3: pci dev 01:3 INTA->IRQ10
(XEN) HVM3: pci dev 03:0 INTA->IRQ5
(XEN) HVM3: pci dev 04:0 INTA->IRQ5
(XEN) HVM3: Make vBAR = pBAR of assigned gfx
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) HVM3: pci dev 06:0 INTB->IRQ5
(XEN) HVM3: pci dev 07:0 INTA->IRQ5
(XEN) HVM3: pci dev 08:0 INTA->IRQ5
(XEN) HVM3: pci dev 09:0 INTA->IRQ10
(XEN) HVM3: pci dev 0a:0 INTA->IRQ11
(XEN) HVM3: pci dev 0b:0 INTA->IRQ5
(XEN) HVM3: pci dev 03:0 bar 14 size 01000000: f0000008
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) HVM3: pci dev 08:0 bar 18 size 00800000: f1000004
(XEN) HVM3: pci dev 08:0 bar 30 size 00040000: f1800000
(XEN) HVM3: pci dev 07:0 bar 30 size 00020000: f1840000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) HVM3: pci dev 06:0 bar 10 size 00004000: f1860000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) HVM3: pci dev 07:0 bar 10 size 00004000: f1864004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) HVM3: pci dev 0a:0 bar 10 size 00004000: f1868004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) HVM3: pci dev 08:0 bar 10 size 00001000: f186c004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) HVM3: pci dev 08:0 bar 20 size 00001000: f186d004
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) HVM3: pci dev 09:0 bar 10 size 00001000: f186e000
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) HVM3: pci dev 0b:0 bar 10 size 00001000: f186f000
(XEN) HVM3: pci dev 03:0 bar 10 size 00000100: 0000c001
(XEN) HVM3: pci dev 04:0 bar 10 size 00000100: 0000c101
(XEN) HVM3: pci dev 04:0 bar 14 size 00000100: f1870000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) HVM3: pci dev 07:0 bar 18 size 00000100: 0000c201
(XEN) HVM3: pci dev 01:2 bar 20 size 00000020: 0000c301
(XEN) HVM3: pci dev 01:1 bar 20 size 00000010: 0000c321
(XEN) HVM3: pci dev 1f:0 bar 10 size 00000010: f1870100
(XEN) HVM3: pci dev 1f:0 bar 14 size 00000010: f1870110
(XEN) HVM3: pci dev 1f:0 bar 18 size 00000010: f1870120
(XEN) HVM3: pci dev 1f:0 bar 1c size 00000010: f1870130
(XEN) HVM3: pci dev 1f:0 bar 20 size 00000010: f1870140
(XEN) HVM3: pci dev 1f:0 bar 24 size 00000010: f1870150
(XEN) HVM3: pci dev 1f:0 bar 30 size 00000010: f1870160
(XEN) HVM3: Multiprocessor initialisation:
(XEN) HVM3:  - CPU0 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM3:  - CPU1 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM3:  - CPU2 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM3:  - CPU3 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM3:  - CPU4 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM3:  - CPU5 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM3:  - CPU6 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM3:  - CPU7 ... 36-bit phys ... fixed MTRRs ... var MTRRs [2/8] ... done.
(XEN) HVM3: Testing HVM environment:
(XEN) HVM3:  - REP INSB across page boundaries ... passed
(XEN) HVM3:  - GS base MSRs and SWAPGS ... passed
(XEN) HVM3: Passed 2 of 2 tests
(XEN) HVM3: Writing SMBIOS tables ...
(XEN) HVM3: Loading ROMBIOS ...
(XEN) HVM3: 9852 bytes of ROMBIOS high-memory extensions:
(XEN) HVM3:   Relocating to 0xfc000000-0xfc00267c ... done
(XEN) HVM3: Creating MP tables ...
(XEN) HVM3: Loading VGABIOS of passthroughed gfx ...
(XEN) HVM3: Loading PCI Option ROM ...
(XEN) HVM3:  - Manufacturer: http://etherboot.org
(XEN) HVM3:  - Product name: gPXE
(XEN) HVM3: Loading ACPI ...
(XEN) HVM3:  - Lo data: 000ea020-000ea04f
(XEN) HVM3:  - Hi data: fc002800-fc0129af
(XEN) HVM3: vm86 TSS at fc012c00
(XEN) HVM3: BIOS map:
(XEN) HVM3:  c0000-cefff: VGA BIOS
(XEN) HVM3:  cf000-dcfff: Etherboot ROM
(XEN) HVM3:  eb000-eb269: SMBIOS tables
(XEN) HVM3:  f0000-fffff: Main BIOS
(XEN) HVM3: E820 table:
(XEN) HVM3:  [00]: 00000000:00000000 - 00000000:0009e000: RAM
(XEN) HVM3:  [01]: 00000000:0009e000 - 00000000:0009fc00: RESERVED
(XEN) HVM3:  [02]: 00000000:0009fc00 - 00000000:000a0000: RESERVED
(XEN) HVM3:  HOLE: 00000000:000a0000 - 00000000:000e0000
(XEN) HVM3:  [03]: 00000000:000e0000 - 00000000:00100000: RESERVED
(XEN) HVM3:  [04]: 00000000:00100000 - 00000000:7f800000: RAM
(XEN) HVM3:  HOLE: 00000000:7f800000 - 00000000:fc000000
(XEN) HVM3:  [05]: 00000000:fc000000 - 00000001:00000000: RESERVED
(XEN) HVM3: Invoking ROMBIOS ...
(XEN) HVM3: $Revision: 1.221 $ $Date: 2008/12/07 17:32:29 $
(XEN) HVM3: Bochs BIOS - build: 06/23/99
(XEN) HVM3: $Revision: 1.221 $ $Date: 2008/12/07 17:32:29 $
(XEN) HVM3: Options: apmbios pcibios eltorito PMM 
(XEN) HVM3: 
(XEN) HVM3: ata0 master: QEMU DVD-ROM ATAPI-4 CD-Rom/DVD-Rom
(XEN) HVM3: ata0-1: PCHS=16383/16/63 translation=lba LCHS=1024/255/63
(XEN) HVM3: ata0  slave: QEMU HARDDISK ATA-7 Hard-Disk (61440 MBytes)
(XEN) HVM3: 
(XEN) HVM3: 
(XEN) HVM3: 
(XEN) HVM3: Press F12 for boot menu.
(XEN) HVM3: 
(XEN) HVM3: Booting from Hard Disk...
(XEN) HVM3: Booting from 0000:7c00
(XEN) viridian.c:145:d3 Guest os:
(XEN) viridian.c:147:d3 	vendor: 1
(XEN) viridian.c:149:d3 	os: 4
(XEN) viridian.c:151:d3 	major: 6
(XEN) viridian.c:153:d3 	minor: 1
(XEN) viridian.c:155:d3 	sp: 0
(XEN) viridian.c:157:d3 	build: 1db0
(XEN) viridian.c:162:d3 Set hypercall page 3ffff001.
(XEN) irq.c:259: Dom3 PCI link 0 changed 5 -> 0
(XEN) irq.c:259: Dom3 PCI link 1 changed 10 -> 0
(XEN) irq.c:259: Dom3 PCI link 2 changed 11 -> 0
(XEN) irq.c:259: Dom3 PCI link 3 changed 5 -> 0
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186c mfn=f6340 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1000 mfn=f6800 nr_mfns=800
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186d mfn=f6341 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:996:d0 memory_map:remove: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:986:d0 memory_map:add: gfn=f4000 mfn=f4000 nr_mfns=2000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b0000 mfn=b0000 nr_mfns=8000
(XEN) domctl.c:986:d0 memory_map:add: gfn=b8000 mfn=b8000 nr_mfns=4000
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=4c00 f_mport=4c00 np=80
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1066:d0 ioport_map:remove f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1860 mfn=f2100 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1864 mfn=fbb00 nr_mfns=4
(XEN) domctl.c:1042:d0 ioport_map:add f_gport=c200 f_mport=b800 np=100
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186e mfn=a0c04 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:996:d0 memory_map:remove: gfn=f1868 mfn=a0c00 nr_mfns=4
(XEN) domctl.c:986:d0 memory_map:add: gfn=f186f mfn=a0c05 nr_mfns=1
(XEN) domctl.c:986:d0 memory_map:add: gfn=f1868 mfn=a0c00 nr_mfns=4

[-- Attachment #5: Type: text/plain, Size: 138 bytes --]

_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xensource.com
http://lists.xensource.com/xen-devel

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-09 17:14     ` Javier
  2011-05-10 13:12       ` JavMV
  2011-05-10 13:12       ` JavMV
@ 2011-05-10 13:12       ` JavMV
  2 siblings, 0 replies; 21+ messages in thread
From: JavMV @ 2011-05-10 13:12 UTC (permalink / raw)
  To: xen-devel

Hi again,
I have made some progress, as I posted yesterday I am following these steps
:http://lists.xensource.com/archives/html/xen-devel/2010-05/msg00441.html
I have applied the passthrough patch manually cause there are some errors in
the file, after that I have applied the dsdt patch succesfully. The patches
for the Makefile and hvmloader.c do not work but I can compile the tools
without errors so maybe i dont need it. In fact hvmloader.patch seems to be
the xen-load-vbios-file.patch that Teo En Ming posted, but taking a look to
the code it seems that this patch is already applied in xen-unstable-4.2, or
am I wrong? (This is important... anyone knows if this is correct?)

Well now i have applied 2 patches and have compiled XEN without problems,
the next steps are:
- Extract the firmware of my GTX460 nvidia card with nvflash tool as
vgabios-pt.bin
- Copy it into tools/firmware/vgabios/
- I have the lines gfx_passthru = 1, and pci=['01:00.0'] on my
Windows7VMachine.cfg
- Bind the graphics card to pci-stub:
    echo "10de 0e22" > /sys/bus/pci/drivers/pci-stub/new_id
    echo "0000:01:00.0" > /sys/bus/pci/devices/0000:01:00.0/driver/unbind     
    echo "0000:01:00.0" > /sys/bus/pci/drivers/pci-stub/bind
-Finally create the virtual machine

At this point I have to run VNC in other PC to see my Virtual Machine, but
it doesn't work, i only see the qemu console...

In my qemu log file i can see this:

domid: 1
config qemu network with xen bridge for  tap1.0 eth0
Using file /home/xen/w7/diskw7.img in read-write mode
Using file /dev/cdrom in read-only mode
Watching /local/domain/0/device-model/1/logdirty/cmd
Watching /local/domain/0/device-model/1/command
Watching /local/domain/1/cpu
qemu_map_cache_init nr_buckets = 4000 size 327680
shared page at pfn feffd
buffered io page at pfn feffb
Guest uuid = 1a8ecd4e-3514-652f-615b-eaba86c6a43b
Time offset set 0
Register xen platform.
Done register platform.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw
state.
xs_read(/local/domain/0/device-model/1/xen_extended_power_mgmt): read error
xs_read(): vncpasswd get error.
/vm/1a8ecd4e-3514-652f-615b-eaba86c6a43b/vncpasswd.
medium change watch on `hdc' (index: 1): /dev/cdrom
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
Log-dirty: no command yet.
vcpu-set: watch node error.
xs_read(/local/domain/1/log-throttling): read error
qemu: ignoring not-understood drive `/local/domain/1/log-throttling'
medium change watch on `/local/domain/1/log-throttling' - unknown device,
ignored
dm-command: hot insert pass-through pci dev
register_real_device: Assigning real physical device 01:00.0 ...
register_real_device: Enable MSI translation via per device option
register_real_device: Disable power management
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No
such file or directory: 0x1:0x0.0x0
pt_register_regions: IO region registered (size=0x02000000
base_addr=0xec000000)
pt_register_regions: IO region registered (size=0x08000000
base_addr=0xe000000c)
pt_register_regions: IO region registered (size=0x04000000
base_addr=0xe800000c)
pt_register_regions: IO region registered (size=0x00000080
base_addr=0x00002001)
pt_register_regions: Expansion ROM registered (size=0x00080000
base_addr=0xee080002)
setup_vga_pt: vga bios checksum is adjusted!
gfx_claim_vga_cycle: bridge for bus 7, previous bridge control is 4
gfx_claim_vga_cycle: bus=0x0, dev=0x1e, func=0x0
gfx_claim_vga_cycle: bridge for bus 7, updated bridge control is 4
gfx_claim_vga_cycle: bridge for bus 1, previous bridge control is 18
gfx_claim_vga_cycle: bus=0x0, dev=0x1, func=0x0
gfx_claim_vga_cycle: bridge for bus 1, updated bridge control is 18
gfx_claim_vga_cycle: previous igd control is 32
gfx_claim_vga_cycle: updated igd control is 32
pt_msi_setup: msi mapped with pirq 37
pci_intx: intx=1
register_real_device: Real physical device 01:00.0 registered successfuly!
IRQ type = MSI-INTx
char device redirected to /dev/pts/0
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=ec000000 maddr=ec000000 type=0 len=33554432 index=0
first_map=1
pt_iomem_map: e_phys=e0000000 maddr=e0000000 type=8 len=134217728 index=1
first_map=1
pt_iomem_map: e_phys=e8000000 maddr=e8000000 type=8 len=67108864 index=3
first_map=1
pt_ioport_map: e_phys=2000 pio_base=2000 len=128 index=5 first_map=1
pt_ioport_map: e_phys=c200 pio_base=2000 len=128 index=5 first_map=0
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw
state.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is ro
state.
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=ffffffff maddr=ec000000 type=0 len=33554432 index=0
first_map=0
pt_iomem_map: e_phys=ffffffff maddr=e0000000 type=8 len=134217728 index=1
first_map=0
pt_iomem_map: e_phys=ffffffff maddr=e8000000 type=8 len=67108864 index=3
first_map=0
pt_ioport_map: e_phys=ffff pio_base=2000 len=128 index=5 first_map=0
pt_iomem_map: e_phys=ec000000 maddr=ec000000 type=0 len=33554432 index=0
first_map=0
pt_iomem_map: e_phys=e0000000 maddr=e0000000 type=8 len=134217728 index=1
first_map=0
pt_iomem_map: e_phys=e8000000 maddr=e8000000 type=8 len=67108864 index=3
first_map=0
pt_ioport_map: e_phys=c200 pio_base=2000 len=128 index=5 first_map=0


How can i fix this? 
Is the patch hvmloader already applied in xen-unstable4.2?
Is there any difference between using pci-stub instead of pciback?

With these 2 patches applied I cannot run the virtual machine neither with
gfx_passthru = 0, but without those patches i was able to do it and was able
to see the Nvidia Card inside Windows but with error code43 and a yellow
exclamation symbol...

Any help would be welcome, thanks.




-----
JavMV
--
View this message in context: http://xen.1045712.n5.nabble.com/VGA-passthrough-on-unstable-tp4372548p4384397.html
Sent from the Xen - Dev mailing list archive at Nabble.com.

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-09 17:14     ` Javier
  2011-05-10 13:12       ` JavMV
@ 2011-05-10 13:12       ` JavMV
  2011-05-10 13:12       ` JavMV
  2 siblings, 0 replies; 21+ messages in thread
From: JavMV @ 2011-05-10 13:12 UTC (permalink / raw)
  To: xen-devel

Hi again,
I have made some progress, as I posted yesterday I am following these steps
:http://lists.xensource.com/archives/html/xen-devel/2010-05/msg00441.html
I have applied the passthrough patch manually cause there are some errors in
the file, after that I have applied the dsdt patch succesfully. The patches
for the Makefile and hvmloader.c do not work but I can compile the tools
without errors so maybe i dont need it. In fact hvmloader.patch seems to be
the xen-load-vbios-file.patch that Teo En Ming posted, but taking a look to
the code it seems that this patch is already applied in xen-unstable-4.2, or
am I wrong? (This is important... anyone knows if this is correct?)

Well now i have applied 2 patches and have compiled XEN without problems,
the next steps are:
- Extract the firmware of my GTX460 nvidia card with nvflash tool as
vgabios-pt.bin
- Copy it into tools/firmware/vgabios/
- I have the lines gfx_passthru = 1, and pci=['01:00.0'] on my
Windows7VMachine.cfg
- Bind the graphics card to pci-stub:
    echo "10de 0e22" > /sys/bus/pci/drivers/pci-stub/new_id
    echo "0000:01:00.0" > /sys/bus/pci/devices/0000:01:00.0/driver/unbind     
    echo "0000:01:00.0" > /sys/bus/pci/drivers/pci-stub/bind
-Finally create the virtual machine

At this point I have to run VNC in other PC to see my Virtual Machine, but
it doesn't work, i only see the qemu console...

In my qemu log file i can see this:

domid: 1
config qemu network with xen bridge for  tap1.0 eth0
Using file /home/xen/w7/diskw7.img in read-write mode
Using file /dev/cdrom in read-only mode
Watching /local/domain/0/device-model/1/logdirty/cmd
Watching /local/domain/0/device-model/1/command
Watching /local/domain/1/cpu
qemu_map_cache_init nr_buckets = 4000 size 327680
shared page at pfn feffd
buffered io page at pfn feffb
Guest uuid = 1a8ecd4e-3514-652f-615b-eaba86c6a43b
Time offset set 0
Register xen platform.
Done register platform.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw
state.
xs_read(/local/domain/0/device-model/1/xen_extended_power_mgmt): read error
xs_read(): vncpasswd get error.
/vm/1a8ecd4e-3514-652f-615b-eaba86c6a43b/vncpasswd.
medium change watch on `hdc' (index: 1): /dev/cdrom
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
Log-dirty: no command yet.
vcpu-set: watch node error.
xs_read(/local/domain/1/log-throttling): read error
qemu: ignoring not-understood drive `/local/domain/1/log-throttling'
medium change watch on `/local/domain/1/log-throttling' - unknown device,
ignored
dm-command: hot insert pass-through pci dev
register_real_device: Assigning real physical device 01:00.0 ...
register_real_device: Enable MSI translation via per device option
register_real_device: Disable power management
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No
such file or directory: 0x1:0x0.0x0
pt_register_regions: IO region registered (size=0x02000000
base_addr=0xec000000)
pt_register_regions: IO region registered (size=0x08000000
base_addr=0xe000000c)
pt_register_regions: IO region registered (size=0x04000000
base_addr=0xe800000c)
pt_register_regions: IO region registered (size=0x00000080
base_addr=0x00002001)
pt_register_regions: Expansion ROM registered (size=0x00080000
base_addr=0xee080002)
setup_vga_pt: vga bios checksum is adjusted!
gfx_claim_vga_cycle: bridge for bus 7, previous bridge control is 4
gfx_claim_vga_cycle: bus=0x0, dev=0x1e, func=0x0
gfx_claim_vga_cycle: bridge for bus 7, updated bridge control is 4
gfx_claim_vga_cycle: bridge for bus 1, previous bridge control is 18
gfx_claim_vga_cycle: bus=0x0, dev=0x1, func=0x0
gfx_claim_vga_cycle: bridge for bus 1, updated bridge control is 18
gfx_claim_vga_cycle: previous igd control is 32
gfx_claim_vga_cycle: updated igd control is 32
pt_msi_setup: msi mapped with pirq 37
pci_intx: intx=1
register_real_device: Real physical device 01:00.0 registered successfuly!
IRQ type = MSI-INTx
char device redirected to /dev/pts/0
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=ec000000 maddr=ec000000 type=0 len=33554432 index=0
first_map=1
pt_iomem_map: e_phys=e0000000 maddr=e0000000 type=8 len=134217728 index=1
first_map=1
pt_iomem_map: e_phys=e8000000 maddr=e8000000 type=8 len=67108864 index=3
first_map=1
pt_ioport_map: e_phys=2000 pio_base=2000 len=128 index=5 first_map=1
pt_ioport_map: e_phys=c200 pio_base=2000 len=128 index=5 first_map=0
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw
state.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is ro
state.
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=ffffffff maddr=ec000000 type=0 len=33554432 index=0
first_map=0
pt_iomem_map: e_phys=ffffffff maddr=e0000000 type=8 len=134217728 index=1
first_map=0
pt_iomem_map: e_phys=ffffffff maddr=e8000000 type=8 len=67108864 index=3
first_map=0
pt_ioport_map: e_phys=ffff pio_base=2000 len=128 index=5 first_map=0
pt_iomem_map: e_phys=ec000000 maddr=ec000000 type=0 len=33554432 index=0
first_map=0
pt_iomem_map: e_phys=e0000000 maddr=e0000000 type=8 len=134217728 index=1
first_map=0
pt_iomem_map: e_phys=e8000000 maddr=e8000000 type=8 len=67108864 index=3
first_map=0
pt_ioport_map: e_phys=c200 pio_base=2000 len=128 index=5 first_map=0


How can i fix this? 
Is the patch hvmloader already applied in xen-unstable4.2?
Is there any difference between using pci-stub instead of pciback?

With these 2 patches applied I cannot run the virtual machine neither with
gfx_passthru = 0, but without those patches i was able to do it and was able
to see the Nvidia Card inside Windows but with error code43 and a yellow
exclamation symbol...

Any help would be welcome, thanks.




-----
JavMV
--
View this message in context: http://xen.1045712.n5.nabble.com/VGA-passthrough-on-unstable-tp4372548p4384396.html
Sent from the Xen - Dev mailing list archive at Nabble.com.

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-09 17:14     ` Javier
@ 2011-05-10 13:12       ` JavMV
  2011-05-10 13:12       ` JavMV
  2011-05-10 13:12       ` JavMV
  2 siblings, 0 replies; 21+ messages in thread
From: JavMV @ 2011-05-10 13:12 UTC (permalink / raw)
  To: xen-devel

Hi again,
I have made some progress, as I posted yesterday I am following these steps
:http://lists.xensource.com/archives/html/xen-devel/2010-05/msg00441.html
I have applied the passthrough patch manually cause there are some errors in
the file, after that I have applied the dsdt patch succesfully. The patches
for the Makefile and hvmloader.c do not work but I can compile the tools
without errors so maybe i dont need it. In fact hvmloader.patch seems to be
the xen-load-vbios-file.patch that Teo En Ming posted, but taking a look to
the code it seems that this patch is already applied in xen-unstable-4.2, or
am I wrong? (This is important... anyone knows if this is correct?)

Well now i have applied 2 patches and have compiled XEN without problems,
the next steps are:
- Extract the firmware of my GTX460 nvidia card with nvflash tool as
vgabios-pt.bin
- Copy it into tools/firmware/vgabios/
- I have the lines gfx_passthru = 1, and pci=['01:00.0'] on my
Windows7VMachine.cfg
- Bind the graphics card to pci-stub:
    echo "10de 0e22" > /sys/bus/pci/drivers/pci-stub/new_id
    echo "0000:01:00.0" > /sys/bus/pci/devices/0000:01:00.0/driver/unbind     
    echo "0000:01:00.0" > /sys/bus/pci/drivers/pci-stub/bind
-Finally create the virtual machine

At this point I have to run VNC in other PC to see my Virtual Machine, but
it doesn't work, i only see the qemu console...

In my qemu log file i can see this:

domid: 1
config qemu network with xen bridge for  tap1.0 eth0
Using file /home/xen/w7/diskw7.img in read-write mode
Using file /dev/cdrom in read-only mode
Watching /local/domain/0/device-model/1/logdirty/cmd
Watching /local/domain/0/device-model/1/command
Watching /local/domain/1/cpu
qemu_map_cache_init nr_buckets = 4000 size 327680
shared page at pfn feffd
buffered io page at pfn feffb
Guest uuid = 1a8ecd4e-3514-652f-615b-eaba86c6a43b
Time offset set 0
Register xen platform.
Done register platform.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw
state.
xs_read(/local/domain/0/device-model/1/xen_extended_power_mgmt): read error
xs_read(): vncpasswd get error.
/vm/1a8ecd4e-3514-652f-615b-eaba86c6a43b/vncpasswd.
medium change watch on `hdc' (index: 1): /dev/cdrom
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
Log-dirty: no command yet.
vcpu-set: watch node error.
xs_read(/local/domain/1/log-throttling): read error
qemu: ignoring not-understood drive `/local/domain/1/log-throttling'
medium change watch on `/local/domain/1/log-throttling' - unknown device,
ignored
dm-command: hot insert pass-through pci dev
register_real_device: Assigning real physical device 01:00.0 ...
register_real_device: Enable MSI translation via per device option
register_real_device: Disable power management
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No
such file or directory: 0x1:0x0.0x0
pt_register_regions: IO region registered (size=0x02000000
base_addr=0xec000000)
pt_register_regions: IO region registered (size=0x08000000
base_addr=0xe000000c)
pt_register_regions: IO region registered (size=0x04000000
base_addr=0xe800000c)
pt_register_regions: IO region registered (size=0x00000080
base_addr=0x00002001)
pt_register_regions: Expansion ROM registered (size=0x00080000
base_addr=0xee080002)
setup_vga_pt: vga bios checksum is adjusted!
gfx_claim_vga_cycle: bridge for bus 7, previous bridge control is 4
gfx_claim_vga_cycle: bus=0x0, dev=0x1e, func=0x0
gfx_claim_vga_cycle: bridge for bus 7, updated bridge control is 4
gfx_claim_vga_cycle: bridge for bus 1, previous bridge control is 18
gfx_claim_vga_cycle: bus=0x0, dev=0x1, func=0x0
gfx_claim_vga_cycle: bridge for bus 1, updated bridge control is 18
gfx_claim_vga_cycle: previous igd control is 32
gfx_claim_vga_cycle: updated igd control is 32
pt_msi_setup: msi mapped with pirq 37
pci_intx: intx=1
register_real_device: Real physical device 01:00.0 registered successfuly!
IRQ type = MSI-INTx
char device redirected to /dev/pts/0
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
xen be: console-0: xen be: console-0: initialise() failed
initialise() failed
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=ec000000 maddr=ec000000 type=0 len=33554432 index=0
first_map=1
pt_iomem_map: e_phys=e0000000 maddr=e0000000 type=8 len=134217728 index=1
first_map=1
pt_iomem_map: e_phys=e8000000 maddr=e8000000 type=8 len=67108864 index=3
first_map=1
pt_ioport_map: e_phys=2000 pio_base=2000 len=128 index=5 first_map=1
pt_ioport_map: e_phys=c200 pio_base=2000 len=128 index=5 first_map=0
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw
state.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is ro
state.
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size
alignment. [00:05.0][Offset:0eh][Length:4]
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=ffffffff maddr=ec000000 type=0 len=33554432 index=0
first_map=0
pt_iomem_map: e_phys=ffffffff maddr=e0000000 type=8 len=134217728 index=1
first_map=0
pt_iomem_map: e_phys=ffffffff maddr=e8000000 type=8 len=67108864 index=3
first_map=0
pt_ioport_map: e_phys=ffff pio_base=2000 len=128 index=5 first_map=0
pt_iomem_map: e_phys=ec000000 maddr=ec000000 type=0 len=33554432 index=0
first_map=0
pt_iomem_map: e_phys=e0000000 maddr=e0000000 type=8 len=134217728 index=1
first_map=0
pt_iomem_map: e_phys=e8000000 maddr=e8000000 type=8 len=67108864 index=3
first_map=0
pt_ioport_map: e_phys=c200 pio_base=2000 len=128 index=5 first_map=0


How can i fix this? 
Is the patch hvmloader already applied in xen-unstable4.2?
Is there any difference between using pci-stub instead of pciback?

With these 2 patches applied I cannot run the virtual machine neither with
gfx_passthru = 0, but without those patches i was able to do it and was able
to see the Nvidia Card inside Windows but with error code43 and a yellow
exclamation symbol...

Any help would be welcome, thanks.




-----
JavMV
--
View this message in context: http://xen.1045712.n5.nabble.com/VGA-passthrough-on-unstable-tp4372548p4384395.html
Sent from the Xen - Dev mailing list archive at Nabble.com.

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 15:20   ` Pasi Kärkkäinen
  2011-05-05 16:56     ` Liwei
@ 2011-05-09 17:14     ` Javier
  2011-05-10 13:12       ` JavMV
                         ` (2 more replies)
  1 sibling, 3 replies; 21+ messages in thread
From: Javier @ 2011-05-09 17:14 UTC (permalink / raw)
  To: xen-devel

Hi all,
Im trying to get VGA passthrough working for Nvidia GTX460 (like u), but i
can't apply any patches without errors... im following these steps:
"http://lists.xensource.com/archives/html/xen-devel/2010-05/msg00441.html"
and using those patches, but I am only able to apply the first and the third
patch succesfully while the others seems to not fit with the actual version
of xen-unstable code 
(Some Hunks say succeed and some say failed, for example the 4th patch
(hvmloader.patch) returns
   # patch -p0 < hvmloader.patch
  patching file tools/firmware/hvmloader/hvmloader.c
  Hunk #1 succeeded at 114 with fuzz 2 (offset -1 lines).
  Hunk #2 FAILED at 220.
  Hunk #3 succeeded at 436 (offset -257 lines).
  1 out of 3 hunks FAILED -- saving rejects to file
tools/firmware/hvmloader/hvmloader.c.rej

the path "makefile" neither works.. )
 
Also i have tried to use the patches that Mr Teo En Ming attach at the end
of this post
"http://lists.xensource.com/archives/html/xen-devel/2009-08/msg01176.html"
but I've got similarly errors..

Could you post how do you proceed to make this patches work? Did u make your
own patches?
I really need to make this work.. 

Thank you for your time.



Pasi Kärkkäinen wrote:
> 
> On Thu, May 05, 2011 at 07:33:46PM +0800, Liwei wrote:
>> (Pardon me if I broke any rules or this post doesn't belong to this list)
>> 
>> I forward patched yesterday's copy of the unstable repo in an attempt to
>> get VGA passthrough working for a Nvidia GTX460 on a HVM DomU.
>> (Surprisingly, it wasn't hard at all to get the patches in - getting
>> them to work is another ongoing story)
>> 
>> The patches were based on this post:
>> http://wiki.xensource.com/xenwiki/XenVGAPassthrough
>> 
>> I dumped the card's BIOS using nvtool as per the post's instructions.
>> The only major change was that the BIOS ROM setup code was shifted
>> into its own file and some adjustment was needed for that. I'll create
>> a new patchset once I get this fully working. I also hope to push this
>> into being accepted by the devs for future releases by allowing the
>> user to configure this option and provide his own BIOS dump (instead
>> of hardcoding everything).
>> 
> 
> Being able to specify which vgabios file to load would be great..
> Feel free to send patches!
> 
> 
>> My card doesn't seem to support FLR, since xend complains about being
>> unable to reset the device.
>> 
>> With or without the
>> qemu-claim-cycle-for-secondary-gfx-passthrough.patch, the secondary
>> graphics card does not show anything at all (maybe because it is
>> behind a PCI-E bridge?), and xl list seems to show the guest consuming
>> all CPU resources.
>> 
>> However, using the primary graphics card, again with or without the
>> secondary passthrough patch, it actually managed to partially work
>> booting up the Windows 7 install. It manages to reach the pulsating
>> windows logo before BSOD-ing with 0x0000000A (IRQ_NOT_LESS_OR_EQUAL).
>> Meanwhile, the logs show a lot of:
>> 
>>    pt_pci_read_config: Error: Failed to read register with invalid
>> access size alignment. [00:05.0][Offset:0eh][Length:4]
>>    pt_pci_read_config: Error: Failed to read register with invalid
>> access size alignment. [00:06.0][Offset:0eh][Length:4]
>> 
> 
> Hmm.. 
> 
> So did you apply the vBar == pBar patches ?
> Did you modify them to fit your hardware? 
> 
> -- Pasi
> 
> 
>> Reduced the amount of allocated memory to 4096MB will introduce video
>> corruption in the pulsating logo, followed by the same BSOD.
>> 
>> Reducing the amount of allocated memory to below 2048MB or 1024MB will
>> cause a 0x000000A5 BSOD (BIOS ACPI not compliant).
>> 
>> Attempting to boot the same setup (with 8192MB of memory) with vCPU
>> set to 8 produced slightly different behaviour. Qemu seems to crash
>> and reboot a few seconds after the pulsating windows logo appears
>> (earlier than before the BSOD appeared before). At this point, it
>> should be noted that the 8 vCPU and 8192MB configuration worked with
>> 4.0. I couldn't test it in the patched unstable because VNC will only
>> produce a white screen (wrong VGA BIOS executed?).
>> 
>> Attempting to boot Ubuntu also produced similar results, except the
>> log now shows errors similar to (I did not copy out the log before
>> they were overwritten):
>> 
>>    Error: Failed to write register with invalid access size
>> 
>> The boot up seems to fail at trying to read from the emulated SATA
>> drive though, something about interrupt lost, and keeps on trying
>> again and again forever.
>> 
>> With the above tests, I also unscientifically fiddled around with the
>> pci_power_mgmt, pci_msitranslate, hap, hpet, pae, apic, acpi and
>> viridian toggleable settings.
>> 
>> I made no functional changes to the patches however, so maybe there
>> was something that I had to change in order to customise it for my
>> card. It'd be great if someone points that out to me if it is true.
>> 
>> I cannot use my USB keyboard and mouse at all in all my tests with
>> unstable, USB controller is passed in. USB works on 4.0 in the windows
>> installer, but I haven't tested them before the installer boots, so it
>> may be possible that passthrough is broken with my setup (does the
>> BIOS initialise USB peripherals for use during boot?).
>> 
>> So how should I proceed on from here?
>> 
>> Setup details as follows:
>> 
>> EVGA P55 Classified
>> Intel i7 860
>> 8GB Memory
>> 2x Palit Nvidia GTX460 (Primary and secondary)
>> 
>> Debian Squeeze
>> Dom0 is 2.6.32+29 (From repo)
>> 
>> PCI devices (Only those bound to xen_pciback are listed):
>> (It should be noted that except for the primary GFX, all other devices
>> are behind a NF200 PCI-E bridge)
>> 0b:00.0 - Secondary GFX
>> 0b:00.1 - Secondary GFX audio
>> 01:00.0 - Primary GFX
>> 01:00.1 - Primary GFX audio
>> 0e:00.0 - Multiport network card
>> 04:00.0 - Singleport network card
>> 00:1a.0 - USB2 root
>> 00:1b.0 - HD audio device
>> 00:1d.0 - USB2 root
>> 
>> PCI devices combinations tested (in each case, the audio is
>> passthroughed with the GFX):
>> (OT: Why doesn't multi-device BDF binding work on xen_pciback?)
>> Primary GFX only
>> Secondary GFX only
>> Primary GFX + Secondary GFX
>> Primary GFX + others
>> Secondary GFX + others
>> Primary GFX + Secondary GFX + others
>> 
>> Attached: Log files produced by xend and qemu and config files
>> (Sorry that only one set of logs are available, wasn't thinking
>> properly when executing rm *.log)
> 
> 
> 
> 
> 
>> _______________________________________________
>> Xen-devel mailing list
>> Xen-devel@lists.xensource.com
>> http://lists.xensource.com/xen-devel
> 
> 
> _______________________________________________
> Xen-devel mailing list
> Xen-devel@lists.xensource.com
> http://lists.xensource.com/xen-devel
> 


--
View this message in context: http://xen.1045712.n5.nabble.com/VGA-passthrough-on-unstable-tp4372548p4382411.html
Sent from the Xen - Dev mailing list archive at Nabble.com.

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 18:49                   ` Pasi Kärkkäinen
@ 2011-05-09  0:26                     ` Liwei
  0 siblings, 0 replies; 21+ messages in thread
From: Liwei @ 2011-05-09  0:26 UTC (permalink / raw)
  To: Pasi Kärkkäinen; +Cc: xen-devel

On 6 May 2011 02:49, Pasi Kärkkäinen <pasik@iki.fi> wrote:
> Ok, so maybe you should rebuild a kernel with PASS instead of VPCI ..
> (to get matching PCI IDs in the VM).

Back with a newly compiled 2.6.32.39 from Jeremy's 2.6.32.x branch.
(Was stuck for days trying to get Konrad's 2.6.39 branch to work as
dom0 only to realise that its not supported yet) Also upgraded xen to
yesterday's revision.

Nothing seems to have changed. I'm still getting:
pt_pci_read_config: Error: Failed to read register with invalid access
size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access
size alignment. [00:06.0][Offset:0eh][Length:4]

The PCI IDs did not change even though I've switched PCIDEV to pass:
# cat /boot/config-2.6.32.39 |grep PCIDEV
CONFIG_XEN_PCIDEV_FRONTEND=y
CONFIG_XEN_PCIDEV_BACKEND=y
# CONFIG_XEN_PCIDEV_BACKEND_VPCI is not set
CONFIG_XEN_PCIDEV_BACKEND_PASS=y
# CONFIG_XEN_PCIDEV_BACKEND_SLOT is not set
# CONFIG_XEN_PCIDEV_BACKEND_CONTROLLER is not set
# CONFIG_XEN_PCIDEV_BE_DEBUG is not set

With the following config, I managed to prevent the vm from
continuously rebooting, but it just stays at the pulsating windows
logo doing nothing:
W7Test                                       9  4087     1     -b----      37.9

builder='hvm'
memory = 4096
vcpus = 1
shadow_memory = 32
name = "W7Test"
vif = [ 'type=ioemu, bridge=xenbr0' ]
viridian = 1
acpi = 1
apic = 1
pae = 1
hpet = 1
hap = 1
disk = [ 'phy:/dev/mapper/VMStore-W7Test,hdb,w', 'file:/w7.iso,hda:cdrom,r' ]
boot="cd"
sdl=0
vnc=1
vncconsole=1
vncpasswd=''
serial='pty'
usbdevice='tablet'
gfx_passthru = 1
pci = [ '01:00.0', '01:00.1' ]
pci_msitranslate = 1

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 18:42                 ` Liwei
@ 2011-05-05 18:49                   ` Pasi Kärkkäinen
  2011-05-09  0:26                     ` Liwei
  0 siblings, 1 reply; 21+ messages in thread
From: Pasi Kärkkäinen @ 2011-05-05 18:49 UTC (permalink / raw)
  To: Liwei; +Cc: xen-devel

On Fri, May 06, 2011 at 02:42:33AM +0800, Liwei wrote:
> On 6 May 2011 02:33, Pasi Kärkkäinen <pasik@iki.fi> wrote:
> >
> > Ok. So pci=resource_alignment= should do it..
> >
> 
> Should it produce anything in the logs?
> 

Not sure.

> >
> > Uhm, I meant the CONFIG_XEN_PCIDEV_BACKEND_PASS,
> > CONFIG_XEN_PCIDEV_BACKEND_VPCI etc in kernel .config..
> >
> > If it's VPCI then the PCI ID's in the VM are different from dom0..
> > if it's PASS then PCI IDs will be the same.
> >
> > -- Pasi
> >
> 
> I have this, so I assume that means that the IDs are different? So
> those statements are referring to the graphics card and its audio
> device. With the pci=resource_alignment option, this is still
> happening, what gives?
> 

pci=resource_alignment has nothing to do with changing PCI IDs.

> CONFIG_XEN_PCIDEV_BACKEND_VPCI=y
> # CONFIG_XEN_PCIDEV_BACKEND_PASS is not set
> # CONFIG_XEN_PCIDEV_BACKEND_SLOT is not set
> # CONFIG_XEN_PCIDEV_BACKEND_CONTROLLER is not set

Ok, so maybe you should rebuild a kernel with PASS instead of VPCI ..
(to get matching PCI IDs in the VM).

-- Pasi

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 18:33               ` Pasi Kärkkäinen
@ 2011-05-05 18:42                 ` Liwei
  2011-05-05 18:49                   ` Pasi Kärkkäinen
  0 siblings, 1 reply; 21+ messages in thread
From: Liwei @ 2011-05-05 18:42 UTC (permalink / raw)
  To: Pasi Kärkkäinen; +Cc: xen-devel

On 6 May 2011 02:33, Pasi Kärkkäinen <pasik@iki.fi> wrote:
>
> Ok. So pci=resource_alignment= should do it..
>

Should it produce anything in the logs?

>
> Uhm, I meant the CONFIG_XEN_PCIDEV_BACKEND_PASS,
> CONFIG_XEN_PCIDEV_BACKEND_VPCI etc in kernel .config..
>
> If it's VPCI then the PCI ID's in the VM are different from dom0..
> if it's PASS then PCI IDs will be the same.
>
> -- Pasi
>

I have this, so I assume that means that the IDs are different? So
those statements are referring to the graphics card and its audio
device. With the pci=resource_alignment option, this is still
happening, what gives?

CONFIG_XEN_PCIDEV_BACKEND_VPCI=y
# CONFIG_XEN_PCIDEV_BACKEND_PASS is not set
# CONFIG_XEN_PCIDEV_BACKEND_SLOT is not set
# CONFIG_XEN_PCIDEV_BACKEND_CONTROLLER is not set

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 18:28             ` Liwei
@ 2011-05-05 18:33               ` Pasi Kärkkäinen
  2011-05-05 18:42                 ` Liwei
  0 siblings, 1 reply; 21+ messages in thread
From: Pasi Kärkkäinen @ 2011-05-05 18:33 UTC (permalink / raw)
  To: Liwei; +Cc: xen-devel

On Fri, May 06, 2011 at 02:28:29AM +0800, Liwei wrote:
> On 6 May 2011 02:12, Pasi Kärkkäinen <pasik@iki.fi> wrote:
> >
> > IMHO it's fine to require some pre-processing by the user,
> > since it's pretty manual step anyway to get the image captured from the card..
> >
> 
> Was thinking of that too, that'll simplify the patch to just the
> configuration and binary loading.
> 

Indeed.

> >
> > So I assume you've read:
> > http://wiki.xen.org/xenwiki/XenPCIpassthrough
> >
> > Which dom0 kernel are you using? is pciback a module, or built-in?
> >
> 
> Yeah, I've read that and tried both the pci=resource_alignment and
> reassigndev options. Unless it doesn't produce any obvious log entries
> in dmesg, I don't think they did anything.
> 
> That'd be 2.6.32-5-xen-amd64 from the debian squeeze repository, using
> the builtin xen_pciback.
> 

Ok. So pci=resource_alignment= should do it..


> >> Come to think of it, why are there errors for BDF 00:05.0 and 00:06.0
> >> when only 01:00.0 and 01:00.1 is passed in?
> >>
> >
> > What pciback mode are you using?
> >
> > -- Pasi
> >
> 
> I have xen-pciback.permissive in my boot argument, so I assume that
> means its permissive?

Uhm, I meant the CONFIG_XEN_PCIDEV_BACKEND_PASS, 
CONFIG_XEN_PCIDEV_BACKEND_VPCI etc in kernel .config..

If it's VPCI then the PCI ID's in the VM are different from dom0..
if it's PASS then PCI IDs will be the same.

-- Pasi

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 18:12           ` Pasi Kärkkäinen
@ 2011-05-05 18:28             ` Liwei
  2011-05-05 18:33               ` Pasi Kärkkäinen
  0 siblings, 1 reply; 21+ messages in thread
From: Liwei @ 2011-05-05 18:28 UTC (permalink / raw)
  To: Pasi Kärkkäinen; +Cc: xen-devel

On 6 May 2011 02:12, Pasi Kärkkäinen <pasik@iki.fi> wrote:
>
> IMHO it's fine to require some pre-processing by the user,
> since it's pretty manual step anyway to get the image captured from the card..
>

Was thinking of that too, that'll simplify the patch to just the
configuration and binary loading.

>
> So I assume you've read:
> http://wiki.xen.org/xenwiki/XenPCIpassthrough
>
> Which dom0 kernel are you using? is pciback a module, or built-in?
>

Yeah, I've read that and tried both the pci=resource_alignment and
reassigndev options. Unless it doesn't produce any obvious log entries
in dmesg, I don't think they did anything.

That'd be 2.6.32-5-xen-amd64 from the debian squeeze repository, using
the builtin xen_pciback.

>> Come to think of it, why are there errors for BDF 00:05.0 and 00:06.0
>> when only 01:00.0 and 01:00.1 is passed in?
>>
>
> What pciback mode are you using?
>
> -- Pasi
>

I have xen-pciback.permissive in my boot argument, so I assume that
means its permissive?

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 17:59         ` Liwei
@ 2011-05-05 18:12           ` Pasi Kärkkäinen
  2011-05-05 18:28             ` Liwei
  0 siblings, 1 reply; 21+ messages in thread
From: Pasi Kärkkäinen @ 2011-05-05 18:12 UTC (permalink / raw)
  To: Liwei; +Cc: xen-devel

On Fri, May 06, 2011 at 01:59:29AM +0800, Liwei wrote:
> On 6 May 2011 01:06, Pasi Kärkkäinen <pasik@iki.fi> wrote:
> >
> > Yeah I didn't mean you to post the actual BIOS image file,
> > only the Xen patches that support loading the BIOS image from specified file.
> > (so that people don't have to hardcode the BIOS image to custom binaries).
> >
> 
> That I have not started and will probably need some work integrating a
> hex converter (or maybe require the user to supply the converted
> binary) and finding out how xen/qemu handles the configuration files.
> 

Ok. 

IMHO it's fine to require some pre-processing by the user, 
since it's pretty manual step anyway to get the image captured from the card..

> >
> > I think other people who tried those patches (and got them working)
> > had to modify the vbar/pbar ranges to match their hardware..
> >
> > btw the error message above mentions alignment.. did you try the
> > alignment option for xen-pciback?
> >
> > -- Pasi
> >
> >
> 
> Where do I modify the ranges? Is it the bunch of DWordMemory macros in
> dsdt.asl? And how do I determine the range that I must use?
> 

I'm not sure, unfortunately. I haven't looked at the patches.

> I did a quick test by appending pci=resource_alignment=[all the
> pciback devices] to my boot command, it didn't seem to trigger any
> changes in my bootlog nor the guest booting, is that the right option?
> 

So I assume you've read:
http://wiki.xen.org/xenwiki/XenPCIpassthrough

Which dom0 kernel are you using? is pciback a module, or built-in? 

> Come to think of it, why are there errors for BDF 00:05.0 and 00:06.0
> when only 01:00.0 and 01:00.1 is passed in?
>

What pciback mode are you using? 

-- Pasi

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 17:06       ` Pasi Kärkkäinen
@ 2011-05-05 17:59         ` Liwei
  2011-05-05 18:12           ` Pasi Kärkkäinen
  0 siblings, 1 reply; 21+ messages in thread
From: Liwei @ 2011-05-05 17:59 UTC (permalink / raw)
  To: Pasi Kärkkäinen; +Cc: xen-devel

On 6 May 2011 01:06, Pasi Kärkkäinen <pasik@iki.fi> wrote:
>
> Yeah I didn't mean you to post the actual BIOS image file,
> only the Xen patches that support loading the BIOS image from specified file.
> (so that people don't have to hardcode the BIOS image to custom binaries).
>

That I have not started and will probably need some work integrating a
hex converter (or maybe require the user to supply the converted
binary) and finding out how xen/qemu handles the configuration files.

>
> I think other people who tried those patches (and got them working)
> had to modify the vbar/pbar ranges to match their hardware..
>
> btw the error message above mentions alignment.. did you try the
> alignment option for xen-pciback?
>
> -- Pasi
>
>

Where do I modify the ranges? Is it the bunch of DWordMemory macros in
dsdt.asl? And how do I determine the range that I must use?

I did a quick test by appending pci=resource_alignment=[all the
pciback devices] to my boot command, it didn't seem to trigger any
changes in my bootlog nor the guest booting, is that the right option?

Come to think of it, why are there errors for BDF 00:05.0 and 00:06.0
when only 01:00.0 and 01:00.1 is passed in?

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 16:56     ` Liwei
@ 2011-05-05 17:06       ` Pasi Kärkkäinen
  2011-05-05 17:59         ` Liwei
  0 siblings, 1 reply; 21+ messages in thread
From: Pasi Kärkkäinen @ 2011-05-05 17:06 UTC (permalink / raw)
  To: Liwei; +Cc: xen-devel

On Fri, May 06, 2011 at 12:56:30AM +0800, Liwei wrote:
> On 5 May 2011 23:20, Pasi Kärkkäinen <pasik@iki.fi> wrote:
> >
> > Being able to specify which vgabios file to load would be great..
> > Feel free to send patches!
> 
> I dumped the BIOS of my Palit Nvidia GTX480 card with the nvdump tool.
> Not sure if its legal to post it online though. Will send the patches
> when there's substantial progress.
> 

Yeah I didn't mean you to post the actual BIOS image file,
only the Xen patches that support loading the BIOS image from specified file.
(so that people don't have to hardcode the BIOS image to custom binaries).


> >
> >
> >> However, using the primary graphics card, again with or without the
> >> secondary passthrough patch, it actually managed to partially work
> >> booting up the Windows 7 install. It manages to reach the pulsating
> >> windows logo before BSOD-ing with 0x0000000A (IRQ_NOT_LESS_OR_EQUAL).
> >> Meanwhile, the logs show a lot of:
> >>
> >>    pt_pci_read_config: Error: Failed to read register with invalid
> >> access size alignment. [00:05.0][Offset:0eh][Length:4]
> >>    pt_pci_read_config: Error: Failed to read register with invalid
> >> access size alignment. [00:06.0][Offset:0eh][Length:4]
> >>
> >
> > Hmm..
> >
> > So did you apply the vBar == pBar patches ?
> > Did you modify them to fit your hardware?
> >
> > -- Pasi
> 
> http://markmail.org/message/7gb7djbmlaxruaai
> 
> The patch that I use is based on Weidong's pBAR==vBAR patch. From what
> I hear it automatically remaps any vBAR access? I'm not familiar with
> low level hardware architecture, so I'd need some prodding to
> understand what's going on in the patched code.
> 
> So where do I modify them to fit my hardware?

I think other people who tried those patches (and got them working)
had to modify the vbar/pbar ranges to match their hardware..

btw the error message above mentions alignment.. did you try the 
alignment option for xen-pciback? 

-- Pasi

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 15:20   ` Pasi Kärkkäinen
@ 2011-05-05 16:56     ` Liwei
  2011-05-05 17:06       ` Pasi Kärkkäinen
  2011-05-09 17:14     ` Javier
  1 sibling, 1 reply; 21+ messages in thread
From: Liwei @ 2011-05-05 16:56 UTC (permalink / raw)
  To: Pasi Kärkkäinen; +Cc: xen-devel

On 5 May 2011 23:20, Pasi Kärkkäinen <pasik@iki.fi> wrote:
>
> Being able to specify which vgabios file to load would be great..
> Feel free to send patches!

I dumped the BIOS of my Palit Nvidia GTX480 card with the nvdump tool.
Not sure if its legal to post it online though. Will send the patches
when there's substantial progress.

>
>
>> However, using the primary graphics card, again with or without the
>> secondary passthrough patch, it actually managed to partially work
>> booting up the Windows 7 install. It manages to reach the pulsating
>> windows logo before BSOD-ing with 0x0000000A (IRQ_NOT_LESS_OR_EQUAL).
>> Meanwhile, the logs show a lot of:
>>
>>    pt_pci_read_config: Error: Failed to read register with invalid
>> access size alignment. [00:05.0][Offset:0eh][Length:4]
>>    pt_pci_read_config: Error: Failed to read register with invalid
>> access size alignment. [00:06.0][Offset:0eh][Length:4]
>>
>
> Hmm..
>
> So did you apply the vBar == pBar patches ?
> Did you modify them to fit your hardware?
>
> -- Pasi

http://markmail.org/message/7gb7djbmlaxruaai

The patch that I use is based on Weidong's pBAR==vBAR patch. From what
I hear it automatically remaps any vBAR access? I'm not familiar with
low level hardware architecture, so I'd need some prodding to
understand what's going on in the patched code.

So where do I modify them to fit my hardware?

^ permalink raw reply	[flat|nested] 21+ messages in thread

* Re: VGA passthrough on unstable
  2011-05-05 11:33 ` Liwei
@ 2011-05-05 15:20   ` Pasi Kärkkäinen
  2011-05-05 16:56     ` Liwei
  2011-05-09 17:14     ` Javier
  0 siblings, 2 replies; 21+ messages in thread
From: Pasi Kärkkäinen @ 2011-05-05 15:20 UTC (permalink / raw)
  To: Liwei; +Cc: xen-devel

On Thu, May 05, 2011 at 07:33:46PM +0800, Liwei wrote:
> (Pardon me if I broke any rules or this post doesn't belong to this list)
> 
> I forward patched yesterday's copy of the unstable repo in an attempt to
> get VGA passthrough working for a Nvidia GTX460 on a HVM DomU.
> (Surprisingly, it wasn't hard at all to get the patches in - getting
> them to work is another ongoing story)
> 
> The patches were based on this post:
> http://wiki.xensource.com/xenwiki/XenVGAPassthrough
> 
> I dumped the card's BIOS using nvtool as per the post's instructions.
> The only major change was that the BIOS ROM setup code was shifted
> into its own file and some adjustment was needed for that. I'll create
> a new patchset once I get this fully working. I also hope to push this
> into being accepted by the devs for future releases by allowing the
> user to configure this option and provide his own BIOS dump (instead
> of hardcoding everything).
> 

Being able to specify which vgabios file to load would be great..
Feel free to send patches!


> My card doesn't seem to support FLR, since xend complains about being
> unable to reset the device.
> 
> With or without the
> qemu-claim-cycle-for-secondary-gfx-passthrough.patch, the secondary
> graphics card does not show anything at all (maybe because it is
> behind a PCI-E bridge?), and xl list seems to show the guest consuming
> all CPU resources.
> 
> However, using the primary graphics card, again with or without the
> secondary passthrough patch, it actually managed to partially work
> booting up the Windows 7 install. It manages to reach the pulsating
> windows logo before BSOD-ing with 0x0000000A (IRQ_NOT_LESS_OR_EQUAL).
> Meanwhile, the logs show a lot of:
> 
>    pt_pci_read_config: Error: Failed to read register with invalid
> access size alignment. [00:05.0][Offset:0eh][Length:4]
>    pt_pci_read_config: Error: Failed to read register with invalid
> access size alignment. [00:06.0][Offset:0eh][Length:4]
> 

Hmm.. 

So did you apply the vBar == pBar patches ?
Did you modify them to fit your hardware? 

-- Pasi


> Reduced the amount of allocated memory to 4096MB will introduce video
> corruption in the pulsating logo, followed by the same BSOD.
> 
> Reducing the amount of allocated memory to below 2048MB or 1024MB will
> cause a 0x000000A5 BSOD (BIOS ACPI not compliant).
> 
> Attempting to boot the same setup (with 8192MB of memory) with vCPU
> set to 8 produced slightly different behaviour. Qemu seems to crash
> and reboot a few seconds after the pulsating windows logo appears
> (earlier than before the BSOD appeared before). At this point, it
> should be noted that the 8 vCPU and 8192MB configuration worked with
> 4.0. I couldn't test it in the patched unstable because VNC will only
> produce a white screen (wrong VGA BIOS executed?).
> 
> Attempting to boot Ubuntu also produced similar results, except the
> log now shows errors similar to (I did not copy out the log before
> they were overwritten):
> 
>    Error: Failed to write register with invalid access size
> 
> The boot up seems to fail at trying to read from the emulated SATA
> drive though, something about interrupt lost, and keeps on trying
> again and again forever.
> 
> With the above tests, I also unscientifically fiddled around with the
> pci_power_mgmt, pci_msitranslate, hap, hpet, pae, apic, acpi and
> viridian toggleable settings.
> 
> I made no functional changes to the patches however, so maybe there
> was something that I had to change in order to customise it for my
> card. It'd be great if someone points that out to me if it is true.
> 
> I cannot use my USB keyboard and mouse at all in all my tests with
> unstable, USB controller is passed in. USB works on 4.0 in the windows
> installer, but I haven't tested them before the installer boots, so it
> may be possible that passthrough is broken with my setup (does the
> BIOS initialise USB peripherals for use during boot?).
> 
> So how should I proceed on from here?
> 
> Setup details as follows:
> 
> EVGA P55 Classified
> Intel i7 860
> 8GB Memory
> 2x Palit Nvidia GTX460 (Primary and secondary)
> 
> Debian Squeeze
> Dom0 is 2.6.32+29 (From repo)
> 
> PCI devices (Only those bound to xen_pciback are listed):
> (It should be noted that except for the primary GFX, all other devices
> are behind a NF200 PCI-E bridge)
> 0b:00.0 - Secondary GFX
> 0b:00.1 - Secondary GFX audio
> 01:00.0 - Primary GFX
> 01:00.1 - Primary GFX audio
> 0e:00.0 - Multiport network card
> 04:00.0 - Singleport network card
> 00:1a.0 - USB2 root
> 00:1b.0 - HD audio device
> 00:1d.0 - USB2 root
> 
> PCI devices combinations tested (in each case, the audio is
> passthroughed with the GFX):
> (OT: Why doesn't multi-device BDF binding work on xen_pciback?)
> Primary GFX only
> Secondary GFX only
> Primary GFX + Secondary GFX
> Primary GFX + others
> Secondary GFX + others
> Primary GFX + Secondary GFX + others
> 
> Attached: Log files produced by xend and qemu and config files
> (Sorry that only one set of logs are available, wasn't thinking
> properly when executing rm *.log)





> _______________________________________________
> Xen-devel mailing list
> Xen-devel@lists.xensource.com
> http://lists.xensource.com/xen-devel

^ permalink raw reply	[flat|nested] 21+ messages in thread

* VGA passthrough on unstable
  2011-05-03  6:29 Liwei
  2011-05-03 15:20 ` Liwei
@ 2011-05-05 11:33 ` Liwei
  2011-05-05 15:20   ` Pasi Kärkkäinen
  1 sibling, 1 reply; 21+ messages in thread
From: Liwei @ 2011-05-05 11:33 UTC (permalink / raw)
  To: xen-devel

[-- Attachment #1: Type: text/plain, Size: 4725 bytes --]

(Pardon me if I broke any rules or this post doesn't belong to this list)

I forward patched yesterday's copy of the unstable repo in an attempt to
get VGA passthrough working for a Nvidia GTX460 on a HVM DomU.
(Surprisingly, it wasn't hard at all to get the patches in - getting
them to work is another ongoing story)

The patches were based on this post:
http://wiki.xensource.com/xenwiki/XenVGAPassthrough

I dumped the card's BIOS using nvtool as per the post's instructions.
The only major change was that the BIOS ROM setup code was shifted
into its own file and some adjustment was needed for that. I'll create
a new patchset once I get this fully working. I also hope to push this
into being accepted by the devs for future releases by allowing the
user to configure this option and provide his own BIOS dump (instead
of hardcoding everything).

My card doesn't seem to support FLR, since xend complains about being
unable to reset the device.

With or without the
qemu-claim-cycle-for-secondary-gfx-passthrough.patch, the secondary
graphics card does not show anything at all (maybe because it is
behind a PCI-E bridge?), and xl list seems to show the guest consuming
all CPU resources.

However, using the primary graphics card, again with or without the
secondary passthrough patch, it actually managed to partially work
booting up the Windows 7 install. It manages to reach the pulsating
windows logo before BSOD-ing with 0x0000000A (IRQ_NOT_LESS_OR_EQUAL).
Meanwhile, the logs show a lot of:

   pt_pci_read_config: Error: Failed to read register with invalid
access size alignment. [00:05.0][Offset:0eh][Length:4]
   pt_pci_read_config: Error: Failed to read register with invalid
access size alignment. [00:06.0][Offset:0eh][Length:4]

Reduced the amount of allocated memory to 4096MB will introduce video
corruption in the pulsating logo, followed by the same BSOD.

Reducing the amount of allocated memory to below 2048MB or 1024MB will
cause a 0x000000A5 BSOD (BIOS ACPI not compliant).

Attempting to boot the same setup (with 8192MB of memory) with vCPU
set to 8 produced slightly different behaviour. Qemu seems to crash
and reboot a few seconds after the pulsating windows logo appears
(earlier than before the BSOD appeared before). At this point, it
should be noted that the 8 vCPU and 8192MB configuration worked with
4.0. I couldn't test it in the patched unstable because VNC will only
produce a white screen (wrong VGA BIOS executed?).

Attempting to boot Ubuntu also produced similar results, except the
log now shows errors similar to (I did not copy out the log before
they were overwritten):

   Error: Failed to write register with invalid access size

The boot up seems to fail at trying to read from the emulated SATA
drive though, something about interrupt lost, and keeps on trying
again and again forever.

With the above tests, I also unscientifically fiddled around with the
pci_power_mgmt, pci_msitranslate, hap, hpet, pae, apic, acpi and
viridian toggleable settings.

I made no functional changes to the patches however, so maybe there
was something that I had to change in order to customise it for my
card. It'd be great if someone points that out to me if it is true.

I cannot use my USB keyboard and mouse at all in all my tests with
unstable, USB controller is passed in. USB works on 4.0 in the windows
installer, but I haven't tested them before the installer boots, so it
may be possible that passthrough is broken with my setup (does the
BIOS initialise USB peripherals for use during boot?).

So how should I proceed on from here?

Setup details as follows:

EVGA P55 Classified
Intel i7 860
8GB Memory
2x Palit Nvidia GTX460 (Primary and secondary)

Debian Squeeze
Dom0 is 2.6.32+29 (From repo)

PCI devices (Only those bound to xen_pciback are listed):
(It should be noted that except for the primary GFX, all other devices
are behind a NF200 PCI-E bridge)
0b:00.0 - Secondary GFX
0b:00.1 - Secondary GFX audio
01:00.0 - Primary GFX
01:00.1 - Primary GFX audio
0e:00.0 - Multiport network card
04:00.0 - Singleport network card
00:1a.0 - USB2 root
00:1b.0 - HD audio device
00:1d.0 - USB2 root

PCI devices combinations tested (in each case, the audio is
passthroughed with the GFX):
(OT: Why doesn't multi-device BDF binding work on xen_pciback?)
Primary GFX only
Secondary GFX only
Primary GFX + Secondary GFX
Primary GFX + others
Secondary GFX + others
Primary GFX + Secondary GFX + others

Attached: Log files produced by xend and qemu and config files
(Sorry that only one set of logs are available, wasn't thinking
properly when executing rm *.log)

[-- Attachment #2: ~qemu-dm-W7Test.log --]
[-- Type: application/octet-stream, Size: 8849 bytes --]

domid: 11
Using file /dev/mapper/VMStore-W7Test in read-write mode
Strip off blktap sub-type prefix to /w7.iso (drv 'aio')
Using file /w7.iso in read-only mode
Watching /local/domain/0/device-model/11/logdirty/cmd
Watching /local/domain/0/device-model/11/command
Watching /local/domain/11/cpu
char device redirected to /dev/pts/3
qemu_map_cache_init nr_buckets = 10000 size 4194304
shared page at pfn feffd
buffered io page at pfn feffb
Guest uuid = d097c238-47e6-4881-b523-dd7da3bded6a
Register xen platform.
Done register platform.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw state.
xs_read(/local/domain/0/device-model/11/xen_extended_power_mgmt): read error
medium change watch on `hda' (index: 1): aio:/w7.iso
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
Log-dirty: no command yet.
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
vcpu-set: watch node error.
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
xs_read(/local/domain/11/log-throttling): read error
qemu: ignoring not-understood drive `/local/domain/11/log-throttling'
medium change watch on `/local/domain/11/log-throttling' - unknown device, ignored
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 01:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x1:0x0.0x0
pt_register_regions: IO region registered (size=0x02000000 base_addr=0xf4000000)
pt_register_regions: IO region registered (size=0x08000000 base_addr=0xb800000c)
pt_register_regions: IO region registered (size=0x04000000 base_addr=0xc000000c)
pt_register_regions: IO region registered (size=0x00000080 base_addr=0x00004c01)
pt_register_regions: Expansion ROM registered (size=0x00080000 base_addr=0xf6280002)
pcilib: Cannot open /sys/bus/pci/devices/0000:00:02.0/config
pcilib: Cannot open /sys/bus/pci/devices/0000:00:02.0/config
setup_vga_pt: vga bios checksum is adjusted!
pt_msi_setup: msi mapped with pirq 37
pci_intx: intx=1
register_real_device: Real physical device 01:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 01:00.1 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x1:0x0.0x1
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xf627c000)
pt_msi_setup: msi mapped with pirq 36
pci_intx: intx=2
register_real_device: Real physical device 01:00.1 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 0e:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0xe:0x0.0x0
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xfbbfc004)
pt_register_regions: IO region registered (size=0x00000100 base_addr=0x0000b801)
pt_register_regions: Expansion ROM registered (size=0x00020000 base_addr=0xfbbc0000)
pt_msi_setup: msi mapped with pirq 35
pci_intx: intx=1
register_real_device: Real physical device 0e:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 04:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x4:0x0.0x0
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xf73ff004)
pt_register_regions: IO region registered (size=0x00800000 base_addr=0xf6800004)
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xf73fe004)
pt_register_regions: Expansion ROM registered (size=0x00040000 base_addr=0xf7380000)
pt_msix_init: get MSI-X table bar base f73fe000
pt_msix_init: table_off = 0, total_entries = 32
pt_msix_init: errno = 2
pt_msix_init: mapping physical MSI-X table to 7f49606d6000
pt_msi_setup: msi mapped with pirq 34
pci_intx: intx=1
register_real_device: Real physical device 04:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1a.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1a.0x0
pt_register_regions: IO region registered (size=0x00000400 base_addr=0xfbffc000)
pci_intx: intx=1
register_real_device: Real physical device 00:1a.0 registered successfuly!
IRQ type = INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1b.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1b.0x0
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xfbff8004)
pt_msi_setup: msi mapped with pirq 33
pci_intx: intx=1
register_real_device: Real physical device 00:1b.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1d.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1d.0x0
pt_register_regions: IO region registered (size=0x00000400 base_addr=0xfbff6000)
pci_intx: intx=1
register_real_device: Real physical device 00:1d.0 registered successfuly!
IRQ type = INTx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=f4000000 maddr=f4000000 type=0 len=33554432 index=0 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=b8000000 maddr=b8000000 type=8 len=134217728 index=1 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=c0000000 maddr=c0000000 type=8 len=67108864 index=3 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_ioport_map: e_phys=4c00 pio_base=4c00 len=128 index=5 first_map=1
pt_iomem_map: e_phys=f1000000 maddr=f6800000 type=0 len=8388608 index=2 first_map=1
pt_iomem_map: e_phys=f1860000 maddr=f627c000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f1864000 maddr=fbbfc000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f1868000 maddr=fbff8000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f186c000 maddr=f73ff000 type=0 len=4096 index=0 first_map=1
pt_iomem_map: e_phys=f186d000 maddr=f73fe000 type=0 len=4096 index=4 first_map=1
pt_iomem_map: e_phys=f186e000 maddr=fbffc000 type=0 len=4096 index=0 first_map=1
pt_iomem_map: e_phys=f186f000 maddr=fbff6000 type=0 len=4096 index=0 first_map=1
pt_ioport_map: e_phys=c200 pio_base=b800 len=256 index=2 first_map=1
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw state.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is ro state.
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]

[-- Attachment #3: ~W7Test.cfg --]
[-- Type: application/octet-stream, Size: 1181 bytes --]

#kernel = "/usr/lib/xen/boot/hvmloader"
builder='hvm'
memory = 8192

vcpus = 8

# Should be at least 2KB per MB of domain memory, plus a few MB per vcpu.
shadow_memory = 32
name = "W7Test"
vif = [ 'type=ioemu, bridge=xenbr0' ]
viridian = 1
acpi = 1
apic = 1
pae = 1
hpet = 1
hap = 1
disk = [ 'phy:/dev/mapper/VMStore-W7Test,hdb,w', 'file:/mnt/cdserv/w7.iso,hda:cdrom,r' ]

#device_model = "/usr/lib64/xen/bin/qemu-dm"

#-----------------------------------------------------------------------------
# boot on floppy (a), hard disk (c) or CD-ROM (d) 
# default: hard disk, cd-rom, floppy
boot="cd"
sdl=0
vnc=1
vncconsole=1
vncpasswd=''

serial='pty'
usbdevice='tablet'

gfx_passthru = 1
#pci = [ '01:00.0', '01:00.1' ]
#pci = [ '01:00.0', '01:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]

pci = [ '0b:00.0', '0b:00.1' ]
#pci = [ '0b:00.0', '0b:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]
#pci = [ '0b:00.0', '0b:00.1', '01:00.0', '01:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]

#pci = [ '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]
pci_msitranslate = 1
pci_power_mgmt = 1

[-- Attachment #4: ~xend-config.sxp --]
[-- Type: application/octet-stream, Size: 11360 bytes --]

# -*- sh -*-

#
# Xend configuration file.
#

# This example configuration is appropriate for an installation that 
# utilizes a bridged network configuration. Access to xend via http
# is disabled.  

# Commented out entries show the default for that entry, unless otherwise
# specified.

#(logfile /var/log/xen/xend.log)
#(loglevel DEBUG)

# Uncomment the line below.  Set the value to flask, acm, or dummy to 
# select a security module.

#(xsm_module_name dummy)

# The Xen-API server configuration.
#
# This value configures the ports, interfaces, and access controls for the
# Xen-API server.  Each entry in the list starts with either unix, a port
# number, or an address:port pair.  If this is "unix", then a UDP socket is
# opened, and this entry applies to that.  If it is a port, then Xend will
# listen on all interfaces on that TCP port, and if it is an address:port
# pair, then Xend will listen on the specified port, using the interface with
# the specified address.
#
# The subsequent string configures the user-based access control for the
# listener in question.  This can be one of "none" or "pam", indicating either
# that users should be allowed access unconditionally, or that the local
# Pluggable Authentication Modules configuration should be used.  If this
# string is missing or empty, then "pam" is used.
#
# The final string gives the host-based access control for that listener. If
# this is missing or empty, then all connections are accepted.  Otherwise,
# this should be a space-separated sequence of regular expressions; any host
# with a fully-qualified domain name or an IP address that matches one of
# these regular expressions will be accepted.
#
# Example: listen on TCP port 9363 on all interfaces, accepting connections
# only from machines in example.com or localhost, and allow access through
# the unix domain socket unconditionally:
#
#   (xen-api-server ((9363 pam '^localhost$ example\\.com$')
#                    (unix none)))
#
# Optionally, the TCP Xen-API server can use SSL by specifying the private
# key and certificate location:
#
#                    (9367 pam '' xen-api.key xen-api.crt)
#
# Default:
#   (xen-api-server ((unix)))


#(xend-http-server no)
#(xend-unix-server no)
#(xend-tcp-xmlrpc-server no)
#(xend-unix-xmlrpc-server yes)
#(xend-relocation-server no)
(xend-relocation-server yes)
#(xend-relocation-ssl-server no)
#(xend-udev-event-server no)

#(xend-unix-path /var/lib/xend/xend-socket)


# Address and port xend should use for the legacy TCP XMLRPC interface, 
# if xend-tcp-xmlrpc-server is set.
#(xend-tcp-xmlrpc-server-address 'localhost')
#(xend-tcp-xmlrpc-server-port 8006)

# SSL key and certificate to use for the legacy TCP XMLRPC interface.
# Setting these will mean that this port serves only SSL connections as
# opposed to plaintext ones.
#(xend-tcp-xmlrpc-server-ssl-key-file  xmlrpc.key)
#(xend-tcp-xmlrpc-server-ssl-cert-file xmlrpc.crt)


# Port xend should use for the HTTP interface, if xend-http-server is set.
#(xend-port            8000)

# Port xend should use for the relocation interface, if xend-relocation-server
# is set.
#(xend-relocation-port 8002)

# Port xend should use for the ssl relocation interface, if
# xend-relocation-ssl-server is set.
#(xend-relocation-ssl-port 8003)

# SSL key and certificate to use for the ssl relocation interface, if
# xend-relocation-ssl-server is set.
#(xend-relocation-server-ssl-key-file   xmlrpc.key)
#(xend-relocation-server-ssl-cert-file  xmlrpc.crt)

# Whether to use ssl as default when relocating.
#(xend-relocation-ssl no)

# Address xend should listen on for HTTP connections, if xend-http-server is
# set.
# Specifying 'localhost' prevents remote connections.
# Specifying the empty string '' (the default) allows all connections.
#(xend-address '')
#(xend-address localhost)

# Address xend should listen on for relocation-socket connections, if
# xend-relocation-server is set.
# Meaning and default as for xend-address above.
# Also, interface name is allowed (e.g. eth0) there to get the
# relocation address to be bound on.
#(xend-relocation-address '')

# The hosts allowed to talk to the relocation port.  If this is empty (the
# default), then all connections are allowed (assuming that the connection
# arrives on a port and interface on which we are listening; see
# xend-relocation-port and xend-relocation-address above).  Otherwise, this
# should be a space-separated sequence of regular expressions.  Any host with
# a fully-qualified domain name or an IP address that matches one of these
# regular expressions will be accepted.
#
# For example:
#  (xend-relocation-hosts-allow '^localhost$ ^.*\\.example\\.org$')
#
#(xend-relocation-hosts-allow '')
(xend-relocation-hosts-allow '^localhost$ ^localhost\\.localdomain$')

# The limit (in kilobytes) on the size of the console buffer
#(console-limit 1024)

##
# To bridge network traffic, like this:
#
# dom0: ----------------- bridge -> real eth0 -> the network
#                            |
# domU: fake eth0 -> vifN.0 -+
#
# use
#
# (network-script network-bridge)
#
# Your default ethernet device is used as the outgoing interface, by default. 
# To use a different one (e.g. eth1) use
#
# (network-script 'network-bridge netdev=eth1')
#
# The bridge is named eth0, by default (yes, really!)
#

# It is normally much better to create the bridge yourself in
# /etc/network/interfaces.  network-bridge start does nothing if you
# already have a bridge, and network-bridge stop does nothing if the
# default bridge name (normally eth0) is not a bridge.  See
# bridge-utils-interfaces(5) for full information on the syntax in
# /etc/network/interfaces, but you probably want something like this:
#    iface xenbr0 inet static
#        address [etc]
#        netmask [etc]
#        [etc]
#        bridge_ports eth0
#
# To have network-bridge create a differently-named bridge, use:
# (network-script 'network-bridge bridge=<name>')
#
# It is possible to use the network-bridge script in more complicated
# scenarios, such as having two outgoing interfaces, with two bridges, and
# two fake interfaces per guest domain.  To do things like this, write
# yourself a wrapper script, and call network-bridge from it, as appropriate.
#
#(network-script network-bridge)

# The script used to control virtual interfaces.  This can be overridden on a
# per-vif basis when creating a domain or a configuring a new vif.  The
# vif-bridge script is designed for use with the network-bridge script, or
# similar configurations.
#
# If you have overridden the bridge name using
# (network-script 'network-bridge bridge=<name>') then you may wish to do the
# same here.  The bridge name can also be set when creating a domain or
# configuring a new vif, but a value specified here would act as a default.
#
# If you are using only one bridge, the vif-bridge script will discover that,
# so there is no need to specify it explicitly.  The default is to use
# the bridge which is listed first in the output from brctl.
#
(vif-script vif-bridge)


## Use the following if network traffic is routed, as an alternative to the
# settings for bridged networking given above.
#(network-script network-route)
#(vif-script     vif-route)


## Use the following if network traffic is routed with NAT, as an alternative
# to the settings for bridged networking given above.
#(network-script network-nat)
#(vif-script     vif-nat)

# dom0-min-mem is the lowest permissible memory level (in MB) for dom0.
# This is a minimum both for auto-ballooning (as enabled by
# enable-dom0-ballooning below) and for xm mem-set when applied to dom0.
(dom0-min-mem 196)

# Whether to enable auto-ballooning of dom0 to allow domUs to be created.
# If enable-dom0-ballooning = no, dom0 will never balloon out.
(enable-dom0-ballooning yes)

# 32-bit paravirtual domains can only consume physical
# memory below 168GB. On systems with memory beyond that address,
# they'll be confined to memory below 128GB.
# Using total_available_memory (in GB) to specify the amount of memory reserved
# in the memory pool exclusively for 32-bit paravirtual domains.
# Additionally you should use dom0_mem = <-Value> as a parameter in 
# xen kernel to reserve the memory for 32-bit paravirtual domains, default 
# is "0" (0GB).  
(total_available_memory 0) 

# In SMP system, dom0 will use dom0-cpus # of CPUS
# If dom0-cpus = 0, dom0 will take all cpus available
(dom0-cpus 0)

# Whether to enable core-dumps when domains crash.
#(enable-dump no)

# The tool used for initiating virtual TPM migration
#(external-migration-tool '')

# The interface for VNC servers to listen on. Defaults
# to 127.0.0.1  To restore old 'listen everywhere' behaviour
# set this to 0.0.0.0
#(vnc-listen '127.0.0.1')

# The default password for VNC console on HVM domain.
# Empty string is no authentication.
(vncpasswd '')

# The VNC server can be told to negotiate a TLS session
# to encryption all traffic, and provide x509 cert to
# clients enabling them to verify server identity. The
# GTK-VNC widget, virt-viewer, virt-manager and VeNCrypt
# all support the VNC extension for TLS used in QEMU. The
# TightVNC/RealVNC/UltraVNC clients do not.
#
# To enable this create x509 certificates / keys in the
# directory ${XEN_CONFIG_DIR} + vnc
#
#  ca-cert.pem       - The CA certificate
#  server-cert.pem   - The Server certificate signed by the CA
#  server-key.pem    - The server private key
#
# and then uncomment this next line
# (vnc-tls 1)

# The certificate dir can be pointed elsewhere..
#
# (vnc-x509-cert-dir vnc)

# The server can be told to request & validate an x509
# certificate from the client. Only clients with a cert
# signed by the trusted CA will be able to connect. This
# is more secure the password auth alone. Passwd auth can
# used at the same time if desired. To enable client cert
# checking uncomment this:
#
# (vnc-x509-verify 1)

# The default keymap to use for the VM's virtual keyboard
# when not specififed in VM's configuration
#(keymap 'en-us')

# Script to run when the label of a resource has changed.
#(resource-label-change-script '')

# Rotation count of qemu-dm log file.
#(qemu-dm-logrotate-count 10)

# Path where persistent domain configuration is stored.
# Default is /var/lib/xend/domains/
#(xend-domains-path /var/lib/xend/domains)

# Number of seconds xend will wait for device creation and
# destruction
#(device-create-timeout 100)
#(device-destroy-timeout 100)

# When assigning device to HVM guest, we use the strict check for HVM guest by
# default. (For PV guest, we use loose check automatically if necessary.)
# When we assign device to HVM guest, if we meet with the co-assignment
# issues or the ACS issue, we could try changing the option to 'no' -- however,
# we have to realize this may incur security issue and we can't make sure the
# device assignment could really work properly even after we do this.
#(pci-passthrough-strict-check yes)
(pci-passthrough-strict-check no)

# If we have a very big scsi device configuration, start of xend is slow,
# because xend scans all the device paths to build its internal PSCSI device
# list.  If we need only a few devices for assigning to a guest, we can reduce
# the scan to this device. Set list list of device paths in same syntax like in
# command lsscsi, e.g. ('16:0:0:0' '15:0') 
# (pscsi-device-mask ('*'))


[-- Attachment #5: ~xl-W7Test.log --]
[-- Type: application/octet-stream, Size: 115 bytes --]

Waiting for domain W7Test (domid 10) to die [pid 5263]
Domain 10 is dead
Unable to get domain death info, quitting

[-- Attachment #6: Type: text/plain, Size: 138 bytes --]

_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xensource.com
http://lists.xensource.com/xen-devel

^ permalink raw reply	[flat|nested] 21+ messages in thread

* VGA passthrough on unstable
  2011-05-03  6:29 Liwei
@ 2011-05-03 15:20 ` Liwei
  2011-05-05 11:33 ` Liwei
  1 sibling, 0 replies; 21+ messages in thread
From: Liwei @ 2011-05-03 15:20 UTC (permalink / raw)
  To: xen-devel

[-- Attachment #1: Type: text/plain, Size: 4721 bytes --]

(Pardon me if I broke any rules or this post doesn't belong to this list)

I forward patched today's copy of the unstable repo in an attempt to
get VGA passthrough working for a Nvidia GTX460 on a HVM DomU.
(Surprisingly, it wasn't hard at all to get the patches in - getting
them to work is another ongoing story)

The patches were based on this post:
http://wiki.xensource.com/xenwiki/XenVGAPassthrough

I dumped the card's BIOS using nvtool as per the post's instructions.
The only major change was that the BIOS ROM setup code was shifted
into its own file and some adjustment was needed for that. I'll create
a new patchset once I get this fully working. I also hope to push this
into being accepted by the devs for future releases by allowing the
user to configure this option and provide his own BIOS dump (instead
of hardcoding everything).

My card doesn't seem to support FLR, since xend complains about being
unable to reset the device.

With or without the
qemu-claim-cycle-for-secondary-gfx-passthrough.patch, the secondary
graphics card does not show anything at all (maybe because it is
behind a PCI-E bridge?), and xl list seems to show the guest consuming
all CPU resources.

However, using the primary graphics card, again with or without the
secondary passthrough patch, it actually managed to partially work
booting up the Windows 7 install. It manages to reach the pulsating
windows logo before BSOD-ing with 0x0000000A (IRQ_NOT_LESS_OR_EQUAL).
Meanwhile, the logs show a lot of:

   pt_pci_read_config: Error: Failed to read register with invalid
access size alignment. [00:05.0][Offset:0eh][Length:4]
   pt_pci_read_config: Error: Failed to read register with invalid
access size alignment. [00:06.0][Offset:0eh][Length:4]

Reduced the amount of allocated memory to 4096MB will introduce video
corruption in the pulsating logo, followed by the same BSOD.

Reducing the amount of allocated memory to below 2048MB or 1024MB will
cause a 0x000000A5 BSOD (BIOS ACPI not compliant).

Attempting to boot the same setup (with 8192MB of memory) with vCPU
set to 8 produced slightly different behaviour. Qemu seems to crash
and reboot a few seconds after the pulsating windows logo appears
(earlier than before the BSOD appeared before). At this point, it
should be noted that the 8 vCPU and 8192MB configuration worked with
4.0. I couldn't test it in the patched unstable because VNC will only
produce a white screen (wrong VGA BIOS executed?).

Attempting to boot Ubuntu also produced similar results, except the
log now shows errors similar to (I did not copy out the log before
they were overwritten):

   Error: Failed to write register with invalid access size

The boot up seems to fail at trying to read from the emulated SATA
drive though, something about interrupt lost, and keeps on trying
again and again forever.

With the above tests, I also unscientifically fiddled around with the
pci_power_mgmt, pci_msitranslate, hap, hpet, pae, apic, acpi and
viridian toggleable settings.

I made no functional changes to the patches however, so maybe there
was something that I had to change in order to customise it for my
card. It'd be great if someone points that out to me if it is true.

I cannot use my USB keyboard and mouse at all in all my tests with
unstable, USB controller is passed in. USB works on 4.0 in the windows
installer, but I haven't tested them before the installer boots, so it
may be possible that passthrough is broken with my setup (does the
BIOS initialise USB peripherals for use during boot?).

So how should I proceed on from here?

Setup details as follows:

EVGA P55 Classified
Intel i7 860
8GB Memory
2x Palit Nvidia GTX460 (Primary and secondary)

Debian Squeeze
Dom0 is 2.6.32+29 (From repo)

PCI devices (Only those bound to xen_pciback are listed):
(It should be noted that except for the primary GFX, all other devices
are behind a NF200 PCI-E bridge)
0b:00.0 - Secondary GFX
0b:00.1 - Secondary GFX audio
01:00.0 - Primary GFX
01:00.1 - Primary GFX audio
0e:00.0 - Multiport network card
04:00.0 - Singleport network card
00:1a.0 - USB2 root
00:1b.0 - HD audio device
00:1d.0 - USB2 root

PCI devices combinations tested (in each case, the audio is
passthroughed with the GFX):
(OT: Why doesn't multi-device BDF binding work on xen_pciback?)
Primary GFX only
Secondary GFX only
Primary GFX + Secondary GFX
Primary GFX + others
Secondary GFX + others
Primary GFX + Secondary GFX + others

Attached: Log files produced by xend and qemu and config files
(Sorry that only one set of logs are available, wasn't thinking
properly when executing rm *.log)

[-- Attachment #2: ~qemu-dm-W7Test.log --]
[-- Type: application/octet-stream, Size: 8849 bytes --]

domid: 11
Using file /dev/mapper/VMStore-W7Test in read-write mode
Strip off blktap sub-type prefix to /w7.iso (drv 'aio')
Using file /w7.iso in read-only mode
Watching /local/domain/0/device-model/11/logdirty/cmd
Watching /local/domain/0/device-model/11/command
Watching /local/domain/11/cpu
char device redirected to /dev/pts/3
qemu_map_cache_init nr_buckets = 10000 size 4194304
shared page at pfn feffd
buffered io page at pfn feffb
Guest uuid = d097c238-47e6-4881-b523-dd7da3bded6a
Register xen platform.
Done register platform.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw state.
xs_read(/local/domain/0/device-model/11/xen_extended_power_mgmt): read error
medium change watch on `hda' (index: 1): aio:/w7.iso
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
Log-dirty: no command yet.
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
vcpu-set: watch node error.
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
xs_read(/local/domain/11/log-throttling): read error
qemu: ignoring not-understood drive `/local/domain/11/log-throttling'
medium change watch on `/local/domain/11/log-throttling' - unknown device, ignored
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 01:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x1:0x0.0x0
pt_register_regions: IO region registered (size=0x02000000 base_addr=0xf4000000)
pt_register_regions: IO region registered (size=0x08000000 base_addr=0xb800000c)
pt_register_regions: IO region registered (size=0x04000000 base_addr=0xc000000c)
pt_register_regions: IO region registered (size=0x00000080 base_addr=0x00004c01)
pt_register_regions: Expansion ROM registered (size=0x00080000 base_addr=0xf6280002)
pcilib: Cannot open /sys/bus/pci/devices/0000:00:02.0/config
pcilib: Cannot open /sys/bus/pci/devices/0000:00:02.0/config
setup_vga_pt: vga bios checksum is adjusted!
pt_msi_setup: msi mapped with pirq 37
pci_intx: intx=1
register_real_device: Real physical device 01:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 01:00.1 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x1:0x0.0x1
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xf627c000)
pt_msi_setup: msi mapped with pirq 36
pci_intx: intx=2
register_real_device: Real physical device 01:00.1 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 0e:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0xe:0x0.0x0
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xfbbfc004)
pt_register_regions: IO region registered (size=0x00000100 base_addr=0x0000b801)
pt_register_regions: Expansion ROM registered (size=0x00020000 base_addr=0xfbbc0000)
pt_msi_setup: msi mapped with pirq 35
pci_intx: intx=1
register_real_device: Real physical device 0e:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 04:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x4:0x0.0x0
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xf73ff004)
pt_register_regions: IO region registered (size=0x00800000 base_addr=0xf6800004)
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xf73fe004)
pt_register_regions: Expansion ROM registered (size=0x00040000 base_addr=0xf7380000)
pt_msix_init: get MSI-X table bar base f73fe000
pt_msix_init: table_off = 0, total_entries = 32
pt_msix_init: errno = 2
pt_msix_init: mapping physical MSI-X table to 7f49606d6000
pt_msi_setup: msi mapped with pirq 34
pci_intx: intx=1
register_real_device: Real physical device 04:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1a.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1a.0x0
pt_register_regions: IO region registered (size=0x00000400 base_addr=0xfbffc000)
pci_intx: intx=1
register_real_device: Real physical device 00:1a.0 registered successfuly!
IRQ type = INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1b.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1b.0x0
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xfbff8004)
pt_msi_setup: msi mapped with pirq 33
pci_intx: intx=1
register_real_device: Real physical device 00:1b.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1d.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1d.0x0
pt_register_regions: IO region registered (size=0x00000400 base_addr=0xfbff6000)
pci_intx: intx=1
register_real_device: Real physical device 00:1d.0 registered successfuly!
IRQ type = INTx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=f4000000 maddr=f4000000 type=0 len=33554432 index=0 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=b8000000 maddr=b8000000 type=8 len=134217728 index=1 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=c0000000 maddr=c0000000 type=8 len=67108864 index=3 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_ioport_map: e_phys=4c00 pio_base=4c00 len=128 index=5 first_map=1
pt_iomem_map: e_phys=f1000000 maddr=f6800000 type=0 len=8388608 index=2 first_map=1
pt_iomem_map: e_phys=f1860000 maddr=f627c000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f1864000 maddr=fbbfc000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f1868000 maddr=fbff8000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f186c000 maddr=f73ff000 type=0 len=4096 index=0 first_map=1
pt_iomem_map: e_phys=f186d000 maddr=f73fe000 type=0 len=4096 index=4 first_map=1
pt_iomem_map: e_phys=f186e000 maddr=fbffc000 type=0 len=4096 index=0 first_map=1
pt_iomem_map: e_phys=f186f000 maddr=fbff6000 type=0 len=4096 index=0 first_map=1
pt_ioport_map: e_phys=c200 pio_base=b800 len=256 index=2 first_map=1
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw state.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is ro state.
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]

[-- Attachment #3: ~W7Test.cfg --]
[-- Type: application/octet-stream, Size: 1181 bytes --]

#kernel = "/usr/lib/xen/boot/hvmloader"
builder='hvm'
memory = 8192

vcpus = 8

# Should be at least 2KB per MB of domain memory, plus a few MB per vcpu.
shadow_memory = 32
name = "W7Test"
vif = [ 'type=ioemu, bridge=xenbr0' ]
viridian = 1
acpi = 1
apic = 1
pae = 1
hpet = 1
hap = 1
disk = [ 'phy:/dev/mapper/VMStore-W7Test,hdb,w', 'file:/mnt/cdserv/w7.iso,hda:cdrom,r' ]

#device_model = "/usr/lib64/xen/bin/qemu-dm"

#-----------------------------------------------------------------------------
# boot on floppy (a), hard disk (c) or CD-ROM (d) 
# default: hard disk, cd-rom, floppy
boot="cd"
sdl=0
vnc=1
vncconsole=1
vncpasswd=''

serial='pty'
usbdevice='tablet'

gfx_passthru = 1
#pci = [ '01:00.0', '01:00.1' ]
#pci = [ '01:00.0', '01:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]

pci = [ '0b:00.0', '0b:00.1' ]
#pci = [ '0b:00.0', '0b:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]
#pci = [ '0b:00.0', '0b:00.1', '01:00.0', '01:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]

#pci = [ '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]
pci_msitranslate = 1
pci_power_mgmt = 1

[-- Attachment #4: ~xend.log --]
[-- Type: application/octet-stream, Size: 442737 bytes --]

[-- Attachment #5: ~xend-config.sxp --]
[-- Type: application/octet-stream, Size: 11360 bytes --]

# -*- sh -*-

#
# Xend configuration file.
#

# This example configuration is appropriate for an installation that 
# utilizes a bridged network configuration. Access to xend via http
# is disabled.  

# Commented out entries show the default for that entry, unless otherwise
# specified.

#(logfile /var/log/xen/xend.log)
#(loglevel DEBUG)

# Uncomment the line below.  Set the value to flask, acm, or dummy to 
# select a security module.

#(xsm_module_name dummy)

# The Xen-API server configuration.
#
# This value configures the ports, interfaces, and access controls for the
# Xen-API server.  Each entry in the list starts with either unix, a port
# number, or an address:port pair.  If this is "unix", then a UDP socket is
# opened, and this entry applies to that.  If it is a port, then Xend will
# listen on all interfaces on that TCP port, and if it is an address:port
# pair, then Xend will listen on the specified port, using the interface with
# the specified address.
#
# The subsequent string configures the user-based access control for the
# listener in question.  This can be one of "none" or "pam", indicating either
# that users should be allowed access unconditionally, or that the local
# Pluggable Authentication Modules configuration should be used.  If this
# string is missing or empty, then "pam" is used.
#
# The final string gives the host-based access control for that listener. If
# this is missing or empty, then all connections are accepted.  Otherwise,
# this should be a space-separated sequence of regular expressions; any host
# with a fully-qualified domain name or an IP address that matches one of
# these regular expressions will be accepted.
#
# Example: listen on TCP port 9363 on all interfaces, accepting connections
# only from machines in example.com or localhost, and allow access through
# the unix domain socket unconditionally:
#
#   (xen-api-server ((9363 pam '^localhost$ example\\.com$')
#                    (unix none)))
#
# Optionally, the TCP Xen-API server can use SSL by specifying the private
# key and certificate location:
#
#                    (9367 pam '' xen-api.key xen-api.crt)
#
# Default:
#   (xen-api-server ((unix)))


#(xend-http-server no)
#(xend-unix-server no)
#(xend-tcp-xmlrpc-server no)
#(xend-unix-xmlrpc-server yes)
#(xend-relocation-server no)
(xend-relocation-server yes)
#(xend-relocation-ssl-server no)
#(xend-udev-event-server no)

#(xend-unix-path /var/lib/xend/xend-socket)


# Address and port xend should use for the legacy TCP XMLRPC interface, 
# if xend-tcp-xmlrpc-server is set.
#(xend-tcp-xmlrpc-server-address 'localhost')
#(xend-tcp-xmlrpc-server-port 8006)

# SSL key and certificate to use for the legacy TCP XMLRPC interface.
# Setting these will mean that this port serves only SSL connections as
# opposed to plaintext ones.
#(xend-tcp-xmlrpc-server-ssl-key-file  xmlrpc.key)
#(xend-tcp-xmlrpc-server-ssl-cert-file xmlrpc.crt)


# Port xend should use for the HTTP interface, if xend-http-server is set.
#(xend-port            8000)

# Port xend should use for the relocation interface, if xend-relocation-server
# is set.
#(xend-relocation-port 8002)

# Port xend should use for the ssl relocation interface, if
# xend-relocation-ssl-server is set.
#(xend-relocation-ssl-port 8003)

# SSL key and certificate to use for the ssl relocation interface, if
# xend-relocation-ssl-server is set.
#(xend-relocation-server-ssl-key-file   xmlrpc.key)
#(xend-relocation-server-ssl-cert-file  xmlrpc.crt)

# Whether to use ssl as default when relocating.
#(xend-relocation-ssl no)

# Address xend should listen on for HTTP connections, if xend-http-server is
# set.
# Specifying 'localhost' prevents remote connections.
# Specifying the empty string '' (the default) allows all connections.
#(xend-address '')
#(xend-address localhost)

# Address xend should listen on for relocation-socket connections, if
# xend-relocation-server is set.
# Meaning and default as for xend-address above.
# Also, interface name is allowed (e.g. eth0) there to get the
# relocation address to be bound on.
#(xend-relocation-address '')

# The hosts allowed to talk to the relocation port.  If this is empty (the
# default), then all connections are allowed (assuming that the connection
# arrives on a port and interface on which we are listening; see
# xend-relocation-port and xend-relocation-address above).  Otherwise, this
# should be a space-separated sequence of regular expressions.  Any host with
# a fully-qualified domain name or an IP address that matches one of these
# regular expressions will be accepted.
#
# For example:
#  (xend-relocation-hosts-allow '^localhost$ ^.*\\.example\\.org$')
#
#(xend-relocation-hosts-allow '')
(xend-relocation-hosts-allow '^localhost$ ^localhost\\.localdomain$')

# The limit (in kilobytes) on the size of the console buffer
#(console-limit 1024)

##
# To bridge network traffic, like this:
#
# dom0: ----------------- bridge -> real eth0 -> the network
#                            |
# domU: fake eth0 -> vifN.0 -+
#
# use
#
# (network-script network-bridge)
#
# Your default ethernet device is used as the outgoing interface, by default. 
# To use a different one (e.g. eth1) use
#
# (network-script 'network-bridge netdev=eth1')
#
# The bridge is named eth0, by default (yes, really!)
#

# It is normally much better to create the bridge yourself in
# /etc/network/interfaces.  network-bridge start does nothing if you
# already have a bridge, and network-bridge stop does nothing if the
# default bridge name (normally eth0) is not a bridge.  See
# bridge-utils-interfaces(5) for full information on the syntax in
# /etc/network/interfaces, but you probably want something like this:
#    iface xenbr0 inet static
#        address [etc]
#        netmask [etc]
#        [etc]
#        bridge_ports eth0
#
# To have network-bridge create a differently-named bridge, use:
# (network-script 'network-bridge bridge=<name>')
#
# It is possible to use the network-bridge script in more complicated
# scenarios, such as having two outgoing interfaces, with two bridges, and
# two fake interfaces per guest domain.  To do things like this, write
# yourself a wrapper script, and call network-bridge from it, as appropriate.
#
#(network-script network-bridge)

# The script used to control virtual interfaces.  This can be overridden on a
# per-vif basis when creating a domain or a configuring a new vif.  The
# vif-bridge script is designed for use with the network-bridge script, or
# similar configurations.
#
# If you have overridden the bridge name using
# (network-script 'network-bridge bridge=<name>') then you may wish to do the
# same here.  The bridge name can also be set when creating a domain or
# configuring a new vif, but a value specified here would act as a default.
#
# If you are using only one bridge, the vif-bridge script will discover that,
# so there is no need to specify it explicitly.  The default is to use
# the bridge which is listed first in the output from brctl.
#
(vif-script vif-bridge)


## Use the following if network traffic is routed, as an alternative to the
# settings for bridged networking given above.
#(network-script network-route)
#(vif-script     vif-route)


## Use the following if network traffic is routed with NAT, as an alternative
# to the settings for bridged networking given above.
#(network-script network-nat)
#(vif-script     vif-nat)

# dom0-min-mem is the lowest permissible memory level (in MB) for dom0.
# This is a minimum both for auto-ballooning (as enabled by
# enable-dom0-ballooning below) and for xm mem-set when applied to dom0.
(dom0-min-mem 196)

# Whether to enable auto-ballooning of dom0 to allow domUs to be created.
# If enable-dom0-ballooning = no, dom0 will never balloon out.
(enable-dom0-ballooning yes)

# 32-bit paravirtual domains can only consume physical
# memory below 168GB. On systems with memory beyond that address,
# they'll be confined to memory below 128GB.
# Using total_available_memory (in GB) to specify the amount of memory reserved
# in the memory pool exclusively for 32-bit paravirtual domains.
# Additionally you should use dom0_mem = <-Value> as a parameter in 
# xen kernel to reserve the memory for 32-bit paravirtual domains, default 
# is "0" (0GB).  
(total_available_memory 0) 

# In SMP system, dom0 will use dom0-cpus # of CPUS
# If dom0-cpus = 0, dom0 will take all cpus available
(dom0-cpus 0)

# Whether to enable core-dumps when domains crash.
#(enable-dump no)

# The tool used for initiating virtual TPM migration
#(external-migration-tool '')

# The interface for VNC servers to listen on. Defaults
# to 127.0.0.1  To restore old 'listen everywhere' behaviour
# set this to 0.0.0.0
#(vnc-listen '127.0.0.1')

# The default password for VNC console on HVM domain.
# Empty string is no authentication.
(vncpasswd '')

# The VNC server can be told to negotiate a TLS session
# to encryption all traffic, and provide x509 cert to
# clients enabling them to verify server identity. The
# GTK-VNC widget, virt-viewer, virt-manager and VeNCrypt
# all support the VNC extension for TLS used in QEMU. The
# TightVNC/RealVNC/UltraVNC clients do not.
#
# To enable this create x509 certificates / keys in the
# directory ${XEN_CONFIG_DIR} + vnc
#
#  ca-cert.pem       - The CA certificate
#  server-cert.pem   - The Server certificate signed by the CA
#  server-key.pem    - The server private key
#
# and then uncomment this next line
# (vnc-tls 1)

# The certificate dir can be pointed elsewhere..
#
# (vnc-x509-cert-dir vnc)

# The server can be told to request & validate an x509
# certificate from the client. Only clients with a cert
# signed by the trusted CA will be able to connect. This
# is more secure the password auth alone. Passwd auth can
# used at the same time if desired. To enable client cert
# checking uncomment this:
#
# (vnc-x509-verify 1)

# The default keymap to use for the VM's virtual keyboard
# when not specififed in VM's configuration
#(keymap 'en-us')

# Script to run when the label of a resource has changed.
#(resource-label-change-script '')

# Rotation count of qemu-dm log file.
#(qemu-dm-logrotate-count 10)

# Path where persistent domain configuration is stored.
# Default is /var/lib/xend/domains/
#(xend-domains-path /var/lib/xend/domains)

# Number of seconds xend will wait for device creation and
# destruction
#(device-create-timeout 100)
#(device-destroy-timeout 100)

# When assigning device to HVM guest, we use the strict check for HVM guest by
# default. (For PV guest, we use loose check automatically if necessary.)
# When we assign device to HVM guest, if we meet with the co-assignment
# issues or the ACS issue, we could try changing the option to 'no' -- however,
# we have to realize this may incur security issue and we can't make sure the
# device assignment could really work properly even after we do this.
#(pci-passthrough-strict-check yes)
(pci-passthrough-strict-check no)

# If we have a very big scsi device configuration, start of xend is slow,
# because xend scans all the device paths to build its internal PSCSI device
# list.  If we need only a few devices for assigning to a guest, we can reduce
# the scan to this device. Set list list of device paths in same syntax like in
# command lsscsi, e.g. ('16:0:0:0' '15:0') 
# (pscsi-device-mask ('*'))


[-- Attachment #6: ~xend-debug.log --]
[-- Type: application/octet-stream, Size: 157998 bytes --]

Xend started at Sun May  1 15:11:32 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 15:54:38 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 16:16:42 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 16:30:15 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 16:44:48 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 17:00:37 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 17:05:29 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 17:09:44 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 01:12:00 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 02:51:00 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 02:57:52 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 03:16:45 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 03:54:54 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 03:55:27 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Tue May  3 03:07:24 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory

[-- Attachment #7: ~xl-W7Test.log --]
[-- Type: application/octet-stream, Size: 115 bytes --]

Waiting for domain W7Test (domid 10) to die [pid 5263]
Domain 10 is dead
Unable to get domain death info, quitting

[-- Attachment #8: Type: text/plain, Size: 138 bytes --]

_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xensource.com
http://lists.xensource.com/xen-devel

^ permalink raw reply	[flat|nested] 21+ messages in thread

* VGA passthrough on unstable
@ 2011-05-03  6:29 Liwei
  2011-05-03 15:20 ` Liwei
  2011-05-05 11:33 ` Liwei
  0 siblings, 2 replies; 21+ messages in thread
From: Liwei @ 2011-05-03  6:29 UTC (permalink / raw)
  To: xen-devel

[-- Attachment #1: Type: text/plain, Size: 4610 bytes --]

(Pardon me if I broke any rules or this post doesn't belong to this list)

I forward patched today's copy of the unstable repo in an attempt to
get VGA passthrough working for a Nvidia GTX460 on a HVM DomU.
(Surprisingly, it wasn't hard at all to get the patches in - getting
them to work is another ongoing story)

The patches were based on this post:
http://wiki.xensource.com/xenwiki/XenVGAPassthrough

I dumped the card's BIOS using nvtool as per the post's instructions.
The only major change was that the BIOS ROM setup code was shifted
into its own file and some adjustment was needed for that. I'll create
a new patchset once I get this fully working. I also hope to push this
into being accepted by the devs for future releases by allowing the
user to configure this option and provide his own BIOS dump (instead
of hardcoding everything).

My card doesn't seem to support FLR, since xend complains about being
unable to reset the device.

With or without the
qemu-claim-cycle-for-secondary-gfx-passthrough.patch, the secondary
graphics card does not show anything at all (maybe because it is
behind a PCI-E bridge?), and xl list seems to show the guest consuming
all CPU resources.

However, using the primary graphics card, again with or without the
secondary passthrough patch, it actually managed to partially work
booting up the Windows 7 install. It manages to reach the pulsating
windows logo before BSOD-ing with 0x0000000A (IRQ_NOT_LESS_OR_EQUAL).
Meanwhile, the logs show a lot of:

    pt_pci_read_config: Error: Failed to read register with invalid
access size alignment. [00:05.0][Offset:0eh][Length:4]
    pt_pci_read_config: Error: Failed to read register with invalid
access size alignment. [00:06.0][Offset:0eh][Length:4]

Reduced the amount of allocated memory to 4096MB will introduce video
corruption in the pulsating logo, followed by the same BSOD.

Reducing the amount of allocated memory to below 2048MB or 1024MB will
cause a 0x000000A5 BSOD (BIOS ACPI not compliant).

Attempting to boot the same setup (with 8192MB of memory) with vCPU
set to 8 produced slightly different behaviour. Qemu seems to crash
and reboot a few seconds after the pulsating windows logo appears
(earlier than before the BSOD appeared before). At this point, it
should be noted that the 8 vCPU and 8192MB configuration worked with
4.0. I couldn't test it in the patched unstable because VNC will only
produce a white screen (wrong VGA BIOS executed?).

Attempting to boot Ubuntu also produced similar results, except the
log now shows errors similar to (I did not copy out the log before
they were overwritten):

    Error: Failed to write register with invalid access size

The boot up seems to fail at trying to read from the emulated SATA
drive though, something about interrupt lost, and keeps on trying
again and again forever.

With the above tests, I also unscientifically fiddled around with the
pci_power_mgmt, pci_msitranslate, hap, hpet, pae, apic, acpi and
viridian toggleable settings.

I made no functional changes to the patches however, so maybe there
was something that I had to change in order to customise it for my
card. It'd be great if someone points that out to me if it is true.

I cannot use my USB keyboard and mouse at all in all my tests with
unstable, USB controller is passed in. USB works on 4.0 in the windows
installer, but I haven't tested them before the installer boots, so it
may be possible that passthrough is broken with my setup (does the
BIOS initialise USB peripherals for use during boot?).

So how should I proceed on from here?

Setup details as follows:

EVGA P55 Classified
Intel i7 860
8GB Memory
2x Palit Nvidia GTX460 (Primary and secondary)

Debian Squeeze
Dom0 is 2.6.32+29 (From repo)

PCI devices (Only those bound to xen_pciback are listed):
(It should be noted that except for the primary GFX, all other devices
are behind a NF200 PCI-E bridge)
0b:00.0 - Secondary GFX
0b:00.1 - Secondary GFX audio
01:00.0 - Primary GFX
01:00.1 - Primary GFX audio
0e:00.0 - Multiport network card
04:00.0 - Singleport network card
00:1a.0 - USB2 root
00:1b.0 - HD audio device
00:1d.0 - USB2 root

PCI devices combinations tested (in each case, the audio is
passthroughed with the GFX):
(OT: Why doesn't multi-device BDF binding work on xen_pciback?)
Primary GFX only
Secondary GFX only
Primary GFX + Secondary GFX
Primary GFX + others
Secondary GFX + others
Primary GFX + Secondary GFX + others

Attached: Log files produced by xend and qemu and config files
(Sorry that only one set of logs are available, wasn't thinking
properly when executing rm *.log)

[-- Attachment #2: ~qemu-dm-W7Test.log --]
[-- Type: application/octet-stream, Size: 8849 bytes --]

domid: 11
Using file /dev/mapper/VMStore-W7Test in read-write mode
Strip off blktap sub-type prefix to /w7.iso (drv 'aio')
Using file /w7.iso in read-only mode
Watching /local/domain/0/device-model/11/logdirty/cmd
Watching /local/domain/0/device-model/11/command
Watching /local/domain/11/cpu
char device redirected to /dev/pts/3
qemu_map_cache_init nr_buckets = 10000 size 4194304
shared page at pfn feffd
buffered io page at pfn feffb
Guest uuid = d097c238-47e6-4881-b523-dd7da3bded6a
Register xen platform.
Done register platform.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw state.
xs_read(/local/domain/0/device-model/11/xen_extended_power_mgmt): read error
medium change watch on `hda' (index: 1): aio:/w7.iso
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
Log-dirty: no command yet.
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
vcpu-set: watch node error.
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
xs_read(/local/domain/11/log-throttling): read error
qemu: ignoring not-understood drive `/local/domain/11/log-throttling'
medium change watch on `/local/domain/11/log-throttling' - unknown device, ignored
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
I/O request not ready: 0, ptr: 0, port: 0, data: 0, count: 0, size: 0
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 01:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x1:0x0.0x0
pt_register_regions: IO region registered (size=0x02000000 base_addr=0xf4000000)
pt_register_regions: IO region registered (size=0x08000000 base_addr=0xb800000c)
pt_register_regions: IO region registered (size=0x04000000 base_addr=0xc000000c)
pt_register_regions: IO region registered (size=0x00000080 base_addr=0x00004c01)
pt_register_regions: Expansion ROM registered (size=0x00080000 base_addr=0xf6280002)
pcilib: Cannot open /sys/bus/pci/devices/0000:00:02.0/config
pcilib: Cannot open /sys/bus/pci/devices/0000:00:02.0/config
setup_vga_pt: vga bios checksum is adjusted!
pt_msi_setup: msi mapped with pirq 37
pci_intx: intx=1
register_real_device: Real physical device 01:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 01:00.1 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x1:0x0.0x1
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xf627c000)
pt_msi_setup: msi mapped with pirq 36
pci_intx: intx=2
register_real_device: Real physical device 01:00.1 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 0e:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0xe:0x0.0x0
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xfbbfc004)
pt_register_regions: IO region registered (size=0x00000100 base_addr=0x0000b801)
pt_register_regions: Expansion ROM registered (size=0x00020000 base_addr=0xfbbc0000)
pt_msi_setup: msi mapped with pirq 35
pci_intx: intx=1
register_real_device: Real physical device 0e:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 04:00.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x4:0x0.0x0
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xf73ff004)
pt_register_regions: IO region registered (size=0x00800000 base_addr=0xf6800004)
pt_register_regions: IO region registered (size=0x00001000 base_addr=0xf73fe004)
pt_register_regions: Expansion ROM registered (size=0x00040000 base_addr=0xf7380000)
pt_msix_init: get MSI-X table bar base f73fe000
pt_msix_init: table_off = 0, total_entries = 32
pt_msix_init: errno = 2
pt_msix_init: mapping physical MSI-X table to 7f49606d6000
pt_msi_setup: msi mapped with pirq 34
pci_intx: intx=1
register_real_device: Real physical device 04:00.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1a.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1a.0x0
pt_register_regions: IO region registered (size=0x00000400 base_addr=0xfbffc000)
pci_intx: intx=1
register_real_device: Real physical device 00:1a.0 registered successfuly!
IRQ type = INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1b.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1b.0x0
pt_register_regions: IO region registered (size=0x00004000 base_addr=0xfbff8004)
pt_msi_setup: msi mapped with pirq 33
pci_intx: intx=1
register_real_device: Real physical device 00:1b.0 registered successfuly!
IRQ type = MSI-INTx
dm-command: hot insert pass-through pci dev 
register_real_device: Assigning real physical device 00:1d.0 ...
pt_iomul_init: Error: pt_iomul_init can't open file /dev/xen/pci_iomul: No such file or directory: 0x0:0x1d.0x0
pt_register_regions: IO region registered (size=0x00000400 base_addr=0xfbff6000)
pci_intx: intx=1
register_real_device: Real physical device 00:1d.0 registered successfuly!
IRQ type = INTx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=f4000000 maddr=f4000000 type=0 len=33554432 index=0 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=b8000000 maddr=b8000000 type=8 len=134217728 index=1 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_iomem_map: e_phys=c0000000 maddr=c0000000 type=8 len=67108864 index=3 first_map=1
pt_bar_reg_read: first read BARs of gfx
pt_bar_reg_read: first read BARs of gfx
pt_ioport_map: e_phys=4c00 pio_base=4c00 len=128 index=5 first_map=1
pt_iomem_map: e_phys=f1000000 maddr=f6800000 type=0 len=8388608 index=2 first_map=1
pt_iomem_map: e_phys=f1860000 maddr=f627c000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f1864000 maddr=fbbfc000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f1868000 maddr=fbff8000 type=0 len=16384 index=0 first_map=1
pt_iomem_map: e_phys=f186c000 maddr=f73ff000 type=0 len=4096 index=0 first_map=1
pt_iomem_map: e_phys=f186d000 maddr=f73fe000 type=0 len=4096 index=4 first_map=1
pt_iomem_map: e_phys=f186e000 maddr=fbffc000 type=0 len=4096 index=0 first_map=1
pt_iomem_map: e_phys=f186f000 maddr=fbff6000 type=0 len=4096 index=0 first_map=1
pt_ioport_map: e_phys=c200 pio_base=b800 len=256 index=2 first_map=1
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is rw state.
platform_fixed_ioport: changed ro/rw state of ROM memory area. now is ro state.
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:05.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]
pt_pci_read_config: Error: Failed to read register with invalid access size alignment. [00:06.0][Offset:0eh][Length:4]

[-- Attachment #3: ~W7Test.cfg --]
[-- Type: application/octet-stream, Size: 1181 bytes --]

#kernel = "/usr/lib/xen/boot/hvmloader"
builder='hvm'
memory = 8192

vcpus = 8

# Should be at least 2KB per MB of domain memory, plus a few MB per vcpu.
shadow_memory = 32
name = "W7Test"
vif = [ 'type=ioemu, bridge=xenbr0' ]
viridian = 1
acpi = 1
apic = 1
pae = 1
hpet = 1
hap = 1
disk = [ 'phy:/dev/mapper/VMStore-W7Test,hdb,w', 'file:/mnt/cdserv/w7.iso,hda:cdrom,r' ]

#device_model = "/usr/lib64/xen/bin/qemu-dm"

#-----------------------------------------------------------------------------
# boot on floppy (a), hard disk (c) or CD-ROM (d) 
# default: hard disk, cd-rom, floppy
boot="cd"
sdl=0
vnc=1
vncconsole=1
vncpasswd=''

serial='pty'
usbdevice='tablet'

gfx_passthru = 1
#pci = [ '01:00.0', '01:00.1' ]
#pci = [ '01:00.0', '01:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]

pci = [ '0b:00.0', '0b:00.1' ]
#pci = [ '0b:00.0', '0b:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]
#pci = [ '0b:00.0', '0b:00.1', '01:00.0', '01:00.1', '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]

#pci = [ '0e:00.0', '04:00.0', '00:1a.0', '00:1b.0', '00:1d.0' ]
pci_msitranslate = 1
pci_power_mgmt = 1

[-- Attachment #4: ~xend.log --]
[-- Type: application/octet-stream, Size: 442737 bytes --]

[-- Attachment #5: ~xend-config.sxp --]
[-- Type: application/octet-stream, Size: 11360 bytes --]

# -*- sh -*-

#
# Xend configuration file.
#

# This example configuration is appropriate for an installation that 
# utilizes a bridged network configuration. Access to xend via http
# is disabled.  

# Commented out entries show the default for that entry, unless otherwise
# specified.

#(logfile /var/log/xen/xend.log)
#(loglevel DEBUG)

# Uncomment the line below.  Set the value to flask, acm, or dummy to 
# select a security module.

#(xsm_module_name dummy)

# The Xen-API server configuration.
#
# This value configures the ports, interfaces, and access controls for the
# Xen-API server.  Each entry in the list starts with either unix, a port
# number, or an address:port pair.  If this is "unix", then a UDP socket is
# opened, and this entry applies to that.  If it is a port, then Xend will
# listen on all interfaces on that TCP port, and if it is an address:port
# pair, then Xend will listen on the specified port, using the interface with
# the specified address.
#
# The subsequent string configures the user-based access control for the
# listener in question.  This can be one of "none" or "pam", indicating either
# that users should be allowed access unconditionally, or that the local
# Pluggable Authentication Modules configuration should be used.  If this
# string is missing or empty, then "pam" is used.
#
# The final string gives the host-based access control for that listener. If
# this is missing or empty, then all connections are accepted.  Otherwise,
# this should be a space-separated sequence of regular expressions; any host
# with a fully-qualified domain name or an IP address that matches one of
# these regular expressions will be accepted.
#
# Example: listen on TCP port 9363 on all interfaces, accepting connections
# only from machines in example.com or localhost, and allow access through
# the unix domain socket unconditionally:
#
#   (xen-api-server ((9363 pam '^localhost$ example\\.com$')
#                    (unix none)))
#
# Optionally, the TCP Xen-API server can use SSL by specifying the private
# key and certificate location:
#
#                    (9367 pam '' xen-api.key xen-api.crt)
#
# Default:
#   (xen-api-server ((unix)))


#(xend-http-server no)
#(xend-unix-server no)
#(xend-tcp-xmlrpc-server no)
#(xend-unix-xmlrpc-server yes)
#(xend-relocation-server no)
(xend-relocation-server yes)
#(xend-relocation-ssl-server no)
#(xend-udev-event-server no)

#(xend-unix-path /var/lib/xend/xend-socket)


# Address and port xend should use for the legacy TCP XMLRPC interface, 
# if xend-tcp-xmlrpc-server is set.
#(xend-tcp-xmlrpc-server-address 'localhost')
#(xend-tcp-xmlrpc-server-port 8006)

# SSL key and certificate to use for the legacy TCP XMLRPC interface.
# Setting these will mean that this port serves only SSL connections as
# opposed to plaintext ones.
#(xend-tcp-xmlrpc-server-ssl-key-file  xmlrpc.key)
#(xend-tcp-xmlrpc-server-ssl-cert-file xmlrpc.crt)


# Port xend should use for the HTTP interface, if xend-http-server is set.
#(xend-port            8000)

# Port xend should use for the relocation interface, if xend-relocation-server
# is set.
#(xend-relocation-port 8002)

# Port xend should use for the ssl relocation interface, if
# xend-relocation-ssl-server is set.
#(xend-relocation-ssl-port 8003)

# SSL key and certificate to use for the ssl relocation interface, if
# xend-relocation-ssl-server is set.
#(xend-relocation-server-ssl-key-file   xmlrpc.key)
#(xend-relocation-server-ssl-cert-file  xmlrpc.crt)

# Whether to use ssl as default when relocating.
#(xend-relocation-ssl no)

# Address xend should listen on for HTTP connections, if xend-http-server is
# set.
# Specifying 'localhost' prevents remote connections.
# Specifying the empty string '' (the default) allows all connections.
#(xend-address '')
#(xend-address localhost)

# Address xend should listen on for relocation-socket connections, if
# xend-relocation-server is set.
# Meaning and default as for xend-address above.
# Also, interface name is allowed (e.g. eth0) there to get the
# relocation address to be bound on.
#(xend-relocation-address '')

# The hosts allowed to talk to the relocation port.  If this is empty (the
# default), then all connections are allowed (assuming that the connection
# arrives on a port and interface on which we are listening; see
# xend-relocation-port and xend-relocation-address above).  Otherwise, this
# should be a space-separated sequence of regular expressions.  Any host with
# a fully-qualified domain name or an IP address that matches one of these
# regular expressions will be accepted.
#
# For example:
#  (xend-relocation-hosts-allow '^localhost$ ^.*\\.example\\.org$')
#
#(xend-relocation-hosts-allow '')
(xend-relocation-hosts-allow '^localhost$ ^localhost\\.localdomain$')

# The limit (in kilobytes) on the size of the console buffer
#(console-limit 1024)

##
# To bridge network traffic, like this:
#
# dom0: ----------------- bridge -> real eth0 -> the network
#                            |
# domU: fake eth0 -> vifN.0 -+
#
# use
#
# (network-script network-bridge)
#
# Your default ethernet device is used as the outgoing interface, by default. 
# To use a different one (e.g. eth1) use
#
# (network-script 'network-bridge netdev=eth1')
#
# The bridge is named eth0, by default (yes, really!)
#

# It is normally much better to create the bridge yourself in
# /etc/network/interfaces.  network-bridge start does nothing if you
# already have a bridge, and network-bridge stop does nothing if the
# default bridge name (normally eth0) is not a bridge.  See
# bridge-utils-interfaces(5) for full information on the syntax in
# /etc/network/interfaces, but you probably want something like this:
#    iface xenbr0 inet static
#        address [etc]
#        netmask [etc]
#        [etc]
#        bridge_ports eth0
#
# To have network-bridge create a differently-named bridge, use:
# (network-script 'network-bridge bridge=<name>')
#
# It is possible to use the network-bridge script in more complicated
# scenarios, such as having two outgoing interfaces, with two bridges, and
# two fake interfaces per guest domain.  To do things like this, write
# yourself a wrapper script, and call network-bridge from it, as appropriate.
#
#(network-script network-bridge)

# The script used to control virtual interfaces.  This can be overridden on a
# per-vif basis when creating a domain or a configuring a new vif.  The
# vif-bridge script is designed for use with the network-bridge script, or
# similar configurations.
#
# If you have overridden the bridge name using
# (network-script 'network-bridge bridge=<name>') then you may wish to do the
# same here.  The bridge name can also be set when creating a domain or
# configuring a new vif, but a value specified here would act as a default.
#
# If you are using only one bridge, the vif-bridge script will discover that,
# so there is no need to specify it explicitly.  The default is to use
# the bridge which is listed first in the output from brctl.
#
(vif-script vif-bridge)


## Use the following if network traffic is routed, as an alternative to the
# settings for bridged networking given above.
#(network-script network-route)
#(vif-script     vif-route)


## Use the following if network traffic is routed with NAT, as an alternative
# to the settings for bridged networking given above.
#(network-script network-nat)
#(vif-script     vif-nat)

# dom0-min-mem is the lowest permissible memory level (in MB) for dom0.
# This is a minimum both for auto-ballooning (as enabled by
# enable-dom0-ballooning below) and for xm mem-set when applied to dom0.
(dom0-min-mem 196)

# Whether to enable auto-ballooning of dom0 to allow domUs to be created.
# If enable-dom0-ballooning = no, dom0 will never balloon out.
(enable-dom0-ballooning yes)

# 32-bit paravirtual domains can only consume physical
# memory below 168GB. On systems with memory beyond that address,
# they'll be confined to memory below 128GB.
# Using total_available_memory (in GB) to specify the amount of memory reserved
# in the memory pool exclusively for 32-bit paravirtual domains.
# Additionally you should use dom0_mem = <-Value> as a parameter in 
# xen kernel to reserve the memory for 32-bit paravirtual domains, default 
# is "0" (0GB).  
(total_available_memory 0) 

# In SMP system, dom0 will use dom0-cpus # of CPUS
# If dom0-cpus = 0, dom0 will take all cpus available
(dom0-cpus 0)

# Whether to enable core-dumps when domains crash.
#(enable-dump no)

# The tool used for initiating virtual TPM migration
#(external-migration-tool '')

# The interface for VNC servers to listen on. Defaults
# to 127.0.0.1  To restore old 'listen everywhere' behaviour
# set this to 0.0.0.0
#(vnc-listen '127.0.0.1')

# The default password for VNC console on HVM domain.
# Empty string is no authentication.
(vncpasswd '')

# The VNC server can be told to negotiate a TLS session
# to encryption all traffic, and provide x509 cert to
# clients enabling them to verify server identity. The
# GTK-VNC widget, virt-viewer, virt-manager and VeNCrypt
# all support the VNC extension for TLS used in QEMU. The
# TightVNC/RealVNC/UltraVNC clients do not.
#
# To enable this create x509 certificates / keys in the
# directory ${XEN_CONFIG_DIR} + vnc
#
#  ca-cert.pem       - The CA certificate
#  server-cert.pem   - The Server certificate signed by the CA
#  server-key.pem    - The server private key
#
# and then uncomment this next line
# (vnc-tls 1)

# The certificate dir can be pointed elsewhere..
#
# (vnc-x509-cert-dir vnc)

# The server can be told to request & validate an x509
# certificate from the client. Only clients with a cert
# signed by the trusted CA will be able to connect. This
# is more secure the password auth alone. Passwd auth can
# used at the same time if desired. To enable client cert
# checking uncomment this:
#
# (vnc-x509-verify 1)

# The default keymap to use for the VM's virtual keyboard
# when not specififed in VM's configuration
#(keymap 'en-us')

# Script to run when the label of a resource has changed.
#(resource-label-change-script '')

# Rotation count of qemu-dm log file.
#(qemu-dm-logrotate-count 10)

# Path where persistent domain configuration is stored.
# Default is /var/lib/xend/domains/
#(xend-domains-path /var/lib/xend/domains)

# Number of seconds xend will wait for device creation and
# destruction
#(device-create-timeout 100)
#(device-destroy-timeout 100)

# When assigning device to HVM guest, we use the strict check for HVM guest by
# default. (For PV guest, we use loose check automatically if necessary.)
# When we assign device to HVM guest, if we meet with the co-assignment
# issues or the ACS issue, we could try changing the option to 'no' -- however,
# we have to realize this may incur security issue and we can't make sure the
# device assignment could really work properly even after we do this.
#(pci-passthrough-strict-check yes)
(pci-passthrough-strict-check no)

# If we have a very big scsi device configuration, start of xend is slow,
# because xend scans all the device paths to build its internal PSCSI device
# list.  If we need only a few devices for assigning to a guest, we can reduce
# the scan to this device. Set list list of device paths in same syntax like in
# command lsscsi, e.g. ('16:0:0:0' '15:0') 
# (pscsi-device-mask ('*'))


[-- Attachment #6: ~xend-debug.log --]
[-- Type: application/octet-stream, Size: 157998 bytes --]

Xend started at Sun May  1 15:11:32 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 15:54:38 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 16:16:42 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 16:30:15 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 16:44:48 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 17:00:37 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 17:05:29 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Sun May  1 17:09:44 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 01:12:00 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 02:51:00 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target11:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target12:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 02:57:52 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target8:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 03:16:45 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 03:54:54 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Mon May  2 03:55:27 2011.
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target10:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target7:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory
Xend started at Tue May  3 03:07:24 2011.
cat: /sys/bus/scsi/devices/host1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host1/model: No such file or directory
cat: /sys/bus/scsi/devices/host1/type: No such file or directory
cat: /sys/bus/scsi/devices/host1/rev: No such file or directory
cat: /sys/bus/scsi/devices/host1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host2/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host2/model: No such file or directory
cat: /sys/bus/scsi/devices/host2/type: No such file or directory
cat: /sys/bus/scsi/devices/host2/rev: No such file or directory
cat: /sys/bus/scsi/devices/host2/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host3/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host3/model: No such file or directory
cat: /sys/bus/scsi/devices/host3/type: No such file or directory
cat: /sys/bus/scsi/devices/host3/rev: No such file or directory
cat: /sys/bus/scsi/devices/host3/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host4/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host4/model: No such file or directory
cat: /sys/bus/scsi/devices/host4/type: No such file or directory
cat: /sys/bus/scsi/devices/host4/rev: No such file or directory
cat: /sys/bus/scsi/devices/host4/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host5/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host5/model: No such file or directory
cat: /sys/bus/scsi/devices/host5/type: No such file or directory
cat: /sys/bus/scsi/devices/host5/rev: No such file or directory
cat: /sys/bus/scsi/devices/host5/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host6/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host6/model: No such file or directory
cat: /sys/bus/scsi/devices/host6/type: No such file or directory
cat: /sys/bus/scsi/devices/host6/rev: No such file or directory
cat: /sys/bus/scsi/devices/host6/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host7/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host7/model: No such file or directory
cat: /sys/bus/scsi/devices/host7/type: No such file or directory
cat: /sys/bus/scsi/devices/host7/rev: No such file or directory
cat: /sys/bus/scsi/devices/host7/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host8/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host8/model: No such file or directory
cat: /sys/bus/scsi/devices/host8/type: No such file or directory
cat: /sys/bus/scsi/devices/host8/rev: No such file or directory
cat: /sys/bus/scsi/devices/host8/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host9/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host9/model: No such file or directory
cat: /sys/bus/scsi/devices/host9/type: No such file or directory
cat: /sys/bus/scsi/devices/host9/rev: No such file or directory
cat: /sys/bus/scsi/devices/host9/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host10/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host10/model: No such file or directory
cat: /sys/bus/scsi/devices/host10/type: No such file or directory
cat: /sys/bus/scsi/devices/host10/rev: No such file or directory
cat: /sys/bus/scsi/devices/host10/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host11/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host11/model: No such file or directory
cat: /sys/bus/scsi/devices/host11/type: No such file or directory
cat: /sys/bus/scsi/devices/host11/rev: No such file or directory
cat: /sys/bus/scsi/devices/host11/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host12/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host12/model: No such file or directory
cat: /sys/bus/scsi/devices/host12/type: No such file or directory
cat: /sys/bus/scsi/devices/host12/rev: No such file or directory
cat: /sys/bus/scsi/devices/host12/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target1:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target2:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target3:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host0/model: No such file or directory
cat: /sys/bus/scsi/devices/host0/type: No such file or directory
cat: /sys/bus/scsi/devices/host0/rev: No such file or directory
cat: /sys/bus/scsi/devices/host0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target0:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target4:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target5:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host13/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host13/model: No such file or directory
cat: /sys/bus/scsi/devices/host13/type: No such file or directory
cat: /sys/bus/scsi/devices/host13/rev: No such file or directory
cat: /sys/bus/scsi/devices/host13/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target13:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target6:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target9:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host14/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host14/model: No such file or directory
cat: /sys/bus/scsi/devices/host14/type: No such file or directory
cat: /sys/bus/scsi/devices/host14/rev: No such file or directory
cat: /sys/bus/scsi/devices/host14/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:0/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/model: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/type: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/rev: No such file or directory
cat: /sys/bus/scsi/devices/target14:0:1/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/host15/vendor: No such file or directory
cat: /sys/bus/scsi/devices/host15/model: No such file or directory
cat: /sys/bus/scsi/devices/host15/type: No such file or directory
cat: /sys/bus/scsi/devices/host15/rev: No such file or directory
cat: /sys/bus/scsi/devices/host15/scsi_level: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/vendor: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/model: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/type: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/rev: No such file or directory
cat: /sys/bus/scsi/devices/target15:0:0/scsi_level: No such file or directory

[-- Attachment #7: ~xl-W7Test.log --]
[-- Type: application/octet-stream, Size: 115 bytes --]

Waiting for domain W7Test (domid 10) to die [pid 5263]
Domain 10 is dead
Unable to get domain death info, quitting

[-- Attachment #8: Type: text/plain, Size: 138 bytes --]

_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xensource.com
http://lists.xensource.com/xen-devel

^ permalink raw reply	[flat|nested] 21+ messages in thread

end of thread, other threads:[~2011-05-31 14:59 UTC | newest]

Thread overview: 21+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2011-05-17 23:14 VGA passthrough on unstable Liwei
  -- strict thread matches above, loose matches on Subject: below --
2011-05-31 14:59 Liwei
2011-05-24 15:35 Liwei
2011-05-24 15:44 ` Liwei
2011-05-03  6:29 Liwei
2011-05-03 15:20 ` Liwei
2011-05-05 11:33 ` Liwei
2011-05-05 15:20   ` Pasi Kärkkäinen
2011-05-05 16:56     ` Liwei
2011-05-05 17:06       ` Pasi Kärkkäinen
2011-05-05 17:59         ` Liwei
2011-05-05 18:12           ` Pasi Kärkkäinen
2011-05-05 18:28             ` Liwei
2011-05-05 18:33               ` Pasi Kärkkäinen
2011-05-05 18:42                 ` Liwei
2011-05-05 18:49                   ` Pasi Kärkkäinen
2011-05-09  0:26                     ` Liwei
2011-05-09 17:14     ` Javier
2011-05-10 13:12       ` JavMV
2011-05-10 13:12       ` JavMV
2011-05-10 13:12       ` JavMV