* [PATCH net 0/2] Fixes for clcsock shutdown behaviors
@ 2021-11-25  6:19 Tony Lu
  2021-11-25  6:19 ` [PATCH net 1/2] net/smc: Keep smc_close_final rc during active close Tony Lu
  2021-11-25  6:19 ` [PATCH net 2/2] net/smc: Don't call clcsock shutdown twice when smc shutdown Tony Lu
  0 siblings, 2 replies; 6+ messages in thread
From: Tony Lu @ 2021-11-25  6:19 UTC (permalink / raw)
  To: kgraul; +Cc: kuba, davem, netdev, linux-s390, linux-rdma

These patches fix issues when calling kernel_sock_shutdown(). To make
the solution clear, I split it into two patches.

Patch 1 keeps the return code of smc_close_final() in
smc_close_active(), which is more important than kernel_sock_shutdown().

Patch 2 doesn't call clcsock shutdown twice when applications call
smc_shutdown(). It should be okay to call kernel_sock_shutdown() twice,
I decide to avoid it for slightly speed up releasing socket.

Tony Lu (2):
  net/smc: Keep smc_close_final rc during active close
  net/smc: Don't call clcsock shutdown twice when smc shutdown

 net/smc/af_smc.c    | 8 ++++++++
 net/smc/smc_close.c | 8 ++++++--
 2 files changed, 14 insertions(+), 2 deletions(-)

-- 
2.32.0.3.g01195cf9f


^ permalink raw reply	[flat|nested] 6+ messages in thread

* [PATCH net 1/2] net/smc: Keep smc_close_final rc during active close
  2021-11-25  6:19 [PATCH net 0/2] Fixes for clcsock shutdown behaviors Tony Lu
@ 2021-11-25  6:19 ` Tony Lu
  2021-11-25 10:51   ` Karsten Graul
  2021-11-25  6:19 ` [PATCH net 2/2] net/smc: Don't call clcsock shutdown twice when smc shutdown Tony Lu
  1 sibling, 1 reply; 6+ messages in thread
From: Tony Lu @ 2021-11-25  6:19 UTC (permalink / raw)
  To: kgraul; +Cc: kuba, davem, netdev, linux-s390, linux-rdma

When smc_close_final() returns error, the return code overwrites by
kernel_sock_shutdown() in smc_close_active(). The return code of
smc_close_final() is more important than kernel_sock_shutdown(), and it
will pass to userspace directly.

Fix it by keeping both return codes, if smc_close_final() raises an
error, return it or kernel_sock_shutdown()'s.

Link: https://lore.kernel.org/linux-s390/1f67548e-cbf6-0dce-82b5-10288a4583bd@linux.ibm.com/
Fixes: 606a63c9783a ("net/smc: Ensure the active closing peer first closes clcsock")
Suggested-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Tony Lu <tonylu@linux.alibaba.com>
Reviewed-by: Wen Gu <guwen@linux.alibaba.com>
---
 net/smc/smc_close.c | 8 ++++++--
 1 file changed, 6 insertions(+), 2 deletions(-)

diff --git a/net/smc/smc_close.c b/net/smc/smc_close.c
index 3715d2f5ad55..292e4d904ab6 100644
--- a/net/smc/smc_close.c
+++ b/net/smc/smc_close.c
@@ -195,6 +195,7 @@ int smc_close_active(struct smc_sock *smc)
 	int old_state;
 	long timeout;
 	int rc = 0;
+	int rc1 = 0;
 
 	timeout = current->flags & PF_EXITING ?
 		  0 : sock_flag(sk, SOCK_LINGER) ?
@@ -232,8 +233,11 @@ int smc_close_active(struct smc_sock *smc)
 			/* actively shutdown clcsock before peer close it,
 			 * prevent peer from entering TIME_WAIT state.
 			 */
-			if (smc->clcsock && smc->clcsock->sk)
-				rc = kernel_sock_shutdown(smc->clcsock, SHUT_RDWR);
+			if (smc->clcsock && smc->clcsock->sk) {
+				rc1 = kernel_sock_shutdown(smc->clcsock,
+							   SHUT_RDWR);
+				rc = rc ? rc : rc1;
+			}
 		} else {
 			/* peer event has changed the state */
 			goto again;
-- 
2.32.0.3.g01195cf9f


^ permalink raw reply related	[flat|nested] 6+ messages in thread

* [PATCH net 2/2] net/smc: Don't call clcsock shutdown twice when smc shutdown
  2021-11-25  6:19 [PATCH net 0/2] Fixes for clcsock shutdown behaviors Tony Lu
  2021-11-25  6:19 ` [PATCH net 1/2] net/smc: Keep smc_close_final rc during active close Tony Lu
@ 2021-11-25  6:19 ` Tony Lu
  2021-11-25 11:02   ` Karsten Graul
  1 sibling, 1 reply; 6+ messages in thread
From: Tony Lu @ 2021-11-25  6:19 UTC (permalink / raw)
  To: kgraul; +Cc: kuba, davem, netdev, linux-s390, linux-rdma

When applications call shutdown() with SHUT_RDWR in userspace,
smc_close_active() calls kernel_sock_shutdown(), and it is called
twice in smc_shutdown().

This fixes this by checking sk_state before do clcsock shutdown, and
avoids missing the application's call of smc_shutdown().

Link: https://lore.kernel.org/linux-s390/1f67548e-cbf6-0dce-82b5-10288a4583bd@linux.ibm.com/
Fixes: 606a63c9783a ("net/smc: Ensure the active closing peer first closes clcsock")
Signed-off-by: Tony Lu <tonylu@linux.alibaba.com>
Reviewed-by: Wen Gu <guwen@linux.alibaba.com>
---
 net/smc/af_smc.c | 8 ++++++++
 1 file changed, 8 insertions(+)

diff --git a/net/smc/af_smc.c b/net/smc/af_smc.c
index 4b62c925a13e..7b04cb4d15f4 100644
--- a/net/smc/af_smc.c
+++ b/net/smc/af_smc.c
@@ -2373,6 +2373,7 @@ static int smc_shutdown(struct socket *sock, int how)
 	struct smc_sock *smc;
 	int rc = -EINVAL;
 	int rc1 = 0;
+	int old_state;
 
 	smc = smc_sk(sk);
 
@@ -2398,7 +2399,12 @@ static int smc_shutdown(struct socket *sock, int how)
 	}
 	switch (how) {
 	case SHUT_RDWR:		/* shutdown in both directions */
+		old_state = sk->sk_state;
 		rc = smc_close_active(smc);
+		if (old_state == SMC_ACTIVE &&
+		    sk->sk_state == SMC_PEERCLOSEWAIT1)
+			goto out_no_shutdown;
+
 		break;
 	case SHUT_WR:
 		rc = smc_close_shutdown_write(smc);
@@ -2410,6 +2416,8 @@ static int smc_shutdown(struct socket *sock, int how)
 	}
 	if (smc->clcsock)
 		rc1 = kernel_sock_shutdown(smc->clcsock, how);
+
+out_no_shutdown:
 	/* map sock_shutdown_cmd constants to sk_shutdown value range */
 	sk->sk_shutdown |= how + 1;
 
-- 
2.32.0.3.g01195cf9f


^ permalink raw reply related	[flat|nested] 6+ messages in thread

* Re: [PATCH net 1/2] net/smc: Keep smc_close_final rc during active close
  2021-11-25  6:19 ` [PATCH net 1/2] net/smc: Keep smc_close_final rc during active close Tony Lu
@ 2021-11-25 10:51   ` Karsten Graul
  0 siblings, 0 replies; 6+ messages in thread
From: Karsten Graul @ 2021-11-25 10:51 UTC (permalink / raw)
  To: netdev; +Cc: kuba, davem, linux-s390, linux-rdma, Tony Lu

On 25/11/2021 07:19, Tony Lu wrote:
> When smc_close_final() returns error, the return code overwrites by
> kernel_sock_shutdown() in smc_close_active(). The return code of
> smc_close_final() is more important than kernel_sock_shutdown(), and it
> will pass to userspace directly.
> 
> Fix it by keeping both return codes, if smc_close_final() raises an
> error, return it or kernel_sock_shutdown()'s.
> 
> Link: https://lore.kernel.org/linux-s390/1f67548e-cbf6-0dce-82b5-10288a4583bd@linux.ibm.com/
> Fixes: 606a63c9783a ("net/smc: Ensure the active closing peer first closes clcsock")
> Suggested-by: Karsten Graul <kgraul@linux.ibm.com>
> Signed-off-by: Tony Lu <tonylu@linux.alibaba.com>
> Reviewed-by: Wen Gu <guwen@linux.alibaba.com>
> ---

Acked-by: Karsten Graul <kgraul@linux.ibm.com>

^ permalink raw reply	[flat|nested] 6+ messages in thread

* Re: [PATCH net 2/2] net/smc: Don't call clcsock shutdown twice when smc shutdown
  2021-11-25  6:19 ` [PATCH net 2/2] net/smc: Don't call clcsock shutdown twice when smc shutdown Tony Lu
@ 2021-11-25 11:02   ` Karsten Graul
  2021-11-25 12:41     ` Tony Lu
  0 siblings, 1 reply; 6+ messages in thread
From: Karsten Graul @ 2021-11-25 11:02 UTC (permalink / raw)
  To: Tony Lu; +Cc: kuba, davem, netdev, linux-s390, linux-rdma

On 25/11/2021 07:19, Tony Lu wrote:
> diff --git a/net/smc/af_smc.c b/net/smc/af_smc.c
> index 4b62c925a13e..7b04cb4d15f4 100644
> --- a/net/smc/af_smc.c
> +++ b/net/smc/af_smc.c
> @@ -2373,6 +2373,7 @@ static int smc_shutdown(struct socket *sock, int how)
>  	struct smc_sock *smc;
>  	int rc = -EINVAL;
>  	int rc1 = 0;
> +	int old_state;

Reverse Christmas tree formatting, please.

>  
>  	smc = smc_sk(sk);
>  
> @@ -2398,7 +2399,12 @@ static int smc_shutdown(struct socket *sock, int how)
>  	}
>  	switch (how) {
>  	case SHUT_RDWR:		/* shutdown in both directions */
> +		old_state = sk->sk_state;
>  		rc = smc_close_active(smc);
> +		if (old_state == SMC_ACTIVE &&
> +		    sk->sk_state == SMC_PEERCLOSEWAIT1)
> +			goto out_no_shutdown;
> +

I would prefer a new "bool do_shutdown" instead of a goto for this skip
of the shutdown. What do you think?

>  		break;
>  	case SHUT_WR:
>  		rc = smc_close_shutdown_write(smc);
> @@ -2410,6 +2416,8 @@ static int smc_shutdown(struct socket *sock, int how)
>  	}
>  	if (smc->clcsock)
>  		rc1 = kernel_sock_shutdown(smc->clcsock, how);
> +
> +out_no_shutdown:
>  	/* map sock_shutdown_cmd constants to sk_shutdown value range */
>  	sk->sk_shutdown |= how + 1;
>  
> 

-- 
Karsten

^ permalink raw reply	[flat|nested] 6+ messages in thread

* Re: [PATCH net 2/2] net/smc: Don't call clcsock shutdown twice when smc shutdown
  2021-11-25 11:02   ` Karsten Graul
@ 2021-11-25 12:41     ` Tony Lu
  0 siblings, 0 replies; 6+ messages in thread
From: Tony Lu @ 2021-11-25 12:41 UTC (permalink / raw)
  To: Karsten Graul; +Cc: kuba, davem, netdev, linux-s390, linux-rdma

On Thu, Nov 25, 2021 at 12:02:06PM +0100, Karsten Graul wrote:
> On 25/11/2021 07:19, Tony Lu wrote:
> > diff --git a/net/smc/af_smc.c b/net/smc/af_smc.c
> > index 4b62c925a13e..7b04cb4d15f4 100644
> > --- a/net/smc/af_smc.c
> > +++ b/net/smc/af_smc.c
> > @@ -2373,6 +2373,7 @@ static int smc_shutdown(struct socket *sock, int how)
> >  	struct smc_sock *smc;
> >  	int rc = -EINVAL;
> >  	int rc1 = 0;
> > +	int old_state;
> 
> Reverse Christmas tree formatting, please.

Sorry for that, I will fix it in the next patch.

> 
> >  
> >  	smc = smc_sk(sk);
> >  
> > @@ -2398,7 +2399,12 @@ static int smc_shutdown(struct socket *sock, int how)
> >  	}
> >  	switch (how) {
> >  	case SHUT_RDWR:		/* shutdown in both directions */
> > +		old_state = sk->sk_state;
> >  		rc = smc_close_active(smc);
> > +		if (old_state == SMC_ACTIVE &&
> > +		    sk->sk_state == SMC_PEERCLOSEWAIT1)
> > +			goto out_no_shutdown;
> > +
> 
> I would prefer a new "bool do_shutdown" instead of a goto for this skip
> of the shutdown. What do you think?

I agree with you, I'd like bool condition rather than goto, which will
disturb the continuity of reading code.

I will fix it soon. Thank you.

Tony Lu

> 
> >  		break;
> >  	case SHUT_WR:
> >  		rc = smc_close_shutdown_write(smc);
> > @@ -2410,6 +2416,8 @@ static int smc_shutdown(struct socket *sock, int how)
> >  	}
> >  	if (smc->clcsock)
> >  		rc1 = kernel_sock_shutdown(smc->clcsock, how);
> > +
> > +out_no_shutdown:
> >  	/* map sock_shutdown_cmd constants to sk_shutdown value range */
> >  	sk->sk_shutdown |= how + 1;
> >  
> > 
> 
> -- 
> Karsten

^ permalink raw reply	[flat|nested] 6+ messages in thread

end of thread, other threads:[~2021-11-25 12:43 UTC | newest]

Thread overview: 6+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2021-11-25  6:19 [PATCH net 0/2] Fixes for clcsock shutdown behaviors Tony Lu
2021-11-25  6:19 ` [PATCH net 1/2] net/smc: Keep smc_close_final rc during active close Tony Lu
2021-11-25 10:51   ` Karsten Graul
2021-11-25  6:19 ` [PATCH net 2/2] net/smc: Don't call clcsock shutdown twice when smc shutdown Tony Lu
2021-11-25 11:02   ` Karsten Graul
2021-11-25 12:41     ` Tony Lu