https://bugzilla.kernel.org/show_bug.cgi?id=205461

            Bug ID: 205461
           Summary: Power-On-Reset Prevents Successful Receive Diagnostics
                    Command in SES Module.
           Product: SCSI Drivers
           Version: 2.5
    Kernel Version: 5.4-rc6
          Hardware: All
                OS: Linux
              Tree: Mainline
            Status: NEW
          Severity: normal
          Priority: P1
         Component: Other
          Assignee: scsi_drivers-other@kernel-bugs.osdl.org
          Reporter: ssiwinski@attotech.com
        Regression: No

Created attachment 285817
  --> https://bugzilla.kernel.org/attachment.cgi?id=285817&action=edit
Power-On-Reset Prevents Successful Receive Diagnostics Command

Overview:

When booting an SES device connected to an ATTO SAS HBA, the SES module issues
a 'Receive Diagnostics' command that fails with check condition power-on-reset
and is not retried by the SES module.

Interestingly, when booting an SES device connected to an LSI SAS HBA, the
Receive Diagnostics succeeds due to LSI issuing a 'Mode Sense' command prior to
the SES module sending the 'Receive Diagnostics' that clears the check
condition power-on-reset.

Us (ATTO) does not want to have to issue a command to clear the check condition
power-on-reset unless we must. There is no spec that states this is what must
happen and seems to be a case that the SES module should handle.


Steps to Reproduce:

With an ATTO SAS HBA:
Connect an SES device to an ATTO SAS HBA, then power on the SES device. 

With an LSI SAS HBA:
I was able to reproduce this issue with an LSI SAS HBA and other SAS HBAs by
unloading the SES module, issuing a target reset to the SES device, then
re-loading the SES module.


Actual Results:

In the system log you will see

[  953.809858] scsi 7:0:0:0: Power-on or device reset occurred
[  953.809891] scsi 7:0:0:0: Failed to get diagnostic page 0x1
[  953.809931] scsi 7:0:0:0: Failed to bind enclosure -19

This can also be observed in the "sas_poweron_atto.scs" SAS trace.


Expected Results:

The Receive Diagnostics command to succeed and no error logged to the system
log.

This can also be observed in a SAS trace of an SES device connected to an LSI
HBA, where the 'Receive Diagnostics' command succeeds due to the check
condition power-on-reset being cleared by the 'Mode Sense' command issued prior
to the 'Receive Diagnostics'. (Trace can be provided upon request).


Additional Information:

It appears that I cannot attach SAS traces from both ATTO and LSI devices, so I
have attached the trace while connected to an ATTO SAS HBA that clearly
exhibits the error. If both traces are needed, I can provide them by a
different means.

-- 
You are receiving this mail because:
You are watching the assignee of the bug.

^ permalink raw reply	[flat|nested] 2+ messages in thread

* [Bug 205461] Power-On-Reset Prevents Successful Receive Diagnostics Command in SES Module.
  2019-11-07 15:58 [Bug 205461] New: Power-On-Reset Prevents Successful Receive Diagnostics Command in SES Module bugzilla-daemon
@ 2019-11-07 16:00 ` bugzilla-daemon
  0 siblings, 0 replies; 2+ messages in thread
From: bugzilla-daemon @ 2019-11-07 16:00 UTC (permalink / raw)
  To: linux-scsi

https://bugzilla.kernel.org/show_bug.cgi?id=205461

Steven Siwinski (ssiwinski@attotech.com) changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
                 CC|                            |ssiwinski@attotech.com

--- Comment #1 from Steven Siwinski (ssiwinski@attotech.com) ---
Created attachment 285819
  --> https://bugzilla.kernel.org/attachment.cgi?id=285819&action=edit
SAS trace of AVAGO HBA that issues 'mode sense' prior to SES sending 'Receive
Diagnostics'

-- 
You are receiving this mail because:
You are watching the assignee of the bug.

^ permalink raw reply	[flat|nested] 2+ messages in thread

end of thread, other threads:[~2019-11-07 16:00 UTC | newest]

Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2019-11-07 15:58 [Bug 205461] New: Power-On-Reset Prevents Successful Receive Diagnostics Command in SES Module bugzilla-daemon
2019-11-07 16:00 ` [Bug 205461] " bugzilla-daemon

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).