linux-kernel.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
* [PATCH] s3c_adc_battery: average over more than one adc sample
@ 2011-12-29 11:52 Heiko Stübner
  2012-01-06  2:17 ` Anton Vorontsov
  0 siblings, 1 reply; 2+ messages in thread
From: Heiko Stübner @ 2011-12-29 11:52 UTC (permalink / raw)
  To: Anton Vorontsov, David Woodhouse
  Cc: Vasily Khoruzhick, linux-kernel, Linux PM mailing list,
	Heiko Stübner

Some sources for adc battery information provide only inaccurate results
where the read value differs from the real value with positive and negative
offsets. For such sources it can be more accurate to collect two or more
value sample and use the average of all collected values.

This patch adds pdata options volt_samples, current_samples and
backup_volt_samples to specifiy the number of samples to collect,
reads the specified number of samples and calculates the average of those.
For unset sample-number-values a default of 1 is assumed.

Signed-off-by: Heiko Stuebner <heiko@sntech.de>
---
 drivers/power/s3c_adc_battery.c |   25 ++++++++++++++++++++++---
 include/linux/s3c_adc_battery.h |    4 ++++
 2 files changed, 26 insertions(+), 3 deletions(-)

diff --git a/drivers/power/s3c_adc_battery.c b/drivers/power/s3c_adc_battery.c
index d32d0d7..98520a8 100644
--- a/drivers/power/s3c_adc_battery.c
+++ b/drivers/power/s3c_adc_battery.c
@@ -47,6 +47,22 @@ static void s3c_adc_bat_ext_power_changed(struct power_supply *psy)
 		msecs_to_jiffies(JITTER_DELAY));
 }
 
+static int gather_samples(struct s3c_adc_client *client, int num, int channel)
+{
+	int value, i;
+
+	/* default to 1 if nothing is set */
+	if (num < 1)
+		num = 1;
+
+	value = 0;
+	for (i = 0; i < num; i++)
+		value += s3c_adc_read(client, channel);
+	value /= num;
+
+	return value;
+}
+
 static enum power_supply_property s3c_adc_backup_bat_props[] = {
 	POWER_SUPPLY_PROP_VOLTAGE_NOW,
 	POWER_SUPPLY_PROP_VOLTAGE_MIN,
@@ -67,7 +83,8 @@ static int s3c_adc_backup_bat_get_property(struct power_supply *psy,
 	if (bat->volt_value < 0 ||
 		jiffies_to_msecs(jiffies - bat->timestamp) >
 			BAT_POLL_INTERVAL) {
-		bat->volt_value = s3c_adc_read(bat->client,
+		bat->volt_value = gather_samples(bat->client,
+			bat->pdata->backup_volt_samples,
 			bat->pdata->backup_volt_channel);
 		bat->volt_value *= bat->pdata->backup_volt_mult;
 		bat->timestamp = jiffies;
@@ -139,9 +156,11 @@ static int s3c_adc_bat_get_property(struct power_supply *psy,
 	if (bat->volt_value < 0 || bat->cur_value < 0 ||
 		jiffies_to_msecs(jiffies - bat->timestamp) >
 			BAT_POLL_INTERVAL) {
-		bat->volt_value = s3c_adc_read(bat->client,
+		bat->volt_value = gather_samples(bat->client,
+			bat->pdata->volt_samples,
 			bat->pdata->volt_channel) * bat->pdata->volt_mult;
-		bat->cur_value = s3c_adc_read(bat->client,
+		bat->cur_value = gather_samples(bat->client,
+			bat->pdata->current_samples,
 			bat->pdata->current_channel) * bat->pdata->current_mult;
 		bat->timestamp = jiffies;
 	}
diff --git a/include/linux/s3c_adc_battery.h b/include/linux/s3c_adc_battery.h
index fbe58b7..99dadbf 100644
--- a/include/linux/s3c_adc_battery.h
+++ b/include/linux/s3c_adc_battery.h
@@ -25,6 +25,10 @@ struct s3c_adc_bat_pdata {
 	const unsigned int current_channel;
 	const unsigned int backup_volt_channel;
 
+	const unsigned int volt_samples;
+	const unsigned int current_samples;
+	const unsigned int backup_volt_samples;
+
 	const unsigned int volt_mult;
 	const unsigned int current_mult;
 	const unsigned int backup_volt_mult;
-- 
1.7.2.3


^ permalink raw reply related	[flat|nested] 2+ messages in thread

* Re: [PATCH] s3c_adc_battery: average over more than one adc sample
  2011-12-29 11:52 [PATCH] s3c_adc_battery: average over more than one adc sample Heiko Stübner
@ 2012-01-06  2:17 ` Anton Vorontsov
  0 siblings, 0 replies; 2+ messages in thread
From: Anton Vorontsov @ 2012-01-06  2:17 UTC (permalink / raw)
  To: Heiko Stübner
  Cc: David Woodhouse, Vasily Khoruzhick, linux-kernel, Linux PM mailing list

On Thu, Dec 29, 2011 at 12:52:07PM +0100, Heiko Stübner wrote:
> Some sources for adc battery information provide only inaccurate results
> where the read value differs from the real value with positive and negative
> offsets. For such sources it can be more accurate to collect two or more
> value sample and use the average of all collected values.
> 
> This patch adds pdata options volt_samples, current_samples and
> backup_volt_samples to specifiy the number of samples to collect,
> reads the specified number of samples and calculates the average of those.
> For unset sample-number-values a default of 1 is assumed.
> 
> Signed-off-by: Heiko Stuebner <heiko@sntech.de>
> ---

Applied, thanks!

-- 
Anton Vorontsov
Email: cbouatmailru@gmail.com

^ permalink raw reply	[flat|nested] 2+ messages in thread

end of thread, other threads:[~2012-01-06  2:17 UTC | newest]

Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2011-12-29 11:52 [PATCH] s3c_adc_battery: average over more than one adc sample Heiko Stübner
2012-01-06  2:17 ` Anton Vorontsov

This is a public inbox, see mirroring instructions