* [RFC PATCH 0/8] coresight: Update device tree bindings
@ 2018-06-01 13:15 ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:15 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose

Coresight uses DT graph bindings to describe the connections of the
components. However we have some undocumented usage of the bindings
to describe some of the properties of the connections.

The coresight driver needs to know the hardware ports invovled
in the connection and the direction of data flow to effectively
manage the trace sessions. So far we have relied on the "port"
address (as described by the generic graph bindings) to represent
the hardware port of the component for a connection.

The hardware uses separate numbering scheme for input and output
ports, which implies, we could have two different (input and output)
ports with the same port number. This could create problems in the
graph bindings where the label of the port wouldn't match the address.

e.g, with the existing bindings we get :

	port@0{				// Output port 0
		reg = <0>;
		...
	};

	port@1{
		reg = <0>;		// Input port 0
		endpoint {
			slave-mode;
			...
		};
	};

With the new enforcement in the DT rules, mismatches in label and address
are not allowed (as see in the case for port@1). So, we need a new mechanism
to describe the hardware port number reliably.

Also, we relied on an undocumented "slave-mode" property (see the above
example) to indicate if the port is an input port. Let us formalise and
switch to a new property to describe the direction of data flow.

There were three options considered for the hardware port number scheme:

 1) Use natural ordering in the DT to infer the hardware port number.
  i.e, Mandate that the all ports are listed in the DT and in the ascending
  order for each class (input and output respectively).
   Pros :
      - We don't need new properties and if the existing DTS list them in
        order (which most of them do), they work out of the box.
   Cons :
      - We must list all the ports even if the system cannot/shouldn't use
        it.
      - It is prone to human errors (if the order is not kept).

 2) Use an explicit property to list both the direction and the hw port
    number and direction. Define "coresight,hwid" as 2 member array of u32,
    where the members are port number and the direction respectively.
	e.g

	port@0{
		reg = <0>;
		endpoint {
			coresight,hwid = <0 1>;	// Port # 0, Output
		}
	};

	port@1{
		reg = <1>;
		endpoint {
			coresight,hwid = <0 0>;	// Port # 0, Input
		};
	};

	Pros:
	  - The bindings are formal but not so reader friendly and could potentially
	    lead to human errors.
	Cons:
	  - Backward compatiblity is lost.
 3) Use explicit properties (implemented in the series) for the hardware
    port id and direction. We define a new property "coresight,hwid" for
    each endpoint in coresight devices to specify the hardware port number
    explicitly. Also use a separate property "direction" to specify the
    direction of the data flow.

	e.g,

	port@0{
		reg = <0>;
		endpoint {
			direction = <1>;	// Output
			coresight,hwid = <0>;	// Port # 0
		}
	};

	port@1{
		reg = <1>;
		endpoint {
			direction = <0>;	// Input
			coresight,hwid = <0>;	// Port # 0
		};
	};

    Pros:
       - The bindings are formal and reader friendly, and less prone to errors.
    Cons:
       - Backward compatibility is lost.


This series achieves implements Option (3) listed above while still retaining
the backward compatibility. The driver now issues a warning (once) when it
encounters the old bindings.
It also cleans up the platform parsing code to reduce the memory usage by
reusing the platform description. The series also includes the
changes for Juno platform as an example. If there are no objections
to the approach, I could post the series, converting all the
in-kernel DTS to the new binding.

Suzuki K Poulose (8):
  dts: binding: coresight: Document graph bindings
  coresight: Fix remote endpoint parsing
  coresight: Cleanup platform description data
  coresight: platform: Cleanup coresight connection handling
  coresight: Handle errors in finding input/output ports
  dts: coresight: Clean up the device tree graph bindings
  dts: coresight: Define new bindings for direction of data flow
  dts: juno: Update coresight bindings for hw port

 .../devicetree/bindings/arm/coresight.txt          |  52 ++++++++--
 arch/arm64/boot/dts/arm/juno-base.dtsi             |  82 +++++++++++----
 arch/arm64/boot/dts/arm/juno.dts                   |   5 +-
 drivers/hwtracing/coresight/coresight.c            |  28 ++----
 drivers/hwtracing/coresight/of_coresight.c         | 111 ++++++++++++---------
 include/linux/coresight.h                          |  11 +-
 6 files changed, 181 insertions(+), 108 deletions(-)

-- 
2.7.4

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 0/8] coresight: Update device tree bindings
@ 2018-06-01 13:15 ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:15 UTC (permalink / raw)
  To: linux-arm-kernel

Coresight uses DT graph bindings to describe the connections of the
components. However we have some undocumented usage of the bindings
to describe some of the properties of the connections.

The coresight driver needs to know the hardware ports invovled
in the connection and the direction of data flow to effectively
manage the trace sessions. So far we have relied on the "port"
address (as described by the generic graph bindings) to represent
the hardware port of the component for a connection.

The hardware uses separate numbering scheme for input and output
ports, which implies, we could have two different (input and output)
ports with the same port number. This could create problems in the
graph bindings where the label of the port wouldn't match the address.

e.g, with the existing bindings we get :

	port at 0{				// Output port 0
		reg = <0>;
		...
	};

	port at 1{
		reg = <0>;		// Input port 0
		endpoint {
			slave-mode;
			...
		};
	};

With the new enforcement in the DT rules, mismatches in label and address
are not allowed (as see in the case for port at 1). So, we need a new mechanism
to describe the hardware port number reliably.

Also, we relied on an undocumented "slave-mode" property (see the above
example) to indicate if the port is an input port. Let us formalise and
switch to a new property to describe the direction of data flow.

There were three options considered for the hardware port number scheme:

 1) Use natural ordering in the DT to infer the hardware port number.
  i.e, Mandate that the all ports are listed in the DT and in the ascending
  order for each class (input and output respectively).
   Pros :
      - We don't need new properties and if the existing DTS list them in
        order (which most of them do), they work out of the box.
   Cons :
      - We must list all the ports even if the system cannot/shouldn't use
        it.
      - It is prone to human errors (if the order is not kept).

 2) Use an explicit property to list both the direction and the hw port
    number and direction. Define "coresight,hwid" as 2 member array of u32,
    where the members are port number and the direction respectively.
	e.g

	port at 0{
		reg = <0>;
		endpoint {
			coresight,hwid = <0 1>;	// Port # 0, Output
		}
	};

	port at 1{
		reg = <1>;
		endpoint {
			coresight,hwid = <0 0>;	// Port # 0, Input
		};
	};

	Pros:
	  - The bindings are formal but not so reader friendly and could potentially
	    lead to human errors.
	Cons:
	  - Backward compatiblity is lost.
 3) Use explicit properties (implemented in the series) for the hardware
    port id and direction. We define a new property "coresight,hwid" for
    each endpoint in coresight devices to specify the hardware port number
    explicitly. Also use a separate property "direction" to specify the
    direction of the data flow.

	e.g,

	port at 0{
		reg = <0>;
		endpoint {
			direction = <1>;	// Output
			coresight,hwid = <0>;	// Port # 0
		}
	};

	port at 1{
		reg = <1>;
		endpoint {
			direction = <0>;	// Input
			coresight,hwid = <0>;	// Port # 0
		};
	};

    Pros:
       - The bindings are formal and reader friendly, and less prone to errors.
    Cons:
       - Backward compatibility is lost.


This series achieves implements Option (3) listed above while still retaining
the backward compatibility. The driver now issues a warning (once) when it
encounters the old bindings.
It also cleans up the platform parsing code to reduce the memory usage by
reusing the platform description. The series also includes the
changes for Juno platform as an example. If there are no objections
to the approach, I could post the series, converting all the
in-kernel DTS to the new binding.

Suzuki K Poulose (8):
  dts: binding: coresight: Document graph bindings
  coresight: Fix remote endpoint parsing
  coresight: Cleanup platform description data
  coresight: platform: Cleanup coresight connection handling
  coresight: Handle errors in finding input/output ports
  dts: coresight: Clean up the device tree graph bindings
  dts: coresight: Define new bindings for direction of data flow
  dts: juno: Update coresight bindings for hw port

 .../devicetree/bindings/arm/coresight.txt          |  52 ++++++++--
 arch/arm64/boot/dts/arm/juno-base.dtsi             |  82 +++++++++++----
 arch/arm64/boot/dts/arm/juno.dts                   |   5 +-
 drivers/hwtracing/coresight/coresight.c            |  28 ++----
 drivers/hwtracing/coresight/of_coresight.c         | 111 ++++++++++++---------
 include/linux/coresight.h                          |  11 +-
 6 files changed, 181 insertions(+), 108 deletions(-)

-- 
2.7.4

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 1/8] dts: binding: coresight: Document graph bindings
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 13:16   ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose

Before we updat the bindings, document the current graph bindings
and usage of additional properties.

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 .../devicetree/bindings/arm/coresight.txt          | 28 ++++++++++++++++++----
 1 file changed, 24 insertions(+), 4 deletions(-)

diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
index 15ac8e8..bd36e40 100644
--- a/Documentation/devicetree/bindings/arm/coresight.txt
+++ b/Documentation/devicetree/bindings/arm/coresight.txt
@@ -52,9 +52,7 @@ its hardware characteristcs.
 	  clocks the core of that coresight component. The latter clock
 	  is optional.
 
-	* port or ports: The representation of the component's port
-	  layout using the generic DT graph presentation found in
-	  "bindings/graph.txt".
+	* port or ports: see "Graph bindings for Coresight" below
 
 * Additional required properties for System Trace Macrocells (STM):
 	* reg: along with the physical base address and length of the register
@@ -71,7 +69,7 @@ its hardware characteristcs.
 	  AMBA markee):
 		- "arm,coresight-replicator"
 
-	* port or ports: same as above.
+	* port or ports: see "Graph bindings for Coresight" below.
 
 * Optional properties for ETM/PTMs:
 
@@ -86,6 +84,28 @@ its hardware characteristcs.
 	* arm,buffer-size: size of contiguous buffer space for TMC ETR
 	 (embedded trace router)
 
+Graph bindings for Coresight
+-------------------------------
+
+Coresight components are interconnected to create a data path for the flow of
+trace data generated from the "sources" to their collection points "sink". Each
+coresight component must describe the "input" and "output" connections.
+The connections must be described via generic DT graph bindings as described
+by the "bindings/graph.txt", where each "port" along with an "endpoint" component
+represents a hardware port and the connection.
+
+Since it is possible to have multiple connections for any coresight component with
+a specific direction of data flow, each connection must define the following
+properties to uniquely identify the connection details.
+
+ * Direction of the data flow w.r.t the component :
+   Each input port must have the following property defined at the "endpoint"
+   for the port.
+	"slave-mode"
+
+ * Hardware Port number at the component:
+     -  The hardware port number is assumed to be the address of the "port" component.
+
 
 Example:
 
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 1/8] dts: binding: coresight: Document graph bindings
@ 2018-06-01 13:16   ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel

Before we updat the bindings, document the current graph bindings
and usage of additional properties.

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 .../devicetree/bindings/arm/coresight.txt          | 28 ++++++++++++++++++----
 1 file changed, 24 insertions(+), 4 deletions(-)

diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
index 15ac8e8..bd36e40 100644
--- a/Documentation/devicetree/bindings/arm/coresight.txt
+++ b/Documentation/devicetree/bindings/arm/coresight.txt
@@ -52,9 +52,7 @@ its hardware characteristcs.
 	  clocks the core of that coresight component. The latter clock
 	  is optional.
 
-	* port or ports: The representation of the component's port
-	  layout using the generic DT graph presentation found in
-	  "bindings/graph.txt".
+	* port or ports: see "Graph bindings for Coresight" below
 
 * Additional required properties for System Trace Macrocells (STM):
 	* reg: along with the physical base address and length of the register
@@ -71,7 +69,7 @@ its hardware characteristcs.
 	  AMBA markee):
 		- "arm,coresight-replicator"
 
-	* port or ports: same as above.
+	* port or ports: see "Graph bindings for Coresight" below.
 
 * Optional properties for ETM/PTMs:
 
@@ -86,6 +84,28 @@ its hardware characteristcs.
 	* arm,buffer-size: size of contiguous buffer space for TMC ETR
 	 (embedded trace router)
 
+Graph bindings for Coresight
+-------------------------------
+
+Coresight components are interconnected to create a data path for the flow of
+trace data generated from the "sources" to their collection points "sink". Each
+coresight component must describe the "input" and "output" connections.
+The connections must be described via generic DT graph bindings as described
+by the "bindings/graph.txt", where each "port" along with an "endpoint" component
+represents a hardware port and the connection.
+
+Since it is possible to have multiple connections for any coresight component with
+a specific direction of data flow, each connection must define the following
+properties to uniquely identify the connection details.
+
+ * Direction of the data flow w.r.t the component :
+   Each input port must have the following property defined at the "endpoint"
+   for the port.
+	"slave-mode"
+
+ * Hardware Port number at the component:
+     -  The hardware port number is assumed to be the address of the "port" component.
+
 
 Example:
 
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 2/8] coresight: Fix remote endpoint parsing
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 13:16   ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose

When parsing the remote endpoint of an output port, we do :
     rport = of_graph_get_remote_port(ep);
     rparent = of_graph_get_remote_port_parent(ep);

and then parse the "remote_port" as if it was the remote endpoint,
which is wrong. The code worked fine because we used endpoint number
as the port number. Let us fix it and optimise a bit as:

     remote_ep = of_graph_get_remote_endpoint(ep);
     if (remote_ep)
        remote_parent = of_graph_get_port_parent(remote_ep);

and then, parse the remote_ep for the port/endpoint details.

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 drivers/hwtracing/coresight/of_coresight.c | 19 ++++++++++---------
 1 file changed, 10 insertions(+), 9 deletions(-)

diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
index 7c37544..e0deab0 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -128,7 +128,7 @@ of_get_coresight_platform_data(struct device *dev,
 	struct device *rdev;
 	struct device_node *ep = NULL;
 	struct device_node *rparent = NULL;
-	struct device_node *rport = NULL;
+	struct device_node *rep = NULL;
 
 	pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL);
 	if (!pdata)
@@ -169,16 +169,17 @@ of_get_coresight_platform_data(struct device *dev,
 			pdata->outports[i] = endpoint.port;
 
 			/*
-			 * Get a handle on the remote port and parent
-			 * attached to it.
+			 * Get a handle on the remote endpoint and the device
+			 * it is attached to.
 			 */
-			rparent = of_graph_get_remote_port_parent(ep);
-			rport = of_graph_get_remote_port(ep);
-
-			if (!rparent || !rport)
+			rep = of_graph_get_remote_endpoint(ep);
+			if (!rep)
+				continue;
+			rparent = of_graph_get_port_parent(rep);
+			if (!rparent)
 				continue;
 
-			if (of_graph_parse_endpoint(rport, &rendpoint))
+			if (of_graph_parse_endpoint(rep, &rendpoint))
 				continue;
 
 			rdev = of_coresight_get_endpoint_device(rparent);
@@ -186,7 +187,7 @@ of_get_coresight_platform_data(struct device *dev,
 				return ERR_PTR(-EPROBE_DEFER);
 
 			pdata->child_names[i] = dev_name(rdev);
-			pdata->child_ports[i] = rendpoint.id;
+			pdata->child_ports[i] = rendpoint.port;
 
 			i++;
 		} while (ep);
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 2/8] coresight: Fix remote endpoint parsing
@ 2018-06-01 13:16   ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel

When parsing the remote endpoint of an output port, we do :
     rport = of_graph_get_remote_port(ep);
     rparent = of_graph_get_remote_port_parent(ep);

and then parse the "remote_port" as if it was the remote endpoint,
which is wrong. The code worked fine because we used endpoint number
as the port number. Let us fix it and optimise a bit as:

     remote_ep = of_graph_get_remote_endpoint(ep);
     if (remote_ep)
        remote_parent = of_graph_get_port_parent(remote_ep);

and then, parse the remote_ep for the port/endpoint details.

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 drivers/hwtracing/coresight/of_coresight.c | 19 ++++++++++---------
 1 file changed, 10 insertions(+), 9 deletions(-)

diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
index 7c37544..e0deab0 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -128,7 +128,7 @@ of_get_coresight_platform_data(struct device *dev,
 	struct device *rdev;
 	struct device_node *ep = NULL;
 	struct device_node *rparent = NULL;
-	struct device_node *rport = NULL;
+	struct device_node *rep = NULL;
 
 	pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL);
 	if (!pdata)
@@ -169,16 +169,17 @@ of_get_coresight_platform_data(struct device *dev,
 			pdata->outports[i] = endpoint.port;
 
 			/*
-			 * Get a handle on the remote port and parent
-			 * attached to it.
+			 * Get a handle on the remote endpoint and the device
+			 * it is attached to.
 			 */
-			rparent = of_graph_get_remote_port_parent(ep);
-			rport = of_graph_get_remote_port(ep);
-
-			if (!rparent || !rport)
+			rep = of_graph_get_remote_endpoint(ep);
+			if (!rep)
+				continue;
+			rparent = of_graph_get_port_parent(rep);
+			if (!rparent)
 				continue;
 
-			if (of_graph_parse_endpoint(rport, &rendpoint))
+			if (of_graph_parse_endpoint(rep, &rendpoint))
 				continue;
 
 			rdev = of_coresight_get_endpoint_device(rparent);
@@ -186,7 +187,7 @@ of_get_coresight_platform_data(struct device *dev,
 				return ERR_PTR(-EPROBE_DEFER);
 
 			pdata->child_names[i] = dev_name(rdev);
-			pdata->child_ports[i] = rendpoint.id;
+			pdata->child_ports[i] = rendpoint.port;
 
 			i++;
 		} while (ep);
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 3/8] coresight: Cleanup platform description data
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 13:16   ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose

Nobody uses the "clk" field in struct coresight_platform_data.
Remove it.

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 include/linux/coresight.h | 2 --
 1 file changed, 2 deletions(-)

diff --git a/include/linux/coresight.h b/include/linux/coresight.h
index d950dad..32aaa1c 100644
--- a/include/linux/coresight.h
+++ b/include/linux/coresight.h
@@ -94,7 +94,6 @@ struct coresight_dev_subtype {
  * @child_ports:child component port number the current component is
 		connected  to.
  * @nr_outport:	number of output ports for this component.
- * @clk:	The clock this component is associated to.
  */
 struct coresight_platform_data {
 	int cpu;
@@ -104,7 +103,6 @@ struct coresight_platform_data {
 	const char **child_names;
 	int *child_ports;
 	int nr_outport;
-	struct clk *clk;
 };
 
 /**
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 3/8] coresight: Cleanup platform description data
@ 2018-06-01 13:16   ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel

Nobody uses the "clk" field in struct coresight_platform_data.
Remove it.

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 include/linux/coresight.h | 2 --
 1 file changed, 2 deletions(-)

diff --git a/include/linux/coresight.h b/include/linux/coresight.h
index d950dad..32aaa1c 100644
--- a/include/linux/coresight.h
+++ b/include/linux/coresight.h
@@ -94,7 +94,6 @@ struct coresight_dev_subtype {
  * @child_ports:child component port number the current component is
 		connected  to.
  * @nr_outport:	number of output ports for this component.
- * @clk:	The clock this component is associated to.
  */
 struct coresight_platform_data {
 	int cpu;
@@ -104,7 +103,6 @@ struct coresight_platform_data {
 	const char **child_names;
 	int *child_ports;
 	int nr_outport;
-	struct clk *clk;
 };
 
 /**
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 4/8] coresight: platform: Cleanup coresight connection handling
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 13:16   ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose

The platform code parses the component connections and populates
a platform-description of the output connections in arrays of fields
(which is never freed). This is later copied in the coresight_register
to a newly allocated area, represented by coresight_connection(s).

This patch cleans up the code dealing with connections by making
use of the "coresight_connection" structure right at the platform
code and lets the generic driver simply re-use information provided
by the platform.

Thus making it reader friendly as well as avoiding the wastage of
unused memory.

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 drivers/hwtracing/coresight/coresight.c    | 21 +---------------
 drivers/hwtracing/coresight/of_coresight.c | 40 +++++++++++-------------------
 include/linux/coresight.h                  |  9 ++-----
 3 files changed, 17 insertions(+), 53 deletions(-)

diff --git a/drivers/hwtracing/coresight/coresight.c b/drivers/hwtracing/coresight/coresight.c
index 389c4ba..3b3756e 100644
--- a/drivers/hwtracing/coresight/coresight.c
+++ b/drivers/hwtracing/coresight/coresight.c
@@ -961,13 +961,11 @@ postcore_initcall(coresight_init);
 
 struct coresight_device *coresight_register(struct coresight_desc *desc)
 {
-	int i;
 	int ret;
 	int link_subtype;
 	int nr_refcnts = 1;
 	atomic_t *refcnts = NULL;
 	struct coresight_device *csdev;
-	struct coresight_connection *conns = NULL;
 
 	csdev = kzalloc(sizeof(*csdev), GFP_KERNEL);
 	if (!csdev) {
@@ -996,22 +994,7 @@ struct coresight_device *coresight_register(struct coresight_desc *desc)
 	csdev->nr_inport = desc->pdata->nr_inport;
 	csdev->nr_outport = desc->pdata->nr_outport;
 
-	/* Initialise connections if there is at least one outport */
-	if (csdev->nr_outport) {
-		conns = kcalloc(csdev->nr_outport, sizeof(*conns), GFP_KERNEL);
-		if (!conns) {
-			ret = -ENOMEM;
-			goto err_kzalloc_conns;
-		}
-
-		for (i = 0; i < csdev->nr_outport; i++) {
-			conns[i].outport = desc->pdata->outports[i];
-			conns[i].child_name = desc->pdata->child_names[i];
-			conns[i].child_port = desc->pdata->child_ports[i];
-		}
-	}
-
-	csdev->conns = conns;
+	csdev->conns = desc->pdata->conns;
 
 	csdev->type = desc->type;
 	csdev->subtype = desc->subtype;
@@ -1039,8 +1022,6 @@ struct coresight_device *coresight_register(struct coresight_desc *desc)
 	return csdev;
 
 err_device_register:
-	kfree(conns);
-err_kzalloc_conns:
 	kfree(refcnts);
 err_kzalloc_refcnts:
 	kfree(csdev);
diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
index e0deab0..a3f3416 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -77,26 +77,13 @@ static void of_coresight_get_ports(const struct device_node *node,
 static int of_coresight_alloc_memory(struct device *dev,
 			struct coresight_platform_data *pdata)
 {
-	/* List of output port on this component */
-	pdata->outports = devm_kzalloc(dev, pdata->nr_outport *
-				       sizeof(*pdata->outports),
-				       GFP_KERNEL);
-	if (!pdata->outports)
-		return -ENOMEM;
-
-	/* Children connected to this component via @outports */
-	pdata->child_names = devm_kzalloc(dev, pdata->nr_outport *
-					  sizeof(*pdata->child_names),
-					  GFP_KERNEL);
-	if (!pdata->child_names)
-		return -ENOMEM;
-
-	/* Port number on the child this component is connected to */
-	pdata->child_ports = devm_kzalloc(dev, pdata->nr_outport *
-					  sizeof(*pdata->child_ports),
-					  GFP_KERNEL);
-	if (!pdata->child_ports)
-		return -ENOMEM;
+	if (pdata->nr_outport) {
+		pdata->conns = devm_kzalloc(dev, pdata->nr_outport *
+					    sizeof(*pdata->conns),
+					    GFP_KERNEL);
+		if (!pdata->conns)
+			return -ENOMEM;
+	}
 
 	return 0;
 }
@@ -122,8 +109,9 @@ struct coresight_platform_data *
 of_get_coresight_platform_data(struct device *dev,
 			       const struct device_node *node)
 {
-	int i = 0, ret = 0;
+	int ret = 0;
 	struct coresight_platform_data *pdata;
+	struct coresight_connection *conn;
 	struct of_endpoint endpoint, rendpoint;
 	struct device *rdev;
 	struct device_node *ep = NULL;
@@ -145,6 +133,7 @@ of_get_coresight_platform_data(struct device *dev,
 		if (ret)
 			return ERR_PTR(ret);
 
+		conn = pdata->conns;
 		/* Iterate through each port to discover topology */
 		do {
 			/* Get a handle on a port */
@@ -166,7 +155,7 @@ of_get_coresight_platform_data(struct device *dev,
 				continue;
 
 			/* The local out port number */
-			pdata->outports[i] = endpoint.port;
+			conn->outport = endpoint.port;
 
 			/*
 			 * Get a handle on the remote endpoint and the device
@@ -186,10 +175,9 @@ of_get_coresight_platform_data(struct device *dev,
 			if (!rdev)
 				return ERR_PTR(-EPROBE_DEFER);
 
-			pdata->child_names[i] = dev_name(rdev);
-			pdata->child_ports[i] = rendpoint.port;
-
-			i++;
+			conn->child_name = dev_name(rdev);
+			conn->child_port = rendpoint.port;
+			conn++;
 		} while (ep);
 	}
 
diff --git a/include/linux/coresight.h b/include/linux/coresight.h
index 32aaa1c..c2363bb 100644
--- a/include/linux/coresight.h
+++ b/include/linux/coresight.h
@@ -89,20 +89,15 @@ struct coresight_dev_subtype {
  * @cpu:	the CPU a source belongs to. Only applicable for ETM/PTMs.
  * @name:	name of the component as shown under sysfs.
  * @nr_inport:	number of input ports for this component.
- * @outports:	list of remote endpoint port number.
- * @child_names:name of all child components connected to this device.
- * @child_ports:child component port number the current component is
-		connected  to.
  * @nr_outport:	number of output ports for this component.
+ * @conns:	Array of nr_outport connections from this component
  */
 struct coresight_platform_data {
 	int cpu;
 	const char *name;
 	int nr_inport;
-	int *outports;
-	const char **child_names;
-	int *child_ports;
 	int nr_outport;
+	struct coresight_connection *conns;
 };
 
 /**
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 4/8] coresight: platform: Cleanup coresight connection handling
@ 2018-06-01 13:16   ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel

The platform code parses the component connections and populates
a platform-description of the output connections in arrays of fields
(which is never freed). This is later copied in the coresight_register
to a newly allocated area, represented by coresight_connection(s).

This patch cleans up the code dealing with connections by making
use of the "coresight_connection" structure right at the platform
code and lets the generic driver simply re-use information provided
by the platform.

Thus making it reader friendly as well as avoiding the wastage of
unused memory.

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 drivers/hwtracing/coresight/coresight.c    | 21 +---------------
 drivers/hwtracing/coresight/of_coresight.c | 40 +++++++++++-------------------
 include/linux/coresight.h                  |  9 ++-----
 3 files changed, 17 insertions(+), 53 deletions(-)

diff --git a/drivers/hwtracing/coresight/coresight.c b/drivers/hwtracing/coresight/coresight.c
index 389c4ba..3b3756e 100644
--- a/drivers/hwtracing/coresight/coresight.c
+++ b/drivers/hwtracing/coresight/coresight.c
@@ -961,13 +961,11 @@ postcore_initcall(coresight_init);
 
 struct coresight_device *coresight_register(struct coresight_desc *desc)
 {
-	int i;
 	int ret;
 	int link_subtype;
 	int nr_refcnts = 1;
 	atomic_t *refcnts = NULL;
 	struct coresight_device *csdev;
-	struct coresight_connection *conns = NULL;
 
 	csdev = kzalloc(sizeof(*csdev), GFP_KERNEL);
 	if (!csdev) {
@@ -996,22 +994,7 @@ struct coresight_device *coresight_register(struct coresight_desc *desc)
 	csdev->nr_inport = desc->pdata->nr_inport;
 	csdev->nr_outport = desc->pdata->nr_outport;
 
-	/* Initialise connections if there is at least one outport */
-	if (csdev->nr_outport) {
-		conns = kcalloc(csdev->nr_outport, sizeof(*conns), GFP_KERNEL);
-		if (!conns) {
-			ret = -ENOMEM;
-			goto err_kzalloc_conns;
-		}
-
-		for (i = 0; i < csdev->nr_outport; i++) {
-			conns[i].outport = desc->pdata->outports[i];
-			conns[i].child_name = desc->pdata->child_names[i];
-			conns[i].child_port = desc->pdata->child_ports[i];
-		}
-	}
-
-	csdev->conns = conns;
+	csdev->conns = desc->pdata->conns;
 
 	csdev->type = desc->type;
 	csdev->subtype = desc->subtype;
@@ -1039,8 +1022,6 @@ struct coresight_device *coresight_register(struct coresight_desc *desc)
 	return csdev;
 
 err_device_register:
-	kfree(conns);
-err_kzalloc_conns:
 	kfree(refcnts);
 err_kzalloc_refcnts:
 	kfree(csdev);
diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
index e0deab0..a3f3416 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -77,26 +77,13 @@ static void of_coresight_get_ports(const struct device_node *node,
 static int of_coresight_alloc_memory(struct device *dev,
 			struct coresight_platform_data *pdata)
 {
-	/* List of output port on this component */
-	pdata->outports = devm_kzalloc(dev, pdata->nr_outport *
-				       sizeof(*pdata->outports),
-				       GFP_KERNEL);
-	if (!pdata->outports)
-		return -ENOMEM;
-
-	/* Children connected to this component via @outports */
-	pdata->child_names = devm_kzalloc(dev, pdata->nr_outport *
-					  sizeof(*pdata->child_names),
-					  GFP_KERNEL);
-	if (!pdata->child_names)
-		return -ENOMEM;
-
-	/* Port number on the child this component is connected to */
-	pdata->child_ports = devm_kzalloc(dev, pdata->nr_outport *
-					  sizeof(*pdata->child_ports),
-					  GFP_KERNEL);
-	if (!pdata->child_ports)
-		return -ENOMEM;
+	if (pdata->nr_outport) {
+		pdata->conns = devm_kzalloc(dev, pdata->nr_outport *
+					    sizeof(*pdata->conns),
+					    GFP_KERNEL);
+		if (!pdata->conns)
+			return -ENOMEM;
+	}
 
 	return 0;
 }
@@ -122,8 +109,9 @@ struct coresight_platform_data *
 of_get_coresight_platform_data(struct device *dev,
 			       const struct device_node *node)
 {
-	int i = 0, ret = 0;
+	int ret = 0;
 	struct coresight_platform_data *pdata;
+	struct coresight_connection *conn;
 	struct of_endpoint endpoint, rendpoint;
 	struct device *rdev;
 	struct device_node *ep = NULL;
@@ -145,6 +133,7 @@ of_get_coresight_platform_data(struct device *dev,
 		if (ret)
 			return ERR_PTR(ret);
 
+		conn = pdata->conns;
 		/* Iterate through each port to discover topology */
 		do {
 			/* Get a handle on a port */
@@ -166,7 +155,7 @@ of_get_coresight_platform_data(struct device *dev,
 				continue;
 
 			/* The local out port number */
-			pdata->outports[i] = endpoint.port;
+			conn->outport = endpoint.port;
 
 			/*
 			 * Get a handle on the remote endpoint and the device
@@ -186,10 +175,9 @@ of_get_coresight_platform_data(struct device *dev,
 			if (!rdev)
 				return ERR_PTR(-EPROBE_DEFER);
 
-			pdata->child_names[i] = dev_name(rdev);
-			pdata->child_ports[i] = rendpoint.port;
-
-			i++;
+			conn->child_name = dev_name(rdev);
+			conn->child_port = rendpoint.port;
+			conn++;
 		} while (ep);
 	}
 
diff --git a/include/linux/coresight.h b/include/linux/coresight.h
index 32aaa1c..c2363bb 100644
--- a/include/linux/coresight.h
+++ b/include/linux/coresight.h
@@ -89,20 +89,15 @@ struct coresight_dev_subtype {
  * @cpu:	the CPU a source belongs to. Only applicable for ETM/PTMs.
  * @name:	name of the component as shown under sysfs.
  * @nr_inport:	number of input ports for this component.
- * @outports:	list of remote endpoint port number.
- * @child_names:name of all child components connected to this device.
- * @child_ports:child component port number the current component is
-		connected  to.
  * @nr_outport:	number of output ports for this component.
+ * @conns:	Array of nr_outport connections from this component
  */
 struct coresight_platform_data {
 	int cpu;
 	const char *name;
 	int nr_inport;
-	int *outports;
-	const char **child_names;
-	int *child_ports;
 	int nr_outport;
+	struct coresight_connection *conns;
 };
 
 /**
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 5/8] coresight: Handle errors in finding input/output ports
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 13:16   ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose

If we fail to find the input / output port for a LINK component
while enabling a path, we should fail gracefully rather than
assuming port "0".

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 drivers/hwtracing/coresight/coresight.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)

diff --git a/drivers/hwtracing/coresight/coresight.c b/drivers/hwtracing/coresight/coresight.c
index 3b3756e..4dcea6e 100644
--- a/drivers/hwtracing/coresight/coresight.c
+++ b/drivers/hwtracing/coresight/coresight.c
@@ -115,7 +115,7 @@ static int coresight_find_link_inport(struct coresight_device *csdev,
 	dev_err(&csdev->dev, "couldn't find inport, parent: %s, child: %s\n",
 		dev_name(&parent->dev), dev_name(&csdev->dev));
 
-	return 0;
+	return -ENODEV;
 }
 
 static int coresight_find_link_outport(struct coresight_device *csdev,
@@ -133,7 +133,7 @@ static int coresight_find_link_outport(struct coresight_device *csdev,
 	dev_err(&csdev->dev, "couldn't find outport, parent: %s, child: %s\n",
 		dev_name(&csdev->dev), dev_name(&child->dev));
 
-	return 0;
+	return -ENODEV;
 }
 
 static int coresight_enable_sink(struct coresight_device *csdev, u32 mode)
@@ -186,6 +186,9 @@ static int coresight_enable_link(struct coresight_device *csdev,
 	else
 		refport = 0;
 
+	if (refport < 0)
+		return refport;
+
 	if (atomic_inc_return(&csdev->refcnt[refport]) == 1) {
 		if (link_ops(csdev)->enable) {
 			ret = link_ops(csdev)->enable(csdev, inport, outport);
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 5/8] coresight: Handle errors in finding input/output ports
@ 2018-06-01 13:16   ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel

If we fail to find the input / output port for a LINK component
while enabling a path, we should fail gracefully rather than
assuming port "0".

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 drivers/hwtracing/coresight/coresight.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)

diff --git a/drivers/hwtracing/coresight/coresight.c b/drivers/hwtracing/coresight/coresight.c
index 3b3756e..4dcea6e 100644
--- a/drivers/hwtracing/coresight/coresight.c
+++ b/drivers/hwtracing/coresight/coresight.c
@@ -115,7 +115,7 @@ static int coresight_find_link_inport(struct coresight_device *csdev,
 	dev_err(&csdev->dev, "couldn't find inport, parent: %s, child: %s\n",
 		dev_name(&parent->dev), dev_name(&csdev->dev));
 
-	return 0;
+	return -ENODEV;
 }
 
 static int coresight_find_link_outport(struct coresight_device *csdev,
@@ -133,7 +133,7 @@ static int coresight_find_link_outport(struct coresight_device *csdev,
 	dev_err(&csdev->dev, "couldn't find outport, parent: %s, child: %s\n",
 		dev_name(&csdev->dev), dev_name(&child->dev));
 
-	return 0;
+	return -ENODEV;
 }
 
 static int coresight_enable_sink(struct coresight_device *csdev, u32 mode)
@@ -186,6 +186,9 @@ static int coresight_enable_link(struct coresight_device *csdev,
 	else
 		refport = 0;
 
+	if (refport < 0)
+		return refport;
+
 	if (atomic_inc_return(&csdev->refcnt[refport]) == 1) {
 		if (link_ops(csdev)->enable) {
 			ret = link_ops(csdev)->enable(csdev, inport, outport);
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 13:16   ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose

The coresight drivers relied on default bindings for graph
in DT, while reusing the "reg" field of the "ports" to indicate
the actual hardware port number for the connections. However,
with the rules getting stricter w.r.t to the address mismatch
with the label, it is no longer possible to use the port address
field for the hardware port number. Hence, we add an explicit
property to denote the hardware port number, "coresight,hwid"
which must be specified for each "endpoint".

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Cc: Sudeep Holla <sudeep.holla@arm.com>
Cc: Rob Herring <robh@kernel.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
 drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
 2 files changed, 54 insertions(+), 18 deletions(-)

diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
index bd36e40..385581a 100644
--- a/Documentation/devicetree/bindings/arm/coresight.txt
+++ b/Documentation/devicetree/bindings/arm/coresight.txt
@@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
 	"slave-mode"
 
  * Hardware Port number at the component:
-     -  The hardware port number is assumed to be the address of the "port" component.
+   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
+   - Each "endpoint" must define the hardware port of the local end of the
+     connection using the following property:
+	"coresight,hwid" - 32bit integer, hardware port number at the local end.
+
 
 
 Example:
@@ -120,6 +124,7 @@ Example:
 			etb_in_port: endpoint@0 {
 				slave-mode;
 				remote-endpoint = <&replicator_out_port0>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -134,6 +139,7 @@ Example:
 			tpiu_in_port: endpoint@0 {
 				slave-mode;
 				remote-endpoint = <&replicator_out_port1>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -154,6 +160,7 @@ Example:
 				reg = <0>;
 				replicator_out_port0: endpoint {
 					remote-endpoint = <&etb_in_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
@@ -161,15 +168,17 @@ Example:
 				reg = <1>;
 				replicator_out_port1: endpoint {
 					remote-endpoint = <&tpiu_in_port>;
+					coresight,hwid = <1>;
 				};
 			};
 
 			/* replicator input port */
 			port@2 {
-				reg = <0>;
+				reg = <1>;
 				replicator_in_port0: endpoint {
 					slave-mode;
 					remote-endpoint = <&funnel_out_port0>;
+					coresight,hwid = <0>;
 				};
 			};
 		};
@@ -191,31 +200,35 @@ Example:
 				funnel_out_port0: endpoint {
 					remote-endpoint =
 							<&replicator_in_port0>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			/* funnel input ports */
 			port@1 {
-				reg = <0>;
+				reg = <1>;
 				funnel_in_port0: endpoint {
 					slave-mode;
 					remote-endpoint = <&ptm0_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			port@2 {
-				reg = <1>;
+				reg = <2>;
 				funnel_in_port1: endpoint {
 					slave-mode;
 					remote-endpoint = <&ptm1_out_port>;
+					coresight,hwid = <1>;
 				};
 			};
 
 			port@3 {
-				reg = <2>;
+				reg = <3>;
 				funnel_in_port2: endpoint {
 					slave-mode;
 					remote-endpoint = <&etm0_out_port>;
+					coresight,hwid = <2>;
 				};
 			};
 
@@ -233,6 +246,7 @@ Example:
 		port {
 			ptm0_out_port: endpoint {
 				remote-endpoint = <&funnel_in_port0>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -247,6 +261,7 @@ Example:
 		port {
 			ptm1_out_port: endpoint {
 				remote-endpoint = <&funnel_in_port1>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -263,6 +278,7 @@ Example:
 		port {
 			stm_out_port: endpoint {
 				remote-endpoint = <&main_funnel_in_port2>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
index a3f3416..99d7a9c 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -105,14 +105,37 @@ int of_coresight_get_cpu(const struct device_node *node)
 }
 EXPORT_SYMBOL_GPL(of_coresight_get_cpu);
 
+/*
+ * of_graph_ep_coresight_get_port_id : Get the hardware port number for the
+ * given endpoint device node. Prefer the explicit "coresight,hwid" property
+ * over the endpoint register id (obsolete bindings).
+ */
+static int of_graph_ep_coresight_get_port_id(struct device *dev,
+					     struct device_node *ep_node)
+{
+	struct of_endpoint ep;
+	int rc, port_id;
+
+
+	if (!of_property_read_u32(ep_node, "coresight,hwid", &port_id))
+		return port_id;
+
+	rc = of_graph_parse_endpoint(ep_node, &ep);
+	if (rc)
+		return rc;
+	dev_warn_once(dev,
+		      "ep%d: Mandatory \"coresight,hwid\" property missing."
+		      " DT uses obsolete coresight bindings\n", ep.port);
+	return ep.port;
+}
+
 struct coresight_platform_data *
 of_get_coresight_platform_data(struct device *dev,
 			       const struct device_node *node)
 {
-	int ret = 0;
+	int ret = 0, outport, inport;
 	struct coresight_platform_data *pdata;
 	struct coresight_connection *conn;
-	struct of_endpoint endpoint, rendpoint;
 	struct device *rdev;
 	struct device_node *ep = NULL;
 	struct device_node *rparent = NULL;
@@ -148,14 +171,10 @@ of_get_coresight_platform_data(struct device *dev,
 			if (of_find_property(ep, "slave-mode", NULL))
 				continue;
 
-			/* Get a handle on the local endpoint */
-			ret = of_graph_parse_endpoint(ep, &endpoint);
-
-			if (ret)
+			outport = of_graph_ep_coresight_get_port_id(dev, ep);
+			if (outport < 0)
 				continue;
-
-			/* The local out port number */
-			conn->outport = endpoint.port;
+			conn->outport = outport;
 
 			/*
 			 * Get a handle on the remote endpoint and the device
@@ -168,15 +187,16 @@ of_get_coresight_platform_data(struct device *dev,
 			if (!rparent)
 				continue;
 
-			if (of_graph_parse_endpoint(rep, &rendpoint))
-				continue;
-
 			rdev = of_coresight_get_endpoint_device(rparent);
 			if (!rdev)
 				return ERR_PTR(-EPROBE_DEFER);
 
+			inport = of_graph_ep_coresight_get_port_id(rdev, rep);
+			if (inport < 0)
+				continue;
+
 			conn->child_name = dev_name(rdev);
-			conn->child_port = rendpoint.port;
+			conn->child_port = inport;
 			conn++;
 		} while (ep);
 	}
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-01 13:16   ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel

The coresight drivers relied on default bindings for graph
in DT, while reusing the "reg" field of the "ports" to indicate
the actual hardware port number for the connections. However,
with the rules getting stricter w.r.t to the address mismatch
with the label, it is no longer possible to use the port address
field for the hardware port number. Hence, we add an explicit
property to denote the hardware port number, "coresight,hwid"
which must be specified for each "endpoint".

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Cc: Sudeep Holla <sudeep.holla@arm.com>
Cc: Rob Herring <robh@kernel.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
 drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
 2 files changed, 54 insertions(+), 18 deletions(-)

diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
index bd36e40..385581a 100644
--- a/Documentation/devicetree/bindings/arm/coresight.txt
+++ b/Documentation/devicetree/bindings/arm/coresight.txt
@@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
 	"slave-mode"
 
  * Hardware Port number at the component:
-     -  The hardware port number is assumed to be the address of the "port" component.
+   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
+   - Each "endpoint" must define the hardware port of the local end of the
+     connection using the following property:
+	"coresight,hwid" - 32bit integer, hardware port number at the local end.
+
 
 
 Example:
@@ -120,6 +124,7 @@ Example:
 			etb_in_port: endpoint at 0 {
 				slave-mode;
 				remote-endpoint = <&replicator_out_port0>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -134,6 +139,7 @@ Example:
 			tpiu_in_port: endpoint at 0 {
 				slave-mode;
 				remote-endpoint = <&replicator_out_port1>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -154,6 +160,7 @@ Example:
 				reg = <0>;
 				replicator_out_port0: endpoint {
 					remote-endpoint = <&etb_in_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
@@ -161,15 +168,17 @@ Example:
 				reg = <1>;
 				replicator_out_port1: endpoint {
 					remote-endpoint = <&tpiu_in_port>;
+					coresight,hwid = <1>;
 				};
 			};
 
 			/* replicator input port */
 			port at 2 {
-				reg = <0>;
+				reg = <1>;
 				replicator_in_port0: endpoint {
 					slave-mode;
 					remote-endpoint = <&funnel_out_port0>;
+					coresight,hwid = <0>;
 				};
 			};
 		};
@@ -191,31 +200,35 @@ Example:
 				funnel_out_port0: endpoint {
 					remote-endpoint =
 							<&replicator_in_port0>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			/* funnel input ports */
 			port at 1 {
-				reg = <0>;
+				reg = <1>;
 				funnel_in_port0: endpoint {
 					slave-mode;
 					remote-endpoint = <&ptm0_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			port at 2 {
-				reg = <1>;
+				reg = <2>;
 				funnel_in_port1: endpoint {
 					slave-mode;
 					remote-endpoint = <&ptm1_out_port>;
+					coresight,hwid = <1>;
 				};
 			};
 
 			port at 3 {
-				reg = <2>;
+				reg = <3>;
 				funnel_in_port2: endpoint {
 					slave-mode;
 					remote-endpoint = <&etm0_out_port>;
+					coresight,hwid = <2>;
 				};
 			};
 
@@ -233,6 +246,7 @@ Example:
 		port {
 			ptm0_out_port: endpoint {
 				remote-endpoint = <&funnel_in_port0>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -247,6 +261,7 @@ Example:
 		port {
 			ptm1_out_port: endpoint {
 				remote-endpoint = <&funnel_in_port1>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -263,6 +278,7 @@ Example:
 		port {
 			stm_out_port: endpoint {
 				remote-endpoint = <&main_funnel_in_port2>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
index a3f3416..99d7a9c 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -105,14 +105,37 @@ int of_coresight_get_cpu(const struct device_node *node)
 }
 EXPORT_SYMBOL_GPL(of_coresight_get_cpu);
 
+/*
+ * of_graph_ep_coresight_get_port_id : Get the hardware port number for the
+ * given endpoint device node. Prefer the explicit "coresight,hwid" property
+ * over the endpoint register id (obsolete bindings).
+ */
+static int of_graph_ep_coresight_get_port_id(struct device *dev,
+					     struct device_node *ep_node)
+{
+	struct of_endpoint ep;
+	int rc, port_id;
+
+
+	if (!of_property_read_u32(ep_node, "coresight,hwid", &port_id))
+		return port_id;
+
+	rc = of_graph_parse_endpoint(ep_node, &ep);
+	if (rc)
+		return rc;
+	dev_warn_once(dev,
+		      "ep%d: Mandatory \"coresight,hwid\" property missing."
+		      " DT uses obsolete coresight bindings\n", ep.port);
+	return ep.port;
+}
+
 struct coresight_platform_data *
 of_get_coresight_platform_data(struct device *dev,
 			       const struct device_node *node)
 {
-	int ret = 0;
+	int ret = 0, outport, inport;
 	struct coresight_platform_data *pdata;
 	struct coresight_connection *conn;
-	struct of_endpoint endpoint, rendpoint;
 	struct device *rdev;
 	struct device_node *ep = NULL;
 	struct device_node *rparent = NULL;
@@ -148,14 +171,10 @@ of_get_coresight_platform_data(struct device *dev,
 			if (of_find_property(ep, "slave-mode", NULL))
 				continue;
 
-			/* Get a handle on the local endpoint */
-			ret = of_graph_parse_endpoint(ep, &endpoint);
-
-			if (ret)
+			outport = of_graph_ep_coresight_get_port_id(dev, ep);
+			if (outport < 0)
 				continue;
-
-			/* The local out port number */
-			conn->outport = endpoint.port;
+			conn->outport = outport;
 
 			/*
 			 * Get a handle on the remote endpoint and the device
@@ -168,15 +187,16 @@ of_get_coresight_platform_data(struct device *dev,
 			if (!rparent)
 				continue;
 
-			if (of_graph_parse_endpoint(rep, &rendpoint))
-				continue;
-
 			rdev = of_coresight_get_endpoint_device(rparent);
 			if (!rdev)
 				return ERR_PTR(-EPROBE_DEFER);
 
+			inport = of_graph_ep_coresight_get_port_id(rdev, rep);
+			if (inport < 0)
+				continue;
+
 			conn->child_name = dev_name(rdev);
-			conn->child_port = rendpoint.port;
+			conn->child_port = inport;
 			conn++;
 		} while (ep);
 	}
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 7/8] dts: coresight: Define new bindings for direction of data flow
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 13:16   ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose

So far we have relied on an undocumented property "slave-mode",
to indicate if the given port is input or not. Since we are
redefining the coresight bindings, define new property for the
"direction" of data flow for a given connection endpoint in the
device.

Each endpoint must define the following property.

 - "direction" : 0 => Port is input
		 1 => Port is output

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 drivers/hwtracing/coresight/of_coresight.c | 20 ++++++++++++++++----
 1 file changed, 16 insertions(+), 4 deletions(-)

diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
index 99d7a9c..63c1668 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -52,7 +52,19 @@ of_coresight_get_endpoint_device(struct device_node *endpoint)
 			       endpoint, of_dev_node_match);
 }
 
-static void of_coresight_get_ports(const struct device_node *node,
+static bool of_coresight_ep_is_input(struct device *dev, struct device_node *ep_node)
+{
+	u32 dir;
+
+	if (!of_property_read_u32(ep_node, "direction", &dir))
+		return dir == 0;
+
+	dev_warn_once(dev, "Missing mandatory \"direction\" property!\n");
+	return of_property_read_bool(ep_node, "slave-mode");
+}
+
+static void of_coresight_get_ports(struct device *dev,
+				   const struct device_node *node,
 				   int *nr_inport, int *nr_outport)
 {
 	struct device_node *ep = NULL;
@@ -63,7 +75,7 @@ static void of_coresight_get_ports(const struct device_node *node,
 		if (!ep)
 			break;
 
-		if (of_property_read_bool(ep, "slave-mode"))
+		if (of_coresight_ep_is_input(dev, ep))
 			in++;
 		else
 			out++;
@@ -149,7 +161,7 @@ of_get_coresight_platform_data(struct device *dev,
 	pdata->name = dev_name(dev);
 
 	/* Get the number of input and output port for this component */
-	of_coresight_get_ports(node, &pdata->nr_inport, &pdata->nr_outport);
+	of_coresight_get_ports(dev, node, &pdata->nr_inport, &pdata->nr_outport);
 
 	if (pdata->nr_outport) {
 		ret = of_coresight_alloc_memory(dev, pdata);
@@ -168,7 +180,7 @@ of_get_coresight_platform_data(struct device *dev,
 			 * No need to deal with input ports, processing for as
 			 * processing for output ports will deal with them.
 			 */
-			if (of_find_property(ep, "slave-mode", NULL))
+			if (of_coresight_ep_is_input(dev, ep))
 				continue;
 
 			outport = of_graph_ep_coresight_get_port_id(dev, ep);
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 7/8] dts: coresight: Define new bindings for direction of data flow
@ 2018-06-01 13:16   ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel

So far we have relied on an undocumented property "slave-mode",
to indicate if the given port is input or not. Since we are
redefining the coresight bindings, define new property for the
"direction" of data flow for a given connection endpoint in the
device.

Each endpoint must define the following property.

 - "direction" : 0 => Port is input
		 1 => Port is output

Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 drivers/hwtracing/coresight/of_coresight.c | 20 ++++++++++++++++----
 1 file changed, 16 insertions(+), 4 deletions(-)

diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
index 99d7a9c..63c1668 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -52,7 +52,19 @@ of_coresight_get_endpoint_device(struct device_node *endpoint)
 			       endpoint, of_dev_node_match);
 }
 
-static void of_coresight_get_ports(const struct device_node *node,
+static bool of_coresight_ep_is_input(struct device *dev, struct device_node *ep_node)
+{
+	u32 dir;
+
+	if (!of_property_read_u32(ep_node, "direction", &dir))
+		return dir == 0;
+
+	dev_warn_once(dev, "Missing mandatory \"direction\" property!\n");
+	return of_property_read_bool(ep_node, "slave-mode");
+}
+
+static void of_coresight_get_ports(struct device *dev,
+				   const struct device_node *node,
 				   int *nr_inport, int *nr_outport)
 {
 	struct device_node *ep = NULL;
@@ -63,7 +75,7 @@ static void of_coresight_get_ports(const struct device_node *node,
 		if (!ep)
 			break;
 
-		if (of_property_read_bool(ep, "slave-mode"))
+		if (of_coresight_ep_is_input(dev, ep))
 			in++;
 		else
 			out++;
@@ -149,7 +161,7 @@ of_get_coresight_platform_data(struct device *dev,
 	pdata->name = dev_name(dev);
 
 	/* Get the number of input and output port for this component */
-	of_coresight_get_ports(node, &pdata->nr_inport, &pdata->nr_outport);
+	of_coresight_get_ports(dev, node, &pdata->nr_inport, &pdata->nr_outport);
 
 	if (pdata->nr_outport) {
 		ret = of_coresight_alloc_memory(dev, pdata);
@@ -168,7 +180,7 @@ of_get_coresight_platform_data(struct device *dev,
 			 * No need to deal with input ports, processing for as
 			 * processing for output ports will deal with them.
 			 */
-			if (of_find_property(ep, "slave-mode", NULL))
+			if (of_coresight_ep_is_input(dev, ep))
 				continue;
 
 			outport = of_graph_ep_coresight_get_port_id(dev, ep);
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 8/8] dts: juno: Update coresight bindings for hw port
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 13:16   ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel
  Cc: mathieu.poirier, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Suzuki K Poulose,
	Liviu Dudau

Switch to updated coresight bindings for hw ports.

Cc: Sudeep Holla <sudeep.holla@arm.com>
Cc: Liviu Dudau <liviu.dudau@arm.com>
Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 arch/arm64/boot/dts/arm/juno-base.dtsi | 82 +++++++++++++++++++++++++---------
 arch/arm64/boot/dts/arm/juno.dts       |  5 ++-
 2 files changed, 63 insertions(+), 24 deletions(-)

diff --git a/arch/arm64/boot/dts/arm/juno-base.dtsi b/arch/arm64/boot/dts/arm/juno-base.dtsi
index eb749c5..33b41ba 100644
--- a/arch/arm64/boot/dts/arm/juno-base.dtsi
+++ b/arch/arm64/boot/dts/arm/juno-base.dtsi
@@ -122,15 +122,18 @@
 			port@0 {
 				reg = <0>;
 				etf0_in_port: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&main_funnel_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			/* output port */
 			port@1 {
-				reg = <0>;
+				reg = <1>;
 				etf0_out_port: endpoint {
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 		};
@@ -145,8 +148,9 @@
 		power-domains = <&scpi_devpd 0>;
 		port {
 			tpiu_in_port: endpoint {
-				slave-mode;
+				direction = <0>;
 				remote-endpoint = <&replicator_out_port0>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -168,23 +172,27 @@
 				reg = <0>;
 				main_funnel_out_port: endpoint {
 					remote-endpoint = <&etf0_in_port>;
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 
 			/* input ports */
 			port@1 {
-				reg = <0>;
+				reg = <1>;
 				main_funnel_in_port0: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster0_funnel_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			port@2 {
-				reg = <1>;
+				reg = <2>;
 				main_funnel_in_port1: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_funnel_out_port>;
+					coresight,hwid = <1>;
 				};
 			};
 		};
@@ -200,8 +208,9 @@
 		power-domains = <&scpi_devpd 0>;
 		port {
 			etr_in_port: endpoint {
-				slave-mode;
+				direction = <0>;
 				remote-endpoint = <&replicator_out_port1>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -217,6 +226,8 @@
 		power-domains = <&scpi_devpd 0>;
 		port {
 			stm_out_port: endpoint {
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -240,6 +251,8 @@
 		port {
 			cluster0_etm0_out_port: endpoint {
 				remote-endpoint = <&cluster0_funnel_in_port0>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -259,22 +272,26 @@
 				reg = <0>;
 				cluster0_funnel_out_port: endpoint {
 					remote-endpoint = <&main_funnel_in_port0>;
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 
 			port@1 {
-				reg = <0>;
+				reg = <1>;
 				cluster0_funnel_in_port0: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster0_etm0_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			port@2 {
-				reg = <1>;
+				reg = <2>;
 				cluster0_funnel_in_port1: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster0_etm1_out_port>;
+					coresight,hwid = <1>;
 				};
 			};
 		};
@@ -299,6 +316,8 @@
 		port {
 			cluster0_etm1_out_port: endpoint {
 				remote-endpoint = <&cluster0_funnel_in_port1>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -322,6 +341,8 @@
 		port {
 			cluster1_etm0_out_port: endpoint {
 				remote-endpoint = <&cluster1_funnel_in_port0>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -341,36 +362,42 @@
 				reg = <0>;
 				cluster1_funnel_out_port: endpoint {
 					remote-endpoint = <&main_funnel_in_port1>;
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 
 			port@1 {
-				reg = <0>;
+				reg = <1>;
 				cluster1_funnel_in_port0: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_etm0_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			port@2 {
-				reg = <1>;
+				reg = <2>;
 				cluster1_funnel_in_port1: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_etm1_out_port>;
+					coresight,hwid = <1>;
 				};
 			};
 			port@3 {
-				reg = <2>;
+				reg = <3>;
 				cluster1_funnel_in_port2: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_etm2_out_port>;
+					coresight,hwid = <2>;
 				};
 			};
 			port@4 {
-				reg = <3>;
+				reg = <4>;
 				cluster1_funnel_in_port3: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_etm3_out_port>;
+					coresight,hwid = <3>;
 				};
 			};
 		};
@@ -395,6 +422,8 @@
 		port {
 			cluster1_etm1_out_port: endpoint {
 				remote-endpoint = <&cluster1_funnel_in_port1>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -418,6 +447,8 @@
 		port {
 			cluster1_etm2_out_port: endpoint {
 				remote-endpoint = <&cluster1_funnel_in_port2>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -441,6 +472,8 @@
 		port {
 			cluster1_etm3_out_port: endpoint {
 				remote-endpoint = <&cluster1_funnel_in_port3>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -462,6 +495,8 @@
 				reg = <0>;
 				replicator_out_port0: endpoint {
 					remote-endpoint = <&tpiu_in_port>;
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 
@@ -469,14 +504,17 @@
 				reg = <1>;
 				replicator_out_port1: endpoint {
 					remote-endpoint = <&etr_in_port>;
+					coresight,hwid = <1>;
+					direction = <1>;
 				};
 			};
 
 			/* replicator input port */
 			port@2 {
-				reg = <0>;
+				reg = <2>;
 				replicator_in_port0: endpoint {
-					slave-mode;
+					direction = <0>;
+					coresight,hwid = <0>;
 				};
 			};
 		};
diff --git a/arch/arm64/boot/dts/arm/juno.dts b/arch/arm64/boot/dts/arm/juno.dts
index c9236c4..27b8036 100644
--- a/arch/arm64/boot/dts/arm/juno.dts
+++ b/arch/arm64/boot/dts/arm/juno.dts
@@ -260,10 +260,11 @@
 &main_funnel {
 	ports {
 		port@3 {
-			reg = <2>;
+			reg = <3>;
 			main_funnel_in_port2: endpoint {
-				slave-mode;
+				direction = <0>;
 				remote-endpoint = <&stm_out_port>;
+				coresight,hwid = <2>;
 			};
 		};
 	};
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* [RFC PATCH 8/8] dts: juno: Update coresight bindings for hw port
@ 2018-06-01 13:16   ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-01 13:16 UTC (permalink / raw)
  To: linux-arm-kernel

Switch to updated coresight bindings for hw ports.

Cc: Sudeep Holla <sudeep.holla@arm.com>
Cc: Liviu Dudau <liviu.dudau@arm.com>
Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
---
 arch/arm64/boot/dts/arm/juno-base.dtsi | 82 +++++++++++++++++++++++++---------
 arch/arm64/boot/dts/arm/juno.dts       |  5 ++-
 2 files changed, 63 insertions(+), 24 deletions(-)

diff --git a/arch/arm64/boot/dts/arm/juno-base.dtsi b/arch/arm64/boot/dts/arm/juno-base.dtsi
index eb749c5..33b41ba 100644
--- a/arch/arm64/boot/dts/arm/juno-base.dtsi
+++ b/arch/arm64/boot/dts/arm/juno-base.dtsi
@@ -122,15 +122,18 @@
 			port at 0 {
 				reg = <0>;
 				etf0_in_port: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&main_funnel_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			/* output port */
 			port at 1 {
-				reg = <0>;
+				reg = <1>;
 				etf0_out_port: endpoint {
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 		};
@@ -145,8 +148,9 @@
 		power-domains = <&scpi_devpd 0>;
 		port {
 			tpiu_in_port: endpoint {
-				slave-mode;
+				direction = <0>;
 				remote-endpoint = <&replicator_out_port0>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -168,23 +172,27 @@
 				reg = <0>;
 				main_funnel_out_port: endpoint {
 					remote-endpoint = <&etf0_in_port>;
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 
 			/* input ports */
 			port at 1 {
-				reg = <0>;
+				reg = <1>;
 				main_funnel_in_port0: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster0_funnel_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			port at 2 {
-				reg = <1>;
+				reg = <2>;
 				main_funnel_in_port1: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_funnel_out_port>;
+					coresight,hwid = <1>;
 				};
 			};
 		};
@@ -200,8 +208,9 @@
 		power-domains = <&scpi_devpd 0>;
 		port {
 			etr_in_port: endpoint {
-				slave-mode;
+				direction = <0>;
 				remote-endpoint = <&replicator_out_port1>;
+				coresight,hwid = <0>;
 			};
 		};
 	};
@@ -217,6 +226,8 @@
 		power-domains = <&scpi_devpd 0>;
 		port {
 			stm_out_port: endpoint {
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -240,6 +251,8 @@
 		port {
 			cluster0_etm0_out_port: endpoint {
 				remote-endpoint = <&cluster0_funnel_in_port0>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -259,22 +272,26 @@
 				reg = <0>;
 				cluster0_funnel_out_port: endpoint {
 					remote-endpoint = <&main_funnel_in_port0>;
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 
 			port at 1 {
-				reg = <0>;
+				reg = <1>;
 				cluster0_funnel_in_port0: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster0_etm0_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			port at 2 {
-				reg = <1>;
+				reg = <2>;
 				cluster0_funnel_in_port1: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster0_etm1_out_port>;
+					coresight,hwid = <1>;
 				};
 			};
 		};
@@ -299,6 +316,8 @@
 		port {
 			cluster0_etm1_out_port: endpoint {
 				remote-endpoint = <&cluster0_funnel_in_port1>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -322,6 +341,8 @@
 		port {
 			cluster1_etm0_out_port: endpoint {
 				remote-endpoint = <&cluster1_funnel_in_port0>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -341,36 +362,42 @@
 				reg = <0>;
 				cluster1_funnel_out_port: endpoint {
 					remote-endpoint = <&main_funnel_in_port1>;
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 
 			port at 1 {
-				reg = <0>;
+				reg = <1>;
 				cluster1_funnel_in_port0: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_etm0_out_port>;
+					coresight,hwid = <0>;
 				};
 			};
 
 			port at 2 {
-				reg = <1>;
+				reg = <2>;
 				cluster1_funnel_in_port1: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_etm1_out_port>;
+					coresight,hwid = <1>;
 				};
 			};
 			port at 3 {
-				reg = <2>;
+				reg = <3>;
 				cluster1_funnel_in_port2: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_etm2_out_port>;
+					coresight,hwid = <2>;
 				};
 			};
 			port at 4 {
-				reg = <3>;
+				reg = <4>;
 				cluster1_funnel_in_port3: endpoint {
-					slave-mode;
+					direction = <0>;
 					remote-endpoint = <&cluster1_etm3_out_port>;
+					coresight,hwid = <3>;
 				};
 			};
 		};
@@ -395,6 +422,8 @@
 		port {
 			cluster1_etm1_out_port: endpoint {
 				remote-endpoint = <&cluster1_funnel_in_port1>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -418,6 +447,8 @@
 		port {
 			cluster1_etm2_out_port: endpoint {
 				remote-endpoint = <&cluster1_funnel_in_port2>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -441,6 +472,8 @@
 		port {
 			cluster1_etm3_out_port: endpoint {
 				remote-endpoint = <&cluster1_funnel_in_port3>;
+				coresight,hwid = <0>;
+				direction = <1>;
 			};
 		};
 	};
@@ -462,6 +495,8 @@
 				reg = <0>;
 				replicator_out_port0: endpoint {
 					remote-endpoint = <&tpiu_in_port>;
+					coresight,hwid = <0>;
+					direction = <1>;
 				};
 			};
 
@@ -469,14 +504,17 @@
 				reg = <1>;
 				replicator_out_port1: endpoint {
 					remote-endpoint = <&etr_in_port>;
+					coresight,hwid = <1>;
+					direction = <1>;
 				};
 			};
 
 			/* replicator input port */
 			port at 2 {
-				reg = <0>;
+				reg = <2>;
 				replicator_in_port0: endpoint {
-					slave-mode;
+					direction = <0>;
+					coresight,hwid = <0>;
 				};
 			};
 		};
diff --git a/arch/arm64/boot/dts/arm/juno.dts b/arch/arm64/boot/dts/arm/juno.dts
index c9236c4..27b8036 100644
--- a/arch/arm64/boot/dts/arm/juno.dts
+++ b/arch/arm64/boot/dts/arm/juno.dts
@@ -260,10 +260,11 @@
 &main_funnel {
 	ports {
 		port at 3 {
-			reg = <2>;
+			reg = <3>;
 			main_funnel_in_port2: endpoint {
-				slave-mode;
+				direction = <0>;
 				remote-endpoint = <&stm_out_port>;
+				coresight,hwid = <2>;
 			};
 		};
 	};
-- 
2.7.4

^ permalink raw reply related	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 1/8] dts: binding: coresight: Document graph bindings
  2018-06-01 13:16   ` Suzuki K Poulose
@ 2018-06-01 16:14     ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 16:14 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: linux-arm-kernel, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree

On Fri, Jun 01, 2018 at 02:16:00PM +0100, Suzuki K Poulose wrote:
> Before we updat the bindings, document the current graph bindings

s/updat/update

> and usage of additional properties.
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  .../devicetree/bindings/arm/coresight.txt          | 28 ++++++++++++++++++----
>  1 file changed, 24 insertions(+), 4 deletions(-)
> 
> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
> index 15ac8e8..bd36e40 100644
> --- a/Documentation/devicetree/bindings/arm/coresight.txt
> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
> @@ -52,9 +52,7 @@ its hardware characteristcs.
>  	  clocks the core of that coresight component. The latter clock
>  	  is optional.
>  
> -	* port or ports: The representation of the component's port
> -	  layout using the generic DT graph presentation found in
> -	  "bindings/graph.txt".
> +	* port or ports: see "Graph bindings for Coresight" below
>  
>  * Additional required properties for System Trace Macrocells (STM):
>  	* reg: along with the physical base address and length of the register
> @@ -71,7 +69,7 @@ its hardware characteristcs.
>  	  AMBA markee):
>  		- "arm,coresight-replicator"
>  
> -	* port or ports: same as above.
> +	* port or ports: see "Graph bindings for Coresight" below.
>  
>  * Optional properties for ETM/PTMs:
>  
> @@ -86,6 +84,28 @@ its hardware characteristcs.
>  	* arm,buffer-size: size of contiguous buffer space for TMC ETR
>  	 (embedded trace router)
>  
> +Graph bindings for Coresight
> +-------------------------------
> +
> +Coresight components are interconnected to create a data path for the flow of
> +trace data generated from the "sources" to their collection points "sink". Each

Over 80 characters.

> +coresight component must describe the "input" and "output" connections.
> +The connections must be described via generic DT graph bindings as described
> +by the "bindings/graph.txt", where each "port" along with an "endpoint" component

Same here.

> +represents a hardware port and the connection.
> +
> +Since it is possible to have multiple connections for any coresight component with

And here.

> +a specific direction of data flow, each connection must define the following
> +properties to uniquely identify the connection details.
> +
> + * Direction of the data flow w.r.t the component :
> +   Each input port must have the following property defined at the "endpoint"
> +   for the port.
> +	"slave-mode"
> +
> + * Hardware Port number at the component:
> +     -  The hardware port number is assumed to be the address of the "port" component.

And here.

Moveover this patches doesn't apply to my next tree. 

> +
>  
>  Example:
>  
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 1/8] dts: binding: coresight: Document graph bindings
@ 2018-06-01 16:14     ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 16:14 UTC (permalink / raw)
  To: linux-arm-kernel

On Fri, Jun 01, 2018 at 02:16:00PM +0100, Suzuki K Poulose wrote:
> Before we updat the bindings, document the current graph bindings

s/updat/update

> and usage of additional properties.
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  .../devicetree/bindings/arm/coresight.txt          | 28 ++++++++++++++++++----
>  1 file changed, 24 insertions(+), 4 deletions(-)
> 
> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
> index 15ac8e8..bd36e40 100644
> --- a/Documentation/devicetree/bindings/arm/coresight.txt
> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
> @@ -52,9 +52,7 @@ its hardware characteristcs.
>  	  clocks the core of that coresight component. The latter clock
>  	  is optional.
>  
> -	* port or ports: The representation of the component's port
> -	  layout using the generic DT graph presentation found in
> -	  "bindings/graph.txt".
> +	* port or ports: see "Graph bindings for Coresight" below
>  
>  * Additional required properties for System Trace Macrocells (STM):
>  	* reg: along with the physical base address and length of the register
> @@ -71,7 +69,7 @@ its hardware characteristcs.
>  	  AMBA markee):
>  		- "arm,coresight-replicator"
>  
> -	* port or ports: same as above.
> +	* port or ports: see "Graph bindings for Coresight" below.
>  
>  * Optional properties for ETM/PTMs:
>  
> @@ -86,6 +84,28 @@ its hardware characteristcs.
>  	* arm,buffer-size: size of contiguous buffer space for TMC ETR
>  	 (embedded trace router)
>  
> +Graph bindings for Coresight
> +-------------------------------
> +
> +Coresight components are interconnected to create a data path for the flow of
> +trace data generated from the "sources" to their collection points "sink". Each

Over 80 characters.

> +coresight component must describe the "input" and "output" connections.
> +The connections must be described via generic DT graph bindings as described
> +by the "bindings/graph.txt", where each "port" along with an "endpoint" component

Same here.

> +represents a hardware port and the connection.
> +
> +Since it is possible to have multiple connections for any coresight component with

And here.

> +a specific direction of data flow, each connection must define the following
> +properties to uniquely identify the connection details.
> +
> + * Direction of the data flow w.r.t the component :
> +   Each input port must have the following property defined at the "endpoint"
> +   for the port.
> +	"slave-mode"
> +
> + * Hardware Port number at the component:
> +     -  The hardware port number is assumed to be the address of the "port" component.

And here.

Moveover this patches doesn't apply to my next tree. 

> +
>  
>  Example:
>  
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 2/8] coresight: Fix remote endpoint parsing
  2018-06-01 13:16   ` Suzuki K Poulose
@ 2018-06-01 19:38     ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 19:38 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: linux-arm-kernel, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree

On Fri, Jun 01, 2018 at 02:16:01PM +0100, Suzuki K Poulose wrote:
> When parsing the remote endpoint of an output port, we do :
>      rport = of_graph_get_remote_port(ep);
>      rparent = of_graph_get_remote_port_parent(ep);
> 
> and then parse the "remote_port" as if it was the remote endpoint,
> which is wrong. The code worked fine because we used endpoint number
> as the port number. Let us fix it and optimise a bit as:
> 
>      remote_ep = of_graph_get_remote_endpoint(ep);
>      if (remote_ep)
>         remote_parent = of_graph_get_port_parent(remote_ep);
> 
> and then, parse the remote_ep for the port/endpoint details.
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  drivers/hwtracing/coresight/of_coresight.c | 19 ++++++++++---------
>  1 file changed, 10 insertions(+), 9 deletions(-)
> 
> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
> index 7c37544..e0deab0 100644
> --- a/drivers/hwtracing/coresight/of_coresight.c
> +++ b/drivers/hwtracing/coresight/of_coresight.c
> @@ -128,7 +128,7 @@ of_get_coresight_platform_data(struct device *dev,
>  	struct device *rdev;
>  	struct device_node *ep = NULL;
>  	struct device_node *rparent = NULL;
> -	struct device_node *rport = NULL;
> +	struct device_node *rep = NULL;
>  
>  	pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL);
>  	if (!pdata)
> @@ -169,16 +169,17 @@ of_get_coresight_platform_data(struct device *dev,
>  			pdata->outports[i] = endpoint.port;
>  
>  			/*
> -			 * Get a handle on the remote port and parent
> -			 * attached to it.
> +			 * Get a handle on the remote endpoint and the device
> +			 * it is attached to.
>  			 */
> -			rparent = of_graph_get_remote_port_parent(ep);
> -			rport = of_graph_get_remote_port(ep);
> -
> -			if (!rparent || !rport)
> +			rep = of_graph_get_remote_endpoint(ep);
> +			if (!rep)
> +				continue;
> +			rparent = of_graph_get_port_parent(rep);
> +			if (!rparent)
>  				continue;
>  
> -			if (of_graph_parse_endpoint(rport, &rendpoint))
> +			if (of_graph_parse_endpoint(rep, &rendpoint))
>  				continue;

You are correct and I'm out to lunch.

>  
>  			rdev = of_coresight_get_endpoint_device(rparent);
> @@ -186,7 +187,7 @@ of_get_coresight_platform_data(struct device *dev,
>  				return ERR_PTR(-EPROBE_DEFER);
>  
>  			pdata->child_names[i] = dev_name(rdev);
> -			pdata->child_ports[i] = rendpoint.id;
> +			pdata->child_ports[i] = rendpoint.port;

You need to do a of_node_put() here for both rep and rparent.

>  
>  			i++;
>  		} while (ep);
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 2/8] coresight: Fix remote endpoint parsing
@ 2018-06-01 19:38     ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 19:38 UTC (permalink / raw)
  To: linux-arm-kernel

On Fri, Jun 01, 2018 at 02:16:01PM +0100, Suzuki K Poulose wrote:
> When parsing the remote endpoint of an output port, we do :
>      rport = of_graph_get_remote_port(ep);
>      rparent = of_graph_get_remote_port_parent(ep);
> 
> and then parse the "remote_port" as if it was the remote endpoint,
> which is wrong. The code worked fine because we used endpoint number
> as the port number. Let us fix it and optimise a bit as:
> 
>      remote_ep = of_graph_get_remote_endpoint(ep);
>      if (remote_ep)
>         remote_parent = of_graph_get_port_parent(remote_ep);
> 
> and then, parse the remote_ep for the port/endpoint details.
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  drivers/hwtracing/coresight/of_coresight.c | 19 ++++++++++---------
>  1 file changed, 10 insertions(+), 9 deletions(-)
> 
> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
> index 7c37544..e0deab0 100644
> --- a/drivers/hwtracing/coresight/of_coresight.c
> +++ b/drivers/hwtracing/coresight/of_coresight.c
> @@ -128,7 +128,7 @@ of_get_coresight_platform_data(struct device *dev,
>  	struct device *rdev;
>  	struct device_node *ep = NULL;
>  	struct device_node *rparent = NULL;
> -	struct device_node *rport = NULL;
> +	struct device_node *rep = NULL;
>  
>  	pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL);
>  	if (!pdata)
> @@ -169,16 +169,17 @@ of_get_coresight_platform_data(struct device *dev,
>  			pdata->outports[i] = endpoint.port;
>  
>  			/*
> -			 * Get a handle on the remote port and parent
> -			 * attached to it.
> +			 * Get a handle on the remote endpoint and the device
> +			 * it is attached to.
>  			 */
> -			rparent = of_graph_get_remote_port_parent(ep);
> -			rport = of_graph_get_remote_port(ep);
> -
> -			if (!rparent || !rport)
> +			rep = of_graph_get_remote_endpoint(ep);
> +			if (!rep)
> +				continue;
> +			rparent = of_graph_get_port_parent(rep);
> +			if (!rparent)
>  				continue;
>  
> -			if (of_graph_parse_endpoint(rport, &rendpoint))
> +			if (of_graph_parse_endpoint(rep, &rendpoint))
>  				continue;

You are correct and I'm out to lunch.

>  
>  			rdev = of_coresight_get_endpoint_device(rparent);
> @@ -186,7 +187,7 @@ of_get_coresight_platform_data(struct device *dev,
>  				return ERR_PTR(-EPROBE_DEFER);
>  
>  			pdata->child_names[i] = dev_name(rdev);
> -			pdata->child_ports[i] = rendpoint.id;
> +			pdata->child_ports[i] = rendpoint.port;

You need to do a of_node_put() here for both rep and rparent.

>  
>  			i++;
>  		} while (ep);
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 2/8] coresight: Fix remote endpoint parsing
  2018-06-01 19:38     ` Mathieu Poirier
@ 2018-06-01 19:46       ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 19:46 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: linux-arm-kernel, Sudeep Holla, Rob Herring, Mark Rutland,
	Frank Rowand, Matt Sealey, Charles Garcia-Tobin, John Horley,
	Mike Leach, coresight, Linux Kernel Mailing List, devicetree

On 1 June 2018 at 13:38, Mathieu Poirier <mathieu.poirier@linaro.org> wrote:
> On Fri, Jun 01, 2018 at 02:16:01PM +0100, Suzuki K Poulose wrote:
>> When parsing the remote endpoint of an output port, we do :
>>      rport = of_graph_get_remote_port(ep);
>>      rparent = of_graph_get_remote_port_parent(ep);
>>
>> and then parse the "remote_port" as if it was the remote endpoint,
>> which is wrong. The code worked fine because we used endpoint number
>> as the port number. Let us fix it and optimise a bit as:
>>
>>      remote_ep = of_graph_get_remote_endpoint(ep);
>>      if (remote_ep)
>>         remote_parent = of_graph_get_port_parent(remote_ep);
>>
>> and then, parse the remote_ep for the port/endpoint details.
>>
>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>> ---
>>  drivers/hwtracing/coresight/of_coresight.c | 19 ++++++++++---------
>>  1 file changed, 10 insertions(+), 9 deletions(-)
>>
>> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
>> index 7c37544..e0deab0 100644
>> --- a/drivers/hwtracing/coresight/of_coresight.c
>> +++ b/drivers/hwtracing/coresight/of_coresight.c
>> @@ -128,7 +128,7 @@ of_get_coresight_platform_data(struct device *dev,
>>       struct device *rdev;
>>       struct device_node *ep = NULL;
>>       struct device_node *rparent = NULL;
>> -     struct device_node *rport = NULL;
>> +     struct device_node *rep = NULL;
>>
>>       pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL);
>>       if (!pdata)
>> @@ -169,16 +169,17 @@ of_get_coresight_platform_data(struct device *dev,
>>                       pdata->outports[i] = endpoint.port;
>>
>>                       /*
>> -                      * Get a handle on the remote port and parent
>> -                      * attached to it.
>> +                      * Get a handle on the remote endpoint and the device
>> +                      * it is attached to.
>>                        */
>> -                     rparent = of_graph_get_remote_port_parent(ep);
>> -                     rport = of_graph_get_remote_port(ep);
>> -
>> -                     if (!rparent || !rport)
>> +                     rep = of_graph_get_remote_endpoint(ep);
>> +                     if (!rep)
>> +                             continue;
>> +                     rparent = of_graph_get_port_parent(rep);
>> +                     if (!rparent)
>>                               continue;
>>
>> -                     if (of_graph_parse_endpoint(rport, &rendpoint))
>> +                     if (of_graph_parse_endpoint(rep, &rendpoint))
>>                               continue;
>
> You are correct and I'm out to lunch.
>
>>
>>                       rdev = of_coresight_get_endpoint_device(rparent);
>> @@ -186,7 +187,7 @@ of_get_coresight_platform_data(struct device *dev,
>>                               return ERR_PTR(-EPROBE_DEFER);
>>
>>                       pdata->child_names[i] = dev_name(rdev);
>> -                     pdata->child_ports[i] = rendpoint.id;
>> +                     pdata->child_ports[i] = rendpoint.port;
>
> You need to do a of_node_put() here for both rep and rparent.

Same thing for the "continue" and error condition above.

>
>>
>>                       i++;
>>               } while (ep);
>> --
>> 2.7.4
>>

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 2/8] coresight: Fix remote endpoint parsing
@ 2018-06-01 19:46       ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 19:46 UTC (permalink / raw)
  To: linux-arm-kernel

On 1 June 2018 at 13:38, Mathieu Poirier <mathieu.poirier@linaro.org> wrote:
> On Fri, Jun 01, 2018 at 02:16:01PM +0100, Suzuki K Poulose wrote:
>> When parsing the remote endpoint of an output port, we do :
>>      rport = of_graph_get_remote_port(ep);
>>      rparent = of_graph_get_remote_port_parent(ep);
>>
>> and then parse the "remote_port" as if it was the remote endpoint,
>> which is wrong. The code worked fine because we used endpoint number
>> as the port number. Let us fix it and optimise a bit as:
>>
>>      remote_ep = of_graph_get_remote_endpoint(ep);
>>      if (remote_ep)
>>         remote_parent = of_graph_get_port_parent(remote_ep);
>>
>> and then, parse the remote_ep for the port/endpoint details.
>>
>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>> ---
>>  drivers/hwtracing/coresight/of_coresight.c | 19 ++++++++++---------
>>  1 file changed, 10 insertions(+), 9 deletions(-)
>>
>> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
>> index 7c37544..e0deab0 100644
>> --- a/drivers/hwtracing/coresight/of_coresight.c
>> +++ b/drivers/hwtracing/coresight/of_coresight.c
>> @@ -128,7 +128,7 @@ of_get_coresight_platform_data(struct device *dev,
>>       struct device *rdev;
>>       struct device_node *ep = NULL;
>>       struct device_node *rparent = NULL;
>> -     struct device_node *rport = NULL;
>> +     struct device_node *rep = NULL;
>>
>>       pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL);
>>       if (!pdata)
>> @@ -169,16 +169,17 @@ of_get_coresight_platform_data(struct device *dev,
>>                       pdata->outports[i] = endpoint.port;
>>
>>                       /*
>> -                      * Get a handle on the remote port and parent
>> -                      * attached to it.
>> +                      * Get a handle on the remote endpoint and the device
>> +                      * it is attached to.
>>                        */
>> -                     rparent = of_graph_get_remote_port_parent(ep);
>> -                     rport = of_graph_get_remote_port(ep);
>> -
>> -                     if (!rparent || !rport)
>> +                     rep = of_graph_get_remote_endpoint(ep);
>> +                     if (!rep)
>> +                             continue;
>> +                     rparent = of_graph_get_port_parent(rep);
>> +                     if (!rparent)
>>                               continue;
>>
>> -                     if (of_graph_parse_endpoint(rport, &rendpoint))
>> +                     if (of_graph_parse_endpoint(rep, &rendpoint))
>>                               continue;
>
> You are correct and I'm out to lunch.
>
>>
>>                       rdev = of_coresight_get_endpoint_device(rparent);
>> @@ -186,7 +187,7 @@ of_get_coresight_platform_data(struct device *dev,
>>                               return ERR_PTR(-EPROBE_DEFER);
>>
>>                       pdata->child_names[i] = dev_name(rdev);
>> -                     pdata->child_ports[i] = rendpoint.id;
>> +                     pdata->child_ports[i] = rendpoint.port;
>
> You need to do a of_node_put() here for both rep and rparent.

Same thing for the "continue" and error condition above.

>
>>
>>                       i++;
>>               } while (ep);
>> --
>> 2.7.4
>>

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-01 13:16   ` Suzuki K Poulose
@ 2018-06-01 20:26     ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 20:26 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: linux-arm-kernel, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree

On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
> The coresight drivers relied on default bindings for graph
> in DT, while reusing the "reg" field of the "ports" to indicate
> the actual hardware port number for the connections. However,
> with the rules getting stricter w.r.t to the address mismatch
> with the label, it is no longer possible to use the port address
> field for the hardware port number. Hence, we add an explicit
> property to denote the hardware port number, "coresight,hwid"
> which must be specified for each "endpoint".
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Cc: Sudeep Holla <sudeep.holla@arm.com>
> Cc: Rob Herring <robh@kernel.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>  drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>  2 files changed, 54 insertions(+), 18 deletions(-)
> 
> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
> index bd36e40..385581a 100644
> --- a/Documentation/devicetree/bindings/arm/coresight.txt
> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>  	"slave-mode"
>  
>   * Hardware Port number at the component:
> -     -  The hardware port number is assumed to be the address of the "port" component.
> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
> +   - Each "endpoint" must define the hardware port of the local end of the
> +     connection using the following property:
> +	"coresight,hwid" - 32bit integer, hardware port number at the local end.
> +
>  
>  
>  Example:
> @@ -120,6 +124,7 @@ Example:
>  			etb_in_port: endpoint@0 {
>  				slave-mode;
>  				remote-endpoint = <&replicator_out_port0>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -134,6 +139,7 @@ Example:
>  			tpiu_in_port: endpoint@0 {
>  				slave-mode;
>  				remote-endpoint = <&replicator_out_port1>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -154,6 +160,7 @@ Example:
>  				reg = <0>;
>  				replicator_out_port0: endpoint {
>  					remote-endpoint = <&etb_in_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
> @@ -161,15 +168,17 @@ Example:
>  				reg = <1>;
>  				replicator_out_port1: endpoint {
>  					remote-endpoint = <&tpiu_in_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  
>  			/* replicator input port */
>  			port@2 {
> -				reg = <0>;
> +				reg = <1>;
>  				replicator_in_port0: endpoint {
>  					slave-mode;
>  					remote-endpoint = <&funnel_out_port0>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  		};
> @@ -191,31 +200,35 @@ Example:
>  				funnel_out_port0: endpoint {
>  					remote-endpoint =
>  							<&replicator_in_port0>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			/* funnel input ports */
>  			port@1 {
> -				reg = <0>;
> +				reg = <1>;
>  				funnel_in_port0: endpoint {
>  					slave-mode;
>  					remote-endpoint = <&ptm0_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			port@2 {
> -				reg = <1>;
> +				reg = <2>;
>  				funnel_in_port1: endpoint {
>  					slave-mode;
>  					remote-endpoint = <&ptm1_out_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  
>  			port@3 {
> -				reg = <2>;
> +				reg = <3>;
>  				funnel_in_port2: endpoint {
>  					slave-mode;
>  					remote-endpoint = <&etm0_out_port>;
> +					coresight,hwid = <2>;
>  				};
>  			};
>  
> @@ -233,6 +246,7 @@ Example:
>  		port {
>  			ptm0_out_port: endpoint {
>  				remote-endpoint = <&funnel_in_port0>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -247,6 +261,7 @@ Example:
>  		port {
>  			ptm1_out_port: endpoint {
>  				remote-endpoint = <&funnel_in_port1>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -263,6 +278,7 @@ Example:
>  		port {
>  			stm_out_port: endpoint {
>  				remote-endpoint = <&main_funnel_in_port2>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
> index a3f3416..99d7a9c 100644
> --- a/drivers/hwtracing/coresight/of_coresight.c
> +++ b/drivers/hwtracing/coresight/of_coresight.c
> @@ -105,14 +105,37 @@ int of_coresight_get_cpu(const struct device_node *node)
>  }
>  EXPORT_SYMBOL_GPL(of_coresight_get_cpu);
>  
> +/*
> + * of_graph_ep_coresight_get_port_id : Get the hardware port number for the
> + * given endpoint device node. Prefer the explicit "coresight,hwid" property
> + * over the endpoint register id (obsolete bindings).
> + */
> +static int of_graph_ep_coresight_get_port_id(struct device *dev,
> +					     struct device_node *ep_node)


static int of_coresight_endpoint_get_port_id(struct device *dev,
					     struct device_node *ep_node)

I think that makes more sense since this function is only visible in this file.

> +{
> +	struct of_endpoint ep;
> +	int rc, port_id;
> +
> +
> +	if (!of_property_read_u32(ep_node, "coresight,hwid", &port_id))
> +		return port_id;
> +
> +	rc = of_graph_parse_endpoint(ep_node, &ep);
> +	if (rc)
> +		return rc;
> +	dev_warn_once(dev,
> +		      "ep%d: Mandatory \"coresight,hwid\" property missing."
> +		      " DT uses obsolete coresight bindings\n", ep.port);
> +	return ep.port;
> +}
> +
>  struct coresight_platform_data *
>  of_get_coresight_platform_data(struct device *dev,
>  			       const struct device_node *node)
>  {
> -	int ret = 0;
> +	int ret = 0, outport, inport;
>  	struct coresight_platform_data *pdata;
>  	struct coresight_connection *conn;
> -	struct of_endpoint endpoint, rendpoint;
>  	struct device *rdev;
>  	struct device_node *ep = NULL;
>  	struct device_node *rparent = NULL;
> @@ -148,14 +171,10 @@ of_get_coresight_platform_data(struct device *dev,
>  			if (of_find_property(ep, "slave-mode", NULL))
>  				continue;
>  
> -			/* Get a handle on the local endpoint */
> -			ret = of_graph_parse_endpoint(ep, &endpoint);
> -
> -			if (ret)
> +			outport = of_graph_ep_coresight_get_port_id(dev, ep);
> +			if (outport < 0)
>  				continue;
> -
> -			/* The local out port number */
> -			conn->outport = endpoint.port;
> +			conn->outport = outport;
>  
>  			/*
>  			 * Get a handle on the remote endpoint and the device
> @@ -168,15 +187,16 @@ of_get_coresight_platform_data(struct device *dev,
>  			if (!rparent)
>  				continue;
>  
> -			if (of_graph_parse_endpoint(rep, &rendpoint))
> -				continue;
> -
>  			rdev = of_coresight_get_endpoint_device(rparent);
>  			if (!rdev)
>  				return ERR_PTR(-EPROBE_DEFER);
>  
> +			inport = of_graph_ep_coresight_get_port_id(rdev, rep);
> +			if (inport < 0)
> +				continue;
> +
>  			conn->child_name = dev_name(rdev);
> -			conn->child_port = rendpoint.port;
> +			conn->child_port = inport;
>  			conn++;
>  		} while (ep);
>  	}
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-01 20:26     ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 20:26 UTC (permalink / raw)
  To: linux-arm-kernel

On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
> The coresight drivers relied on default bindings for graph
> in DT, while reusing the "reg" field of the "ports" to indicate
> the actual hardware port number for the connections. However,
> with the rules getting stricter w.r.t to the address mismatch
> with the label, it is no longer possible to use the port address
> field for the hardware port number. Hence, we add an explicit
> property to denote the hardware port number, "coresight,hwid"
> which must be specified for each "endpoint".
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Cc: Sudeep Holla <sudeep.holla@arm.com>
> Cc: Rob Herring <robh@kernel.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>  drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>  2 files changed, 54 insertions(+), 18 deletions(-)
> 
> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
> index bd36e40..385581a 100644
> --- a/Documentation/devicetree/bindings/arm/coresight.txt
> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>  	"slave-mode"
>  
>   * Hardware Port number at the component:
> -     -  The hardware port number is assumed to be the address of the "port" component.
> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
> +   - Each "endpoint" must define the hardware port of the local end of the
> +     connection using the following property:
> +	"coresight,hwid" - 32bit integer, hardware port number at the local end.
> +
>  
>  
>  Example:
> @@ -120,6 +124,7 @@ Example:
>  			etb_in_port: endpoint at 0 {
>  				slave-mode;
>  				remote-endpoint = <&replicator_out_port0>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -134,6 +139,7 @@ Example:
>  			tpiu_in_port: endpoint at 0 {
>  				slave-mode;
>  				remote-endpoint = <&replicator_out_port1>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -154,6 +160,7 @@ Example:
>  				reg = <0>;
>  				replicator_out_port0: endpoint {
>  					remote-endpoint = <&etb_in_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
> @@ -161,15 +168,17 @@ Example:
>  				reg = <1>;
>  				replicator_out_port1: endpoint {
>  					remote-endpoint = <&tpiu_in_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  
>  			/* replicator input port */
>  			port at 2 {
> -				reg = <0>;
> +				reg = <1>;
>  				replicator_in_port0: endpoint {
>  					slave-mode;
>  					remote-endpoint = <&funnel_out_port0>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  		};
> @@ -191,31 +200,35 @@ Example:
>  				funnel_out_port0: endpoint {
>  					remote-endpoint =
>  							<&replicator_in_port0>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			/* funnel input ports */
>  			port at 1 {
> -				reg = <0>;
> +				reg = <1>;
>  				funnel_in_port0: endpoint {
>  					slave-mode;
>  					remote-endpoint = <&ptm0_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			port at 2 {
> -				reg = <1>;
> +				reg = <2>;
>  				funnel_in_port1: endpoint {
>  					slave-mode;
>  					remote-endpoint = <&ptm1_out_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  
>  			port at 3 {
> -				reg = <2>;
> +				reg = <3>;
>  				funnel_in_port2: endpoint {
>  					slave-mode;
>  					remote-endpoint = <&etm0_out_port>;
> +					coresight,hwid = <2>;
>  				};
>  			};
>  
> @@ -233,6 +246,7 @@ Example:
>  		port {
>  			ptm0_out_port: endpoint {
>  				remote-endpoint = <&funnel_in_port0>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -247,6 +261,7 @@ Example:
>  		port {
>  			ptm1_out_port: endpoint {
>  				remote-endpoint = <&funnel_in_port1>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -263,6 +278,7 @@ Example:
>  		port {
>  			stm_out_port: endpoint {
>  				remote-endpoint = <&main_funnel_in_port2>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
> index a3f3416..99d7a9c 100644
> --- a/drivers/hwtracing/coresight/of_coresight.c
> +++ b/drivers/hwtracing/coresight/of_coresight.c
> @@ -105,14 +105,37 @@ int of_coresight_get_cpu(const struct device_node *node)
>  }
>  EXPORT_SYMBOL_GPL(of_coresight_get_cpu);
>  
> +/*
> + * of_graph_ep_coresight_get_port_id : Get the hardware port number for the
> + * given endpoint device node. Prefer the explicit "coresight,hwid" property
> + * over the endpoint register id (obsolete bindings).
> + */
> +static int of_graph_ep_coresight_get_port_id(struct device *dev,
> +					     struct device_node *ep_node)


static int of_coresight_endpoint_get_port_id(struct device *dev,
					     struct device_node *ep_node)

I think that makes more sense since this function is only visible in this file.

> +{
> +	struct of_endpoint ep;
> +	int rc, port_id;
> +
> +
> +	if (!of_property_read_u32(ep_node, "coresight,hwid", &port_id))
> +		return port_id;
> +
> +	rc = of_graph_parse_endpoint(ep_node, &ep);
> +	if (rc)
> +		return rc;
> +	dev_warn_once(dev,
> +		      "ep%d: Mandatory \"coresight,hwid\" property missing."
> +		      " DT uses obsolete coresight bindings\n", ep.port);
> +	return ep.port;
> +}
> +
>  struct coresight_platform_data *
>  of_get_coresight_platform_data(struct device *dev,
>  			       const struct device_node *node)
>  {
> -	int ret = 0;
> +	int ret = 0, outport, inport;
>  	struct coresight_platform_data *pdata;
>  	struct coresight_connection *conn;
> -	struct of_endpoint endpoint, rendpoint;
>  	struct device *rdev;
>  	struct device_node *ep = NULL;
>  	struct device_node *rparent = NULL;
> @@ -148,14 +171,10 @@ of_get_coresight_platform_data(struct device *dev,
>  			if (of_find_property(ep, "slave-mode", NULL))
>  				continue;
>  
> -			/* Get a handle on the local endpoint */
> -			ret = of_graph_parse_endpoint(ep, &endpoint);
> -
> -			if (ret)
> +			outport = of_graph_ep_coresight_get_port_id(dev, ep);
> +			if (outport < 0)
>  				continue;
> -
> -			/* The local out port number */
> -			conn->outport = endpoint.port;
> +			conn->outport = outport;
>  
>  			/*
>  			 * Get a handle on the remote endpoint and the device
> @@ -168,15 +187,16 @@ of_get_coresight_platform_data(struct device *dev,
>  			if (!rparent)
>  				continue;
>  
> -			if (of_graph_parse_endpoint(rep, &rendpoint))
> -				continue;
> -
>  			rdev = of_coresight_get_endpoint_device(rparent);
>  			if (!rdev)
>  				return ERR_PTR(-EPROBE_DEFER);
>  
> +			inport = of_graph_ep_coresight_get_port_id(rdev, rep);
> +			if (inport < 0)
> +				continue;
> +
>  			conn->child_name = dev_name(rdev);
> -			conn->child_port = rendpoint.port;
> +			conn->child_port = inport;
>  			conn++;
>  		} while (ep);
>  	}
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 7/8] dts: coresight: Define new bindings for direction of data flow
  2018-06-01 13:16   ` Suzuki K Poulose
@ 2018-06-01 20:39     ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 20:39 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: linux-arm-kernel, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree

On Fri, Jun 01, 2018 at 02:16:06PM +0100, Suzuki K Poulose wrote:
> So far we have relied on an undocumented property "slave-mode",
> to indicate if the given port is input or not. Since we are
> redefining the coresight bindings, define new property for the
> "direction" of data flow for a given connection endpoint in the
> device.
> 
> Each endpoint must define the following property.
> 
>  - "direction" : 0 => Port is input
> 		 1 => Port is output
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  drivers/hwtracing/coresight/of_coresight.c | 20 ++++++++++++++++----

You haven't documented the binding in bindings/arm/coresight.txt the same way
you did with "coresight,hwid".  I'm guessing you simply forgot to do a "git add"
on the file when preparing the patchset.

>  1 file changed, 16 insertions(+), 4 deletions(-)
> 
> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
> index 99d7a9c..63c1668 100644
> --- a/drivers/hwtracing/coresight/of_coresight.c
> +++ b/drivers/hwtracing/coresight/of_coresight.c
> @@ -52,7 +52,19 @@ of_coresight_get_endpoint_device(struct device_node *endpoint)
>  			       endpoint, of_dev_node_match);
>  }
>  
> -static void of_coresight_get_ports(const struct device_node *node,
> +static bool of_coresight_ep_is_input(struct device *dev, struct device_node *ep_node)

I suggested of_coresight_endpoint_get_port_id() in my review of 6/8.  I'm good
with either "ep" or "endpoint", as long as the names are consistent.

> +{
> +	u32 dir;
> +
> +	if (!of_property_read_u32(ep_node, "direction", &dir))
> +		return dir == 0;
> +
> +	dev_warn_once(dev, "Missing mandatory \"direction\" property!\n");
> +	return of_property_read_bool(ep_node, "slave-mode");
> +}
> +
> +static void of_coresight_get_ports(struct device *dev,
> +				   const struct device_node *node,
>  				   int *nr_inport, int *nr_outport)
>  {
>  	struct device_node *ep = NULL;
> @@ -63,7 +75,7 @@ static void of_coresight_get_ports(const struct device_node *node,
>  		if (!ep)
>  			break;
>  
> -		if (of_property_read_bool(ep, "slave-mode"))
> +		if (of_coresight_ep_is_input(dev, ep))
>  			in++;
>  		else
>  			out++;
> @@ -149,7 +161,7 @@ of_get_coresight_platform_data(struct device *dev,
>  	pdata->name = dev_name(dev);
>  
>  	/* Get the number of input and output port for this component */
> -	of_coresight_get_ports(node, &pdata->nr_inport, &pdata->nr_outport);
> +	of_coresight_get_ports(dev, node, &pdata->nr_inport, &pdata->nr_outport);
>  
>  	if (pdata->nr_outport) {
>  		ret = of_coresight_alloc_memory(dev, pdata);
> @@ -168,7 +180,7 @@ of_get_coresight_platform_data(struct device *dev,
>  			 * No need to deal with input ports, processing for as
>  			 * processing for output ports will deal with them.
>  			 */
> -			if (of_find_property(ep, "slave-mode", NULL))
> +			if (of_coresight_ep_is_input(dev, ep))
>  				continue;
>  
>  			outport = of_graph_ep_coresight_get_port_id(dev, ep);
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 7/8] dts: coresight: Define new bindings for direction of data flow
@ 2018-06-01 20:39     ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 20:39 UTC (permalink / raw)
  To: linux-arm-kernel

On Fri, Jun 01, 2018 at 02:16:06PM +0100, Suzuki K Poulose wrote:
> So far we have relied on an undocumented property "slave-mode",
> to indicate if the given port is input or not. Since we are
> redefining the coresight bindings, define new property for the
> "direction" of data flow for a given connection endpoint in the
> device.
> 
> Each endpoint must define the following property.
> 
>  - "direction" : 0 => Port is input
> 		 1 => Port is output
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  drivers/hwtracing/coresight/of_coresight.c | 20 ++++++++++++++++----

You haven't documented the binding in bindings/arm/coresight.txt the same way
you did with "coresight,hwid".  I'm guessing you simply forgot to do a "git add"
on the file when preparing the patchset.

>  1 file changed, 16 insertions(+), 4 deletions(-)
> 
> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
> index 99d7a9c..63c1668 100644
> --- a/drivers/hwtracing/coresight/of_coresight.c
> +++ b/drivers/hwtracing/coresight/of_coresight.c
> @@ -52,7 +52,19 @@ of_coresight_get_endpoint_device(struct device_node *endpoint)
>  			       endpoint, of_dev_node_match);
>  }
>  
> -static void of_coresight_get_ports(const struct device_node *node,
> +static bool of_coresight_ep_is_input(struct device *dev, struct device_node *ep_node)

I suggested of_coresight_endpoint_get_port_id() in my review of 6/8.  I'm good
with either "ep" or "endpoint", as long as the names are consistent.

> +{
> +	u32 dir;
> +
> +	if (!of_property_read_u32(ep_node, "direction", &dir))
> +		return dir == 0;
> +
> +	dev_warn_once(dev, "Missing mandatory \"direction\" property!\n");
> +	return of_property_read_bool(ep_node, "slave-mode");
> +}
> +
> +static void of_coresight_get_ports(struct device *dev,
> +				   const struct device_node *node,
>  				   int *nr_inport, int *nr_outport)
>  {
>  	struct device_node *ep = NULL;
> @@ -63,7 +75,7 @@ static void of_coresight_get_ports(const struct device_node *node,
>  		if (!ep)
>  			break;
>  
> -		if (of_property_read_bool(ep, "slave-mode"))
> +		if (of_coresight_ep_is_input(dev, ep))
>  			in++;
>  		else
>  			out++;
> @@ -149,7 +161,7 @@ of_get_coresight_platform_data(struct device *dev,
>  	pdata->name = dev_name(dev);
>  
>  	/* Get the number of input and output port for this component */
> -	of_coresight_get_ports(node, &pdata->nr_inport, &pdata->nr_outport);
> +	of_coresight_get_ports(dev, node, &pdata->nr_inport, &pdata->nr_outport);
>  
>  	if (pdata->nr_outport) {
>  		ret = of_coresight_alloc_memory(dev, pdata);
> @@ -168,7 +180,7 @@ of_get_coresight_platform_data(struct device *dev,
>  			 * No need to deal with input ports, processing for as
>  			 * processing for output ports will deal with them.
>  			 */
> -			if (of_find_property(ep, "slave-mode", NULL))
> +			if (of_coresight_ep_is_input(dev, ep))
>  				continue;
>  
>  			outport = of_graph_ep_coresight_get_port_id(dev, ep);
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 8/8] dts: juno: Update coresight bindings for hw port
  2018-06-01 13:16   ` Suzuki K Poulose
@ 2018-06-01 20:59     ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 20:59 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: linux-arm-kernel, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree, Liviu Dudau

On Fri, Jun 01, 2018 at 02:16:07PM +0100, Suzuki K Poulose wrote:
> Switch to updated coresight bindings for hw ports.
> 
> Cc: Sudeep Holla <sudeep.holla@arm.com>
> Cc: Liviu Dudau <liviu.dudau@arm.com>
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>

Reviewed-and-tested-by: Mathieu Poirier <mathieu.poirier@linaro.org>

> ---
>  arch/arm64/boot/dts/arm/juno-base.dtsi | 82 +++++++++++++++++++++++++---------
>  arch/arm64/boot/dts/arm/juno.dts       |  5 ++-
>  2 files changed, 63 insertions(+), 24 deletions(-)
> 
> diff --git a/arch/arm64/boot/dts/arm/juno-base.dtsi b/arch/arm64/boot/dts/arm/juno-base.dtsi
> index eb749c5..33b41ba 100644
> --- a/arch/arm64/boot/dts/arm/juno-base.dtsi
> +++ b/arch/arm64/boot/dts/arm/juno-base.dtsi
> @@ -122,15 +122,18 @@
>  			port@0 {
>  				reg = <0>;
>  				etf0_in_port: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&main_funnel_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			/* output port */
>  			port@1 {
> -				reg = <0>;
> +				reg = <1>;
>  				etf0_out_port: endpoint {
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  		};
> @@ -145,8 +148,9 @@
>  		power-domains = <&scpi_devpd 0>;
>  		port {
>  			tpiu_in_port: endpoint {
> -				slave-mode;
> +				direction = <0>;
>  				remote-endpoint = <&replicator_out_port0>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -168,23 +172,27 @@
>  				reg = <0>;
>  				main_funnel_out_port: endpoint {
>  					remote-endpoint = <&etf0_in_port>;
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  
>  			/* input ports */
>  			port@1 {
> -				reg = <0>;
> +				reg = <1>;
>  				main_funnel_in_port0: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster0_funnel_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			port@2 {
> -				reg = <1>;
> +				reg = <2>;
>  				main_funnel_in_port1: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_funnel_out_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  		};
> @@ -200,8 +208,9 @@
>  		power-domains = <&scpi_devpd 0>;
>  		port {
>  			etr_in_port: endpoint {
> -				slave-mode;
> +				direction = <0>;
>  				remote-endpoint = <&replicator_out_port1>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -217,6 +226,8 @@
>  		power-domains = <&scpi_devpd 0>;
>  		port {
>  			stm_out_port: endpoint {
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -240,6 +251,8 @@
>  		port {
>  			cluster0_etm0_out_port: endpoint {
>  				remote-endpoint = <&cluster0_funnel_in_port0>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -259,22 +272,26 @@
>  				reg = <0>;
>  				cluster0_funnel_out_port: endpoint {
>  					remote-endpoint = <&main_funnel_in_port0>;
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  
>  			port@1 {
> -				reg = <0>;
> +				reg = <1>;
>  				cluster0_funnel_in_port0: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster0_etm0_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			port@2 {
> -				reg = <1>;
> +				reg = <2>;
>  				cluster0_funnel_in_port1: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster0_etm1_out_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  		};
> @@ -299,6 +316,8 @@
>  		port {
>  			cluster0_etm1_out_port: endpoint {
>  				remote-endpoint = <&cluster0_funnel_in_port1>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -322,6 +341,8 @@
>  		port {
>  			cluster1_etm0_out_port: endpoint {
>  				remote-endpoint = <&cluster1_funnel_in_port0>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -341,36 +362,42 @@
>  				reg = <0>;
>  				cluster1_funnel_out_port: endpoint {
>  					remote-endpoint = <&main_funnel_in_port1>;
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  
>  			port@1 {
> -				reg = <0>;
> +				reg = <1>;
>  				cluster1_funnel_in_port0: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_etm0_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			port@2 {
> -				reg = <1>;
> +				reg = <2>;
>  				cluster1_funnel_in_port1: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_etm1_out_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  			port@3 {
> -				reg = <2>;
> +				reg = <3>;
>  				cluster1_funnel_in_port2: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_etm2_out_port>;
> +					coresight,hwid = <2>;
>  				};
>  			};
>  			port@4 {
> -				reg = <3>;
> +				reg = <4>;
>  				cluster1_funnel_in_port3: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_etm3_out_port>;
> +					coresight,hwid = <3>;
>  				};
>  			};
>  		};
> @@ -395,6 +422,8 @@
>  		port {
>  			cluster1_etm1_out_port: endpoint {
>  				remote-endpoint = <&cluster1_funnel_in_port1>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -418,6 +447,8 @@
>  		port {
>  			cluster1_etm2_out_port: endpoint {
>  				remote-endpoint = <&cluster1_funnel_in_port2>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -441,6 +472,8 @@
>  		port {
>  			cluster1_etm3_out_port: endpoint {
>  				remote-endpoint = <&cluster1_funnel_in_port3>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -462,6 +495,8 @@
>  				reg = <0>;
>  				replicator_out_port0: endpoint {
>  					remote-endpoint = <&tpiu_in_port>;
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  
> @@ -469,14 +504,17 @@
>  				reg = <1>;
>  				replicator_out_port1: endpoint {
>  					remote-endpoint = <&etr_in_port>;
> +					coresight,hwid = <1>;
> +					direction = <1>;
>  				};
>  			};
>  
>  			/* replicator input port */
>  			port@2 {
> -				reg = <0>;
> +				reg = <2>;
>  				replicator_in_port0: endpoint {
> -					slave-mode;
> +					direction = <0>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  		};
> diff --git a/arch/arm64/boot/dts/arm/juno.dts b/arch/arm64/boot/dts/arm/juno.dts
> index c9236c4..27b8036 100644
> --- a/arch/arm64/boot/dts/arm/juno.dts
> +++ b/arch/arm64/boot/dts/arm/juno.dts
> @@ -260,10 +260,11 @@
>  &main_funnel {
>  	ports {
>  		port@3 {
> -			reg = <2>;
> +			reg = <3>;
>  			main_funnel_in_port2: endpoint {
> -				slave-mode;
> +				direction = <0>;
>  				remote-endpoint = <&stm_out_port>;
> +				coresight,hwid = <2>;
>  			};
>  		};
>  	};
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 8/8] dts: juno: Update coresight bindings for hw port
@ 2018-06-01 20:59     ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 20:59 UTC (permalink / raw)
  To: linux-arm-kernel

On Fri, Jun 01, 2018 at 02:16:07PM +0100, Suzuki K Poulose wrote:
> Switch to updated coresight bindings for hw ports.
> 
> Cc: Sudeep Holla <sudeep.holla@arm.com>
> Cc: Liviu Dudau <liviu.dudau@arm.com>
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>

Reviewed-and-tested-by: Mathieu Poirier <mathieu.poirier@linaro.org>

> ---
>  arch/arm64/boot/dts/arm/juno-base.dtsi | 82 +++++++++++++++++++++++++---------
>  arch/arm64/boot/dts/arm/juno.dts       |  5 ++-
>  2 files changed, 63 insertions(+), 24 deletions(-)
> 
> diff --git a/arch/arm64/boot/dts/arm/juno-base.dtsi b/arch/arm64/boot/dts/arm/juno-base.dtsi
> index eb749c5..33b41ba 100644
> --- a/arch/arm64/boot/dts/arm/juno-base.dtsi
> +++ b/arch/arm64/boot/dts/arm/juno-base.dtsi
> @@ -122,15 +122,18 @@
>  			port at 0 {
>  				reg = <0>;
>  				etf0_in_port: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&main_funnel_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			/* output port */
>  			port at 1 {
> -				reg = <0>;
> +				reg = <1>;
>  				etf0_out_port: endpoint {
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  		};
> @@ -145,8 +148,9 @@
>  		power-domains = <&scpi_devpd 0>;
>  		port {
>  			tpiu_in_port: endpoint {
> -				slave-mode;
> +				direction = <0>;
>  				remote-endpoint = <&replicator_out_port0>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -168,23 +172,27 @@
>  				reg = <0>;
>  				main_funnel_out_port: endpoint {
>  					remote-endpoint = <&etf0_in_port>;
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  
>  			/* input ports */
>  			port at 1 {
> -				reg = <0>;
> +				reg = <1>;
>  				main_funnel_in_port0: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster0_funnel_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			port at 2 {
> -				reg = <1>;
> +				reg = <2>;
>  				main_funnel_in_port1: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_funnel_out_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  		};
> @@ -200,8 +208,9 @@
>  		power-domains = <&scpi_devpd 0>;
>  		port {
>  			etr_in_port: endpoint {
> -				slave-mode;
> +				direction = <0>;
>  				remote-endpoint = <&replicator_out_port1>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -217,6 +226,8 @@
>  		power-domains = <&scpi_devpd 0>;
>  		port {
>  			stm_out_port: endpoint {
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -240,6 +251,8 @@
>  		port {
>  			cluster0_etm0_out_port: endpoint {
>  				remote-endpoint = <&cluster0_funnel_in_port0>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -259,22 +272,26 @@
>  				reg = <0>;
>  				cluster0_funnel_out_port: endpoint {
>  					remote-endpoint = <&main_funnel_in_port0>;
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  
>  			port at 1 {
> -				reg = <0>;
> +				reg = <1>;
>  				cluster0_funnel_in_port0: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster0_etm0_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			port at 2 {
> -				reg = <1>;
> +				reg = <2>;
>  				cluster0_funnel_in_port1: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster0_etm1_out_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  		};
> @@ -299,6 +316,8 @@
>  		port {
>  			cluster0_etm1_out_port: endpoint {
>  				remote-endpoint = <&cluster0_funnel_in_port1>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -322,6 +341,8 @@
>  		port {
>  			cluster1_etm0_out_port: endpoint {
>  				remote-endpoint = <&cluster1_funnel_in_port0>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -341,36 +362,42 @@
>  				reg = <0>;
>  				cluster1_funnel_out_port: endpoint {
>  					remote-endpoint = <&main_funnel_in_port1>;
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  
>  			port at 1 {
> -				reg = <0>;
> +				reg = <1>;
>  				cluster1_funnel_in_port0: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_etm0_out_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
>  			port at 2 {
> -				reg = <1>;
> +				reg = <2>;
>  				cluster1_funnel_in_port1: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_etm1_out_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  			port at 3 {
> -				reg = <2>;
> +				reg = <3>;
>  				cluster1_funnel_in_port2: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_etm2_out_port>;
> +					coresight,hwid = <2>;
>  				};
>  			};
>  			port at 4 {
> -				reg = <3>;
> +				reg = <4>;
>  				cluster1_funnel_in_port3: endpoint {
> -					slave-mode;
> +					direction = <0>;
>  					remote-endpoint = <&cluster1_etm3_out_port>;
> +					coresight,hwid = <3>;
>  				};
>  			};
>  		};
> @@ -395,6 +422,8 @@
>  		port {
>  			cluster1_etm1_out_port: endpoint {
>  				remote-endpoint = <&cluster1_funnel_in_port1>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -418,6 +447,8 @@
>  		port {
>  			cluster1_etm2_out_port: endpoint {
>  				remote-endpoint = <&cluster1_funnel_in_port2>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -441,6 +472,8 @@
>  		port {
>  			cluster1_etm3_out_port: endpoint {
>  				remote-endpoint = <&cluster1_funnel_in_port3>;
> +				coresight,hwid = <0>;
> +				direction = <1>;
>  			};
>  		};
>  	};
> @@ -462,6 +495,8 @@
>  				reg = <0>;
>  				replicator_out_port0: endpoint {
>  					remote-endpoint = <&tpiu_in_port>;
> +					coresight,hwid = <0>;
> +					direction = <1>;
>  				};
>  			};
>  
> @@ -469,14 +504,17 @@
>  				reg = <1>;
>  				replicator_out_port1: endpoint {
>  					remote-endpoint = <&etr_in_port>;
> +					coresight,hwid = <1>;
> +					direction = <1>;
>  				};
>  			};
>  
>  			/* replicator input port */
>  			port at 2 {
> -				reg = <0>;
> +				reg = <2>;
>  				replicator_in_port0: endpoint {
> -					slave-mode;
> +					direction = <0>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  		};
> diff --git a/arch/arm64/boot/dts/arm/juno.dts b/arch/arm64/boot/dts/arm/juno.dts
> index c9236c4..27b8036 100644
> --- a/arch/arm64/boot/dts/arm/juno.dts
> +++ b/arch/arm64/boot/dts/arm/juno.dts
> @@ -260,10 +260,11 @@
>  &main_funnel {
>  	ports {
>  		port at 3 {
> -			reg = <2>;
> +			reg = <3>;
>  			main_funnel_in_port2: endpoint {
> -				slave-mode;
> +				direction = <0>;
>  				remote-endpoint = <&stm_out_port>;
> +				coresight,hwid = <2>;
>  			};
>  		};
>  	};
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 0/8] coresight: Update device tree bindings
  2018-06-01 13:15 ` Suzuki K Poulose
@ 2018-06-01 21:04   ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 21:04 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: linux-arm-kernel, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree

On Fri, Jun 01, 2018 at 02:15:59PM +0100, Suzuki K Poulose wrote:
> Coresight uses DT graph bindings to describe the connections of the
> components. However we have some undocumented usage of the bindings
> to describe some of the properties of the connections.
> 
> The coresight driver needs to know the hardware ports invovled
> in the connection and the direction of data flow to effectively
> manage the trace sessions. So far we have relied on the "port"
> address (as described by the generic graph bindings) to represent
> the hardware port of the component for a connection.
> 
> The hardware uses separate numbering scheme for input and output
> ports, which implies, we could have two different (input and output)
> ports with the same port number. This could create problems in the
> graph bindings where the label of the port wouldn't match the address.
> 
> e.g, with the existing bindings we get :
> 
> 	port@0{				// Output port 0
> 		reg = <0>;
> 		...
> 	};
> 
> 	port@1{
> 		reg = <0>;		// Input port 0
> 		endpoint {
> 			slave-mode;
> 			...
> 		};
> 	};
> 
> With the new enforcement in the DT rules, mismatches in label and address
> are not allowed (as see in the case for port@1). So, we need a new mechanism
> to describe the hardware port number reliably.
> 
> Also, we relied on an undocumented "slave-mode" property (see the above
> example) to indicate if the port is an input port. Let us formalise and
> switch to a new property to describe the direction of data flow.
> 
> There were three options considered for the hardware port number scheme:
> 
>  1) Use natural ordering in the DT to infer the hardware port number.
>   i.e, Mandate that the all ports are listed in the DT and in the ascending
>   order for each class (input and output respectively).
>    Pros :
>       - We don't need new properties and if the existing DTS list them in
>         order (which most of them do), they work out of the box.
>    Cons :
>       - We must list all the ports even if the system cannot/shouldn't use
>         it.
>       - It is prone to human errors (if the order is not kept).
> 
>  2) Use an explicit property to list both the direction and the hw port
>     number and direction. Define "coresight,hwid" as 2 member array of u32,
>     where the members are port number and the direction respectively.
> 	e.g
> 
> 	port@0{
> 		reg = <0>;
> 		endpoint {
> 			coresight,hwid = <0 1>;	// Port # 0, Output
> 		}
> 	};
> 
> 	port@1{
> 		reg = <1>;
> 		endpoint {
> 			coresight,hwid = <0 0>;	// Port # 0, Input
> 		};
> 	};
> 
> 	Pros:
> 	  - The bindings are formal but not so reader friendly and could potentially
> 	    lead to human errors.
> 	Cons:
> 	  - Backward compatiblity is lost.
>  3) Use explicit properties (implemented in the series) for the hardware
>     port id and direction. We define a new property "coresight,hwid" for
>     each endpoint in coresight devices to specify the hardware port number
>     explicitly. Also use a separate property "direction" to specify the
>     direction of the data flow.
> 
> 	e.g,
> 
> 	port@0{
> 		reg = <0>;
> 		endpoint {
> 			direction = <1>;	// Output
> 			coresight,hwid = <0>;	// Port # 0
> 		}
> 	};
> 
> 	port@1{
> 		reg = <1>;
> 		endpoint {
> 			direction = <0>;	// Input
> 			coresight,hwid = <0>;	// Port # 0
> 		};
> 	};
> 
>     Pros:
>        - The bindings are formal and reader friendly, and less prone to errors.
>     Cons:
>        - Backward compatibility is lost.
> 
> 
> This series achieves implements Option (3) listed above while still retaining
> the backward compatibility. The driver now issues a warning (once) when it
> encounters the old bindings.
> It also cleans up the platform parsing code to reduce the memory usage by
> reusing the platform description. The series also includes the
> changes for Juno platform as an example. If there are no objections
> to the approach, I could post the series, converting all the
> in-kernel DTS to the new binding.
> 
> Suzuki K Poulose (8):
>   dts: binding: coresight: Document graph bindings
>   coresight: Fix remote endpoint parsing
>   coresight: Cleanup platform description data
>   coresight: platform: Cleanup coresight connection handling
>   coresight: Handle errors in finding input/output ports
>   dts: coresight: Clean up the device tree graph bindings
>   dts: coresight: Define new bindings for direction of data flow
>   dts: juno: Update coresight bindings for hw port
> 
>  .../devicetree/bindings/arm/coresight.txt          |  52 ++++++++--
>  arch/arm64/boot/dts/arm/juno-base.dtsi             |  82 +++++++++++----
>  arch/arm64/boot/dts/arm/juno.dts                   |   5 +-
>  drivers/hwtracing/coresight/coresight.c            |  28 ++----
>  drivers/hwtracing/coresight/of_coresight.c         | 111 ++++++++++++---------
>  include/linux/coresight.h                          |  11 +-
>  6 files changed, 181 insertions(+), 108 deletions(-)

Aside from the comments I've already posted I'm pretty much good with this set.
Please rebase the next revision on my "next" branch and run checkpatch.pl on the
set.  Patch 6/8 and 7/8 are generating warnings.

Thanks,
Mathieu

> 
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 0/8] coresight: Update device tree bindings
@ 2018-06-01 21:04   ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-01 21:04 UTC (permalink / raw)
  To: linux-arm-kernel

On Fri, Jun 01, 2018 at 02:15:59PM +0100, Suzuki K Poulose wrote:
> Coresight uses DT graph bindings to describe the connections of the
> components. However we have some undocumented usage of the bindings
> to describe some of the properties of the connections.
> 
> The coresight driver needs to know the hardware ports invovled
> in the connection and the direction of data flow to effectively
> manage the trace sessions. So far we have relied on the "port"
> address (as described by the generic graph bindings) to represent
> the hardware port of the component for a connection.
> 
> The hardware uses separate numbering scheme for input and output
> ports, which implies, we could have two different (input and output)
> ports with the same port number. This could create problems in the
> graph bindings where the label of the port wouldn't match the address.
> 
> e.g, with the existing bindings we get :
> 
> 	port at 0{				// Output port 0
> 		reg = <0>;
> 		...
> 	};
> 
> 	port at 1{
> 		reg = <0>;		// Input port 0
> 		endpoint {
> 			slave-mode;
> 			...
> 		};
> 	};
> 
> With the new enforcement in the DT rules, mismatches in label and address
> are not allowed (as see in the case for port at 1). So, we need a new mechanism
> to describe the hardware port number reliably.
> 
> Also, we relied on an undocumented "slave-mode" property (see the above
> example) to indicate if the port is an input port. Let us formalise and
> switch to a new property to describe the direction of data flow.
> 
> There were three options considered for the hardware port number scheme:
> 
>  1) Use natural ordering in the DT to infer the hardware port number.
>   i.e, Mandate that the all ports are listed in the DT and in the ascending
>   order for each class (input and output respectively).
>    Pros :
>       - We don't need new properties and if the existing DTS list them in
>         order (which most of them do), they work out of the box.
>    Cons :
>       - We must list all the ports even if the system cannot/shouldn't use
>         it.
>       - It is prone to human errors (if the order is not kept).
> 
>  2) Use an explicit property to list both the direction and the hw port
>     number and direction. Define "coresight,hwid" as 2 member array of u32,
>     where the members are port number and the direction respectively.
> 	e.g
> 
> 	port at 0{
> 		reg = <0>;
> 		endpoint {
> 			coresight,hwid = <0 1>;	// Port # 0, Output
> 		}
> 	};
> 
> 	port at 1{
> 		reg = <1>;
> 		endpoint {
> 			coresight,hwid = <0 0>;	// Port # 0, Input
> 		};
> 	};
> 
> 	Pros:
> 	  - The bindings are formal but not so reader friendly and could potentially
> 	    lead to human errors.
> 	Cons:
> 	  - Backward compatiblity is lost.
>  3) Use explicit properties (implemented in the series) for the hardware
>     port id and direction. We define a new property "coresight,hwid" for
>     each endpoint in coresight devices to specify the hardware port number
>     explicitly. Also use a separate property "direction" to specify the
>     direction of the data flow.
> 
> 	e.g,
> 
> 	port at 0{
> 		reg = <0>;
> 		endpoint {
> 			direction = <1>;	// Output
> 			coresight,hwid = <0>;	// Port # 0
> 		}
> 	};
> 
> 	port at 1{
> 		reg = <1>;
> 		endpoint {
> 			direction = <0>;	// Input
> 			coresight,hwid = <0>;	// Port # 0
> 		};
> 	};
> 
>     Pros:
>        - The bindings are formal and reader friendly, and less prone to errors.
>     Cons:
>        - Backward compatibility is lost.
> 
> 
> This series achieves implements Option (3) listed above while still retaining
> the backward compatibility. The driver now issues a warning (once) when it
> encounters the old bindings.
> It also cleans up the platform parsing code to reduce the memory usage by
> reusing the platform description. The series also includes the
> changes for Juno platform as an example. If there are no objections
> to the approach, I could post the series, converting all the
> in-kernel DTS to the new binding.
> 
> Suzuki K Poulose (8):
>   dts: binding: coresight: Document graph bindings
>   coresight: Fix remote endpoint parsing
>   coresight: Cleanup platform description data
>   coresight: platform: Cleanup coresight connection handling
>   coresight: Handle errors in finding input/output ports
>   dts: coresight: Clean up the device tree graph bindings
>   dts: coresight: Define new bindings for direction of data flow
>   dts: juno: Update coresight bindings for hw port
> 
>  .../devicetree/bindings/arm/coresight.txt          |  52 ++++++++--
>  arch/arm64/boot/dts/arm/juno-base.dtsi             |  82 +++++++++++----
>  arch/arm64/boot/dts/arm/juno.dts                   |   5 +-
>  drivers/hwtracing/coresight/coresight.c            |  28 ++----
>  drivers/hwtracing/coresight/of_coresight.c         | 111 ++++++++++++---------
>  include/linux/coresight.h                          |  11 +-
>  6 files changed, 181 insertions(+), 108 deletions(-)

Aside from the comments I've already posted I'm pretty much good with this set.
Please rebase the next revision on my "next" branch and run checkpatch.pl on the
set.  Patch 6/8 and 7/8 are generating warnings.

Thanks,
Mathieu

> 
> -- 
> 2.7.4
> 

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 2/8] coresight: Fix remote endpoint parsing
  2018-06-01 19:46       ` Mathieu Poirier
@ 2018-06-04 10:34         ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-04 10:34 UTC (permalink / raw)
  To: Mathieu Poirier
  Cc: linux-arm-kernel, Sudeep Holla, Rob Herring, Mark Rutland,
	Frank Rowand, Matt Sealey, Charles Garcia-Tobin, John Horley,
	Mike Leach, coresight, Linux Kernel Mailing List, devicetree

On 06/01/2018 08:46 PM, Mathieu Poirier wrote:
> On 1 June 2018 at 13:38, Mathieu Poirier <mathieu.poirier@linaro.org> wrote:
>> On Fri, Jun 01, 2018 at 02:16:01PM +0100, Suzuki K Poulose wrote:
>>> When parsing the remote endpoint of an output port, we do :
>>>       rport = of_graph_get_remote_port(ep);
>>>       rparent = of_graph_get_remote_port_parent(ep);
>>>
>>> and then parse the "remote_port" as if it was the remote endpoint,
>>> which is wrong. The code worked fine because we used endpoint number
>>> as the port number. Let us fix it and optimise a bit as:
>>>
>>>       remote_ep = of_graph_get_remote_endpoint(ep);
>>>       if (remote_ep)
>>>          remote_parent = of_graph_get_port_parent(remote_ep);
>>>
>>> and then, parse the remote_ep for the port/endpoint details.
>>>
>>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>>> ---
>>>   drivers/hwtracing/coresight/of_coresight.c | 19 ++++++++++---------
>>>   1 file changed, 10 insertions(+), 9 deletions(-)
>>>
>>> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
>>> index 7c37544..e0deab0 100644
>>> --- a/drivers/hwtracing/coresight/of_coresight.c
>>> +++ b/drivers/hwtracing/coresight/of_coresight.c
>>> @@ -128,7 +128,7 @@ of_get_coresight_platform_data(struct device *dev,
>>>        struct device *rdev;
>>>        struct device_node *ep = NULL;
>>>        struct device_node *rparent = NULL;
>>> -     struct device_node *rport = NULL;
>>> +     struct device_node *rep = NULL;
>>>
>>>        pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL);
>>>        if (!pdata)
>>> @@ -169,16 +169,17 @@ of_get_coresight_platform_data(struct device *dev,
>>>                        pdata->outports[i] = endpoint.port;
>>>
>>>                        /*
>>> -                      * Get a handle on the remote port and parent
>>> -                      * attached to it.
>>> +                      * Get a handle on the remote endpoint and the device
>>> +                      * it is attached to.
>>>                         */
>>> -                     rparent = of_graph_get_remote_port_parent(ep);
>>> -                     rport = of_graph_get_remote_port(ep);
>>> -
>>> -                     if (!rparent || !rport)
>>> +                     rep = of_graph_get_remote_endpoint(ep);
>>> +                     if (!rep)
>>> +                             continue;
>>> +                     rparent = of_graph_get_port_parent(rep);
>>> +                     if (!rparent)
>>>                                continue;
>>>
>>> -                     if (of_graph_parse_endpoint(rport, &rendpoint))
>>> +                     if (of_graph_parse_endpoint(rep, &rendpoint))
>>>                                continue;
>>
>> You are correct and I'm out to lunch.
>>
>>>
>>>                        rdev = of_coresight_get_endpoint_device(rparent);
>>> @@ -186,7 +187,7 @@ of_get_coresight_platform_data(struct device *dev,
>>>                                return ERR_PTR(-EPROBE_DEFER);
>>>
>>>                        pdata->child_names[i] = dev_name(rdev);
>>> -                     pdata->child_ports[i] = rendpoint.id;
>>> +                     pdata->child_ports[i] = rendpoint.port;
>>
>> You need to do a of_node_put() here for both rep and rparent.
> 
> Same thing for the "continue" and error condition above.


Mathieu,

Thanks for pointing that out. I see that we were missing them for the
existing code as well. I will clean all this up.

Cheers
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 2/8] coresight: Fix remote endpoint parsing
@ 2018-06-04 10:34         ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-04 10:34 UTC (permalink / raw)
  To: linux-arm-kernel

On 06/01/2018 08:46 PM, Mathieu Poirier wrote:
> On 1 June 2018 at 13:38, Mathieu Poirier <mathieu.poirier@linaro.org> wrote:
>> On Fri, Jun 01, 2018 at 02:16:01PM +0100, Suzuki K Poulose wrote:
>>> When parsing the remote endpoint of an output port, we do :
>>>       rport = of_graph_get_remote_port(ep);
>>>       rparent = of_graph_get_remote_port_parent(ep);
>>>
>>> and then parse the "remote_port" as if it was the remote endpoint,
>>> which is wrong. The code worked fine because we used endpoint number
>>> as the port number. Let us fix it and optimise a bit as:
>>>
>>>       remote_ep = of_graph_get_remote_endpoint(ep);
>>>       if (remote_ep)
>>>          remote_parent = of_graph_get_port_parent(remote_ep);
>>>
>>> and then, parse the remote_ep for the port/endpoint details.
>>>
>>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>>> ---
>>>   drivers/hwtracing/coresight/of_coresight.c | 19 ++++++++++---------
>>>   1 file changed, 10 insertions(+), 9 deletions(-)
>>>
>>> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
>>> index 7c37544..e0deab0 100644
>>> --- a/drivers/hwtracing/coresight/of_coresight.c
>>> +++ b/drivers/hwtracing/coresight/of_coresight.c
>>> @@ -128,7 +128,7 @@ of_get_coresight_platform_data(struct device *dev,
>>>        struct device *rdev;
>>>        struct device_node *ep = NULL;
>>>        struct device_node *rparent = NULL;
>>> -     struct device_node *rport = NULL;
>>> +     struct device_node *rep = NULL;
>>>
>>>        pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL);
>>>        if (!pdata)
>>> @@ -169,16 +169,17 @@ of_get_coresight_platform_data(struct device *dev,
>>>                        pdata->outports[i] = endpoint.port;
>>>
>>>                        /*
>>> -                      * Get a handle on the remote port and parent
>>> -                      * attached to it.
>>> +                      * Get a handle on the remote endpoint and the device
>>> +                      * it is attached to.
>>>                         */
>>> -                     rparent = of_graph_get_remote_port_parent(ep);
>>> -                     rport = of_graph_get_remote_port(ep);
>>> -
>>> -                     if (!rparent || !rport)
>>> +                     rep = of_graph_get_remote_endpoint(ep);
>>> +                     if (!rep)
>>> +                             continue;
>>> +                     rparent = of_graph_get_port_parent(rep);
>>> +                     if (!rparent)
>>>                                continue;
>>>
>>> -                     if (of_graph_parse_endpoint(rport, &rendpoint))
>>> +                     if (of_graph_parse_endpoint(rep, &rendpoint))
>>>                                continue;
>>
>> You are correct and I'm out to lunch.
>>
>>>
>>>                        rdev = of_coresight_get_endpoint_device(rparent);
>>> @@ -186,7 +187,7 @@ of_get_coresight_platform_data(struct device *dev,
>>>                                return ERR_PTR(-EPROBE_DEFER);
>>>
>>>                        pdata->child_names[i] = dev_name(rdev);
>>> -                     pdata->child_ports[i] = rendpoint.id;
>>> +                     pdata->child_ports[i] = rendpoint.port;
>>
>> You need to do a of_node_put() here for both rep and rparent.
> 
> Same thing for the "continue" and error condition above.


Mathieu,

Thanks for pointing that out. I see that we were missing them for the
existing code as well. I will clean all this up.

Cheers
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 7/8] dts: coresight: Define new bindings for direction of data flow
  2018-06-01 20:39     ` Mathieu Poirier
@ 2018-06-04 14:20       ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-04 14:20 UTC (permalink / raw)
  To: Mathieu Poirier
  Cc: linux-arm-kernel, sudeep.holla, robh, mark.rutland, frowand.list,
	matt.sealey, charles.garcia-tobin, john.horley, mike.leach,
	coresight, linux-kernel, devicetree

On 06/01/2018 09:39 PM, Mathieu Poirier wrote:
> On Fri, Jun 01, 2018 at 02:16:06PM +0100, Suzuki K Poulose wrote:
>> So far we have relied on an undocumented property "slave-mode",
>> to indicate if the given port is input or not. Since we are
>> redefining the coresight bindings, define new property for the
>> "direction" of data flow for a given connection endpoint in the
>> device.
>>
>> Each endpoint must define the following property.
>>
>>   - "direction" : 0 => Port is input
>> 		 1 => Port is output
>>
>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>> ---
>>   drivers/hwtracing/coresight/of_coresight.c | 20 ++++++++++++++++----
> 
> You haven't documented the binding in bindings/arm/coresight.txt the same way
> you did with "coresight,hwid".  I'm guessing you simply forgot to do a "git add"
> on the file when preparing the patchset.
> 
>>   1 file changed, 16 insertions(+), 4 deletions(-)
>>
>> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
>> index 99d7a9c..63c1668 100644
>> --- a/drivers/hwtracing/coresight/of_coresight.c
>> +++ b/drivers/hwtracing/coresight/of_coresight.c
>> @@ -52,7 +52,19 @@ of_coresight_get_endpoint_device(struct device_node *endpoint)
>>   			       endpoint, of_dev_node_match);
>>   }
>>   
>> -static void of_coresight_get_ports(const struct device_node *node,
>> +static bool of_coresight_ep_is_input(struct device *dev, struct device_node *ep_node)
> 
> I suggested of_coresight_endpoint_get_port_id() in my review of 6/8.  I'm good
> with either "ep" or "endpoint", as long as the names are consistent.

Yep, that's right. This is what I have for the documentation :

--- a/Documentation/devicetree/bindings/arm/coresight.txt
+++ b/Documentation/devicetree/bindings/arm/coresight.txt
@@ -103,9 +103,11 @@ with a specific direction of data flow, each 
connection must define the
  following properties to uniquely identify the connection details.

   * Direction of the data flow w.r.t the component :
-   Each input port must have the following property defined at the 
"endpoint"
+   Each hardware port must have the following property defined at the 
"endpoint"
     for the port.
-       "slave-mode"
+       "direction" - 32bit integer, whose values are defined as follows :
+               0 => the endpoint is an Input port
+               1 => the endpoint is an Output port.


and changes to the examples as well..


Cheers
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 7/8] dts: coresight: Define new bindings for direction of data flow
@ 2018-06-04 14:20       ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-04 14:20 UTC (permalink / raw)
  To: linux-arm-kernel

On 06/01/2018 09:39 PM, Mathieu Poirier wrote:
> On Fri, Jun 01, 2018 at 02:16:06PM +0100, Suzuki K Poulose wrote:
>> So far we have relied on an undocumented property "slave-mode",
>> to indicate if the given port is input or not. Since we are
>> redefining the coresight bindings, define new property for the
>> "direction" of data flow for a given connection endpoint in the
>> device.
>>
>> Each endpoint must define the following property.
>>
>>   - "direction" : 0 => Port is input
>> 		 1 => Port is output
>>
>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>> ---
>>   drivers/hwtracing/coresight/of_coresight.c | 20 ++++++++++++++++----
> 
> You haven't documented the binding in bindings/arm/coresight.txt the same way
> you did with "coresight,hwid".  I'm guessing you simply forgot to do a "git add"
> on the file when preparing the patchset.
> 
>>   1 file changed, 16 insertions(+), 4 deletions(-)
>>
>> diff --git a/drivers/hwtracing/coresight/of_coresight.c b/drivers/hwtracing/coresight/of_coresight.c
>> index 99d7a9c..63c1668 100644
>> --- a/drivers/hwtracing/coresight/of_coresight.c
>> +++ b/drivers/hwtracing/coresight/of_coresight.c
>> @@ -52,7 +52,19 @@ of_coresight_get_endpoint_device(struct device_node *endpoint)
>>   			       endpoint, of_dev_node_match);
>>   }
>>   
>> -static void of_coresight_get_ports(const struct device_node *node,
>> +static bool of_coresight_ep_is_input(struct device *dev, struct device_node *ep_node)
> 
> I suggested of_coresight_endpoint_get_port_id() in my review of 6/8.  I'm good
> with either "ep" or "endpoint", as long as the names are consistent.

Yep, that's right. This is what I have for the documentation :

--- a/Documentation/devicetree/bindings/arm/coresight.txt
+++ b/Documentation/devicetree/bindings/arm/coresight.txt
@@ -103,9 +103,11 @@ with a specific direction of data flow, each 
connection must define the
  following properties to uniquely identify the connection details.

   * Direction of the data flow w.r.t the component :
-   Each input port must have the following property defined at the 
"endpoint"
+   Each hardware port must have the following property defined at the 
"endpoint"
     for the port.
-       "slave-mode"
+       "direction" - 32bit integer, whose values are defined as follows :
+               0 => the endpoint is an Input port
+               1 => the endpoint is an Output port.


and changes to the examples as well..


Cheers
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-01 13:16   ` Suzuki K Poulose
@ 2018-06-12 20:48     ` Rob Herring
  -1 siblings, 0 replies; 77+ messages in thread
From: Rob Herring @ 2018-06-12 20:48 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: linux-arm-kernel, mathieu.poirier, sudeep.holla, mark.rutland,
	frowand.list, matt.sealey, charles.garcia-tobin, john.horley,
	mike.leach, coresight, linux-kernel, devicetree

On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
> The coresight drivers relied on default bindings for graph
> in DT, while reusing the "reg" field of the "ports" to indicate
> the actual hardware port number for the connections. However,
> with the rules getting stricter w.r.t to the address mismatch
> with the label, it is no longer possible to use the port address
> field for the hardware port number. Hence, we add an explicit
> property to denote the hardware port number, "coresight,hwid"
> which must be specified for each "endpoint".
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Cc: Sudeep Holla <sudeep.holla@arm.com>
> Cc: Rob Herring <robh@kernel.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>  drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>  2 files changed, 54 insertions(+), 18 deletions(-)
> 
> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
> index bd36e40..385581a 100644
> --- a/Documentation/devicetree/bindings/arm/coresight.txt
> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>  	"slave-mode"
>  
>   * Hardware Port number at the component:
> -     -  The hardware port number is assumed to be the address of the "port" component.
> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
> +   - Each "endpoint" must define the hardware port of the local end of the
> +     connection using the following property:
> +	"coresight,hwid" - 32bit integer, hardware port number at the local end.

"coresight" is not a vendor and properties are in the form 
[<vendor>,]<prop-name>.

> +
>  
>  
>  Example:
> @@ -120,6 +124,7 @@ Example:
>  			etb_in_port: endpoint@0 {

There shouldn't be a unit address here because there is no reg property.

>  				slave-mode;
>  				remote-endpoint = <&replicator_out_port0>;
> +				coresight,hwid = <0>;

It doesn't make sense for these to be in the endpoint. If you had 
multiple endpoints, then you would have to duplicate it. "ports" are 
a single data stream. "endpoints" are connections to that stream. So if 
you have a muxed (input) or fanout/1-to-many (output) connection, then 
you have multiple endpoints. 

The same applied to the slave-mode property, but that ship has sailed. 
No reason to continue that though.

>  			};
>  		};
>  	};
> @@ -134,6 +139,7 @@ Example:
>  			tpiu_in_port: endpoint@0 {
>  				slave-mode;
>  				remote-endpoint = <&replicator_out_port1>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -154,6 +160,7 @@ Example:
>  				reg = <0>;
>  				replicator_out_port0: endpoint {
>  					remote-endpoint = <&etb_in_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
> @@ -161,15 +168,17 @@ Example:
>  				reg = <1>;
>  				replicator_out_port1: endpoint {
>  					remote-endpoint = <&tpiu_in_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  
>  			/* replicator input port */
>  			port@2 {
> -				reg = <0>;
> +				reg = <1>;

This will still get flagged as an error. reg must be 2 here.

Rob

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-12 20:48     ` Rob Herring
  0 siblings, 0 replies; 77+ messages in thread
From: Rob Herring @ 2018-06-12 20:48 UTC (permalink / raw)
  To: linux-arm-kernel

On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
> The coresight drivers relied on default bindings for graph
> in DT, while reusing the "reg" field of the "ports" to indicate
> the actual hardware port number for the connections. However,
> with the rules getting stricter w.r.t to the address mismatch
> with the label, it is no longer possible to use the port address
> field for the hardware port number. Hence, we add an explicit
> property to denote the hardware port number, "coresight,hwid"
> which must be specified for each "endpoint".
> 
> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
> Cc: Sudeep Holla <sudeep.holla@arm.com>
> Cc: Rob Herring <robh@kernel.org>
> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> ---
>  .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>  drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>  2 files changed, 54 insertions(+), 18 deletions(-)
> 
> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
> index bd36e40..385581a 100644
> --- a/Documentation/devicetree/bindings/arm/coresight.txt
> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>  	"slave-mode"
>  
>   * Hardware Port number at the component:
> -     -  The hardware port number is assumed to be the address of the "port" component.
> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
> +   - Each "endpoint" must define the hardware port of the local end of the
> +     connection using the following property:
> +	"coresight,hwid" - 32bit integer, hardware port number at the local end.

"coresight" is not a vendor and properties are in the form 
[<vendor>,]<prop-name>.

> +
>  
>  
>  Example:
> @@ -120,6 +124,7 @@ Example:
>  			etb_in_port: endpoint at 0 {

There shouldn't be a unit address here because there is no reg property.

>  				slave-mode;
>  				remote-endpoint = <&replicator_out_port0>;
> +				coresight,hwid = <0>;

It doesn't make sense for these to be in the endpoint. If you had 
multiple endpoints, then you would have to duplicate it. "ports" are 
a single data stream. "endpoints" are connections to that stream. So if 
you have a muxed (input) or fanout/1-to-many (output) connection, then 
you have multiple endpoints. 

The same applied to the slave-mode property, but that ship has sailed. 
No reason to continue that though.

>  			};
>  		};
>  	};
> @@ -134,6 +139,7 @@ Example:
>  			tpiu_in_port: endpoint at 0 {
>  				slave-mode;
>  				remote-endpoint = <&replicator_out_port1>;
> +				coresight,hwid = <0>;
>  			};
>  		};
>  	};
> @@ -154,6 +160,7 @@ Example:
>  				reg = <0>;
>  				replicator_out_port0: endpoint {
>  					remote-endpoint = <&etb_in_port>;
> +					coresight,hwid = <0>;
>  				};
>  			};
>  
> @@ -161,15 +168,17 @@ Example:
>  				reg = <1>;
>  				replicator_out_port1: endpoint {
>  					remote-endpoint = <&tpiu_in_port>;
> +					coresight,hwid = <1>;
>  				};
>  			};
>  
>  			/* replicator input port */
>  			port at 2 {
> -				reg = <0>;
> +				reg = <1>;

This will still get flagged as an error. reg must be 2 here.

Rob

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-12 20:48     ` Rob Herring
@ 2018-06-13  9:45       ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-13  9:45 UTC (permalink / raw)
  To: Rob Herring
  Cc: linux-arm-kernel, mathieu.poirier, sudeep.holla, mark.rutland,
	frowand.list, matt.sealey, charles.garcia-tobin, john.horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Rob,

On 12/06/18 21:48, Rob Herring wrote:
> On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
>> The coresight drivers relied on default bindings for graph
>> in DT, while reusing the "reg" field of the "ports" to indicate
>> the actual hardware port number for the connections. However,
>> with the rules getting stricter w.r.t to the address mismatch
>> with the label, it is no longer possible to use the port address
>> field for the hardware port number. Hence, we add an explicit
>> property to denote the hardware port number, "coresight,hwid"
>> which must be specified for each "endpoint".
>>
>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>> Cc: Sudeep Holla <sudeep.holla@arm.com>
>> Cc: Rob Herring <robh@kernel.org>
>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>> ---
>>   .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>>   drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>>   2 files changed, 54 insertions(+), 18 deletions(-)
>>
>> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
>> index bd36e40..385581a 100644
>> --- a/Documentation/devicetree/bindings/arm/coresight.txt
>> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
>> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>>   	"slave-mode"
>>   
>>    * Hardware Port number at the component:
>> -     -  The hardware port number is assumed to be the address of the "port" component.
>> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
>> +   - Each "endpoint" must define the hardware port of the local end of the
>> +     connection using the following property:
>> +	"coresight,hwid" - 32bit integer, hardware port number at the local end.
> 
> "coresight" is not a vendor and properties are in the form
> [<vendor>,]<prop-name>.

OK. The issue here is that a coresight component could be an Arm IP or
a custom partner IP. So, the vendor could be either arm or the partner id.
However, this property is kind of a generic one for the Coresight family,
which is why we opted for "coresight". What is the guideline for such
cases ?

Or in other words I see the following possible options :

1) coresight,hwid	- coresight generic
2) arm,coresight-hwid	- arm vendor, however the device could be from any vendor.
3) hwid			- Generic
4) none of the above, something completely different.

What do you recommend from the above ?

>> +
>>   
>>   
>>   Example:
>> @@ -120,6 +124,7 @@ Example:
>>   			etb_in_port: endpoint@0 {
> 
> There shouldn't be a unit address here because there is no reg property.
> 
>>   				slave-mode;
>>   				remote-endpoint = <&replicator_out_port0>;
>> +				coresight,hwid = <0>;
> 
> It doesn't make sense for these to be in the endpoint. If you had
> multiple endpoints, then you would have to duplicate it. "ports" are
> a single data stream. "endpoints" are connections to that stream. So if
> you have a muxed (input) or fanout/1-to-many (output) connection, then
> you have multiple endpoints.

We do have many-to-1 input (e.g, funnels) and 1-to-many outputs
(e.g replicators). However, we have (so far) used only one endpoint per
port.

Also we could potentially have multiple data streams flowing through
the ports, which gets filtered to different ports in 1-to-many components
(read programmable-replicator).

So the point is we have a shared path which carries different data
streams with mux/demux components. I am open for suggestions based on
the above facts.

> 
> The same applied to the slave-mode property, but that ship has sailed.
> No reason to continue that though.
> 
>>   			};
>>   		};
>>   	};
>> @@ -134,6 +139,7 @@ Example:
>>   			tpiu_in_port: endpoint@0 {
>>   				slave-mode;
>>   				remote-endpoint = <&replicator_out_port1>;
>> +				coresight,hwid = <0>;
>>   			};
>>   		};
>>   	};
>> @@ -154,6 +160,7 @@ Example:
>>   				reg = <0>;
>>   				replicator_out_port0: endpoint {
>>   					remote-endpoint = <&etb_in_port>;
>> +					coresight,hwid = <0>;
>>   				};
>>   			};
>>   
>> @@ -161,15 +168,17 @@ Example:
>>   				reg = <1>;
>>   				replicator_out_port1: endpoint {
>>   					remote-endpoint = <&tpiu_in_port>;
>> +					coresight,hwid = <1>;
>>   				};
>>   			};
>>   
>>   			/* replicator input port */
>>   			port@2 {
>> -				reg = <0>;
>> +				reg = <1>;
> 
> This will still get flagged as an error. reg must be 2 here.

Sorry, thats a mistake. I will fix it.

Cheers
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13  9:45       ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-13  9:45 UTC (permalink / raw)
  To: linux-arm-kernel

Hi Rob,

On 12/06/18 21:48, Rob Herring wrote:
> On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
>> The coresight drivers relied on default bindings for graph
>> in DT, while reusing the "reg" field of the "ports" to indicate
>> the actual hardware port number for the connections. However,
>> with the rules getting stricter w.r.t to the address mismatch
>> with the label, it is no longer possible to use the port address
>> field for the hardware port number. Hence, we add an explicit
>> property to denote the hardware port number, "coresight,hwid"
>> which must be specified for each "endpoint".
>>
>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>> Cc: Sudeep Holla <sudeep.holla@arm.com>
>> Cc: Rob Herring <robh@kernel.org>
>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>> ---
>>   .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>>   drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>>   2 files changed, 54 insertions(+), 18 deletions(-)
>>
>> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
>> index bd36e40..385581a 100644
>> --- a/Documentation/devicetree/bindings/arm/coresight.txt
>> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
>> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>>   	"slave-mode"
>>   
>>    * Hardware Port number at the component:
>> -     -  The hardware port number is assumed to be the address of the "port" component.
>> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
>> +   - Each "endpoint" must define the hardware port of the local end of the
>> +     connection using the following property:
>> +	"coresight,hwid" - 32bit integer, hardware port number at the local end.
> 
> "coresight" is not a vendor and properties are in the form
> [<vendor>,]<prop-name>.

OK. The issue here is that a coresight component could be an Arm IP or
a custom partner IP. So, the vendor could be either arm or the partner id.
However, this property is kind of a generic one for the Coresight family,
which is why we opted for "coresight". What is the guideline for such
cases ?

Or in other words I see the following possible options :

1) coresight,hwid	- coresight generic
2) arm,coresight-hwid	- arm vendor, however the device could be from any vendor.
3) hwid			- Generic
4) none of the above, something completely different.

What do you recommend from the above ?

>> +
>>   
>>   
>>   Example:
>> @@ -120,6 +124,7 @@ Example:
>>   			etb_in_port: endpoint at 0 {
> 
> There shouldn't be a unit address here because there is no reg property.
> 
>>   				slave-mode;
>>   				remote-endpoint = <&replicator_out_port0>;
>> +				coresight,hwid = <0>;
> 
> It doesn't make sense for these to be in the endpoint. If you had
> multiple endpoints, then you would have to duplicate it. "ports" are
> a single data stream. "endpoints" are connections to that stream. So if
> you have a muxed (input) or fanout/1-to-many (output) connection, then
> you have multiple endpoints.

We do have many-to-1 input (e.g, funnels) and 1-to-many outputs
(e.g replicators). However, we have (so far) used only one endpoint per
port.

Also we could potentially have multiple data streams flowing through
the ports, which gets filtered to different ports in 1-to-many components
(read programmable-replicator).

So the point is we have a shared path which carries different data
streams with mux/demux components. I am open for suggestions based on
the above facts.

> 
> The same applied to the slave-mode property, but that ship has sailed.
> No reason to continue that though.
> 
>>   			};
>>   		};
>>   	};
>> @@ -134,6 +139,7 @@ Example:
>>   			tpiu_in_port: endpoint at 0 {
>>   				slave-mode;
>>   				remote-endpoint = <&replicator_out_port1>;
>> +				coresight,hwid = <0>;
>>   			};
>>   		};
>>   	};
>> @@ -154,6 +160,7 @@ Example:
>>   				reg = <0>;
>>   				replicator_out_port0: endpoint {
>>   					remote-endpoint = <&etb_in_port>;
>> +					coresight,hwid = <0>;
>>   				};
>>   			};
>>   
>> @@ -161,15 +168,17 @@ Example:
>>   				reg = <1>;
>>   				replicator_out_port1: endpoint {
>>   					remote-endpoint = <&tpiu_in_port>;
>> +					coresight,hwid = <1>;
>>   				};
>>   			};
>>   
>>   			/* replicator input port */
>>   			port at 2 {
>> -				reg = <0>;
>> +				reg = <1>;
> 
> This will still get flagged as an error. reg must be 2 here.

Sorry, thats a mistake. I will fix it.

Cheers
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-13  9:45       ` Suzuki K Poulose
  (?)
@ 2018-06-13 12:49         ` Matt Sealey
  -1 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 12:49 UTC (permalink / raw)
  To: Suzuki Poulose
  Cc: Rob Herring, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Suzuki,

Why not use “unit”?

I believe we had this discussion years ago about numbering serial ports and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address? Some SoC’s don’t address sequentially *or* in a forward direction) - I believe it’s not exactly codified in ePAPR, not am I sure where it may be otherwise, but it exists.

I agree with Rob on the slave-mode nonsense, this is an SPI controller concept weirdly stuffed into a directed graph which implicitly tells you the data direction - it’s a rooted tree (just like DT!).

For the case of a funnel each device supplying trace should end up into an input node - numbered with a unit - and all those nodes should point to the output node as endpoints. Describing the hardware as a black box is probably less of a good idea than showing that it’s a funnel, or replicator by showing the internal paths. You wouldn’t need to “number” ports with a unit except where the HW needs to differentiate between them, and you don’t need reg or a node address to do it.

If you really need to parse full graphs in both directions (find root, find leaf) then could we simply introduce properties which list the phandles of all uplink sources, as linked lists point to the list head?

This gives a way to validate that the graph starts and ends the way we expect, and also allows every port to be associated with being a required path between any two devices without parsing the *whole* graph (although you still need to do that to find the route to sinks).

Ta,
Matt

Sent from my iPhone

> On Jun 13, 2018, at 04:45, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
>
> Hi Rob,
>
>> On 12/06/18 21:48, Rob Herring wrote:
>>> On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
>>> The coresight drivers relied on default bindings for graph
>>> in DT, while reusing the "reg" field of the "ports" to indicate
>>> the actual hardware port number for the connections. However,
>>> with the rules getting stricter w.r.t to the address mismatch
>>> with the label, it is no longer possible to use the port address
>>> field for the hardware port number. Hence, we add an explicit
>>> property to denote the hardware port number, "coresight,hwid"
>>> which must be specified for each "endpoint".
>>>
>>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>>> Cc: Sudeep Holla <sudeep.holla@arm.com>
>>> Cc: Rob Herring <robh@kernel.org>
>>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>>> ---
>>>  .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>>>  drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>>>  2 files changed, 54 insertions(+), 18 deletions(-)
>>>
>>> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
>>> index bd36e40..385581a 100644
>>> --- a/Documentation/devicetree/bindings/arm/coresight.txt
>>> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
>>> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>>>      "slave-mode"
>>>     * Hardware Port number at the component:
>>> -     -  The hardware port number is assumed to be the address of the "port" component.
>>> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
>>> +   - Each "endpoint" must define the hardware port of the local end of the
>>> +     connection using the following property:
>>> +    "coresight,hwid" - 32bit integer, hardware port number at the local end.
>> "coresight" is not a vendor and properties are in the form
>> [<vendor>,]<prop-name>.
>
> OK. The issue here is that a coresight component could be an Arm IP or
> a custom partner IP. So, the vendor could be either arm or the partner id.
> However, this property is kind of a generic one for the Coresight family,
> which is why we opted for "coresight". What is the guideline for such
> cases ?
>
> Or in other words I see the following possible options :
>
> 1) coresight,hwid    - coresight generic
> 2) arm,coresight-hwid    - arm vendor, however the device could be from any vendor.
> 3) hwid            - Generic
> 4) none of the above, something completely different.
>
> What do you recommend from the above ?
>
>>> +
>>>      Example:
>>> @@ -120,6 +124,7 @@ Example:
>>>              etb_in_port: endpoint@0 {
>> There shouldn't be a unit address here because there is no reg property.
>>>                  slave-mode;
>>>                  remote-endpoint = <&replicator_out_port0>;
>>> +                coresight,hwid = <0>;
>> It doesn't make sense for these to be in the endpoint. If you had
>> multiple endpoints, then you would have to duplicate it. "ports" are
>> a single data stream. "endpoints" are connections to that stream. So if
>> you have a muxed (input) or fanout/1-to-many (output) connection, then
>> you have multiple endpoints.
>
> We do have many-to-1 input (e.g, funnels) and 1-to-many outputs
> (e.g replicators). However, we have (so far) used only one endpoint per
> port.
>
> Also we could potentially have multiple data streams flowing through
> the ports, which gets filtered to different ports in 1-to-many components
> (read programmable-replicator).
>
> So the point is we have a shared path which carries different data
> streams with mux/demux components. I am open for suggestions based on
> the above facts.
>
>> The same applied to the slave-mode property, but that ship has sailed.
>> No reason to continue that though.
>>>              };
>>>          };
>>>      };
>>> @@ -134,6 +139,7 @@ Example:
>>>              tpiu_in_port: endpoint@0 {
>>>                  slave-mode;
>>>                  remote-endpoint = <&replicator_out_port1>;
>>> +                coresight,hwid = <0>;
>>>              };
>>>          };
>>>      };
>>> @@ -154,6 +160,7 @@ Example:
>>>                  reg = <0>;
>>>                  replicator_out_port0: endpoint {
>>>                      remote-endpoint = <&etb_in_port>;
>>> +                    coresight,hwid = <0>;
>>>                  };
>>>              };
>>>  @@ -161,15 +168,17 @@ Example:
>>>                  reg = <1>;
>>>                  replicator_out_port1: endpoint {
>>>                      remote-endpoint = <&tpiu_in_port>;
>>> +                    coresight,hwid = <1>;
>>>                  };
>>>              };
>>>                /* replicator input port */
>>>              port@2 {
>>> -                reg = <0>;
>>> +                reg = <1>;
>> This will still get flagged as an error. reg must be 2 here.
>
> Sorry, thats a mistake. I will fix it.
>
> Cheers
> Suzuki
IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 12:49         ` Matt Sealey
  0 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 12:49 UTC (permalink / raw)
  To: Suzuki Poulose
  Cc: Rob Herring, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Suzuki,

Why not use “unit”?

I believe we had this discussion years ago about numbering serial ports and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address? Some SoC’s don’t address sequentially *or* in a forward direction) - I believe it’s not exactly codified in ePAPR, not am I sure where it may be otherwise, but it exists.

I agree with Rob on the slave-mode nonsense, this is an SPI controller concept weirdly stuffed into a directed graph which implicitly tells you the data direction - it’s a rooted tree (just like DT!).

For the case of a funnel each device supplying trace should end up into an input node - numbered with a unit - and all those nodes should point to the output node as endpoints. Describing the hardware as a black box is probably less of a good idea than showing that it’s a funnel, or replicator by showing the internal paths. You wouldn’t need to “number” ports with a unit except where the HW needs to differentiate between them, and you don’t need reg or a node address to do it.

If you really need to parse full graphs in both directions (find root, find leaf) then could we simply introduce properties which list the phandles of all uplink sources, as linked lists point to the list head?

This gives a way to validate that the graph starts and ends the way we expect, and also allows every port to be associated with being a required path between any two devices without parsing the *whole* graph (although you still need to do that to find the route to sinks).

Ta,
Matt

Sent from my iPhone

> On Jun 13, 2018, at 04:45, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
>
> Hi Rob,
>
>> On 12/06/18 21:48, Rob Herring wrote:
>>> On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
>>> The coresight drivers relied on default bindings for graph
>>> in DT, while reusing the "reg" field of the "ports" to indicate
>>> the actual hardware port number for the connections. However,
>>> with the rules getting stricter w.r.t to the address mismatch
>>> with the label, it is no longer possible to use the port address
>>> field for the hardware port number. Hence, we add an explicit
>>> property to denote the hardware port number, "coresight,hwid"
>>> which must be specified for each "endpoint".
>>>
>>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>>> Cc: Sudeep Holla <sudeep.holla@arm.com>
>>> Cc: Rob Herring <robh@kernel.org>
>>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>>> ---
>>>  .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>>>  drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>>>  2 files changed, 54 insertions(+), 18 deletions(-)
>>>
>>> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
>>> index bd36e40..385581a 100644
>>> --- a/Documentation/devicetree/bindings/arm/coresight.txt
>>> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
>>> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>>>      "slave-mode"
>>>     * Hardware Port number at the component:
>>> -     -  The hardware port number is assumed to be the address of the "port" component.
>>> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
>>> +   - Each "endpoint" must define the hardware port of the local end of the
>>> +     connection using the following property:
>>> +    "coresight,hwid" - 32bit integer, hardware port number at the local end.
>> "coresight" is not a vendor and properties are in the form
>> [<vendor>,]<prop-name>.
>
> OK. The issue here is that a coresight component could be an Arm IP or
> a custom partner IP. So, the vendor could be either arm or the partner id.
> However, this property is kind of a generic one for the Coresight family,
> which is why we opted for "coresight". What is the guideline for such
> cases ?
>
> Or in other words I see the following possible options :
>
> 1) coresight,hwid    - coresight generic
> 2) arm,coresight-hwid    - arm vendor, however the device could be from any vendor.
> 3) hwid            - Generic
> 4) none of the above, something completely different.
>
> What do you recommend from the above ?
>
>>> +
>>>      Example:
>>> @@ -120,6 +124,7 @@ Example:
>>>              etb_in_port: endpoint@0 {
>> There shouldn't be a unit address here because there is no reg property.
>>>                  slave-mode;
>>>                  remote-endpoint = <&replicator_out_port0>;
>>> +                coresight,hwid = <0>;
>> It doesn't make sense for these to be in the endpoint. If you had
>> multiple endpoints, then you would have to duplicate it. "ports" are
>> a single data stream. "endpoints" are connections to that stream. So if
>> you have a muxed (input) or fanout/1-to-many (output) connection, then
>> you have multiple endpoints.
>
> We do have many-to-1 input (e.g, funnels) and 1-to-many outputs
> (e.g replicators). However, we have (so far) used only one endpoint per
> port.
>
> Also we could potentially have multiple data streams flowing through
> the ports, which gets filtered to different ports in 1-to-many components
> (read programmable-replicator).
>
> So the point is we have a shared path which carries different data
> streams with mux/demux components. I am open for suggestions based on
> the above facts.
>
>> The same applied to the slave-mode property, but that ship has sailed.
>> No reason to continue that though.
>>>              };
>>>          };
>>>      };
>>> @@ -134,6 +139,7 @@ Example:
>>>              tpiu_in_port: endpoint@0 {
>>>                  slave-mode;
>>>                  remote-endpoint = <&replicator_out_port1>;
>>> +                coresight,hwid = <0>;
>>>              };
>>>          };
>>>      };
>>> @@ -154,6 +160,7 @@ Example:
>>>                  reg = <0>;
>>>                  replicator_out_port0: endpoint {
>>>                      remote-endpoint = <&etb_in_port>;
>>> +                    coresight,hwid = <0>;
>>>                  };
>>>              };
>>>  @@ -161,15 +168,17 @@ Example:
>>>                  reg = <1>;
>>>                  replicator_out_port1: endpoint {
>>>                      remote-endpoint = <&tpiu_in_port>;
>>> +                    coresight,hwid = <1>;
>>>                  };
>>>              };
>>>                /* replicator input port */
>>>              port@2 {
>>> -                reg = <0>;
>>> +                reg = <1>;
>> This will still get flagged as an error. reg must be 2 here.
>
> Sorry, thats a mistake. I will fix it.
>
> Cheers
> Suzuki
IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 12:49         ` Matt Sealey
  0 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 12:49 UTC (permalink / raw)
  To: linux-arm-kernel

Suzuki,

Why not use ?unit??

I believe we had this discussion years ago about numbering serial ports and sdhci (i.e. how do you know it?s UART0 or UART1 from just the address? Some SoC?s don?t address sequentially *or* in a forward direction) - I believe it?s not exactly codified in ePAPR, not am I sure where it may be otherwise, but it exists.

I agree with Rob on the slave-mode nonsense, this is an SPI controller concept weirdly stuffed into a directed graph which implicitly tells you the data direction - it?s a rooted tree (just like DT!).

For the case of a funnel each device supplying trace should end up into an input node - numbered with a unit - and all those nodes should point to the output node as endpoints. Describing the hardware as a black box is probably less of a good idea than showing that it?s a funnel, or replicator by showing the internal paths. You wouldn?t need to ?number? ports with a unit except where the HW needs to differentiate between them, and you don?t need reg or a node address to do it.

If you really need to parse full graphs in both directions (find root, find leaf) then could we simply introduce properties which list the phandles of all uplink sources, as linked lists point to the list head?

This gives a way to validate that the graph starts and ends the way we expect, and also allows every port to be associated with being a required path between any two devices without parsing the *whole* graph (although you still need to do that to find the route to sinks).

Ta,
Matt

Sent from my iPhone

> On Jun 13, 2018, at 04:45, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
>
> Hi Rob,
>
>> On 12/06/18 21:48, Rob Herring wrote:
>>> On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
>>> The coresight drivers relied on default bindings for graph
>>> in DT, while reusing the "reg" field of the "ports" to indicate
>>> the actual hardware port number for the connections. However,
>>> with the rules getting stricter w.r.t to the address mismatch
>>> with the label, it is no longer possible to use the port address
>>> field for the hardware port number. Hence, we add an explicit
>>> property to denote the hardware port number, "coresight,hwid"
>>> which must be specified for each "endpoint".
>>>
>>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>>> Cc: Sudeep Holla <sudeep.holla@arm.com>
>>> Cc: Rob Herring <robh@kernel.org>
>>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>>> ---
>>>  .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>>>  drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>>>  2 files changed, 54 insertions(+), 18 deletions(-)
>>>
>>> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
>>> index bd36e40..385581a 100644
>>> --- a/Documentation/devicetree/bindings/arm/coresight.txt
>>> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
>>> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>>>      "slave-mode"
>>>     * Hardware Port number at the component:
>>> -     -  The hardware port number is assumed to be the address of the "port" component.
>>> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
>>> +   - Each "endpoint" must define the hardware port of the local end of the
>>> +     connection using the following property:
>>> +    "coresight,hwid" - 32bit integer, hardware port number at the local end.
>> "coresight" is not a vendor and properties are in the form
>> [<vendor>,]<prop-name>.
>
> OK. The issue here is that a coresight component could be an Arm IP or
> a custom partner IP. So, the vendor could be either arm or the partner id.
> However, this property is kind of a generic one for the Coresight family,
> which is why we opted for "coresight". What is the guideline for such
> cases ?
>
> Or in other words I see the following possible options :
>
> 1) coresight,hwid    - coresight generic
> 2) arm,coresight-hwid    - arm vendor, however the device could be from any vendor.
> 3) hwid            - Generic
> 4) none of the above, something completely different.
>
> What do you recommend from the above ?
>
>>> +
>>>      Example:
>>> @@ -120,6 +124,7 @@ Example:
>>>              etb_in_port: endpoint at 0 {
>> There shouldn't be a unit address here because there is no reg property.
>>>                  slave-mode;
>>>                  remote-endpoint = <&replicator_out_port0>;
>>> +                coresight,hwid = <0>;
>> It doesn't make sense for these to be in the endpoint. If you had
>> multiple endpoints, then you would have to duplicate it. "ports" are
>> a single data stream. "endpoints" are connections to that stream. So if
>> you have a muxed (input) or fanout/1-to-many (output) connection, then
>> you have multiple endpoints.
>
> We do have many-to-1 input (e.g, funnels) and 1-to-many outputs
> (e.g replicators). However, we have (so far) used only one endpoint per
> port.
>
> Also we could potentially have multiple data streams flowing through
> the ports, which gets filtered to different ports in 1-to-many components
> (read programmable-replicator).
>
> So the point is we have a shared path which carries different data
> streams with mux/demux components. I am open for suggestions based on
> the above facts.
>
>> The same applied to the slave-mode property, but that ship has sailed.
>> No reason to continue that though.
>>>              };
>>>          };
>>>      };
>>> @@ -134,6 +139,7 @@ Example:
>>>              tpiu_in_port: endpoint at 0 {
>>>                  slave-mode;
>>>                  remote-endpoint = <&replicator_out_port1>;
>>> +                coresight,hwid = <0>;
>>>              };
>>>          };
>>>      };
>>> @@ -154,6 +160,7 @@ Example:
>>>                  reg = <0>;
>>>                  replicator_out_port0: endpoint {
>>>                      remote-endpoint = <&etb_in_port>;
>>> +                    coresight,hwid = <0>;
>>>                  };
>>>              };
>>>  @@ -161,15 +168,17 @@ Example:
>>>                  reg = <1>;
>>>                  replicator_out_port1: endpoint {
>>>                      remote-endpoint = <&tpiu_in_port>;
>>> +                    coresight,hwid = <1>;
>>>                  };
>>>              };
>>>                /* replicator input port */
>>>              port at 2 {
>>> -                reg = <0>;
>>> +                reg = <1>;
>> This will still get flagged as an error. reg must be 2 here.
>
> Sorry, thats a mistake. I will fix it.
>
> Cheers
> Suzuki
IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-13 12:49         ` Matt Sealey
  (?)
@ 2018-06-13 13:35           ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-13 13:35 UTC (permalink / raw)
  To: Matt Sealey
  Cc: Rob Herring, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Matt,

Thanks for your comments, responses inline.

On 13/06/18 13:49, Matt Sealey wrote:
> Suzuki,
> 
> Why not use “unit”?
> 
> I believe we had this discussion years ago about numbering serial ports and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address? Some SoC’s don’t address sequentially *or* in a forward direction) - I believe it’s not exactly codified in ePAPR, not am I sure where it may be otherwise, but it exists.

We have different situation here. We need to know *the port number* as understood by the
hardware, so that we can enable *the specific* port for a given path.

> 
> I agree with Rob on the slave-mode nonsense, this is an SPI controller concept weirdly stuffed into a directed graph which implicitly tells you the data direction - it’s a rooted tree (just like DT!).

Btw, the "slave-mode" is not a standard DT graph binding. It is not part of the
generic DT graph binding. In fact the generic bindings stay away from the direction
aspect and explicitly mentions the same.

> 
> For the case of a funnel each device supplying trace should end up into an input node - numbered with a unit - and all those nodes should point to the output node as endpoints. Describing the hardware as a black box is probably less of a good idea than showing that it’s a funnel, or replicator by showing the internal paths. You wouldn’t need to “number” ports with a unit except where the HW needs to differentiate between them, and you don’t need reg or a node address to do it.
> 

As I mentioned above, we need the hardware numbers to enable the "specific" port.

E.g, :

static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
{
         u32 functl;

         CS_UNLOCK(drvdata->base);

         functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
         functl &= ~FUNNEL_HOLDTIME_MASK;
         functl |= FUNNEL_HOLDTIME;
         functl |= (1 << port);
         writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
         writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);

         CS_LOCK(drvdata->base);
}


> If you really need to parse full graphs in both directions (find root, find leaf) then could we simply introduce properties which list the phandles of all uplink sources, as linked lists point to the list head?

No we don't need to parse it in both ways, up and down. Btw, the trace paths
are not statically created. They are done at runtime, as configured by the
user. So all we need to do is have a list of the ports and the devices it
is connected to (of course with direction information). I would stay
away from duplicating the platform code when something already does
a good job.

> 
> This gives a way to validate that the graph starts and ends the way we expect, and also allows every port to be associated with being a required path between any two devices without parsing the *whole* graph (although you still need to do that to find the route to sinks).

Coming back to your suggestion of "unit", what does it imply ?
Its too generic a term for something as concrete as a port number.

Cheers
Suzuki

> 
> Ta,
> Matt
> 
> Sent from my iPhone
> 
>> On Jun 13, 2018, at 04:45, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
>>
>> Hi Rob,
>>
>>> On 12/06/18 21:48, Rob Herring wrote:
>>>> On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
>>>> The coresight drivers relied on default bindings for graph
>>>> in DT, while reusing the "reg" field of the "ports" to indicate
>>>> the actual hardware port number for the connections. However,
>>>> with the rules getting stricter w.r.t to the address mismatch
>>>> with the label, it is no longer possible to use the port address
>>>> field for the hardware port number. Hence, we add an explicit
>>>> property to denote the hardware port number, "coresight,hwid"
>>>> which must be specified for each "endpoint".
>>>>
>>>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>> Cc: Sudeep Holla <sudeep.holla@arm.com>
>>>> Cc: Rob Herring <robh@kernel.org>
>>>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>>>> ---
>>>>   .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>>>>   drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>>>>   2 files changed, 54 insertions(+), 18 deletions(-)
>>>>
>>>> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
>>>> index bd36e40..385581a 100644
>>>> --- a/Documentation/devicetree/bindings/arm/coresight.txt
>>>> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
>>>> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>>>>       "slave-mode"
>>>>      * Hardware Port number at the component:
>>>> -     -  The hardware port number is assumed to be the address of the "port" component.
>>>> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
>>>> +   - Each "endpoint" must define the hardware port of the local end of the
>>>> +     connection using the following property:
>>>> +    "coresight,hwid" - 32bit integer, hardware port number at the local end.
>>> "coresight" is not a vendor and properties are in the form
>>> [<vendor>,]<prop-name>.
>>
>> OK. The issue here is that a coresight component could be an Arm IP or
>> a custom partner IP. So, the vendor could be either arm or the partner id.
>> However, this property is kind of a generic one for the Coresight family,
>> which is why we opted for "coresight". What is the guideline for such
>> cases ?
>>
>> Or in other words I see the following possible options :
>>
>> 1) coresight,hwid    - coresight generic
>> 2) arm,coresight-hwid    - arm vendor, however the device could be from any vendor.
>> 3) hwid            - Generic
>> 4) none of the above, something completely different.
>>
>> What do you recommend from the above ?
>>
>>>> +
>>>>       Example:
>>>> @@ -120,6 +124,7 @@ Example:
>>>>               etb_in_port: endpoint@0 {
>>> There shouldn't be a unit address here because there is no reg property.
>>>>                   slave-mode;
>>>>                   remote-endpoint = <&replicator_out_port0>;
>>>> +                coresight,hwid = <0>;
>>> It doesn't make sense for these to be in the endpoint. If you had
>>> multiple endpoints, then you would have to duplicate it. "ports" are
>>> a single data stream. "endpoints" are connections to that stream. So if
>>> you have a muxed (input) or fanout/1-to-many (output) connection, then
>>> you have multiple endpoints.
>>
>> We do have many-to-1 input (e.g, funnels) and 1-to-many outputs
>> (e.g replicators). However, we have (so far) used only one endpoint per
>> port.
>>
>> Also we could potentially have multiple data streams flowing through
>> the ports, which gets filtered to different ports in 1-to-many components
>> (read programmable-replicator).
>>
>> So the point is we have a shared path which carries different data
>> streams with mux/demux components. I am open for suggestions based on
>> the above facts.
>>
>>> The same applied to the slave-mode property, but that ship has sailed.
>>> No reason to continue that though.
>>>>               };
>>>>           };
>>>>       };
>>>> @@ -134,6 +139,7 @@ Example:
>>>>               tpiu_in_port: endpoint@0 {
>>>>                   slave-mode;
>>>>                   remote-endpoint = <&replicator_out_port1>;
>>>> +                coresight,hwid = <0>;
>>>>               };
>>>>           };
>>>>       };
>>>> @@ -154,6 +160,7 @@ Example:
>>>>                   reg = <0>;
>>>>                   replicator_out_port0: endpoint {
>>>>                       remote-endpoint = <&etb_in_port>;
>>>> +                    coresight,hwid = <0>;
>>>>                   };
>>>>               };
>>>>   @@ -161,15 +168,17 @@ Example:
>>>>                   reg = <1>;
>>>>                   replicator_out_port1: endpoint {
>>>>                       remote-endpoint = <&tpiu_in_port>;
>>>> +                    coresight,hwid = <1>;
>>>>                   };
>>>>               };
>>>>                 /* replicator input port */
>>>>               port@2 {
>>>> -                reg = <0>;
>>>> +                reg = <1>;
>>> This will still get flagged as an error. reg must be 2 here.
>>
>> Sorry, thats a mistake. I will fix it.
>>
>> Cheers
>> Suzuki


^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 13:35           ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-13 13:35 UTC (permalink / raw)
  To: Matt Sealey
  Cc: Rob Herring, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Matt,

Thanks for your comments, responses inline.

On 13/06/18 13:49, Matt Sealey wrote:
> Suzuki,
> 
> Why not use “unit”?
> 
> I believe we had this discussion years ago about numbering serial ports and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address? Some SoC’s don’t address sequentially *or* in a forward direction) - I believe it’s not exactly codified in ePAPR, not am I sure where it may be otherwise, but it exists.

We have different situation here. We need to know *the port number* as understood by the
hardware, so that we can enable *the specific* port for a given path.

> 
> I agree with Rob on the slave-mode nonsense, this is an SPI controller concept weirdly stuffed into a directed graph which implicitly tells you the data direction - it’s a rooted tree (just like DT!).

Btw, the "slave-mode" is not a standard DT graph binding. It is not part of the
generic DT graph binding. In fact the generic bindings stay away from the direction
aspect and explicitly mentions the same.

> 
> For the case of a funnel each device supplying trace should end up into an input node - numbered with a unit - and all those nodes should point to the output node as endpoints. Describing the hardware as a black box is probably less of a good idea than showing that it’s a funnel, or replicator by showing the internal paths. You wouldn’t need to “number” ports with a unit except where the HW needs to differentiate between them, and you don’t need reg or a node address to do it.
> 

As I mentioned above, we need the hardware numbers to enable the "specific" port.

E.g, :

static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
{
         u32 functl;

         CS_UNLOCK(drvdata->base);

         functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
         functl &= ~FUNNEL_HOLDTIME_MASK;
         functl |= FUNNEL_HOLDTIME;
         functl |= (1 << port);
         writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
         writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);

         CS_LOCK(drvdata->base);
}


> If you really need to parse full graphs in both directions (find root, find leaf) then could we simply introduce properties which list the phandles of all uplink sources, as linked lists point to the list head?

No we don't need to parse it in both ways, up and down. Btw, the trace paths
are not statically created. They are done at runtime, as configured by the
user. So all we need to do is have a list of the ports and the devices it
is connected to (of course with direction information). I would stay
away from duplicating the platform code when something already does
a good job.

> 
> This gives a way to validate that the graph starts and ends the way we expect, and also allows every port to be associated with being a required path between any two devices without parsing the *whole* graph (although you still need to do that to find the route to sinks).

Coming back to your suggestion of "unit", what does it imply ?
Its too generic a term for something as concrete as a port number.

Cheers
Suzuki

> 
> Ta,
> Matt
> 
> Sent from my iPhone
> 
>> On Jun 13, 2018, at 04:45, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
>>
>> Hi Rob,
>>
>>> On 12/06/18 21:48, Rob Herring wrote:
>>>> On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
>>>> The coresight drivers relied on default bindings for graph
>>>> in DT, while reusing the "reg" field of the "ports" to indicate
>>>> the actual hardware port number for the connections. However,
>>>> with the rules getting stricter w.r.t to the address mismatch
>>>> with the label, it is no longer possible to use the port address
>>>> field for the hardware port number. Hence, we add an explicit
>>>> property to denote the hardware port number, "coresight,hwid"
>>>> which must be specified for each "endpoint".
>>>>
>>>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>> Cc: Sudeep Holla <sudeep.holla@arm.com>
>>>> Cc: Rob Herring <robh@kernel.org>
>>>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>>>> ---
>>>>   .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>>>>   drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>>>>   2 files changed, 54 insertions(+), 18 deletions(-)
>>>>
>>>> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
>>>> index bd36e40..385581a 100644
>>>> --- a/Documentation/devicetree/bindings/arm/coresight.txt
>>>> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
>>>> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>>>>       "slave-mode"
>>>>      * Hardware Port number at the component:
>>>> -     -  The hardware port number is assumed to be the address of the "port" component.
>>>> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
>>>> +   - Each "endpoint" must define the hardware port of the local end of the
>>>> +     connection using the following property:
>>>> +    "coresight,hwid" - 32bit integer, hardware port number at the local end.
>>> "coresight" is not a vendor and properties are in the form
>>> [<vendor>,]<prop-name>.
>>
>> OK. The issue here is that a coresight component could be an Arm IP or
>> a custom partner IP. So, the vendor could be either arm or the partner id.
>> However, this property is kind of a generic one for the Coresight family,
>> which is why we opted for "coresight". What is the guideline for such
>> cases ?
>>
>> Or in other words I see the following possible options :
>>
>> 1) coresight,hwid    - coresight generic
>> 2) arm,coresight-hwid    - arm vendor, however the device could be from any vendor.
>> 3) hwid            - Generic
>> 4) none of the above, something completely different.
>>
>> What do you recommend from the above ?
>>
>>>> +
>>>>       Example:
>>>> @@ -120,6 +124,7 @@ Example:
>>>>               etb_in_port: endpoint@0 {
>>> There shouldn't be a unit address here because there is no reg property.
>>>>                   slave-mode;
>>>>                   remote-endpoint = <&replicator_out_port0>;
>>>> +                coresight,hwid = <0>;
>>> It doesn't make sense for these to be in the endpoint. If you had
>>> multiple endpoints, then you would have to duplicate it. "ports" are
>>> a single data stream. "endpoints" are connections to that stream. So if
>>> you have a muxed (input) or fanout/1-to-many (output) connection, then
>>> you have multiple endpoints.
>>
>> We do have many-to-1 input (e.g, funnels) and 1-to-many outputs
>> (e.g replicators). However, we have (so far) used only one endpoint per
>> port.
>>
>> Also we could potentially have multiple data streams flowing through
>> the ports, which gets filtered to different ports in 1-to-many components
>> (read programmable-replicator).
>>
>> So the point is we have a shared path which carries different data
>> streams with mux/demux components. I am open for suggestions based on
>> the above facts.
>>
>>> The same applied to the slave-mode property, but that ship has sailed.
>>> No reason to continue that though.
>>>>               };
>>>>           };
>>>>       };
>>>> @@ -134,6 +139,7 @@ Example:
>>>>               tpiu_in_port: endpoint@0 {
>>>>                   slave-mode;
>>>>                   remote-endpoint = <&replicator_out_port1>;
>>>> +                coresight,hwid = <0>;
>>>>               };
>>>>           };
>>>>       };
>>>> @@ -154,6 +160,7 @@ Example:
>>>>                   reg = <0>;
>>>>                   replicator_out_port0: endpoint {
>>>>                       remote-endpoint = <&etb_in_port>;
>>>> +                    coresight,hwid = <0>;
>>>>                   };
>>>>               };
>>>>   @@ -161,15 +168,17 @@ Example:
>>>>                   reg = <1>;
>>>>                   replicator_out_port1: endpoint {
>>>>                       remote-endpoint = <&tpiu_in_port>;
>>>> +                    coresight,hwid = <1>;
>>>>                   };
>>>>               };
>>>>                 /* replicator input port */
>>>>               port@2 {
>>>> -                reg = <0>;
>>>> +                reg = <1>;
>>> This will still get flagged as an error. reg must be 2 here.
>>
>> Sorry, thats a mistake. I will fix it.
>>
>> Cheers
>> Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 13:35           ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-13 13:35 UTC (permalink / raw)
  To: linux-arm-kernel

Hi Matt,

Thanks for your comments, responses inline.

On 13/06/18 13:49, Matt Sealey wrote:
> Suzuki,
> 
> Why not use ?unit??
> 
> I believe we had this discussion years ago about numbering serial ports and sdhci (i.e. how do you know it?s UART0 or UART1 from just the address? Some SoC?s don?t address sequentially *or* in a forward direction) - I believe it?s not exactly codified in ePAPR, not am I sure where it may be otherwise, but it exists.

We have different situation here. We need to know *the port number* as understood by the
hardware, so that we can enable *the specific* port for a given path.

> 
> I agree with Rob on the slave-mode nonsense, this is an SPI controller concept weirdly stuffed into a directed graph which implicitly tells you the data direction - it?s a rooted tree (just like DT!).

Btw, the "slave-mode" is not a standard DT graph binding. It is not part of the
generic DT graph binding. In fact the generic bindings stay away from the direction
aspect and explicitly mentions the same.

> 
> For the case of a funnel each device supplying trace should end up into an input node - numbered with a unit - and all those nodes should point to the output node as endpoints. Describing the hardware as a black box is probably less of a good idea than showing that it?s a funnel, or replicator by showing the internal paths. You wouldn?t need to ?number? ports with a unit except where the HW needs to differentiate between them, and you don?t need reg or a node address to do it.
> 

As I mentioned above, we need the hardware numbers to enable the "specific" port.

E.g, :

static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
{
         u32 functl;

         CS_UNLOCK(drvdata->base);

         functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
         functl &= ~FUNNEL_HOLDTIME_MASK;
         functl |= FUNNEL_HOLDTIME;
         functl |= (1 << port);
         writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
         writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);

         CS_LOCK(drvdata->base);
}


> If you really need to parse full graphs in both directions (find root, find leaf) then could we simply introduce properties which list the phandles of all uplink sources, as linked lists point to the list head?

No we don't need to parse it in both ways, up and down. Btw, the trace paths
are not statically created. They are done at runtime, as configured by the
user. So all we need to do is have a list of the ports and the devices it
is connected to (of course with direction information). I would stay
away from duplicating the platform code when something already does
a good job.

> 
> This gives a way to validate that the graph starts and ends the way we expect, and also allows every port to be associated with being a required path between any two devices without parsing the *whole* graph (although you still need to do that to find the route to sinks).

Coming back to your suggestion of "unit", what does it imply ?
Its too generic a term for something as concrete as a port number.

Cheers
Suzuki

> 
> Ta,
> Matt
> 
> Sent from my iPhone
> 
>> On Jun 13, 2018, at 04:45, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
>>
>> Hi Rob,
>>
>>> On 12/06/18 21:48, Rob Herring wrote:
>>>> On Fri, Jun 01, 2018 at 02:16:05PM +0100, Suzuki K Poulose wrote:
>>>> The coresight drivers relied on default bindings for graph
>>>> in DT, while reusing the "reg" field of the "ports" to indicate
>>>> the actual hardware port number for the connections. However,
>>>> with the rules getting stricter w.r.t to the address mismatch
>>>> with the label, it is no longer possible to use the port address
>>>> field for the hardware port number. Hence, we add an explicit
>>>> property to denote the hardware port number, "coresight,hwid"
>>>> which must be specified for each "endpoint".
>>>>
>>>> Cc: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>> Cc: Sudeep Holla <sudeep.holla@arm.com>
>>>> Cc: Rob Herring <robh@kernel.org>
>>>> Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
>>>> ---
>>>>   .../devicetree/bindings/arm/coresight.txt          | 26 +++++++++---
>>>>   drivers/hwtracing/coresight/of_coresight.c         | 46 ++++++++++++++++------
>>>>   2 files changed, 54 insertions(+), 18 deletions(-)
>>>>
>>>> diff --git a/Documentation/devicetree/bindings/arm/coresight.txt b/Documentation/devicetree/bindings/arm/coresight.txt
>>>> index bd36e40..385581a 100644
>>>> --- a/Documentation/devicetree/bindings/arm/coresight.txt
>>>> +++ b/Documentation/devicetree/bindings/arm/coresight.txt
>>>> @@ -104,7 +104,11 @@ properties to uniquely identify the connection details.
>>>>       "slave-mode"
>>>>      * Hardware Port number at the component:
>>>> -     -  The hardware port number is assumed to be the address of the "port" component.
>>>> +   - (Obsolete) The hardware port number is assumed to be the address of the "port" component.
>>>> +   - Each "endpoint" must define the hardware port of the local end of the
>>>> +     connection using the following property:
>>>> +    "coresight,hwid" - 32bit integer, hardware port number at the local end.
>>> "coresight" is not a vendor and properties are in the form
>>> [<vendor>,]<prop-name>.
>>
>> OK. The issue here is that a coresight component could be an Arm IP or
>> a custom partner IP. So, the vendor could be either arm or the partner id.
>> However, this property is kind of a generic one for the Coresight family,
>> which is why we opted for "coresight". What is the guideline for such
>> cases ?
>>
>> Or in other words I see the following possible options :
>>
>> 1) coresight,hwid    - coresight generic
>> 2) arm,coresight-hwid    - arm vendor, however the device could be from any vendor.
>> 3) hwid            - Generic
>> 4) none of the above, something completely different.
>>
>> What do you recommend from the above ?
>>
>>>> +
>>>>       Example:
>>>> @@ -120,6 +124,7 @@ Example:
>>>>               etb_in_port: endpoint at 0 {
>>> There shouldn't be a unit address here because there is no reg property.
>>>>                   slave-mode;
>>>>                   remote-endpoint = <&replicator_out_port0>;
>>>> +                coresight,hwid = <0>;
>>> It doesn't make sense for these to be in the endpoint. If you had
>>> multiple endpoints, then you would have to duplicate it. "ports" are
>>> a single data stream. "endpoints" are connections to that stream. So if
>>> you have a muxed (input) or fanout/1-to-many (output) connection, then
>>> you have multiple endpoints.
>>
>> We do have many-to-1 input (e.g, funnels) and 1-to-many outputs
>> (e.g replicators). However, we have (so far) used only one endpoint per
>> port.
>>
>> Also we could potentially have multiple data streams flowing through
>> the ports, which gets filtered to different ports in 1-to-many components
>> (read programmable-replicator).
>>
>> So the point is we have a shared path which carries different data
>> streams with mux/demux components. I am open for suggestions based on
>> the above facts.
>>
>>> The same applied to the slave-mode property, but that ship has sailed.
>>> No reason to continue that though.
>>>>               };
>>>>           };
>>>>       };
>>>> @@ -134,6 +139,7 @@ Example:
>>>>               tpiu_in_port: endpoint at 0 {
>>>>                   slave-mode;
>>>>                   remote-endpoint = <&replicator_out_port1>;
>>>> +                coresight,hwid = <0>;
>>>>               };
>>>>           };
>>>>       };
>>>> @@ -154,6 +160,7 @@ Example:
>>>>                   reg = <0>;
>>>>                   replicator_out_port0: endpoint {
>>>>                       remote-endpoint = <&etb_in_port>;
>>>> +                    coresight,hwid = <0>;
>>>>                   };
>>>>               };
>>>>   @@ -161,15 +168,17 @@ Example:
>>>>                   reg = <1>;
>>>>                   replicator_out_port1: endpoint {
>>>>                       remote-endpoint = <&tpiu_in_port>;
>>>> +                    coresight,hwid = <1>;
>>>>                   };
>>>>               };
>>>>                 /* replicator input port */
>>>>               port at 2 {
>>>> -                reg = <0>;
>>>> +                reg = <1>;
>>> This will still get flagged as an error. reg must be 2 here.
>>
>> Sorry, thats a mistake. I will fix it.
>>
>> Cheers
>> Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-13 13:35           ` Suzuki K Poulose
  (?)
@ 2018-06-13 13:57             ` Rob Herring
  -1 siblings, 0 replies; 77+ messages in thread
From: Rob Herring @ 2018-06-13 13:57 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: Matt Sealey, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

On Wed, Jun 13, 2018 at 7:35 AM, Suzuki K Poulose
<Suzuki.Poulose@arm.com> wrote:
> Hi Matt,
>
> Thanks for your comments, responses inline.
>
> On 13/06/18 13:49, Matt Sealey wrote:
>>
>> Suzuki,
>>
>> Why not use “unit”?
>>
>> I believe we had this discussion years ago about numbering serial ports
>> and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address?
>> Some SoC’s don’t address sequentially *or* in a forward direction) - I
>> believe it’s not exactly codified in ePAPR, not am I sure where it may be
>> otherwise, but it exists.
>
>
> We have different situation here. We need to know *the port number* as
> understood by the
> hardware, so that we can enable *the specific* port for a given path.
>
>>
>> I agree with Rob on the slave-mode nonsense, this is an SPI controller
>> concept weirdly stuffed into a directed graph which implicitly tells you the
>> data direction - it’s a rooted tree (just like DT!).

OF graph is not directional. All links must be bi-directional and in
fact dtc checks that now. The parent node should know the numbering
and direction of each port.

> Btw, the "slave-mode" is not a standard DT graph binding. It is not part of
> the
> generic DT graph binding. In fact the generic bindings stay away from the
> direction
> aspect and explicitly mentions the same.

I really don't like slave-mode nor coresight,hwid.

I would prefer to see getting rid of both and splitting ports into
"in-ports" and "out-ports" nodes instead of a single "ports" node.
Then you don't need any of these properties and reg can be used as the
hwid.

Rob

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 13:57             ` Rob Herring
  0 siblings, 0 replies; 77+ messages in thread
From: Rob Herring @ 2018-06-13 13:57 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: Matt Sealey, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

On Wed, Jun 13, 2018 at 7:35 AM, Suzuki K Poulose
<Suzuki.Poulose@arm.com> wrote:
> Hi Matt,
>
> Thanks for your comments, responses inline.
>
> On 13/06/18 13:49, Matt Sealey wrote:
>>
>> Suzuki,
>>
>> Why not use “unit”?
>>
>> I believe we had this discussion years ago about numbering serial ports
>> and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address?
>> Some SoC’s don’t address sequentially *or* in a forward direction) - I
>> believe it’s not exactly codified in ePAPR, not am I sure where it may be
>> otherwise, but it exists.
>
>
> We have different situation here. We need to know *the port number* as
> understood by the
> hardware, so that we can enable *the specific* port for a given path.
>
>>
>> I agree with Rob on the slave-mode nonsense, this is an SPI controller
>> concept weirdly stuffed into a directed graph which implicitly tells you the
>> data direction - it’s a rooted tree (just like DT!).

OF graph is not directional. All links must be bi-directional and in
fact dtc checks that now. The parent node should know the numbering
and direction of each port.

> Btw, the "slave-mode" is not a standard DT graph binding. It is not part of
> the
> generic DT graph binding. In fact the generic bindings stay away from the
> direction
> aspect and explicitly mentions the same.

I really don't like slave-mode nor coresight,hwid.

I would prefer to see getting rid of both and splitting ports into
"in-ports" and "out-ports" nodes instead of a single "ports" node.
Then you don't need any of these properties and reg can be used as the
hwid.

Rob

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 13:57             ` Rob Herring
  0 siblings, 0 replies; 77+ messages in thread
From: Rob Herring @ 2018-06-13 13:57 UTC (permalink / raw)
  To: linux-arm-kernel

On Wed, Jun 13, 2018 at 7:35 AM, Suzuki K Poulose
<Suzuki.Poulose@arm.com> wrote:
> Hi Matt,
>
> Thanks for your comments, responses inline.
>
> On 13/06/18 13:49, Matt Sealey wrote:
>>
>> Suzuki,
>>
>> Why not use ?unit??
>>
>> I believe we had this discussion years ago about numbering serial ports
>> and sdhci (i.e. how do you know it?s UART0 or UART1 from just the address?
>> Some SoC?s don?t address sequentially *or* in a forward direction) - I
>> believe it?s not exactly codified in ePAPR, not am I sure where it may be
>> otherwise, but it exists.
>
>
> We have different situation here. We need to know *the port number* as
> understood by the
> hardware, so that we can enable *the specific* port for a given path.
>
>>
>> I agree with Rob on the slave-mode nonsense, this is an SPI controller
>> concept weirdly stuffed into a directed graph which implicitly tells you the
>> data direction - it?s a rooted tree (just like DT!).

OF graph is not directional. All links must be bi-directional and in
fact dtc checks that now. The parent node should know the numbering
and direction of each port.

> Btw, the "slave-mode" is not a standard DT graph binding. It is not part of
> the
> generic DT graph binding. In fact the generic bindings stay away from the
> direction
> aspect and explicitly mentions the same.

I really don't like slave-mode nor coresight,hwid.

I would prefer to see getting rid of both and splitting ports into
"in-ports" and "out-ports" nodes instead of a single "ports" node.
Then you don't need any of these properties and reg can be used as the
hwid.

Rob

^ permalink raw reply	[flat|nested] 77+ messages in thread

* RE: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-13 13:35           ` Suzuki K Poulose
  (?)
@ 2018-06-13 15:47             ` Matt Sealey
  -1 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 15:47 UTC (permalink / raw)
  To: Suzuki Poulose
  Cc: Rob Herring, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Suzuki,

> > Why not use “unit”?
> >
> > I believe we had this discussion years ago about numbering serial ports
> > and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address?
> > Some SoC’s don’t address sequentially *or* in a forward direction) - I
> > believe it’s not exactly codified in ePAPR, not am I sure where it may be
> > otherwise, but it exists.
>
> We have different situation here. We need to know *the port number* as
> understood by the hardware, so that we can enable *the specific* port for
> a given path.

For the purposes of abstraction, each port will have the property of having
a node which is pointed to by other nodes, and in the case of a true ATB
endpoint, no other nodes behind it.

It doesn't matter what the HW numbers it as as long as the driver can derive
it from whatever you put in the DT. So a funnel (which is ~8 ports muxed into
one output):

   f1p0: port {
      unit = <0>;
      endpoint = <&f1out>;
   };
   f1p1: port {
      unit = <4>;
      endpoint = <&f1out>;
   };
   f1out: port {
      endpoint = <&etf1>;
   };

"unit" here is specific to the driver's understanding of ports within it's
own cycle of the graph. For a replicator you can invert the logic - input
ports don't need a unit, but the two outputs are filtered in CoreSight not
by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
you would want to describe all 8 possible units on each leg with the first
ID it would filter? Or just list tuples of filter IDs <id, first, last>

Who cares, really, as long as the driver knows what it means.

You don't need to namespace every property.

> As I mentioned above, we need the hardware numbers to enable the
> "specific" port.

Okay and how is this not able to be prescribed in a binding for "arm,coresight-funnel"
that:

"input ports are numbered from 0 to N where N is the maximum input port
number. This number is identified with the "unit" property, which directly
corresponds to the bit position in the funnel Ctrl_Reg register, and the
bit position multiplied by 3 for each 3-bit priority in the funnel
Priority_Ctrl_Reg, with N having a maximum of the defined register bitfield
DEVID[PORTCOUNT], minus one, for that component"

Or a replicator:

"output ports are numbered per the CoreSight ATB Replicator specification,
unit corresponding to the IDFILTERn register controlling ID filters for
that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
minus one"

One could clarify it, even, with labels for readability ("label" definitely
is a well defined if also completely arbitrary property).

..

> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
> {
>          u32 functl;
>
>          CS_UNLOCK(drvdata->base);
>
>          functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>          functl &= ~FUNNEL_HOLDTIME_MASK;
>          functl |= FUNNEL_HOLDTIME;
>          functl |= (1 << port);
>          writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>          writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);
>
>          CS_LOCK(drvdata->base);
> }
>
> No we don't need to parse it in both ways, up and down. Btw, the trace
> paths are not statically created. They are done at runtime, as configured
> by the user.

You do realize this isn't how the hardware works, correct?

Trace paths are fixed, they may diverge with different configurations, but
the full CoreSight topology (all funnels, replicators and intermediary
Components) is entirely unchangeable.

The DT should provide the information to provide a reference acyclic directed
graph of the entire topology (or entirely reasonably programmable topology where
at all possible) - if a user wants to trace from ETM_0 then they only
have particular paths to particular sinks, for instance ETM_0 and ETF_0
may be on their own path, so you cannot just "configure as a user"
a path from ETM_1 to ETF_0 since there isn't one.

Walking said graphs with the knowledge that CoreSight specifically disallows
loopbacks in ATB topology is basic computer science problem - literally a
matter of topological sorting. But let's build a graph once and traverse it -
don't build the graph partially each time or try and build it to cross-check
every time. The paths are wires in the design, lets not fake to the user
that there is any configurability in that or try and encode that in the
DT.

> Coming back to your suggestion of "unit", what does it imply ?

Whatever the driver likes. For uart and mmc, it was just a spurious number
but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
in any other driver-specific manner. The number you put in is up to you,
but the valid numbers would be in the binding for that particular device.

> Its too generic a term for something as concrete as a port number.

Is it?

Why would you need a whole other property type to encode a u32 that
describes an arbitrary number specific to that hardware device?

Ta,
Matt


IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* RE: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 15:47             ` Matt Sealey
  0 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 15:47 UTC (permalink / raw)
  To: Suzuki Poulose
  Cc: Rob Herring, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Suzuki,

> > Why not use “unit”?
> >
> > I believe we had this discussion years ago about numbering serial ports
> > and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address?
> > Some SoC’s don’t address sequentially *or* in a forward direction) - I
> > believe it’s not exactly codified in ePAPR, not am I sure where it may be
> > otherwise, but it exists.
>
> We have different situation here. We need to know *the port number* as
> understood by the hardware, so that we can enable *the specific* port for
> a given path.

For the purposes of abstraction, each port will have the property of having
a node which is pointed to by other nodes, and in the case of a true ATB
endpoint, no other nodes behind it.

It doesn't matter what the HW numbers it as as long as the driver can derive
it from whatever you put in the DT. So a funnel (which is ~8 ports muxed into
one output):

   f1p0: port {
      unit = <0>;
      endpoint = <&f1out>;
   };
   f1p1: port {
      unit = <4>;
      endpoint = <&f1out>;
   };
   f1out: port {
      endpoint = <&etf1>;
   };

"unit" here is specific to the driver's understanding of ports within it's
own cycle of the graph. For a replicator you can invert the logic - input
ports don't need a unit, but the two outputs are filtered in CoreSight not
by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
you would want to describe all 8 possible units on each leg with the first
ID it would filter? Or just list tuples of filter IDs <id, first, last>

Who cares, really, as long as the driver knows what it means.

You don't need to namespace every property.

> As I mentioned above, we need the hardware numbers to enable the
> "specific" port.

Okay and how is this not able to be prescribed in a binding for "arm,coresight-funnel"
that:

"input ports are numbered from 0 to N where N is the maximum input port
number. This number is identified with the "unit" property, which directly
corresponds to the bit position in the funnel Ctrl_Reg register, and the
bit position multiplied by 3 for each 3-bit priority in the funnel
Priority_Ctrl_Reg, with N having a maximum of the defined register bitfield
DEVID[PORTCOUNT], minus one, for that component"

Or a replicator:

"output ports are numbered per the CoreSight ATB Replicator specification,
unit corresponding to the IDFILTERn register controlling ID filters for
that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
minus one"

One could clarify it, even, with labels for readability ("label" definitely
is a well defined if also completely arbitrary property).

..

> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
> {
>          u32 functl;
>
>          CS_UNLOCK(drvdata->base);
>
>          functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>          functl &= ~FUNNEL_HOLDTIME_MASK;
>          functl |= FUNNEL_HOLDTIME;
>          functl |= (1 << port);
>          writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>          writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);
>
>          CS_LOCK(drvdata->base);
> }
>
> No we don't need to parse it in both ways, up and down. Btw, the trace
> paths are not statically created. They are done at runtime, as configured
> by the user.

You do realize this isn't how the hardware works, correct?

Trace paths are fixed, they may diverge with different configurations, but
the full CoreSight topology (all funnels, replicators and intermediary
Components) is entirely unchangeable.

The DT should provide the information to provide a reference acyclic directed
graph of the entire topology (or entirely reasonably programmable topology where
at all possible) - if a user wants to trace from ETM_0 then they only
have particular paths to particular sinks, for instance ETM_0 and ETF_0
may be on their own path, so you cannot just "configure as a user"
a path from ETM_1 to ETF_0 since there isn't one.

Walking said graphs with the knowledge that CoreSight specifically disallows
loopbacks in ATB topology is basic computer science problem - literally a
matter of topological sorting. But let's build a graph once and traverse it -
don't build the graph partially each time or try and build it to cross-check
every time. The paths are wires in the design, lets not fake to the user
that there is any configurability in that or try and encode that in the
DT.

> Coming back to your suggestion of "unit", what does it imply ?

Whatever the driver likes. For uart and mmc, it was just a spurious number
but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
in any other driver-specific manner. The number you put in is up to you,
but the valid numbers would be in the binding for that particular device.

> Its too generic a term for something as concrete as a port number.

Is it?

Why would you need a whole other property type to encode a u32 that
describes an arbitrary number specific to that hardware device?

Ta,
Matt


IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 15:47             ` Matt Sealey
  0 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 15:47 UTC (permalink / raw)
  To: linux-arm-kernel

Hi Suzuki,

> > Why not use ?unit??
> >
> > I believe we had this discussion years ago about numbering serial ports
> > and sdhci (i.e. how do you know it?s UART0 or UART1 from just the address?
> > Some SoC?s don?t address sequentially *or* in a forward direction) - I
> > believe it?s not exactly codified in ePAPR, not am I sure where it may be
> > otherwise, but it exists.
>
> We have different situation here. We need to know *the port number* as
> understood by the hardware, so that we can enable *the specific* port for
> a given path.

For the purposes of abstraction, each port will have the property of having
a node which is pointed to by other nodes, and in the case of a true ATB
endpoint, no other nodes behind it.

It doesn't matter what the HW numbers it as as long as the driver can derive
it from whatever you put in the DT. So a funnel (which is ~8 ports muxed into
one output):

   f1p0: port {
      unit = <0>;
      endpoint = <&f1out>;
   };
   f1p1: port {
      unit = <4>;
      endpoint = <&f1out>;
   };
   f1out: port {
      endpoint = <&etf1>;
   };

"unit" here is specific to the driver's understanding of ports within it's
own cycle of the graph. For a replicator you can invert the logic - input
ports don't need a unit, but the two outputs are filtered in CoreSight not
by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
you would want to describe all 8 possible units on each leg with the first
ID it would filter? Or just list tuples of filter IDs <id, first, last>

Who cares, really, as long as the driver knows what it means.

You don't need to namespace every property.

> As I mentioned above, we need the hardware numbers to enable the
> "specific" port.

Okay and how is this not able to be prescribed in a binding for "arm,coresight-funnel"
that:

"input ports are numbered from 0 to N where N is the maximum input port
number. This number is identified with the "unit" property, which directly
corresponds to the bit position in the funnel Ctrl_Reg register, and the
bit position multiplied by 3 for each 3-bit priority in the funnel
Priority_Ctrl_Reg, with N having a maximum of the defined register bitfield
DEVID[PORTCOUNT], minus one, for that component"

Or a replicator:

"output ports are numbered per the CoreSight ATB Replicator specification,
unit corresponding to the IDFILTERn register controlling ID filters for
that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
minus one"

One could clarify it, even, with labels for readability ("label" definitely
is a well defined if also completely arbitrary property).

..

> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
> {
>          u32 functl;
>
>          CS_UNLOCK(drvdata->base);
>
>          functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>          functl &= ~FUNNEL_HOLDTIME_MASK;
>          functl |= FUNNEL_HOLDTIME;
>          functl |= (1 << port);
>          writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>          writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);
>
>          CS_LOCK(drvdata->base);
> }
>
> No we don't need to parse it in both ways, up and down. Btw, the trace
> paths are not statically created. They are done at runtime, as configured
> by the user.

You do realize this isn't how the hardware works, correct?

Trace paths are fixed, they may diverge with different configurations, but
the full CoreSight topology (all funnels, replicators and intermediary
Components) is entirely unchangeable.

The DT should provide the information to provide a reference acyclic directed
graph of the entire topology (or entirely reasonably programmable topology where
at all possible) - if a user wants to trace from ETM_0 then they only
have particular paths to particular sinks, for instance ETM_0 and ETF_0
may be on their own path, so you cannot just "configure as a user"
a path from ETM_1 to ETF_0 since there isn't one.

Walking said graphs with the knowledge that CoreSight specifically disallows
loopbacks in ATB topology is basic computer science problem - literally a
matter of topological sorting. But let's build a graph once and traverse it -
don't build the graph partially each time or try and build it to cross-check
every time. The paths are wires in the design, lets not fake to the user
that there is any configurability in that or try and encode that in the
DT.

> Coming back to your suggestion of "unit", what does it imply ?

Whatever the driver likes. For uart and mmc, it was just a spurious number
but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
in any other driver-specific manner. The number you put in is up to you,
but the valid numbers would be in the binding for that particular device.

> Its too generic a term for something as concrete as a port number.

Is it?

Why would you need a whole other property type to encode a u32 that
describes an arbitrary number specific to that hardware device?

Ta,
Matt


IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-13 15:47             ` Matt Sealey
  (?)
@ 2018-06-13 17:07               ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-13 17:07 UTC (permalink / raw)
  To: Matt Sealey
  Cc: Rob Herring, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Matt,

On 13/06/18 16:47, Matt Sealey wrote:
> Hi Suzuki,
> 
>>> Why not use “unit”?
>>>
>>> I believe we had this discussion years ago about numbering serial ports
>>> and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address?
>>> Some SoC’s don’t address sequentially *or* in a forward direction) - I
>>> believe it’s not exactly codified in ePAPR, not am I sure where it may be
>>> otherwise, but it exists.
>>
>> We have different situation here. We need to know *the port number* as
>> understood by the hardware, so that we can enable *the specific* port for
>> a given path.
> 
> For the purposes of abstraction, each port will have the property of having
> a node which is pointed to by other nodes, and in the case of a true ATB
> endpoint, no other nodes behind it.
> 
> It doesn't matter what the HW numbers it as as long as the driver can derive
> it from whatever you put in the DT. So a funnel (which is ~8 ports muxed into
> one output):
> 
>     f1p0: port {
>        unit = <0>;
>        endpoint = <&f1out>;
>     };
>     f1p1: port {
>        unit = <4>;
>        endpoint = <&f1out>;
>     };
>     f1out: port {
>        endpoint = <&etf1>;
>     };
> 
> "unit" here is specific to the driver's understanding of ports within it's

I may be missing, but is "unit" something that already exists and used by
DT bindings already ? Or is this something new that we are proposing ?

> own cycle of the graph. For a replicator you can invert the logic - input
> ports don't need a unit, but the two outputs are filtered in CoreSight not

I would prefer to make the new property mandatory for all the ports to avoid
a potential problem in the future.

How do you represent a TMC-ETF which has one input and one output connection ?
Also what happens if we ever get a component which has m-to-n connections ?

> by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
> you would want to describe all 8 possible units on each leg with the first
> ID it would filter? Or just list tuples of filter IDs <id, first, last>

I am failing to follow the ATB ID group description above. As per the TRM,
e.g, replicator filters the "trace stream" based on the "trace ID", which I
believe can be programmed via IDFILTER<n> register. So why would we need that
to be part of the DT ?

> 
> Who cares, really, as long as the driver knows what it means.
> 
> You don't need to namespace every property.
> 
>> As I mentioned above, we need the hardware numbers to enable the
>> "specific" port.
> 
> Okay and how is this not able to be prescribed in a binding for "arm,coresight-funnel"
> that:
> 
> "input ports are numbered from 0 to N where N is the maximum input port
> number. This number is identified with the "unit" property, which directly
> corresponds to the bit position in the funnel Ctrl_Reg register, and the
> bit position multiplied by 3 for each 3-bit priority in the funnel
> Priority_Ctrl_Reg, with N having a maximum of the defined register bitfield
> DEVID[PORTCOUNT], minus one, for that component"

The description looks over complicated to me at least, even after having known
bit of the programming interface of the components. I would prefer staying
closer to the terms used in the TRM ("slave/master" interfaces) and make it
easier for people to write the DT.

> 
> Or a replicator:
> 
> "output ports are numbered per the CoreSight ATB Replicator specification,
> unit corresponding to the IDFILTERn register controlling ID filters for
> that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
> minus one"
> 
> One could clarify it, even, with labels for readability ("label" definitely
> is a well defined if also completely arbitrary property).
> 
> ..
> 
>> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
>> {
>>           u32 functl;
>>
>>           CS_UNLOCK(drvdata->base);
>>
>>           functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>>           functl &= ~FUNNEL_HOLDTIME_MASK;
>>           functl |= FUNNEL_HOLDTIME;
>>           functl |= (1 << port);
>>           writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>>           writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);
>>
>>           CS_LOCK(drvdata->base);
>> }
>>
>> No we don't need to parse it in both ways, up and down. Btw, the trace
>> paths are not statically created. They are done at runtime, as configured
>> by the user.
> 
> You do realize this isn't how the hardware works, correct?

The "trace paths" mentioned above were indeed the software path, which
was constructed at runtime. The graph connections are indeed a one time
parsing at probe time and as you said they don't change. And by configuring,
I mean selecting the "source" and the "sink".

> 
> Trace paths are fixed, they may diverge with different configurations, but
> the full CoreSight topology (all funnels, replicators and intermediary
> Components) is entirely unchangeable.
> 
> The DT should provide the information to provide a reference acyclic directed
> graph of the entire topology (or entirely reasonably programmable topology where
> at all possible) - if a user wants to trace from ETM_0 then they only
> have particular paths to particular sinks, for instance ETM_0 and ETF_0
> may be on their own path, so you cannot just "configure as a user"
> a path from ETM_1 to ETF_0 since there isn't one.

> 
> Walking said graphs with the knowledge that CoreSight specifically disallows
> loopbacks in ATB topology is basic computer science problem - literally a
> matter of topological sorting. But let's build a graph once and traverse it -
> don't build the graph partially each time or try and build it to cross-check
> every time. The paths are wires in the design, lets not fake to the user
> that there is any configurability in that or try and encode that in the
> DT.

Sorry for the confusion, as explained above, it is indeed a one time pass.

> 
>> Coming back to your suggestion of "unit", what does it imply ?
> 
> Whatever the driver likes. For uart and mmc, it was just a spurious number
> but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
> in any other driver-specific manner. The number you put in is up to you,
> but the valid numbers would be in the binding for that particular device.
> 
>> Its too generic a term for something as concrete as a port number.
> 
> Is it?
> 
> Why would you need a whole other property type to encode a u32 that
> describes an arbitrary number specific to that hardware device?

So, if the suggestion is to use an existing property "unit", I am fine
with it, if people agree to it.


Thanks for the comments.

Cheers,
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 17:07               ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-13 17:07 UTC (permalink / raw)
  To: Matt Sealey
  Cc: Rob Herring, linux-arm-kernel, mathieu.poirier, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Matt,

On 13/06/18 16:47, Matt Sealey wrote:
> Hi Suzuki,
> 
>>> Why not use “unit”?
>>>
>>> I believe we had this discussion years ago about numbering serial ports
>>> and sdhci (i.e. how do you know it’s UART0 or UART1 from just the address?
>>> Some SoC’s don’t address sequentially *or* in a forward direction) - I
>>> believe it’s not exactly codified in ePAPR, not am I sure where it may be
>>> otherwise, but it exists.
>>
>> We have different situation here. We need to know *the port number* as
>> understood by the hardware, so that we can enable *the specific* port for
>> a given path.
> 
> For the purposes of abstraction, each port will have the property of having
> a node which is pointed to by other nodes, and in the case of a true ATB
> endpoint, no other nodes behind it.
> 
> It doesn't matter what the HW numbers it as as long as the driver can derive
> it from whatever you put in the DT. So a funnel (which is ~8 ports muxed into
> one output):
> 
>     f1p0: port {
>        unit = <0>;
>        endpoint = <&f1out>;
>     };
>     f1p1: port {
>        unit = <4>;
>        endpoint = <&f1out>;
>     };
>     f1out: port {
>        endpoint = <&etf1>;
>     };
> 
> "unit" here is specific to the driver's understanding of ports within it's

I may be missing, but is "unit" something that already exists and used by
DT bindings already ? Or is this something new that we are proposing ?

> own cycle of the graph. For a replicator you can invert the logic - input
> ports don't need a unit, but the two outputs are filtered in CoreSight not

I would prefer to make the new property mandatory for all the ports to avoid
a potential problem in the future.

How do you represent a TMC-ETF which has one input and one output connection ?
Also what happens if we ever get a component which has m-to-n connections ?

> by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
> you would want to describe all 8 possible units on each leg with the first
> ID it would filter? Or just list tuples of filter IDs <id, first, last>

I am failing to follow the ATB ID group description above. As per the TRM,
e.g, replicator filters the "trace stream" based on the "trace ID", which I
believe can be programmed via IDFILTER<n> register. So why would we need that
to be part of the DT ?

> 
> Who cares, really, as long as the driver knows what it means.
> 
> You don't need to namespace every property.
> 
>> As I mentioned above, we need the hardware numbers to enable the
>> "specific" port.
> 
> Okay and how is this not able to be prescribed in a binding for "arm,coresight-funnel"
> that:
> 
> "input ports are numbered from 0 to N where N is the maximum input port
> number. This number is identified with the "unit" property, which directly
> corresponds to the bit position in the funnel Ctrl_Reg register, and the
> bit position multiplied by 3 for each 3-bit priority in the funnel
> Priority_Ctrl_Reg, with N having a maximum of the defined register bitfield
> DEVID[PORTCOUNT], minus one, for that component"

The description looks over complicated to me at least, even after having known
bit of the programming interface of the components. I would prefer staying
closer to the terms used in the TRM ("slave/master" interfaces) and make it
easier for people to write the DT.

> 
> Or a replicator:
> 
> "output ports are numbered per the CoreSight ATB Replicator specification,
> unit corresponding to the IDFILTERn register controlling ID filters for
> that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
> minus one"
> 
> One could clarify it, even, with labels for readability ("label" definitely
> is a well defined if also completely arbitrary property).
> 
> ..
> 
>> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
>> {
>>           u32 functl;
>>
>>           CS_UNLOCK(drvdata->base);
>>
>>           functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>>           functl &= ~FUNNEL_HOLDTIME_MASK;
>>           functl |= FUNNEL_HOLDTIME;
>>           functl |= (1 << port);
>>           writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>>           writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);
>>
>>           CS_LOCK(drvdata->base);
>> }
>>
>> No we don't need to parse it in both ways, up and down. Btw, the trace
>> paths are not statically created. They are done at runtime, as configured
>> by the user.
> 
> You do realize this isn't how the hardware works, correct?

The "trace paths" mentioned above were indeed the software path, which
was constructed at runtime. The graph connections are indeed a one time
parsing at probe time and as you said they don't change. And by configuring,
I mean selecting the "source" and the "sink".

> 
> Trace paths are fixed, they may diverge with different configurations, but
> the full CoreSight topology (all funnels, replicators and intermediary
> Components) is entirely unchangeable.
> 
> The DT should provide the information to provide a reference acyclic directed
> graph of the entire topology (or entirely reasonably programmable topology where
> at all possible) - if a user wants to trace from ETM_0 then they only
> have particular paths to particular sinks, for instance ETM_0 and ETF_0
> may be on their own path, so you cannot just "configure as a user"
> a path from ETM_1 to ETF_0 since there isn't one.

> 
> Walking said graphs with the knowledge that CoreSight specifically disallows
> loopbacks in ATB topology is basic computer science problem - literally a
> matter of topological sorting. But let's build a graph once and traverse it -
> don't build the graph partially each time or try and build it to cross-check
> every time. The paths are wires in the design, lets not fake to the user
> that there is any configurability in that or try and encode that in the
> DT.

Sorry for the confusion, as explained above, it is indeed a one time pass.

> 
>> Coming back to your suggestion of "unit", what does it imply ?
> 
> Whatever the driver likes. For uart and mmc, it was just a spurious number
> but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
> in any other driver-specific manner. The number you put in is up to you,
> but the valid numbers would be in the binding for that particular device.
> 
>> Its too generic a term for something as concrete as a port number.
> 
> Is it?
> 
> Why would you need a whole other property type to encode a u32 that
> describes an arbitrary number specific to that hardware device?

So, if the suggestion is to use an existing property "unit", I am fine
with it, if people agree to it.


Thanks for the comments.

Cheers,
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 17:07               ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-13 17:07 UTC (permalink / raw)
  To: linux-arm-kernel

Hi Matt,

On 13/06/18 16:47, Matt Sealey wrote:
> Hi Suzuki,
> 
>>> Why not use ?unit??
>>>
>>> I believe we had this discussion years ago about numbering serial ports
>>> and sdhci (i.e. how do you know it?s UART0 or UART1 from just the address?
>>> Some SoC?s don?t address sequentially *or* in a forward direction) - I
>>> believe it?s not exactly codified in ePAPR, not am I sure where it may be
>>> otherwise, but it exists.
>>
>> We have different situation here. We need to know *the port number* as
>> understood by the hardware, so that we can enable *the specific* port for
>> a given path.
> 
> For the purposes of abstraction, each port will have the property of having
> a node which is pointed to by other nodes, and in the case of a true ATB
> endpoint, no other nodes behind it.
> 
> It doesn't matter what the HW numbers it as as long as the driver can derive
> it from whatever you put in the DT. So a funnel (which is ~8 ports muxed into
> one output):
> 
>     f1p0: port {
>        unit = <0>;
>        endpoint = <&f1out>;
>     };
>     f1p1: port {
>        unit = <4>;
>        endpoint = <&f1out>;
>     };
>     f1out: port {
>        endpoint = <&etf1>;
>     };
> 
> "unit" here is specific to the driver's understanding of ports within it's

I may be missing, but is "unit" something that already exists and used by
DT bindings already ? Or is this something new that we are proposing ?

> own cycle of the graph. For a replicator you can invert the logic - input
> ports don't need a unit, but the two outputs are filtered in CoreSight not

I would prefer to make the new property mandatory for all the ports to avoid
a potential problem in the future.

How do you represent a TMC-ETF which has one input and one output connection ?
Also what happens if we ever get a component which has m-to-n connections ?

> by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
> you would want to describe all 8 possible units on each leg with the first
> ID it would filter? Or just list tuples of filter IDs <id, first, last>

I am failing to follow the ATB ID group description above. As per the TRM,
e.g, replicator filters the "trace stream" based on the "trace ID", which I
believe can be programmed via IDFILTER<n> register. So why would we need that
to be part of the DT ?

> 
> Who cares, really, as long as the driver knows what it means.
> 
> You don't need to namespace every property.
> 
>> As I mentioned above, we need the hardware numbers to enable the
>> "specific" port.
> 
> Okay and how is this not able to be prescribed in a binding for "arm,coresight-funnel"
> that:
> 
> "input ports are numbered from 0 to N where N is the maximum input port
> number. This number is identified with the "unit" property, which directly
> corresponds to the bit position in the funnel Ctrl_Reg register, and the
> bit position multiplied by 3 for each 3-bit priority in the funnel
> Priority_Ctrl_Reg, with N having a maximum of the defined register bitfield
> DEVID[PORTCOUNT], minus one, for that component"

The description looks over complicated to me at least, even after having known
bit of the programming interface of the components. I would prefer staying
closer to the terms used in the TRM ("slave/master" interfaces) and make it
easier for people to write the DT.

> 
> Or a replicator:
> 
> "output ports are numbered per the CoreSight ATB Replicator specification,
> unit corresponding to the IDFILTERn register controlling ID filters for
> that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
> minus one"
> 
> One could clarify it, even, with labels for readability ("label" definitely
> is a well defined if also completely arbitrary property).
> 
> ..
> 
>> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
>> {
>>           u32 functl;
>>
>>           CS_UNLOCK(drvdata->base);
>>
>>           functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>>           functl &= ~FUNNEL_HOLDTIME_MASK;
>>           functl |= FUNNEL_HOLDTIME;
>>           functl |= (1 << port);
>>           writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>>           writel_relaxed(drvdata->priority, drvdata->base + FUNNEL_PRICTL);
>>
>>           CS_LOCK(drvdata->base);
>> }
>>
>> No we don't need to parse it in both ways, up and down. Btw, the trace
>> paths are not statically created. They are done at runtime, as configured
>> by the user.
> 
> You do realize this isn't how the hardware works, correct?

The "trace paths" mentioned above were indeed the software path, which
was constructed at runtime. The graph connections are indeed a one time
parsing at probe time and as you said they don't change. And by configuring,
I mean selecting the "source" and the "sink".

> 
> Trace paths are fixed, they may diverge with different configurations, but
> the full CoreSight topology (all funnels, replicators and intermediary
> Components) is entirely unchangeable.
> 
> The DT should provide the information to provide a reference acyclic directed
> graph of the entire topology (or entirely reasonably programmable topology where
> at all possible) - if a user wants to trace from ETM_0 then they only
> have particular paths to particular sinks, for instance ETM_0 and ETF_0
> may be on their own path, so you cannot just "configure as a user"
> a path from ETM_1 to ETF_0 since there isn't one.

> 
> Walking said graphs with the knowledge that CoreSight specifically disallows
> loopbacks in ATB topology is basic computer science problem - literally a
> matter of topological sorting. But let's build a graph once and traverse it -
> don't build the graph partially each time or try and build it to cross-check
> every time. The paths are wires in the design, lets not fake to the user
> that there is any configurability in that or try and encode that in the
> DT.

Sorry for the confusion, as explained above, it is indeed a one time pass.

> 
>> Coming back to your suggestion of "unit", what does it imply ?
> 
> Whatever the driver likes. For uart and mmc, it was just a spurious number
> but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
> in any other driver-specific manner. The number you put in is up to you,
> but the valid numbers would be in the binding for that particular device.
> 
>> Its too generic a term for something as concrete as a port number.
> 
> Is it?
> 
> Why would you need a whole other property type to encode a u32 that
> describes an arbitrary number specific to that hardware device?

So, if the suggestion is to use an existing property "unit", I am fine
with it, if people agree to it.


Thanks for the comments.

Cheers,
Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-13 17:07               ` Suzuki K Poulose
  (?)
@ 2018-06-13 19:40                 ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-13 19:40 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: Matt Sealey, Rob Herring, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

On 13 June 2018 at 11:07, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
> Hi Matt,
>
> On 13/06/18 16:47, Matt Sealey wrote:
>>
>> Hi Suzuki,
>>
>>>> Why not use “unit”?
>>>>
>>>> I believe we had this discussion years ago about numbering serial ports
>>>> and sdhci (i.e. how do you know it’s UART0 or UART1 from just the
>>>> address?
>>>> Some SoC’s don’t address sequentially *or* in a forward direction) - I
>>>> believe it’s not exactly codified in ePAPR, not am I sure where it may
>>>> be
>>>> otherwise, but it exists.
>>>
>>>
>>> We have different situation here. We need to know *the port number* as
>>> understood by the hardware, so that we can enable *the specific* port for
>>> a given path.
>>
>>
>> For the purposes of abstraction, each port will have the property of
>> having
>> a node which is pointed to by other nodes, and in the case of a true ATB
>> endpoint, no other nodes behind it.
>>
>> It doesn't matter what the HW numbers it as as long as the driver can
>> derive
>> it from whatever you put in the DT. So a funnel (which is ~8 ports muxed
>> into
>> one output):
>>
>>     f1p0: port {
>>        unit = <0>;
>>        endpoint = <&f1out>;
>>     };
>>     f1p1: port {
>>        unit = <4>;
>>        endpoint = <&f1out>;
>>     };
>>     f1out: port {
>>        endpoint = <&etf1>;
>>     };
>>
>> "unit" here is specific to the driver's understanding of ports within it's
>
>
> I may be missing, but is "unit" something that already exists and used by
> DT bindings already ? Or is this something new that we are proposing ?
>
>> own cycle of the graph. For a replicator you can invert the logic - input
>> ports don't need a unit, but the two outputs are filtered in CoreSight not
>
>
> I would prefer to make the new property mandatory for all the ports to avoid
> a potential problem in the future.
>
> How do you represent a TMC-ETF which has one input and one output connection
> ?
> Also what happens if we ever get a component which has m-to-n connections ?
>
>> by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
>> you would want to describe all 8 possible units on each leg with the first
>> ID it would filter? Or just list tuples of filter IDs <id, first, last>
>
>
> I am failing to follow the ATB ID group description above. As per the TRM,
> e.g, replicator filters the "trace stream" based on the "trace ID", which I
> believe can be programmed via IDFILTER<n> register. So why would we need
> that
> to be part of the DT ?
>
>>
>> Who cares, really, as long as the driver knows what it means.
>>
>> You don't need to namespace every property.
>>
>>> As I mentioned above, we need the hardware numbers to enable the
>>> "specific" port.
>>
>>
>> Okay and how is this not able to be prescribed in a binding for
>> "arm,coresight-funnel"
>> that:
>>
>> "input ports are numbered from 0 to N where N is the maximum input port
>> number. This number is identified with the "unit" property, which directly
>> corresponds to the bit position in the funnel Ctrl_Reg register, and the
>> bit position multiplied by 3 for each 3-bit priority in the funnel
>> Priority_Ctrl_Reg, with N having a maximum of the defined register
>> bitfield
>> DEVID[PORTCOUNT], minus one, for that component"
>
>
> The description looks over complicated to me at least, even after having
> known
> bit of the programming interface of the components. I would prefer staying
> closer to the terms used in the TRM ("slave/master" interfaces) and make it
> easier for people to write the DT.
>
>>
>> Or a replicator:
>>
>> "output ports are numbered per the CoreSight ATB Replicator specification,
>> unit corresponding to the IDFILTERn register controlling ID filters for
>> that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
>> minus one"
>>
>> One could clarify it, even, with labels for readability ("label"
>> definitely
>> is a well defined if also completely arbitrary property).
>>
>> ..
>>
>>> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
>>> {
>>>           u32 functl;
>>>
>>>           CS_UNLOCK(drvdata->base);
>>>
>>>           functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>>>           functl &= ~FUNNEL_HOLDTIME_MASK;
>>>           functl |= FUNNEL_HOLDTIME;
>>>           functl |= (1 << port);
>>>           writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>>>           writel_relaxed(drvdata->priority, drvdata->base +
>>> FUNNEL_PRICTL);
>>>
>>>           CS_LOCK(drvdata->base);
>>> }
>>>
>>> No we don't need to parse it in both ways, up and down. Btw, the trace
>>> paths are not statically created. They are done at runtime, as configured
>>> by the user.
>>
>>
>> You do realize this isn't how the hardware works, correct?
>
>
> The "trace paths" mentioned above were indeed the software path, which
> was constructed at runtime. The graph connections are indeed a one time
> parsing at probe time and as you said they don't change. And by configuring,
> I mean selecting the "source" and the "sink".
>
>>
>> Trace paths are fixed, they may diverge with different configurations, but
>> the full CoreSight topology (all funnels, replicators and intermediary
>> Components) is entirely unchangeable.
>>
>> The DT should provide the information to provide a reference acyclic
>> directed
>> graph of the entire topology (or entirely reasonably programmable topology
>> where
>> at all possible) - if a user wants to trace from ETM_0 then they only
>> have particular paths to particular sinks, for instance ETM_0 and ETF_0
>> may be on their own path, so you cannot just "configure as a user"
>> a path from ETM_1 to ETF_0 since there isn't one.
>
>
>>
>> Walking said graphs with the knowledge that CoreSight specifically
>> disallows
>> loopbacks in ATB topology is basic computer science problem - literally a
>> matter of topological sorting. But let's build a graph once and traverse
>> it -
>> don't build the graph partially each time or try and build it to
>> cross-check
>> every time. The paths are wires in the design, lets not fake to the user
>> that there is any configurability in that or try and encode that in the
>> DT.
>
>
> Sorry for the confusion, as explained above, it is indeed a one time pass.
>
>>
>>> Coming back to your suggestion of "unit", what does it imply ?
>>
>>
>> Whatever the driver likes. For uart and mmc, it was just a spurious number
>> but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
>> in any other driver-specific manner. The number you put in is up to you,
>> but the valid numbers would be in the binding for that particular device.
>>
>>> Its too generic a term for something as concrete as a port number.
>>
>>
>> Is it?
>>
>> Why would you need a whole other property type to encode a u32 that
>> describes an arbitrary number specific to that hardware device?
>
>
> So, if the suggestion is to use an existing property "unit", I am fine
> with it, if people agree to it.

If we're going to have something sharply different than ACPI I prefer
Rob's idea.

Mathieu

>
>
> Thanks for the comments.
>
> Cheers,
> Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 19:40                 ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-13 19:40 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: Matt Sealey, Rob Herring, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

On 13 June 2018 at 11:07, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
> Hi Matt,
>
> On 13/06/18 16:47, Matt Sealey wrote:
>>
>> Hi Suzuki,
>>
>>>> Why not use “unit”?
>>>>
>>>> I believe we had this discussion years ago about numbering serial ports
>>>> and sdhci (i.e. how do you know it’s UART0 or UART1 from just the
>>>> address?
>>>> Some SoC’s don’t address sequentially *or* in a forward direction) - I
>>>> believe it’s not exactly codified in ePAPR, not am I sure where it may
>>>> be
>>>> otherwise, but it exists.
>>>
>>>
>>> We have different situation here. We need to know *the port number* as
>>> understood by the hardware, so that we can enable *the specific* port for
>>> a given path.
>>
>>
>> For the purposes of abstraction, each port will have the property of
>> having
>> a node which is pointed to by other nodes, and in the case of a true ATB
>> endpoint, no other nodes behind it.
>>
>> It doesn't matter what the HW numbers it as as long as the driver can
>> derive
>> it from whatever you put in the DT. So a funnel (which is ~8 ports muxed
>> into
>> one output):
>>
>>     f1p0: port {
>>        unit = <0>;
>>        endpoint = <&f1out>;
>>     };
>>     f1p1: port {
>>        unit = <4>;
>>        endpoint = <&f1out>;
>>     };
>>     f1out: port {
>>        endpoint = <&etf1>;
>>     };
>>
>> "unit" here is specific to the driver's understanding of ports within it's
>
>
> I may be missing, but is "unit" something that already exists and used by
> DT bindings already ? Or is this something new that we are proposing ?
>
>> own cycle of the graph. For a replicator you can invert the logic - input
>> ports don't need a unit, but the two outputs are filtered in CoreSight not
>
>
> I would prefer to make the new property mandatory for all the ports to avoid
> a potential problem in the future.
>
> How do you represent a TMC-ETF which has one input and one output connection
> ?
> Also what happens if we ever get a component which has m-to-n connections ?
>
>> by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
>> you would want to describe all 8 possible units on each leg with the first
>> ID it would filter? Or just list tuples of filter IDs <id, first, last>
>
>
> I am failing to follow the ATB ID group description above. As per the TRM,
> e.g, replicator filters the "trace stream" based on the "trace ID", which I
> believe can be programmed via IDFILTER<n> register. So why would we need
> that
> to be part of the DT ?
>
>>
>> Who cares, really, as long as the driver knows what it means.
>>
>> You don't need to namespace every property.
>>
>>> As I mentioned above, we need the hardware numbers to enable the
>>> "specific" port.
>>
>>
>> Okay and how is this not able to be prescribed in a binding for
>> "arm,coresight-funnel"
>> that:
>>
>> "input ports are numbered from 0 to N where N is the maximum input port
>> number. This number is identified with the "unit" property, which directly
>> corresponds to the bit position in the funnel Ctrl_Reg register, and the
>> bit position multiplied by 3 for each 3-bit priority in the funnel
>> Priority_Ctrl_Reg, with N having a maximum of the defined register
>> bitfield
>> DEVID[PORTCOUNT], minus one, for that component"
>
>
> The description looks over complicated to me at least, even after having
> known
> bit of the programming interface of the components. I would prefer staying
> closer to the terms used in the TRM ("slave/master" interfaces) and make it
> easier for people to write the DT.
>
>>
>> Or a replicator:
>>
>> "output ports are numbered per the CoreSight ATB Replicator specification,
>> unit corresponding to the IDFILTERn register controlling ID filters for
>> that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
>> minus one"
>>
>> One could clarify it, even, with labels for readability ("label"
>> definitely
>> is a well defined if also completely arbitrary property).
>>
>> ..
>>
>>> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
>>> {
>>>           u32 functl;
>>>
>>>           CS_UNLOCK(drvdata->base);
>>>
>>>           functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>>>           functl &= ~FUNNEL_HOLDTIME_MASK;
>>>           functl |= FUNNEL_HOLDTIME;
>>>           functl |= (1 << port);
>>>           writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>>>           writel_relaxed(drvdata->priority, drvdata->base +
>>> FUNNEL_PRICTL);
>>>
>>>           CS_LOCK(drvdata->base);
>>> }
>>>
>>> No we don't need to parse it in both ways, up and down. Btw, the trace
>>> paths are not statically created. They are done at runtime, as configured
>>> by the user.
>>
>>
>> You do realize this isn't how the hardware works, correct?
>
>
> The "trace paths" mentioned above were indeed the software path, which
> was constructed at runtime. The graph connections are indeed a one time
> parsing at probe time and as you said they don't change. And by configuring,
> I mean selecting the "source" and the "sink".
>
>>
>> Trace paths are fixed, they may diverge with different configurations, but
>> the full CoreSight topology (all funnels, replicators and intermediary
>> Components) is entirely unchangeable.
>>
>> The DT should provide the information to provide a reference acyclic
>> directed
>> graph of the entire topology (or entirely reasonably programmable topology
>> where
>> at all possible) - if a user wants to trace from ETM_0 then they only
>> have particular paths to particular sinks, for instance ETM_0 and ETF_0
>> may be on their own path, so you cannot just "configure as a user"
>> a path from ETM_1 to ETF_0 since there isn't one.
>
>
>>
>> Walking said graphs with the knowledge that CoreSight specifically
>> disallows
>> loopbacks in ATB topology is basic computer science problem - literally a
>> matter of topological sorting. But let's build a graph once and traverse
>> it -
>> don't build the graph partially each time or try and build it to
>> cross-check
>> every time. The paths are wires in the design, lets not fake to the user
>> that there is any configurability in that or try and encode that in the
>> DT.
>
>
> Sorry for the confusion, as explained above, it is indeed a one time pass.
>
>>
>>> Coming back to your suggestion of "unit", what does it imply ?
>>
>>
>> Whatever the driver likes. For uart and mmc, it was just a spurious number
>> but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
>> in any other driver-specific manner. The number you put in is up to you,
>> but the valid numbers would be in the binding for that particular device.
>>
>>> Its too generic a term for something as concrete as a port number.
>>
>>
>> Is it?
>>
>> Why would you need a whole other property type to encode a u32 that
>> describes an arbitrary number specific to that hardware device?
>
>
> So, if the suggestion is to use an existing property "unit", I am fine
> with it, if people agree to it.

If we're going to have something sharply different than ACPI I prefer
Rob's idea.

Mathieu

>
>
> Thanks for the comments.
>
> Cheers,
> Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 19:40                 ` Mathieu Poirier
  0 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-06-13 19:40 UTC (permalink / raw)
  To: linux-arm-kernel

On 13 June 2018 at 11:07, Suzuki K Poulose <Suzuki.Poulose@arm.com> wrote:
> Hi Matt,
>
> On 13/06/18 16:47, Matt Sealey wrote:
>>
>> Hi Suzuki,
>>
>>>> Why not use ?unit??
>>>>
>>>> I believe we had this discussion years ago about numbering serial ports
>>>> and sdhci (i.e. how do you know it?s UART0 or UART1 from just the
>>>> address?
>>>> Some SoC?s don?t address sequentially *or* in a forward direction) - I
>>>> believe it?s not exactly codified in ePAPR, not am I sure where it may
>>>> be
>>>> otherwise, but it exists.
>>>
>>>
>>> We have different situation here. We need to know *the port number* as
>>> understood by the hardware, so that we can enable *the specific* port for
>>> a given path.
>>
>>
>> For the purposes of abstraction, each port will have the property of
>> having
>> a node which is pointed to by other nodes, and in the case of a true ATB
>> endpoint, no other nodes behind it.
>>
>> It doesn't matter what the HW numbers it as as long as the driver can
>> derive
>> it from whatever you put in the DT. So a funnel (which is ~8 ports muxed
>> into
>> one output):
>>
>>     f1p0: port {
>>        unit = <0>;
>>        endpoint = <&f1out>;
>>     };
>>     f1p1: port {
>>        unit = <4>;
>>        endpoint = <&f1out>;
>>     };
>>     f1out: port {
>>        endpoint = <&etf1>;
>>     };
>>
>> "unit" here is specific to the driver's understanding of ports within it's
>
>
> I may be missing, but is "unit" something that already exists and used by
> DT bindings already ? Or is this something new that we are proposing ?
>
>> own cycle of the graph. For a replicator you can invert the logic - input
>> ports don't need a unit, but the two outputs are filtered in CoreSight not
>
>
> I would prefer to make the new property mandatory for all the ports to avoid
> a potential problem in the future.
>
> How do you represent a TMC-ETF which has one input and one output connection
> ?
> Also what happens if we ever get a component which has m-to-n connections ?
>
>> by leg but by transiting ATB ID in groups of 16 IDs. In that case maybe
>> you would want to describe all 8 possible units on each leg with the first
>> ID it would filter? Or just list tuples of filter IDs <id, first, last>
>
>
> I am failing to follow the ATB ID group description above. As per the TRM,
> e.g, replicator filters the "trace stream" based on the "trace ID", which I
> believe can be programmed via IDFILTER<n> register. So why would we need
> that
> to be part of the DT ?
>
>>
>> Who cares, really, as long as the driver knows what it means.
>>
>> You don't need to namespace every property.
>>
>>> As I mentioned above, we need the hardware numbers to enable the
>>> "specific" port.
>>
>>
>> Okay and how is this not able to be prescribed in a binding for
>> "arm,coresight-funnel"
>> that:
>>
>> "input ports are numbered from 0 to N where N is the maximum input port
>> number. This number is identified with the "unit" property, which directly
>> corresponds to the bit position in the funnel Ctrl_Reg register, and the
>> bit position multiplied by 3 for each 3-bit priority in the funnel
>> Priority_Ctrl_Reg, with N having a maximum of the defined register
>> bitfield
>> DEVID[PORTCOUNT], minus one, for that component"
>
>
> The description looks over complicated to me at least, even after having
> known
> bit of the programming interface of the components. I would prefer staying
> closer to the terms used in the TRM ("slave/master" interfaces) and make it
> easier for people to write the DT.
>
>>
>> Or a replicator:
>>
>> "output ports are numbered per the CoreSight ATB Replicator specification,
>> unit corresponding to the IDFILTERn register controlling ID filters for
>> that leg, with a maximum of the defined register bitfield DEVID[PORTNUM],
>> minus one"
>>
>> One could clarify it, even, with labels for readability ("label"
>> definitely
>> is a well defined if also completely arbitrary property).
>>
>> ..
>>
>>> static void funnel_enable_hw(struct funnel_drvdata *drvdata, int port)
>>> {
>>>           u32 functl;
>>>
>>>           CS_UNLOCK(drvdata->base);
>>>
>>>           functl = readl_relaxed(drvdata->base + FUNNEL_FUNCTL);
>>>           functl &= ~FUNNEL_HOLDTIME_MASK;
>>>           functl |= FUNNEL_HOLDTIME;
>>>           functl |= (1 << port);
>>>           writel_relaxed(functl, drvdata->base + FUNNEL_FUNCTL);
>>>           writel_relaxed(drvdata->priority, drvdata->base +
>>> FUNNEL_PRICTL);
>>>
>>>           CS_LOCK(drvdata->base);
>>> }
>>>
>>> No we don't need to parse it in both ways, up and down. Btw, the trace
>>> paths are not statically created. They are done at runtime, as configured
>>> by the user.
>>
>>
>> You do realize this isn't how the hardware works, correct?
>
>
> The "trace paths" mentioned above were indeed the software path, which
> was constructed at runtime. The graph connections are indeed a one time
> parsing at probe time and as you said they don't change. And by configuring,
> I mean selecting the "source" and the "sink".
>
>>
>> Trace paths are fixed, they may diverge with different configurations, but
>> the full CoreSight topology (all funnels, replicators and intermediary
>> Components) is entirely unchangeable.
>>
>> The DT should provide the information to provide a reference acyclic
>> directed
>> graph of the entire topology (or entirely reasonably programmable topology
>> where
>> at all possible) - if a user wants to trace from ETM_0 then they only
>> have particular paths to particular sinks, for instance ETM_0 and ETF_0
>> may be on their own path, so you cannot just "configure as a user"
>> a path from ETM_1 to ETF_0 since there isn't one.
>
>
>>
>> Walking said graphs with the knowledge that CoreSight specifically
>> disallows
>> loopbacks in ATB topology is basic computer science problem - literally a
>> matter of topological sorting. But let's build a graph once and traverse
>> it -
>> don't build the graph partially each time or try and build it to
>> cross-check
>> every time. The paths are wires in the design, lets not fake to the user
>> that there is any configurability in that or try and encode that in the
>> DT.
>
>
> Sorry for the confusion, as explained above, it is indeed a one time pass.
>
>>
>>> Coming back to your suggestion of "unit", what does it imply ?
>>
>>
>> Whatever the driver likes. For uart and mmc, it was just a spurious number
>> but it could be applied as the end of, say, ttyS<N> or mmcblk<N>p3 or used
>> in any other driver-specific manner. The number you put in is up to you,
>> but the valid numbers would be in the binding for that particular device.
>>
>>> Its too generic a term for something as concrete as a port number.
>>
>>
>> Is it?
>>
>> Why would you need a whole other property type to encode a u32 that
>> describes an arbitrary number specific to that hardware device?
>
>
> So, if the suggestion is to use an existing property "unit", I am fine
> with it, if people agree to it.

If we're going to have something sharply different than ACPI I prefer
Rob's idea.

Mathieu

>
>
> Thanks for the comments.
>
> Cheers,
> Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* RE: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-13 19:40                 ` Mathieu Poirier
  (?)
@ 2018-06-13 21:07                   ` Matt Sealey
  -1 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 21:07 UTC (permalink / raw)
  To: Mathieu Poirier, Suzuki Poulose
  Cc: Rob Herring, linux-arm-kernel, Sudeep Holla, Mark Rutland,
	frowand.list, Charles Garcia-Tobin, John Horley, mike.leach,
	coresight, linux-kernel, devicetree



> -----Original Message-----
> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>
> > So, if the suggestion is to use an existing property "unit", I am fine
> > with it, if people agree to it.
>
> If we're going to have something sharply different than ACPI I prefer
> Rob's idea.

What are you trying to say about being sharply different than ACPI?

Ta,
Matt


IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* RE: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 21:07                   ` Matt Sealey
  0 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 21:07 UTC (permalink / raw)
  To: Mathieu Poirier, Suzuki Poulose
  Cc: Rob Herring, linux-arm-kernel, Sudeep Holla, Mark Rutland,
	frowand.list, Charles Garcia-Tobin, John Horley, mike.leach,
	coresight, linux-kernel, devicetree



> -----Original Message-----
> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>
> > So, if the suggestion is to use an existing property "unit", I am fine
> > with it, if people agree to it.
>
> If we're going to have something sharply different than ACPI I prefer
> Rob's idea.

What are you trying to say about being sharply different than ACPI?

Ta,
Matt


IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-13 21:07                   ` Matt Sealey
  0 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-13 21:07 UTC (permalink / raw)
  To: linux-arm-kernel



> -----Original Message-----
> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>
> > So, if the suggestion is to use an existing property "unit", I am fine
> > with it, if people agree to it.
>
> If we're going to have something sharply different than ACPI I prefer
> Rob's idea.

What are you trying to say about being sharply different than ACPI?

Ta,
Matt


IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-13 21:07                   ` Matt Sealey
  (?)
@ 2018-06-14  8:53                     ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-14  8:53 UTC (permalink / raw)
  To: Matt Sealey, Mathieu Poirier
  Cc: Rob Herring, linux-arm-kernel, Sudeep Holla, Mark Rutland,
	frowand.list, Charles Garcia-Tobin, John Horley, mike.leach,
	coresight, linux-kernel, devicetree

On 13/06/18 22:07, Matt Sealey wrote:
> 
> 
>> -----Original Message-----
>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>
>>> So, if the suggestion is to use an existing property "unit", I am fine
>>> with it, if people agree to it.
>>
>> If we're going to have something sharply different than ACPI I prefer
>> Rob's idea.

No, the above comment is about using "unit" ( if it is a standard property
for specifying something specific to hardware) instead of "coresight,hwid".
I would prefer to stick to the DT graph bindings, because :

1) The connections are bi-directional => Well, not necessarily bi-directional
in terms of the data flow. But the connection information is critical. i.e,
we need information about both the end-points of a connection, which the DT
graph bindings solves.

All we are missing is a way for specifying the "hardware port" number and the
direction of flow. I don't see why do we need to create something new just for
these two properties for something that exists today and works reasonably well
for the usecase.

> 
> What are you trying to say about being sharply different than ACPI?

The proposed Coresight ACPI draft bindings are based on the ACPI Graph bindings
(just like the DT graph bindings and is compatible with it, in terms of the APIs.
i.e, fwnode_graph_* operations work for both ACPI and DT  alike).

So, what Mathieu, in turn means is, if we depart from the DT Graph bindings, which
I personally don't see any benefit in.

Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-14  8:53                     ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-14  8:53 UTC (permalink / raw)
  To: Matt Sealey, Mathieu Poirier
  Cc: Rob Herring, linux-arm-kernel, Sudeep Holla, Mark Rutland,
	frowand.list, Charles Garcia-Tobin, John Horley, mike.leach,
	coresight, linux-kernel, devicetree

On 13/06/18 22:07, Matt Sealey wrote:
> 
> 
>> -----Original Message-----
>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>
>>> So, if the suggestion is to use an existing property "unit", I am fine
>>> with it, if people agree to it.
>>
>> If we're going to have something sharply different than ACPI I prefer
>> Rob's idea.

No, the above comment is about using "unit" ( if it is a standard property
for specifying something specific to hardware) instead of "coresight,hwid".
I would prefer to stick to the DT graph bindings, because :

1) The connections are bi-directional => Well, not necessarily bi-directional
in terms of the data flow. But the connection information is critical. i.e,
we need information about both the end-points of a connection, which the DT
graph bindings solves.

All we are missing is a way for specifying the "hardware port" number and the
direction of flow. I don't see why do we need to create something new just for
these two properties for something that exists today and works reasonably well
for the usecase.

> 
> What are you trying to say about being sharply different than ACPI?

The proposed Coresight ACPI draft bindings are based on the ACPI Graph bindings
(just like the DT graph bindings and is compatible with it, in terms of the APIs.
i.e, fwnode_graph_* operations work for both ACPI and DT  alike).

So, what Mathieu, in turn means is, if we depart from the DT Graph bindings, which
I personally don't see any benefit in.

Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-14  8:53                     ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-14  8:53 UTC (permalink / raw)
  To: linux-arm-kernel

On 13/06/18 22:07, Matt Sealey wrote:
> 
> 
>> -----Original Message-----
>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>
>>> So, if the suggestion is to use an existing property "unit", I am fine
>>> with it, if people agree to it.
>>
>> If we're going to have something sharply different than ACPI I prefer
>> Rob's idea.

No, the above comment is about using "unit" ( if it is a standard property
for specifying something specific to hardware) instead of "coresight,hwid".
I would prefer to stick to the DT graph bindings, because :

1) The connections are bi-directional => Well, not necessarily bi-directional
in terms of the data flow. But the connection information is critical. i.e,
we need information about both the end-points of a connection, which the DT
graph bindings solves.

All we are missing is a way for specifying the "hardware port" number and the
direction of flow. I don't see why do we need to create something new just for
these two properties for something that exists today and works reasonably well
for the usecase.

> 
> What are you trying to say about being sharply different than ACPI?

The proposed Coresight ACPI draft bindings are based on the ACPI Graph bindings
(just like the DT graph bindings and is compatible with it, in terms of the APIs.
i.e, fwnode_graph_* operations work for both ACPI and DT  alike).

So, what Mathieu, in turn means is, if we depart from the DT Graph bindings, which
I personally don't see any benefit in.

Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-14  8:53                     ` Suzuki K Poulose
  (?)
@ 2018-06-14 13:59                       ` Rob Herring
  -1 siblings, 0 replies; 77+ messages in thread
From: Rob Herring @ 2018-06-14 13:59 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: Matt Sealey, Mathieu Poirier, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
<Suzuki.Poulose@arm.com> wrote:
> On 13/06/18 22:07, Matt Sealey wrote:
>>
>>
>>
>>> -----Original Message-----
>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>
>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>> with it, if people agree to it.
>>>
>>>
>>> If we're going to have something sharply different than ACPI I prefer
>>> Rob's idea.
>
>
> No, the above comment is about using "unit" ( if it is a standard property
> for specifying something specific to hardware) instead of "coresight,hwid".
> I would prefer to stick to the DT graph bindings, because :

"unit" is not a standard property and I don't like it either.

>
> 1) The connections are bi-directional => Well, not necessarily
> bi-directional
> in terms of the data flow. But the connection information is critical. i.e,
> we need information about both the end-points of a connection, which the DT
> graph bindings solves.
>
> All we are missing is a way for specifying the "hardware port" number and
> the
> direction of flow. I don't see why do we need to create something new just
> for
> these two properties for something that exists today and works reasonably
> well
> for the usecase.

If you have "in-ports" and "out-ports" nodes, then that gives you
direction and you can use reg for the "hardware port".

in-ports {
  port@0 {
    reg = <0>;
    endpoint {...};
  };
  port@1 {
    reg = <1>;
    endpoint {...};
  };
};
out-ports {
  port@0 {
    reg = <0>;
    endpoint {...};
  };
};

I'll need to check, but dtc may need an update to not warn about this.

>
>>
>> What are you trying to say about being sharply different than ACPI?
>
>
> The proposed Coresight ACPI draft bindings are based on the ACPI Graph
> bindings
> (just like the DT graph bindings and is compatible with it, in terms of the
> APIs.
> i.e, fwnode_graph_* operations work for both ACPI and DT  alike).
>
> So, what Mathieu, in turn means is, if we depart from the DT Graph bindings,
> which
> I personally don't see any benefit in.

If DT bindings can be reused for ACPI, that's fine, but don't expect
any DT bindings to be accepted simply because they match ACPI
bindings.

Rob

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-14 13:59                       ` Rob Herring
  0 siblings, 0 replies; 77+ messages in thread
From: Rob Herring @ 2018-06-14 13:59 UTC (permalink / raw)
  To: Suzuki K Poulose
  Cc: Matt Sealey, Mathieu Poirier, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
<Suzuki.Poulose@arm.com> wrote:
> On 13/06/18 22:07, Matt Sealey wrote:
>>
>>
>>
>>> -----Original Message-----
>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>
>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>> with it, if people agree to it.
>>>
>>>
>>> If we're going to have something sharply different than ACPI I prefer
>>> Rob's idea.
>
>
> No, the above comment is about using "unit" ( if it is a standard property
> for specifying something specific to hardware) instead of "coresight,hwid".
> I would prefer to stick to the DT graph bindings, because :

"unit" is not a standard property and I don't like it either.

>
> 1) The connections are bi-directional => Well, not necessarily
> bi-directional
> in terms of the data flow. But the connection information is critical. i.e,
> we need information about both the end-points of a connection, which the DT
> graph bindings solves.
>
> All we are missing is a way for specifying the "hardware port" number and
> the
> direction of flow. I don't see why do we need to create something new just
> for
> these two properties for something that exists today and works reasonably
> well
> for the usecase.

If you have "in-ports" and "out-ports" nodes, then that gives you
direction and you can use reg for the "hardware port".

in-ports {
  port@0 {
    reg = <0>;
    endpoint {...};
  };
  port@1 {
    reg = <1>;
    endpoint {...};
  };
};
out-ports {
  port@0 {
    reg = <0>;
    endpoint {...};
  };
};

I'll need to check, but dtc may need an update to not warn about this.

>
>>
>> What are you trying to say about being sharply different than ACPI?
>
>
> The proposed Coresight ACPI draft bindings are based on the ACPI Graph
> bindings
> (just like the DT graph bindings and is compatible with it, in terms of the
> APIs.
> i.e, fwnode_graph_* operations work for both ACPI and DT  alike).
>
> So, what Mathieu, in turn means is, if we depart from the DT Graph bindings,
> which
> I personally don't see any benefit in.

If DT bindings can be reused for ACPI, that's fine, but don't expect
any DT bindings to be accepted simply because they match ACPI
bindings.

Rob

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-14 13:59                       ` Rob Herring
  0 siblings, 0 replies; 77+ messages in thread
From: Rob Herring @ 2018-06-14 13:59 UTC (permalink / raw)
  To: linux-arm-kernel

On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
<Suzuki.Poulose@arm.com> wrote:
> On 13/06/18 22:07, Matt Sealey wrote:
>>
>>
>>
>>> -----Original Message-----
>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>
>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>> with it, if people agree to it.
>>>
>>>
>>> If we're going to have something sharply different than ACPI I prefer
>>> Rob's idea.
>
>
> No, the above comment is about using "unit" ( if it is a standard property
> for specifying something specific to hardware) instead of "coresight,hwid".
> I would prefer to stick to the DT graph bindings, because :

"unit" is not a standard property and I don't like it either.

>
> 1) The connections are bi-directional => Well, not necessarily
> bi-directional
> in terms of the data flow. But the connection information is critical. i.e,
> we need information about both the end-points of a connection, which the DT
> graph bindings solves.
>
> All we are missing is a way for specifying the "hardware port" number and
> the
> direction of flow. I don't see why do we need to create something new just
> for
> these two properties for something that exists today and works reasonably
> well
> for the usecase.

If you have "in-ports" and "out-ports" nodes, then that gives you
direction and you can use reg for the "hardware port".

in-ports {
  port at 0 {
    reg = <0>;
    endpoint {...};
  };
  port at 1 {
    reg = <1>;
    endpoint {...};
  };
};
out-ports {
  port at 0 {
    reg = <0>;
    endpoint {...};
  };
};

I'll need to check, but dtc may need an update to not warn about this.

>
>>
>> What are you trying to say about being sharply different than ACPI?
>
>
> The proposed Coresight ACPI draft bindings are based on the ACPI Graph
> bindings
> (just like the DT graph bindings and is compatible with it, in terms of the
> APIs.
> i.e, fwnode_graph_* operations work for both ACPI and DT  alike).
>
> So, what Mathieu, in turn means is, if we depart from the DT Graph bindings,
> which
> I personally don't see any benefit in.

If DT bindings can be reused for ACPI, that's fine, but don't expect
any DT bindings to be accepted simply because they match ACPI
bindings.

Rob

^ permalink raw reply	[flat|nested] 77+ messages in thread

* RE: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-14 13:59                       ` Rob Herring
  (?)
@ 2018-06-14 15:04                         ` Matt Sealey
  -1 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-14 15:04 UTC (permalink / raw)
  To: Rob Herring, Suzuki Poulose
  Cc: Mathieu Poirier, linux-arm-kernel, Sudeep Holla, Mark Rutland,
	frowand.list, Charles Garcia-Tobin, John Horley, mike.leach,
	coresight, linux-kernel, devicetree

Hi Rob,

To take this in a somewhat different direction...

> > No, the above comment is about using "unit" ( if it is a standard
> > property for specifying something specific to hardware) instead of
> > "coresight,hwid". I would prefer to stick to the DT graph bindings,
> > because :
>
> "unit" is not a standard property and I don't like it either.

Fair enough.

> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
>
> in-ports {
>   port@0 {
>     reg = <0>;
>     endpoint {...};
>   };
>   port@1 {
>     reg = <1>;
>     endpoint {...};
>   };
> };
> out-ports {
>   port@0 {
>     reg = <0>;
>     endpoint {...};
>   };
> };
>
> I'll need to check, but dtc may need an update to not warn about this.

If the requirement that unit-address and the low #address-cells of reg
now being forced by a validation tool is screwing us over here, we can't
really change the tool; that's a IEEE 1275-1994 requirement we'd be
hacking around.

Here's a thought - why don't we define the ports in each component in a
separate graph? Describing the ATB topology as a bus with a graph structure
and then having the components simply reference the port nodes would make
it much easier to design.

Part of the problem is trying to describe an ATB bus via a component on
an APB bus. You lose all the niceties of describing a bus with bus
subcomponents. Lets take the ATB bus outside.. by describing the ingress
and egress of the component you have no idea where in the graph you are
at the point of entry (you could start parsing at a funnel, which means
travelling around looking for other units that match other compatibles).

If the CoreSight subsystem could have a graph pre-made of the full
topology, then the components can point to how they wrap parts of
that topology. You can also do away with ridiculous non-programmable
funnels and replicator nodes, since the trace graph would encapsulate
that information without having to instantiate a stub driver for it.

That doesn't solve 'unit' or 'unit-address' or 'reg' or anything but
it would keep us in graph bindings and abstract the ATB topology from
the components. Other fun stuff; describing bridge components and bus
widths within the graph could give abilities to describe bandwidths
over each trace path.

In any case, what happens when you have to decide what your funnel
port priorities are, you'll have to define a new property for that,
and it won't be 'reg'.

Trying not to add anything to the graph bindings is one thing but
trying to shoehorn it in either by doing that or inventing wholly
device-specific properties are just as bad.

Perhaps we can use the path@unit-address:arguments <-- parameters here to
add extra information about the port. 'my-args' would pull it out in Forth,
I don't know how FDT code deals with it (but there should be something,
since we use it for console definition in /chosen). They're entirely
specific to the node in question, but not used in path matching.

Why can't we decide on a graph-binding update that allows specifying
something simple as a demultiplexer output in a way the driver can
understand and map to the hardware?

> If DT bindings can be reused for ACPI, that's fine

However in my opinion not the preferred way to do it..

> any DT bindings to be accepted simply because they match ACPI
> bindings.

I'm sure ACPI has capability of a much classier way of describing
things, but I have some fear that it's just OF bindings stuffed in
a _DSD.. DT and ACPI have the responsibility of shouldering the
burden of describing hardware. Any attempts to try and make some
commonality to promote brevity of Linux code is totally out of scope..

You can always abstract whatever definition into whatever the Linux
drivers need at the time. That's kind of the point. Locking in to
'how it's currently coded' is stifling when realizing the first
attempt didn't actually adequately do what it was intended.

Ta,
Matt
IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* RE: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-14 15:04                         ` Matt Sealey
  0 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-14 15:04 UTC (permalink / raw)
  To: Rob Herring, Suzuki Poulose
  Cc: Mathieu Poirier, linux-arm-kernel, Sudeep Holla, Mark Rutland,
	frowand.list, Charles Garcia-Tobin, John Horley, mike.leach,
	coresight, linux-kernel, devicetree

Hi Rob,

To take this in a somewhat different direction...

> > No, the above comment is about using "unit" ( if it is a standard
> > property for specifying something specific to hardware) instead of
> > "coresight,hwid". I would prefer to stick to the DT graph bindings,
> > because :
>
> "unit" is not a standard property and I don't like it either.

Fair enough.

> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
>
> in-ports {
>   port@0 {
>     reg = <0>;
>     endpoint {...};
>   };
>   port@1 {
>     reg = <1>;
>     endpoint {...};
>   };
> };
> out-ports {
>   port@0 {
>     reg = <0>;
>     endpoint {...};
>   };
> };
>
> I'll need to check, but dtc may need an update to not warn about this.

If the requirement that unit-address and the low #address-cells of reg
now being forced by a validation tool is screwing us over here, we can't
really change the tool; that's a IEEE 1275-1994 requirement we'd be
hacking around.

Here's a thought - why don't we define the ports in each component in a
separate graph? Describing the ATB topology as a bus with a graph structure
and then having the components simply reference the port nodes would make
it much easier to design.

Part of the problem is trying to describe an ATB bus via a component on
an APB bus. You lose all the niceties of describing a bus with bus
subcomponents. Lets take the ATB bus outside.. by describing the ingress
and egress of the component you have no idea where in the graph you are
at the point of entry (you could start parsing at a funnel, which means
travelling around looking for other units that match other compatibles).

If the CoreSight subsystem could have a graph pre-made of the full
topology, then the components can point to how they wrap parts of
that topology. You can also do away with ridiculous non-programmable
funnels and replicator nodes, since the trace graph would encapsulate
that information without having to instantiate a stub driver for it.

That doesn't solve 'unit' or 'unit-address' or 'reg' or anything but
it would keep us in graph bindings and abstract the ATB topology from
the components. Other fun stuff; describing bridge components and bus
widths within the graph could give abilities to describe bandwidths
over each trace path.

In any case, what happens when you have to decide what your funnel
port priorities are, you'll have to define a new property for that,
and it won't be 'reg'.

Trying not to add anything to the graph bindings is one thing but
trying to shoehorn it in either by doing that or inventing wholly
device-specific properties are just as bad.

Perhaps we can use the path@unit-address:arguments <-- parameters here to
add extra information about the port. 'my-args' would pull it out in Forth,
I don't know how FDT code deals with it (but there should be something,
since we use it for console definition in /chosen). They're entirely
specific to the node in question, but not used in path matching.

Why can't we decide on a graph-binding update that allows specifying
something simple as a demultiplexer output in a way the driver can
understand and map to the hardware?

> If DT bindings can be reused for ACPI, that's fine

However in my opinion not the preferred way to do it..

> any DT bindings to be accepted simply because they match ACPI
> bindings.

I'm sure ACPI has capability of a much classier way of describing
things, but I have some fear that it's just OF bindings stuffed in
a _DSD.. DT and ACPI have the responsibility of shouldering the
burden of describing hardware. Any attempts to try and make some
commonality to promote brevity of Linux code is totally out of scope..

You can always abstract whatever definition into whatever the Linux
drivers need at the time. That's kind of the point. Locking in to
'how it's currently coded' is stifling when realizing the first
attempt didn't actually adequately do what it was intended.

Ta,
Matt
IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-14 15:04                         ` Matt Sealey
  0 siblings, 0 replies; 77+ messages in thread
From: Matt Sealey @ 2018-06-14 15:04 UTC (permalink / raw)
  To: linux-arm-kernel

Hi Rob,

To take this in a somewhat different direction...

> > No, the above comment is about using "unit" ( if it is a standard
> > property for specifying something specific to hardware) instead of
> > "coresight,hwid". I would prefer to stick to the DT graph bindings,
> > because :
>
> "unit" is not a standard property and I don't like it either.

Fair enough.

> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
>
> in-ports {
>   port at 0 {
>     reg = <0>;
>     endpoint {...};
>   };
>   port at 1 {
>     reg = <1>;
>     endpoint {...};
>   };
> };
> out-ports {
>   port at 0 {
>     reg = <0>;
>     endpoint {...};
>   };
> };
>
> I'll need to check, but dtc may need an update to not warn about this.

If the requirement that unit-address and the low #address-cells of reg
now being forced by a validation tool is screwing us over here, we can't
really change the tool; that's a IEEE 1275-1994 requirement we'd be
hacking around.

Here's a thought - why don't we define the ports in each component in a
separate graph? Describing the ATB topology as a bus with a graph structure
and then having the components simply reference the port nodes would make
it much easier to design.

Part of the problem is trying to describe an ATB bus via a component on
an APB bus. You lose all the niceties of describing a bus with bus
subcomponents. Lets take the ATB bus outside.. by describing the ingress
and egress of the component you have no idea where in the graph you are
at the point of entry (you could start parsing at a funnel, which means
travelling around looking for other units that match other compatibles).

If the CoreSight subsystem could have a graph pre-made of the full
topology, then the components can point to how they wrap parts of
that topology. You can also do away with ridiculous non-programmable
funnels and replicator nodes, since the trace graph would encapsulate
that information without having to instantiate a stub driver for it.

That doesn't solve 'unit' or 'unit-address' or 'reg' or anything but
it would keep us in graph bindings and abstract the ATB topology from
the components. Other fun stuff; describing bridge components and bus
widths within the graph could give abilities to describe bandwidths
over each trace path.

In any case, what happens when you have to decide what your funnel
port priorities are, you'll have to define a new property for that,
and it won't be 'reg'.

Trying not to add anything to the graph bindings is one thing but
trying to shoehorn it in either by doing that or inventing wholly
device-specific properties are just as bad.

Perhaps we can use the path at unit-address:arguments <-- parameters here to
add extra information about the port. 'my-args' would pull it out in Forth,
I don't know how FDT code deals with it (but there should be something,
since we use it for console definition in /chosen). They're entirely
specific to the node in question, but not used in path matching.

Why can't we decide on a graph-binding update that allows specifying
something simple as a demultiplexer output in a way the driver can
understand and map to the hardware?

> If DT bindings can be reused for ACPI, that's fine

However in my opinion not the preferred way to do it..

> any DT bindings to be accepted simply because they match ACPI
> bindings.

I'm sure ACPI has capability of a much classier way of describing
things, but I have some fear that it's just OF bindings stuffed in
a _DSD.. DT and ACPI have the responsibility of shouldering the
burden of describing hardware. Any attempts to try and make some
commonality to promote brevity of Linux code is totally out of scope..

You can always abstract whatever definition into whatever the Linux
drivers need at the time. That's kind of the point. Locking in to
'how it's currently coded' is stifling when realizing the first
attempt didn't actually adequately do what it was intended.

Ta,
Matt
IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you.

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-14 13:59                       ` Rob Herring
  (?)
@ 2018-06-15  9:58                         ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-15  9:58 UTC (permalink / raw)
  To: Rob Herring
  Cc: Matt Sealey, Mathieu Poirier, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

On 14/06/18 14:59, Rob Herring wrote:
> On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
> <Suzuki.Poulose@arm.com> wrote:
>> On 13/06/18 22:07, Matt Sealey wrote:
>>>
>>>
>>>
>>>> -----Original Message-----
>>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>>
>>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>>> with it, if people agree to it.
>>>>
>>>>
>>>> If we're going to have something sharply different than ACPI I prefer
>>>> Rob's idea.
>>
>>
>> No, the above comment is about using "unit" ( if it is a standard property
>> for specifying something specific to hardware) instead of "coresight,hwid".
>> I would prefer to stick to the DT graph bindings, because :
> 
> "unit" is not a standard property and I don't like it either.
> 
>>
>> 1) The connections are bi-directional => Well, not necessarily
>> bi-directional
>> in terms of the data flow. But the connection information is critical. i.e,
>> we need information about both the end-points of a connection, which the DT
>> graph bindings solves.
>>
>> All we are missing is a way for specifying the "hardware port" number and
>> the
>> direction of flow. I don't see why do we need to create something new just
>> for
>> these two properties for something that exists today and works reasonably
>> well
>> for the usecase.

Rob,

> 
> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
> 
> in-ports {
>    port@0 {
>      reg = <0>;
>      endpoint {...};
>    };
>    port@1 {
>      reg = <1>;
>      endpoint {...};
>    };
> };
> out-ports {
>    port@0 {
>      reg = <0>;
>      endpoint {...};
>    };
> };
> 
> I'll need to check, but dtc may need an update to not warn about this.

Ok, that looks good.

> 
>>
>>>
>>> What are you trying to say about being sharply different than ACPI?
>>
>>
>> The proposed Coresight ACPI draft bindings are based on the ACPI Graph
>> bindings
>> (just like the DT graph bindings and is compatible with it, in terms of the
>> APIs.
>> i.e, fwnode_graph_* operations work for both ACPI and DT  alike).
>>
>> So, what Mathieu, in turn means is, if we depart from the DT Graph bindings,
>> which
>> I personally don't see any benefit in.
> 
> If DT bindings can be reused for ACPI, that's fine, but don't expect
> any DT bindings to be accepted simply because they match ACPI
> bindings.

The proposed bindings are not making it compatible with the ACPI. In fact,
the ACPI bindings do need something similar to give us an explicit hardware
port number, which needs to be worked out. The only common theme shared
between the proposed ACPI and current DT bindings are the Generic Graph
bindings for describing the connections, which allows sharing the parsing
code independent of the platform, using fwnode_ops.

Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-15  9:58                         ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-15  9:58 UTC (permalink / raw)
  To: Rob Herring
  Cc: Matt Sealey, Mathieu Poirier, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

On 14/06/18 14:59, Rob Herring wrote:
> On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
> <Suzuki.Poulose@arm.com> wrote:
>> On 13/06/18 22:07, Matt Sealey wrote:
>>>
>>>
>>>
>>>> -----Original Message-----
>>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>>
>>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>>> with it, if people agree to it.
>>>>
>>>>
>>>> If we're going to have something sharply different than ACPI I prefer
>>>> Rob's idea.
>>
>>
>> No, the above comment is about using "unit" ( if it is a standard property
>> for specifying something specific to hardware) instead of "coresight,hwid".
>> I would prefer to stick to the DT graph bindings, because :
> 
> "unit" is not a standard property and I don't like it either.
> 
>>
>> 1) The connections are bi-directional => Well, not necessarily
>> bi-directional
>> in terms of the data flow. But the connection information is critical. i.e,
>> we need information about both the end-points of a connection, which the DT
>> graph bindings solves.
>>
>> All we are missing is a way for specifying the "hardware port" number and
>> the
>> direction of flow. I don't see why do we need to create something new just
>> for
>> these two properties for something that exists today and works reasonably
>> well
>> for the usecase.

Rob,

> 
> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
> 
> in-ports {
>    port@0 {
>      reg = <0>;
>      endpoint {...};
>    };
>    port@1 {
>      reg = <1>;
>      endpoint {...};
>    };
> };
> out-ports {
>    port@0 {
>      reg = <0>;
>      endpoint {...};
>    };
> };
> 
> I'll need to check, but dtc may need an update to not warn about this.

Ok, that looks good.

> 
>>
>>>
>>> What are you trying to say about being sharply different than ACPI?
>>
>>
>> The proposed Coresight ACPI draft bindings are based on the ACPI Graph
>> bindings
>> (just like the DT graph bindings and is compatible with it, in terms of the
>> APIs.
>> i.e, fwnode_graph_* operations work for both ACPI and DT  alike).
>>
>> So, what Mathieu, in turn means is, if we depart from the DT Graph bindings,
>> which
>> I personally don't see any benefit in.
> 
> If DT bindings can be reused for ACPI, that's fine, but don't expect
> any DT bindings to be accepted simply because they match ACPI
> bindings.

The proposed bindings are not making it compatible with the ACPI. In fact,
the ACPI bindings do need something similar to give us an explicit hardware
port number, which needs to be worked out. The only common theme shared
between the proposed ACPI and current DT bindings are the Generic Graph
bindings for describing the connections, which allows sharing the parsing
code independent of the platform, using fwnode_ops.

Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-06-15  9:58                         ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-06-15  9:58 UTC (permalink / raw)
  To: linux-arm-kernel

On 14/06/18 14:59, Rob Herring wrote:
> On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
> <Suzuki.Poulose@arm.com> wrote:
>> On 13/06/18 22:07, Matt Sealey wrote:
>>>
>>>
>>>
>>>> -----Original Message-----
>>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>>
>>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>>> with it, if people agree to it.
>>>>
>>>>
>>>> If we're going to have something sharply different than ACPI I prefer
>>>> Rob's idea.
>>
>>
>> No, the above comment is about using "unit" ( if it is a standard property
>> for specifying something specific to hardware) instead of "coresight,hwid".
>> I would prefer to stick to the DT graph bindings, because :
> 
> "unit" is not a standard property and I don't like it either.
> 
>>
>> 1) The connections are bi-directional => Well, not necessarily
>> bi-directional
>> in terms of the data flow. But the connection information is critical. i.e,
>> we need information about both the end-points of a connection, which the DT
>> graph bindings solves.
>>
>> All we are missing is a way for specifying the "hardware port" number and
>> the
>> direction of flow. I don't see why do we need to create something new just
>> for
>> these two properties for something that exists today and works reasonably
>> well
>> for the usecase.

Rob,

> 
> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
> 
> in-ports {
>    port at 0 {
>      reg = <0>;
>      endpoint {...};
>    };
>    port at 1 {
>      reg = <1>;
>      endpoint {...};
>    };
> };
> out-ports {
>    port at 0 {
>      reg = <0>;
>      endpoint {...};
>    };
> };
> 
> I'll need to check, but dtc may need an update to not warn about this.

Ok, that looks good.

> 
>>
>>>
>>> What are you trying to say about being sharply different than ACPI?
>>
>>
>> The proposed Coresight ACPI draft bindings are based on the ACPI Graph
>> bindings
>> (just like the DT graph bindings and is compatible with it, in terms of the
>> APIs.
>> i.e, fwnode_graph_* operations work for both ACPI and DT  alike).
>>
>> So, what Mathieu, in turn means is, if we depart from the DT Graph bindings,
>> which
>> I personally don't see any benefit in.
> 
> If DT bindings can be reused for ACPI, that's fine, but don't expect
> any DT bindings to be accepted simply because they match ACPI
> bindings.

The proposed bindings are not making it compatible with the ACPI. In fact,
the ACPI bindings do need something similar to give us an explicit hardware
port number, which needs to be worked out. The only common theme shared
between the proposed ACPI and current DT bindings are the Generic Graph
bindings for describing the connections, which allows sharing the parsing
code independent of the platform, using fwnode_ops.

Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-06-14 13:59                       ` Rob Herring
  (?)
@ 2018-07-03  9:44                         ` Suzuki K Poulose
  -1 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-07-03  9:44 UTC (permalink / raw)
  To: Rob Herring
  Cc: Matt Sealey, Mathieu Poirier, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Rob,

On 14/06/18 14:59, Rob Herring wrote:
> On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
> <Suzuki.Poulose@arm.com> wrote:
>> On 13/06/18 22:07, Matt Sealey wrote:
>>>
>>>
>>>
>>>> -----Original Message-----
>>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>>
>>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>>> with it, if people agree to it.
>>>>
>>>>
>>>> If we're going to have something sharply different than ACPI I prefer
>>>> Rob's idea.
>>
>>
>> No, the above comment is about using "unit" ( if it is a standard property
>> for specifying something specific to hardware) instead of "coresight,hwid".
>> I would prefer to stick to the DT graph bindings, because :
> 
> "unit" is not a standard property and I don't like it either.
> 
>>
>> 1) The connections are bi-directional => Well, not necessarily
>> bi-directional
>> in terms of the data flow. But the connection information is critical. i.e,
>> we need information about both the end-points of a connection, which the DT
>> graph bindings solves.
>>
>> All we are missing is a way for specifying the "hardware port" number and
>> the
>> direction of flow. I don't see why do we need to create something new just
>> for
>> these two properties for something that exists today and works reasonably
>> well
>> for the usecase.
> 
> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
> 
> in-ports {
>    port@0 {
>      reg = <0>;
>      endpoint {...};
>    };
>    port@1 {
>      reg = <1>;
>      endpoint {...};
>    };
> };
> out-ports {
>    port@0 {
>      reg = <0>;
>      endpoint {...};
>    };
> };
> 
> I'll need to check, but dtc may need an update to not warn about this.
> 

I did a quick check with the upstream dtc tool and the above form is
doesn't generate any errors.

Mathieu, Rob,

Shall I proceed with the proposal above ?


Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-07-03  9:44                         ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-07-03  9:44 UTC (permalink / raw)
  To: Rob Herring
  Cc: Matt Sealey, Mathieu Poirier, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, frowand.list, Charles Garcia-Tobin, John Horley,
	mike.leach, coresight, linux-kernel, devicetree

Hi Rob,

On 14/06/18 14:59, Rob Herring wrote:
> On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
> <Suzuki.Poulose@arm.com> wrote:
>> On 13/06/18 22:07, Matt Sealey wrote:
>>>
>>>
>>>
>>>> -----Original Message-----
>>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>>
>>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>>> with it, if people agree to it.
>>>>
>>>>
>>>> If we're going to have something sharply different than ACPI I prefer
>>>> Rob's idea.
>>
>>
>> No, the above comment is about using "unit" ( if it is a standard property
>> for specifying something specific to hardware) instead of "coresight,hwid".
>> I would prefer to stick to the DT graph bindings, because :
> 
> "unit" is not a standard property and I don't like it either.
> 
>>
>> 1) The connections are bi-directional => Well, not necessarily
>> bi-directional
>> in terms of the data flow. But the connection information is critical. i.e,
>> we need information about both the end-points of a connection, which the DT
>> graph bindings solves.
>>
>> All we are missing is a way for specifying the "hardware port" number and
>> the
>> direction of flow. I don't see why do we need to create something new just
>> for
>> these two properties for something that exists today and works reasonably
>> well
>> for the usecase.
> 
> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
> 
> in-ports {
>    port@0 {
>      reg = <0>;
>      endpoint {...};
>    };
>    port@1 {
>      reg = <1>;
>      endpoint {...};
>    };
> };
> out-ports {
>    port@0 {
>      reg = <0>;
>      endpoint {...};
>    };
> };
> 
> I'll need to check, but dtc may need an update to not warn about this.
> 

I did a quick check with the upstream dtc tool and the above form is
doesn't generate any errors.

Mathieu, Rob,

Shall I proceed with the proposal above ?


Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
@ 2018-07-03  9:44                         ` Suzuki K Poulose
  0 siblings, 0 replies; 77+ messages in thread
From: Suzuki K Poulose @ 2018-07-03  9:44 UTC (permalink / raw)
  To: linux-arm-kernel

Hi Rob,

On 14/06/18 14:59, Rob Herring wrote:
> On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
> <Suzuki.Poulose@arm.com> wrote:
>> On 13/06/18 22:07, Matt Sealey wrote:
>>>
>>>
>>>
>>>> -----Original Message-----
>>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
>>>>
>>>>> So, if the suggestion is to use an existing property "unit", I am fine
>>>>> with it, if people agree to it.
>>>>
>>>>
>>>> If we're going to have something sharply different than ACPI I prefer
>>>> Rob's idea.
>>
>>
>> No, the above comment is about using "unit" ( if it is a standard property
>> for specifying something specific to hardware) instead of "coresight,hwid".
>> I would prefer to stick to the DT graph bindings, because :
> 
> "unit" is not a standard property and I don't like it either.
> 
>>
>> 1) The connections are bi-directional => Well, not necessarily
>> bi-directional
>> in terms of the data flow. But the connection information is critical. i.e,
>> we need information about both the end-points of a connection, which the DT
>> graph bindings solves.
>>
>> All we are missing is a way for specifying the "hardware port" number and
>> the
>> direction of flow. I don't see why do we need to create something new just
>> for
>> these two properties for something that exists today and works reasonably
>> well
>> for the usecase.
> 
> If you have "in-ports" and "out-ports" nodes, then that gives you
> direction and you can use reg for the "hardware port".
> 
> in-ports {
>    port at 0 {
>      reg = <0>;
>      endpoint {...};
>    };
>    port at 1 {
>      reg = <1>;
>      endpoint {...};
>    };
> };
> out-ports {
>    port at 0 {
>      reg = <0>;
>      endpoint {...};
>    };
> };
> 
> I'll need to check, but dtc may need an update to not warn about this.
> 

I did a quick check with the upstream dtc tool and the above form is
doesn't generate any errors.

Mathieu, Rob,

Shall I proceed with the proposal above ?


Suzuki

^ permalink raw reply	[flat|nested] 77+ messages in thread

* Re: [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings
  2018-07-03  9:44                         ` Suzuki K Poulose
  (?)
  (?)
@ 2018-07-03 16:15                         ` Mathieu Poirier
  -1 siblings, 0 replies; 77+ messages in thread
From: Mathieu Poirier @ 2018-07-03 16:15 UTC (permalink / raw)
  To: Suzuki K. Poulose
  Cc: Rob Herring, Matt Sealey, linux-arm-kernel, Sudeep Holla,
	Mark Rutland, Frank Rowand, Charles Garcia-Tobin, John Horley,
	Mike Leach, coresight, Linux Kernel Mailing List, devicetree

[-- Attachment #1: Type: text/plain, Size: 2270 bytes --]

On Tue, 3 Jul 2018 at 03:44, Suzuki K Poulose <Suzuki.Poulose@arm.com>
wrote:

> Hi Rob,
>
> On 14/06/18 14:59, Rob Herring wrote:
> > On Thu, Jun 14, 2018 at 2:53 AM, Suzuki K Poulose
> > <Suzuki.Poulose@arm.com> wrote:
> >> On 13/06/18 22:07, Matt Sealey wrote:
> >>>
> >>>
> >>>
> >>>> -----Original Message-----
> >>>> From: Mathieu Poirier <mathieu.poirier@linaro.org>
> >>>>
> >>>>> So, if the suggestion is to use an existing property "unit", I am
> fine
> >>>>> with it, if people agree to it.
> >>>>
> >>>>
> >>>> If we're going to have something sharply different than ACPI I prefer
> >>>> Rob's idea.
> >>
> >>
> >> No, the above comment is about using "unit" ( if it is a standard
> property
> >> for specifying something specific to hardware) instead of
> "coresight,hwid".
> >> I would prefer to stick to the DT graph bindings, because :
> >
> > "unit" is not a standard property and I don't like it either.
> >
> >>
> >> 1) The connections are bi-directional => Well, not necessarily
> >> bi-directional
> >> in terms of the data flow. But the connection information is critical.
> i.e,
> >> we need information about both the end-points of a connection, which
> the DT
> >> graph bindings solves.
> >>
> >> All we are missing is a way for specifying the "hardware port" number
> and
> >> the
> >> direction of flow. I don't see why do we need to create something new
> just
> >> for
> >> these two properties for something that exists today and works
> reasonably
> >> well
> >> for the usecase.
> >
> > If you have "in-ports" and "out-ports" nodes, then that gives you
> > direction and you can use reg for the "hardware port".
> >
> > in-ports {
> >    port@0 {
> >      reg = <0>;
> >      endpoint {...};
> >    };
> >    port@1 {
> >      reg = <1>;
> >      endpoint {...};
> >    };
> > };
> > out-ports {
> >    port@0 {
> >      reg = <0>;
> >      endpoint {...};
> >    };
> > };
> >
> > I'll need to check, but dtc may need an update to not warn about this.
> >
>
> I did a quick check with the upstream dtc tool and the above form is
> doesn't generate any errors.
>
> Mathieu, Rob,
>
> Shall I proceed with the proposal above ?
>


Yes - at the very least it will provide a new reference point to work form.

Thanks,
Mathieu


>
>
Suzuki
>

[-- Attachment #2: Type: text/html, Size: 3663 bytes --]

^ permalink raw reply	[flat|nested] 77+ messages in thread

end of thread, other threads:[~2018-07-03 16:15 UTC | newest]

Thread overview: 77+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2018-06-01 13:15 [RFC PATCH 0/8] coresight: Update device tree bindings Suzuki K Poulose
2018-06-01 13:15 ` Suzuki K Poulose
2018-06-01 13:16 ` [RFC PATCH 1/8] dts: binding: coresight: Document graph bindings Suzuki K Poulose
2018-06-01 13:16   ` Suzuki K Poulose
2018-06-01 16:14   ` Mathieu Poirier
2018-06-01 16:14     ` Mathieu Poirier
2018-06-01 13:16 ` [RFC PATCH 2/8] coresight: Fix remote endpoint parsing Suzuki K Poulose
2018-06-01 13:16   ` Suzuki K Poulose
2018-06-01 19:38   ` Mathieu Poirier
2018-06-01 19:38     ` Mathieu Poirier
2018-06-01 19:46     ` Mathieu Poirier
2018-06-01 19:46       ` Mathieu Poirier
2018-06-04 10:34       ` Suzuki K Poulose
2018-06-04 10:34         ` Suzuki K Poulose
2018-06-01 13:16 ` [RFC PATCH 3/8] coresight: Cleanup platform description data Suzuki K Poulose
2018-06-01 13:16   ` Suzuki K Poulose
2018-06-01 13:16 ` [RFC PATCH 4/8] coresight: platform: Cleanup coresight connection handling Suzuki K Poulose
2018-06-01 13:16   ` Suzuki K Poulose
2018-06-01 13:16 ` [RFC PATCH 5/8] coresight: Handle errors in finding input/output ports Suzuki K Poulose
2018-06-01 13:16   ` Suzuki K Poulose
2018-06-01 13:16 ` [RFC PATCH 6/8] dts: coresight: Clean up the device tree graph bindings Suzuki K Poulose
2018-06-01 13:16   ` Suzuki K Poulose
2018-06-01 20:26   ` Mathieu Poirier
2018-06-01 20:26     ` Mathieu Poirier
2018-06-12 20:48   ` Rob Herring
2018-06-12 20:48     ` Rob Herring
2018-06-13  9:45     ` Suzuki K Poulose
2018-06-13  9:45       ` Suzuki K Poulose
2018-06-13 12:49       ` Matt Sealey
2018-06-13 12:49         ` Matt Sealey
2018-06-13 12:49         ` Matt Sealey
2018-06-13 13:35         ` Suzuki K Poulose
2018-06-13 13:35           ` Suzuki K Poulose
2018-06-13 13:35           ` Suzuki K Poulose
2018-06-13 13:57           ` Rob Herring
2018-06-13 13:57             ` Rob Herring
2018-06-13 13:57             ` Rob Herring
2018-06-13 15:47           ` Matt Sealey
2018-06-13 15:47             ` Matt Sealey
2018-06-13 15:47             ` Matt Sealey
2018-06-13 17:07             ` Suzuki K Poulose
2018-06-13 17:07               ` Suzuki K Poulose
2018-06-13 17:07               ` Suzuki K Poulose
2018-06-13 19:40               ` Mathieu Poirier
2018-06-13 19:40                 ` Mathieu Poirier
2018-06-13 19:40                 ` Mathieu Poirier
2018-06-13 21:07                 ` Matt Sealey
2018-06-13 21:07                   ` Matt Sealey
2018-06-13 21:07                   ` Matt Sealey
2018-06-14  8:53                   ` Suzuki K Poulose
2018-06-14  8:53                     ` Suzuki K Poulose
2018-06-14  8:53                     ` Suzuki K Poulose
2018-06-14 13:59                     ` Rob Herring
2018-06-14 13:59                       ` Rob Herring
2018-06-14 13:59                       ` Rob Herring
2018-06-14 15:04                       ` Matt Sealey
2018-06-14 15:04                         ` Matt Sealey
2018-06-14 15:04                         ` Matt Sealey
2018-06-15  9:58                       ` Suzuki K Poulose
2018-06-15  9:58                         ` Suzuki K Poulose
2018-06-15  9:58                         ` Suzuki K Poulose
2018-07-03  9:44                       ` Suzuki K Poulose
2018-07-03  9:44                         ` Suzuki K Poulose
2018-07-03  9:44                         ` Suzuki K Poulose
2018-07-03 16:15                         ` Mathieu Poirier
2018-06-01 13:16 ` [RFC PATCH 7/8] dts: coresight: Define new bindings for direction of data flow Suzuki K Poulose
2018-06-01 13:16   ` Suzuki K Poulose
2018-06-01 20:39   ` Mathieu Poirier
2018-06-01 20:39     ` Mathieu Poirier
2018-06-04 14:20     ` Suzuki K Poulose
2018-06-04 14:20       ` Suzuki K Poulose
2018-06-01 13:16 ` [RFC PATCH 8/8] dts: juno: Update coresight bindings for hw port Suzuki K Poulose
2018-06-01 13:16   ` Suzuki K Poulose
2018-06-01 20:59   ` Mathieu Poirier
2018-06-01 20:59     ` Mathieu Poirier
2018-06-01 21:04 ` [RFC PATCH 0/8] coresight: Update device tree bindings Mathieu Poirier
2018-06-01 21:04   ` Mathieu Poirier