All of lore.kernel.org
 help / color / mirror / Atom feed
From: Martin Kepplinger <martin.kepplinger@puri.sm>
To: Ulf Hansson <ulf.hansson@linaro.org>
Cc: rafael@kernel.org, khilman@kernel.org, robh@kernel.org,
	krzysztof.kozlowski@linaro.org, shawnguo@kernel.org,
	s.hauer@pengutronix.de, festevam@gmail.com, pavel@ucw.cz,
	kernel@puri.sm, linux-imx@nxp.com, broonie@kernel.org,
	l.stach@pengutronix.de, aford173@gmail.com,
	linux-pm@vger.kernel.org, devicetree@vger.kernel.org,
	linux-kernel@vger.kernel.org,
	linux-arm-kernel@lists.infradead.org
Subject: Re: [PATCH v6 1/2] power: domain: handle genpd correctly when needing interrupts
Date: Fri, 19 Aug 2022 11:17:40 +0200	[thread overview]
Message-ID: <d1db07c8ca57c72b4f0820fcb6832dd7e4501055.camel@puri.sm> (raw)
In-Reply-To: <CAPDyKFrLLw=y9+t3f_bOH2mw2NVDGJxKE5=+XHY7C6SUzLzUDg@mail.gmail.com>

Am Dienstag, dem 26.07.2022 um 17:07 +0200 schrieb Ulf Hansson:
> On Tue, 26 Jul 2022 at 10:33, Martin Kepplinger
> <martin.kepplinger@puri.sm> wrote:
> > 
> > If for example the power-domains' power-supply node (regulator)
> > needs
> > interrupts to work, the current setup with noirq callbacks cannot
> > work; for example a pmic regulator on i2c, when suspending, usually
> > already
> > times out during suspend_noirq:
> > 
> > [   41.024193] buck4: failed to disable: -ETIMEDOUT
> > 
> > So fix system suspend and resume for these power-domains by using
> > the
> > "outer" suspend/resume callbacks instead. Tested on the imx8mq-
> > librem5 board,
> > but by looking at the dts, this will fix imx8mq-evk and possibly
> > many other
> > boards too.
> > 
> > This is designed so that genpd providers just say "this genpd needs
> > interrupts" (by setting the flag) - without implying an
> > implementation.
> > 
> > Initially system suspend problems had been discussed at
> > https://lore.kernel.org/linux-arm-kernel/20211002005954.1367653-8-l.stach@pengutronix.de/
> > which led to discussing the pmic that contains the regulators which
> > serve as power-domain power-supplies:
> > https://lore.kernel.org/linux-pm/573166b75e524517782471c2b7f96e03fd93d175.camel@puri.sm/T/
> > 
> > Signed-off-by: Martin Kepplinger <martin.kepplinger@puri.sm>
> > ---
> >  drivers/base/power/domain.c | 13 +++++++++++--
> >  include/linux/pm_domain.h   |  5 +++++
> >  2 files changed, 16 insertions(+), 2 deletions(-)
> > 
> > diff --git a/drivers/base/power/domain.c
> > b/drivers/base/power/domain.c
> > index 5a2e0232862e..58376752a4de 100644
> > --- a/drivers/base/power/domain.c
> > +++ b/drivers/base/power/domain.c
> > @@ -130,6 +130,7 @@ static const struct genpd_lock_ops
> > genpd_spin_ops = {
> >  #define genpd_is_active_wakeup(genpd)  (genpd->flags &
> > GENPD_FLAG_ACTIVE_WAKEUP)
> >  #define genpd_is_cpu_domain(genpd)     (genpd->flags &
> > GENPD_FLAG_CPU_DOMAIN)
> >  #define genpd_is_rpm_always_on(genpd)  (genpd->flags &
> > GENPD_FLAG_RPM_ALWAYS_ON)
> > +#define genpd_irq_on(genpd)            (genpd->flags &
> > GENPD_FLAG_IRQ_ON)
> > 
> >  static inline bool irq_safe_dev_in_sleep_domain(struct device
> > *dev,
> >                 const struct generic_pm_domain *genpd)
> > @@ -2065,8 +2066,15 @@ int pm_genpd_init(struct generic_pm_domain
> > *genpd,
> >         genpd->domain.ops.runtime_suspend = genpd_runtime_suspend;
> >         genpd->domain.ops.runtime_resume = genpd_runtime_resume;
> >         genpd->domain.ops.prepare = genpd_prepare;
> > -       genpd->domain.ops.suspend_noirq = genpd_suspend_noirq;
> > -       genpd->domain.ops.resume_noirq = genpd_resume_noirq;
> > +
> > +       if (genpd_irq_on(genpd)) {
> > +               genpd->domain.ops.suspend = genpd_suspend_noirq;
> > +               genpd->domain.ops.resume = genpd_resume_noirq;
> > +       } else {
> > +               genpd->domain.ops.suspend_noirq =
> > genpd_suspend_noirq;
> > +               genpd->domain.ops.resume_noirq =
> > genpd_resume_noirq;
> 
> As we discussed previously, I am thinking that it may be better to
> move to using genpd->domain.ops.suspend_late and
> genpd->domain.ops.resume_early instead.

Wouldn't that better be a separate patch (on top)? Do you really want
me to change the current behaviour (default case) to from noirq to
late? Then I'll resend this series with such a patch added.

thanks,

                              martin

> 
> Beside this, I think the $subject patch looks good to me.
> 
> [...]
> 
> Kind regards
> Uffe



WARNING: multiple messages have this Message-ID (diff)
From: Martin Kepplinger <martin.kepplinger@puri.sm>
To: Ulf Hansson <ulf.hansson@linaro.org>
Cc: rafael@kernel.org, khilman@kernel.org, robh@kernel.org,
	 krzysztof.kozlowski@linaro.org, shawnguo@kernel.org,
	s.hauer@pengutronix.de,  festevam@gmail.com, pavel@ucw.cz,
	kernel@puri.sm, linux-imx@nxp.com,  broonie@kernel.org,
	l.stach@pengutronix.de, aford173@gmail.com,
	 linux-pm@vger.kernel.org, devicetree@vger.kernel.org,
	 linux-kernel@vger.kernel.org,
	linux-arm-kernel@lists.infradead.org
Subject: Re: [PATCH v6 1/2] power: domain: handle genpd correctly when needing interrupts
Date: Fri, 19 Aug 2022 11:17:40 +0200	[thread overview]
Message-ID: <d1db07c8ca57c72b4f0820fcb6832dd7e4501055.camel@puri.sm> (raw)
In-Reply-To: <CAPDyKFrLLw=y9+t3f_bOH2mw2NVDGJxKE5=+XHY7C6SUzLzUDg@mail.gmail.com>

Am Dienstag, dem 26.07.2022 um 17:07 +0200 schrieb Ulf Hansson:
> On Tue, 26 Jul 2022 at 10:33, Martin Kepplinger
> <martin.kepplinger@puri.sm> wrote:
> > 
> > If for example the power-domains' power-supply node (regulator)
> > needs
> > interrupts to work, the current setup with noirq callbacks cannot
> > work; for example a pmic regulator on i2c, when suspending, usually
> > already
> > times out during suspend_noirq:
> > 
> > [   41.024193] buck4: failed to disable: -ETIMEDOUT
> > 
> > So fix system suspend and resume for these power-domains by using
> > the
> > "outer" suspend/resume callbacks instead. Tested on the imx8mq-
> > librem5 board,
> > but by looking at the dts, this will fix imx8mq-evk and possibly
> > many other
> > boards too.
> > 
> > This is designed so that genpd providers just say "this genpd needs
> > interrupts" (by setting the flag) - without implying an
> > implementation.
> > 
> > Initially system suspend problems had been discussed at
> > https://lore.kernel.org/linux-arm-kernel/20211002005954.1367653-8-l.stach@pengutronix.de/
> > which led to discussing the pmic that contains the regulators which
> > serve as power-domain power-supplies:
> > https://lore.kernel.org/linux-pm/573166b75e524517782471c2b7f96e03fd93d175.camel@puri.sm/T/
> > 
> > Signed-off-by: Martin Kepplinger <martin.kepplinger@puri.sm>
> > ---
> >  drivers/base/power/domain.c | 13 +++++++++++--
> >  include/linux/pm_domain.h   |  5 +++++
> >  2 files changed, 16 insertions(+), 2 deletions(-)
> > 
> > diff --git a/drivers/base/power/domain.c
> > b/drivers/base/power/domain.c
> > index 5a2e0232862e..58376752a4de 100644
> > --- a/drivers/base/power/domain.c
> > +++ b/drivers/base/power/domain.c
> > @@ -130,6 +130,7 @@ static const struct genpd_lock_ops
> > genpd_spin_ops = {
> >  #define genpd_is_active_wakeup(genpd)  (genpd->flags &
> > GENPD_FLAG_ACTIVE_WAKEUP)
> >  #define genpd_is_cpu_domain(genpd)     (genpd->flags &
> > GENPD_FLAG_CPU_DOMAIN)
> >  #define genpd_is_rpm_always_on(genpd)  (genpd->flags &
> > GENPD_FLAG_RPM_ALWAYS_ON)
> > +#define genpd_irq_on(genpd)            (genpd->flags &
> > GENPD_FLAG_IRQ_ON)
> > 
> >  static inline bool irq_safe_dev_in_sleep_domain(struct device
> > *dev,
> >                 const struct generic_pm_domain *genpd)
> > @@ -2065,8 +2066,15 @@ int pm_genpd_init(struct generic_pm_domain
> > *genpd,
> >         genpd->domain.ops.runtime_suspend = genpd_runtime_suspend;
> >         genpd->domain.ops.runtime_resume = genpd_runtime_resume;
> >         genpd->domain.ops.prepare = genpd_prepare;
> > -       genpd->domain.ops.suspend_noirq = genpd_suspend_noirq;
> > -       genpd->domain.ops.resume_noirq = genpd_resume_noirq;
> > +
> > +       if (genpd_irq_on(genpd)) {
> > +               genpd->domain.ops.suspend = genpd_suspend_noirq;
> > +               genpd->domain.ops.resume = genpd_resume_noirq;
> > +       } else {
> > +               genpd->domain.ops.suspend_noirq =
> > genpd_suspend_noirq;
> > +               genpd->domain.ops.resume_noirq =
> > genpd_resume_noirq;
> 
> As we discussed previously, I am thinking that it may be better to
> move to using genpd->domain.ops.suspend_late and
> genpd->domain.ops.resume_early instead.

Wouldn't that better be a separate patch (on top)? Do you really want
me to change the current behaviour (default case) to from noirq to
late? Then I'll resend this series with such a patch added.

thanks,

                              martin

> 
> Beside this, I think the $subject patch looks good to me.
> 
> [...]
> 
> Kind regards
> Uffe



_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel

  parent reply	other threads:[~2022-08-19  9:17 UTC|newest]

Thread overview: 32+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2022-07-26  8:32 [PATCH v6 0/2] power: domain: handle power supplies that need interrupts Martin Kepplinger
2022-07-26  8:32 ` Martin Kepplinger
2022-07-26  8:32 ` [PATCH v6 1/2] power: domain: handle genpd correctly when needing interrupts Martin Kepplinger
2022-07-26  8:32   ` Martin Kepplinger
2022-07-26 15:07   ` Ulf Hansson
2022-07-26 15:07     ` Ulf Hansson
2022-07-26 18:33     ` Rafael J. Wysocki
2022-07-26 18:33       ` Rafael J. Wysocki
2022-07-28  9:19       ` Ulf Hansson
2022-07-28  9:19         ` Ulf Hansson
2022-08-19  9:17     ` Martin Kepplinger [this message]
2022-08-19  9:17       ` Martin Kepplinger
2022-08-19 14:53       ` Ulf Hansson
2022-08-19 14:53         ` Ulf Hansson
2022-08-22  8:38         ` Martin Kepplinger
2022-08-22  8:38           ` Martin Kepplinger
2022-08-24 13:30           ` Ulf Hansson
2022-08-24 13:30             ` Ulf Hansson
2022-08-25  7:06             ` Martin Kepplinger
2022-08-25  7:06               ` Martin Kepplinger
2022-09-23 13:55               ` Ulf Hansson
2022-09-23 13:55                 ` Ulf Hansson
2022-09-26  9:52                 ` Martin Kepplinger
2022-09-26  9:52                   ` Martin Kepplinger
2023-06-21 18:20                 ` Martin Kepplinger
2023-06-21 18:20                   ` Martin Kepplinger
2023-06-26  9:50                   ` Ulf Hansson
2023-06-26  9:50                     ` Ulf Hansson
2022-07-26  8:32 ` [PATCH v6 2/2] soc: imx: gpcv2: fix suspend/resume by setting GENPD_FLAG_IRQ_ON Martin Kepplinger
2022-07-26  8:32   ` Martin Kepplinger
2022-07-26 15:08   ` Ulf Hansson
2022-07-26 15:08     ` Ulf Hansson

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=d1db07c8ca57c72b4f0820fcb6832dd7e4501055.camel@puri.sm \
    --to=martin.kepplinger@puri.sm \
    --cc=aford173@gmail.com \
    --cc=broonie@kernel.org \
    --cc=devicetree@vger.kernel.org \
    --cc=festevam@gmail.com \
    --cc=kernel@puri.sm \
    --cc=khilman@kernel.org \
    --cc=krzysztof.kozlowski@linaro.org \
    --cc=l.stach@pengutronix.de \
    --cc=linux-arm-kernel@lists.infradead.org \
    --cc=linux-imx@nxp.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pm@vger.kernel.org \
    --cc=pavel@ucw.cz \
    --cc=rafael@kernel.org \
    --cc=robh@kernel.org \
    --cc=s.hauer@pengutronix.de \
    --cc=shawnguo@kernel.org \
    --cc=ulf.hansson@linaro.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.