linux-kernel.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
From: Thara Gopinath <thara.gopinath@linaro.org>
To: Ionela Voinescu <ionela.voinescu@arm.com>,
	Vincent Guittot <vincent.guittot@linaro.org>
Cc: Dietmar Eggemann <dietmar.eggemann@arm.com>,
	Ingo Molnar <mingo@redhat.com>,
	Peter Zijlstra <peterz@infradead.org>,
	Zhang Rui <rui.zhang@intel.com>,
	Eduardo Valentin <edubezval@gmail.com>,
	Quentin Perret <qperret@google.com>,
	linux-kernel <linux-kernel@vger.kernel.org>,
	Amit Kachhap <amit.kachhap@gmail.com>,
	Javi Merino <javi.merino@kernel.org>,
	Daniel Lezcano <daniel.lezcano@linaro.org>
Subject: Re: [Patch v4 5/6] thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping
Date: Fri, 1 Nov 2019 17:04:47 -0400	[thread overview]
Message-ID: <5DBC9DEF.6030007@linaro.org> (raw)
In-Reply-To: <20191101154612.GA4884@e108754-lin>

On 11/01/2019 11:47 AM, Ionela Voinescu wrote:
> Hi guys,
> 
> On Thursday 31 Oct 2019 at 17:38:25 (+0100), Vincent Guittot wrote:
>> On Thu, 31 Oct 2019 at 17:29, Dietmar Eggemann <dietmar.eggemann@arm.com> wrote:
>>>
>>> On 22.10.19 22:34, Thara Gopinath wrote:
>>>> Thermal governors can request for a cpu's maximum supported frequency
>>>> to be capped in case of an overheat event. This in turn means that the
>>>> maximum capacity available for tasks to run on the particular cpu is
>>>> reduced. Delta between the original maximum capacity and capped
>>>> maximum capacity is known as thermal pressure. Enable cpufreq cooling
>>>> device to update the thermal pressure in event of a capped
>>>> maximum frequency.
>>>>
>>>> Signed-off-by: Thara Gopinath <thara.gopinath@linaro.org>
>>>> ---
>>>>  drivers/thermal/cpu_cooling.c | 31 +++++++++++++++++++++++++++++--
>>>>  1 file changed, 29 insertions(+), 2 deletions(-)
>>>>
>>>> diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
>>>> index 391f397..2e6a979 100644
>>>> --- a/drivers/thermal/cpu_cooling.c
>>>> +++ b/drivers/thermal/cpu_cooling.c
>>>> @@ -218,6 +218,23 @@ static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev,
>>>>  }
>>>>
>>>>  /**
>>>> + * update_sched_max_capacity - update scheduler about change in cpu
>>>> + *                                   max frequency.
>>>> + * @policy - cpufreq policy whose max frequency is capped.
>>>> + */
>>>> +static void update_sched_max_capacity(struct cpumask *cpus,
>>>> +                                   unsigned int cur_max_freq,
>>>> +                                   unsigned int max_freq)
>>>> +{
>>>> +     int cpu;
>>>> +     unsigned long capacity = (cur_max_freq << SCHED_CAPACITY_SHIFT) /
>>>> +                               max_freq;
>>>> +
>>>> +     for_each_cpu(cpu, cpus)
>>>> +             update_thermal_pressure(cpu, capacity);
>>>> +}
>>>> +
>>>> +/**
>>>>   * get_load() - get load for a cpu since last updated
>>>>   * @cpufreq_cdev:    &struct cpufreq_cooling_device for this cpu
>>>>   * @cpu:     cpu number
>>>> @@ -320,6 +337,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
>>>>                                unsigned long state)
>>>>  {
>>>>       struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
>>>> +     int ret;
>>>>
>>>>       /* Request state should be less than max_level */
>>>>       if (WARN_ON(state > cpufreq_cdev->max_level))
>>>> @@ -331,8 +349,17 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
>>>>
>>>>       cpufreq_cdev->cpufreq_state = state;
>>>>
>>>> -     return dev_pm_qos_update_request(&cpufreq_cdev->qos_req,
>>>> -                             cpufreq_cdev->freq_table[state].frequency);
>>>> +     ret = dev_pm_qos_update_request
>>>> +                             (&cpufreq_cdev->qos_req,
>>>> +                              cpufreq_cdev->freq_table[state].frequency);
>>>> +
>>>> +     if (ret > 0)
>>>> +             update_sched_max_capacity
>>>> +                             (cpufreq_cdev->policy->cpus,
>>>> +                              cpufreq_cdev->freq_table[state].frequency,
>>>> +                              cpufreq_cdev->policy->cpuinfo.max_freq);
>>>> +
>>>> +     return ret;
>>>>  }
>>>>
>>>>  /**
>>>>
>>>
>>> Why not getting rid of update_sched_max_capacity() entirely and call
>>> update_thermal_pressure() in cpu_cooling.c directly? Saves one level in
>>> the call chain and would mean less code for this feature.
>>
>> But you add complexity in update_thermal_pressure which now has to
>> deal with a cpumask and to compute some frequency ratio
>> IMHO, it's cleaner to keep update_thermal_pressure simple as it is now
>>
> 
> How about removing update_thermal_pressure altogether and doing all the
> work in update_sched_max_capacity? That is, have
> update_sched_max_capacity compute the capped_freq_ratio, do the
> normalization, and set it per_cpu for all CPUs in the frequency domain.
> You'll save some calculations that you're now doing in
> update_thermal_pressure for each cpu and you avoid shifting back and
> forth.

Yes.  I can pass the delta to update_thermal_pressure. I will still want
to keep update_thermal_pressure and a per cpu variable in fair.c to
store this.
> 
> If you're doing so it would be worth renaming update_sched_max_capacity
> to something like update_sched_thermal_pressure.
Will do.


-- 
Warm Regards
Thara

  reply	other threads:[~2019-11-01 21:04 UTC|newest]

Thread overview: 51+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2019-10-22 20:34 [Patch v4 0/6] Introduce Thermal Pressure Thara Gopinath
2019-10-22 20:34 ` [Patch v4 1/6] sched/pelt.c: Add support to track thermal pressure Thara Gopinath
2019-10-31  9:47   ` Ionela Voinescu
2019-10-22 20:34 ` [Patch v4 2/6] sched: Add infrastructure to store and update instantaneous " Thara Gopinath
2019-10-28 15:21   ` Peter Zijlstra
2019-10-30 21:37     ` Thara Gopinath
2019-11-01 12:17   ` Dietmar Eggemann
2019-11-01 20:57     ` Thara Gopinath
2019-11-04 17:29       ` Dietmar Eggemann
2019-11-04 17:34         ` Vincent Guittot
2019-11-04 17:41           ` Dietmar Eggemann
2019-11-04 17:48             ` Vincent Guittot
2019-10-22 20:34 ` [Patch v4 3/6] sched/fair: Enable CFS periodic tick to update " Thara Gopinath
2019-10-28 15:24   ` Peter Zijlstra
2019-10-28 15:27     ` Peter Zijlstra
2019-10-30 21:41     ` Thara Gopinath
2019-10-31 16:11   ` Dietmar Eggemann
2019-10-31 16:46     ` Thara Gopinath
2019-10-22 20:34 ` [Patch v4 4/6] sched/fair: update cpu_capcity to reflect " Thara Gopinath
2019-10-23 12:28   ` Qais Yousef
2019-10-28 15:30     ` Peter Zijlstra
2019-10-31 10:53       ` Qais Yousef
2019-10-31 15:38         ` Dietmar Eggemann
2019-10-31 15:48           ` Vincent Guittot
2019-10-31 16:17             ` Dietmar Eggemann
2019-10-31 16:31               ` Vincent Guittot
2019-10-31 16:44                 ` Dietmar Eggemann
2019-10-31 16:03         ` Thara Gopinath
2019-10-31 16:56           ` Qais Yousef
2019-10-22 20:34 ` [Patch v4 5/6] thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping Thara Gopinath
2019-10-28 15:33   ` Peter Zijlstra
2019-10-31 16:29   ` Dietmar Eggemann
2019-10-31 16:38     ` Vincent Guittot
2019-11-01 15:47       ` Ionela Voinescu
2019-11-01 21:04         ` Thara Gopinath [this message]
2019-11-04 14:41           ` Ionela Voinescu
2019-10-31 16:46     ` Thara Gopinath
2019-10-22 20:34 ` [Patch v4 6/6] sched: thermal: Enable tuning of decay period Thara Gopinath
2019-10-28 15:42   ` Peter Zijlstra
2019-11-04 16:12   ` Ionela Voinescu
2019-11-05 20:26     ` Thara Gopinath
2019-11-05 21:29       ` Ionela Voinescu
2019-10-29 15:34 ` [Patch v4 0/6] Introduce Thermal Pressure Daniel Lezcano
2019-10-31 10:07   ` Ionela Voinescu
2019-10-31 11:54     ` Daniel Lezcano
2019-10-31 12:57       ` Ionela Voinescu
2019-10-31 17:48         ` Daniel Lezcano
2019-10-31  9:44 ` Ionela Voinescu
2019-10-31 16:41   ` Thara Gopinath
2019-10-31 16:52     ` Thara Gopinath
2019-11-05 21:04     ` Ionela Voinescu

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=5DBC9DEF.6030007@linaro.org \
    --to=thara.gopinath@linaro.org \
    --cc=amit.kachhap@gmail.com \
    --cc=daniel.lezcano@linaro.org \
    --cc=dietmar.eggemann@arm.com \
    --cc=edubezval@gmail.com \
    --cc=ionela.voinescu@arm.com \
    --cc=javi.merino@kernel.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=mingo@redhat.com \
    --cc=peterz@infradead.org \
    --cc=qperret@google.com \
    --cc=rui.zhang@intel.com \
    --cc=vincent.guittot@linaro.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).