Subject: Re: [Patch v4 5/6] thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping
Date: Thu, 31 Oct 2019 17:38:25 +0100	[thread overview]
Message-ID: <CAKfTPtCpZq61gQVpATtTdg5hDA+tP4bF6xPMsvHYUMoY+H-6FQ@mail.gmail.com> (raw)
In-Reply-To: <2b19d7da-412c-932f-7251-110eadbef3e3@arm.com>

On Thu, 31 Oct 2019 at 17:29, Dietmar Eggemann <dietmar.eggemann@arm.com> wrote:
>
> On 22.10.19 22:34, Thara Gopinath wrote:
> > Thermal governors can request for a cpu's maximum supported frequency
> > to be capped in case of an overheat event. This in turn means that the
> > maximum capacity available for tasks to run on the particular cpu is
> > reduced. Delta between the original maximum capacity and capped
> > maximum capacity is known as thermal pressure. Enable cpufreq cooling
> > device to update the thermal pressure in event of a capped
> > maximum frequency.
> >
> > Signed-off-by: Thara Gopinath <thara.gopinath@linaro.org>
> > ---
> >  drivers/thermal/cpu_cooling.c | 31 +++++++++++++++++++++++++++++--
> >  1 file changed, 29 insertions(+), 2 deletions(-)
> >
> > diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
> > index 391f397..2e6a979 100644
> > --- a/drivers/thermal/cpu_cooling.c
> > +++ b/drivers/thermal/cpu_cooling.c
> > @@ -218,6 +218,23 @@ static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev,
> >  }
> >
> >  /**
> > + * update_sched_max_capacity - update scheduler about change in cpu
> > + *                                   max frequency.
> > + * @policy - cpufreq policy whose max frequency is capped.
> > + */
> > +static void update_sched_max_capacity(struct cpumask *cpus,
> > +                                   unsigned int cur_max_freq,
> > +                                   unsigned int max_freq)
> > +{
> > +     int cpu;
> > +     unsigned long capacity = (cur_max_freq << SCHED_CAPACITY_SHIFT) /
> > +                               max_freq;
> > +
> > +     for_each_cpu(cpu, cpus)
> > +             update_thermal_pressure(cpu, capacity);
> > +}
> > +
> > +/**
> >   * get_load() - get load for a cpu since last updated
> >   * @cpufreq_cdev:    &struct cpufreq_cooling_device for this cpu
> >   * @cpu:     cpu number
> > @@ -320,6 +337,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
> >                                unsigned long state)
> >  {
> >       struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
> > +     int ret;
> >
> >       /* Request state should be less than max_level */
> >       if (WARN_ON(state > cpufreq_cdev->max_level))
> > @@ -331,8 +349,17 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
> >
> >       cpufreq_cdev->cpufreq_state = state;
> >
> > -     return dev_pm_qos_update_request(&cpufreq_cdev->qos_req,
> > -                             cpufreq_cdev->freq_table[state].frequency);
> > +     ret = dev_pm_qos_update_request
> > +                             (&cpufreq_cdev->qos_req,
> > +                              cpufreq_cdev->freq_table[state].frequency);
> > +
> > +     if (ret > 0)
> > +             update_sched_max_capacity
> > +                             (cpufreq_cdev->policy->cpus,
> > +                              cpufreq_cdev->freq_table[state].frequency,
> > +                              cpufreq_cdev->policy->cpuinfo.max_freq);
> > +
> > +     return ret;
> >  }
> >
> >  /**
> >
>
> Why not getting rid of update_sched_max_capacity() entirely and call
> update_thermal_pressure() in cpu_cooling.c directly? Saves one level in
> the call chain and would mean less code for this feature.

But you add complexity in update_thermal_pressure which now has to
deal with a cpumask and to compute some frequency ratio
IMHO, it's cleaner to keep update_thermal_pressure simple as it is now

>
> Just compile tested on arm64:
>
> diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
> index 3211b4d3a899..bf36995013b0 100644
> --- a/drivers/thermal/cpu_cooling.c
> +++ b/drivers/thermal/cpu_cooling.c
> @@ -217,23 +217,6 @@ static u32 cpu_power_to_freq(struct
> cpufreq_cooling_device *cpufreq_cdev,
>         return freq_table[i - 1].frequency;
>  }
>
> -/**
> - * update_sched_max_capacity - update scheduler about change in cpu
> - *                                     max frequency.
> - * @policy - cpufreq policy whose max frequency is capped.
> - */
> -static void update_sched_max_capacity(struct cpumask *cpus,
> -                                     unsigned int cur_max_freq,
> -                                     unsigned int max_freq)
> -{
> -       int cpu;
> -       unsigned long capacity = (cur_max_freq << SCHED_CAPACITY_SHIFT) /
> -                                 max_freq;
> -
> -       for_each_cpu(cpu, cpus)
> -               update_thermal_pressure(cpu, capacity);
> -}
> -
>  /**
>   * get_load() - get load for a cpu since last updated
>   * @cpufreq_cdev:      &struct cpufreq_cooling_device for this cpu
> @@ -353,7 +336,7 @@ static int cpufreq_set_cur_state(struct
> thermal_cooling_device *cdev,
>                                 cpufreq_cdev->freq_table[state].frequency);
>
>         if (ret > 0)
> -               update_sched_max_capacity
> +               update_thermal_pressure
>                                 (cpufreq_cdev->policy->cpus,
>                                  cpufreq_cdev->freq_table[state].frequency,
>                                  cpufreq_cdev->policy->cpuinfo.max_freq);
> diff --git a/include/linux/sched.h b/include/linux/sched.h
> index 55dfe9634f67..5707813c7621 100644
> --- a/include/linux/sched.h
> +++ b/include/linux/sched.h
> @@ -1985,9 +1985,9 @@ static inline void rseq_syscall(struct pt_regs *regs)
>  #endif
>
>  #ifdef CONFIG_SMP
> -void update_thermal_pressure(int cpu, u64 capacity);
> +void update_thermal_pressure(struct cpumask *cpus, unsigned int cur,
> unsigned int max);
>  #else
> -static inline void update_thermal_pressure(int cpu, u64 capacity)
> +static inline void update_thermal_pressure(struct cpumask *cpus,
> unsigned int cur, unsigned int max);
>  {
>  }
>  #endif
> diff --git a/kernel/sched/thermal.c b/kernel/sched/thermal.c
> index 0da31e12a5ff..691bdd79597a 100644
> --- a/kernel/sched/thermal.c
> +++ b/kernel/sched/thermal.c
> @@ -43,17 +43,16 @@ static DEFINE_PER_CPU(unsigned long, delta_capacity);
>   * the arch_scale_cpu_capacity and capped capacity is stored in per cpu
>   * delta_capacity.
>   */
> -void update_thermal_pressure(int cpu, u64 capped_freq_ratio)
> +void update_thermal_pressure(struct cpumask *cpus, unsigned int cur,
> unsigned int max)
>  {
> -       unsigned long __capacity, delta;
> +       int cpu;
>
> -       /* Normalize the capped freq ratio */
> -       __capacity = (capped_freq_ratio * arch_scale_cpu_capacity(cpu)) >>
> -
> SCHED_CAPACITY_SHIFT;
> -       delta = arch_scale_cpu_capacity(cpu) -  __capacity;
> -       pr_debug("updating cpu%d thermal pressure to %lu\n", cpu, delta);
> +       for_each_cpu(cpu, cpus) {
> +               unsigned long scale_cap = arch_scale_cpu_capacity(cpu);
> +               unsigned long cur_cap = cur * scale_cap / max;
>
> -       per_cpu(delta_capacity, cpu) = delta;
> +               per_cpu(delta_capacity, cpu) = scale_cap - cur_cap;
> +       }
>  }

  reply	other threads:[~2019-10-31 16:38 UTC|newest]

Thread overview: 51+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2019-10-22 20:34 [Patch v4 0/6] Introduce Thermal Pressure Thara Gopinath
2019-10-22 20:34 ` [Patch v4 1/6] sched/pelt.c: Add support to track thermal pressure Thara Gopinath
2019-10-31  9:47   ` Ionela Voinescu
2019-10-22 20:34 ` [Patch v4 2/6] sched: Add infrastructure to store and update instantaneous " Thara Gopinath
2019-10-28 15:21   ` Peter Zijlstra
2019-10-30 21:37     ` Thara Gopinath
2019-11-01 12:17   ` Dietmar Eggemann
2019-11-01 20:57     ` Thara Gopinath
2019-11-04 17:29       ` Dietmar Eggemann
2019-11-04 17:34         ` Vincent Guittot
2019-11-04 17:41           ` Dietmar Eggemann
2019-11-04 17:48             ` Vincent Guittot
2019-10-22 20:34 ` [Patch v4 3/6] sched/fair: Enable CFS periodic tick to update " Thara Gopinath
2019-10-28 15:24   ` Peter Zijlstra
2019-10-28 15:27     ` Peter Zijlstra
2019-10-30 21:41     ` Thara Gopinath
2019-10-31 16:11   ` Dietmar Eggemann
2019-10-31 16:46     ` Thara Gopinath
2019-10-22 20:34 ` [Patch v4 4/6] sched/fair: update cpu_capcity to reflect " Thara Gopinath
2019-10-23 12:28   ` Qais Yousef
2019-10-28 15:30     ` Peter Zijlstra
2019-10-31 10:53       ` Qais Yousef
2019-10-31 15:38         ` Dietmar Eggemann
2019-10-31 15:48           ` Vincent Guittot
2019-10-31 16:17             ` Dietmar Eggemann
2019-10-31 16:31               ` Vincent Guittot
2019-10-31 16:44                 ` Dietmar Eggemann
2019-10-31 16:03         ` Thara Gopinath
2019-10-31 16:56           ` Qais Yousef
2019-10-22 20:34 ` [Patch v4 5/6] thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping Thara Gopinath
2019-10-28 15:33   ` Peter Zijlstra
2019-10-31 16:29   ` Dietmar Eggemann
2019-10-31 16:38     ` Vincent Guittot [this message]
2019-11-01 15:47       ` Ionela Voinescu
2019-11-01 21:04         ` Thara Gopinath
2019-11-04 14:41           ` Ionela Voinescu
2019-10-31 16:46     ` Thara Gopinath
2019-10-22 20:34 ` [Patch v4 6/6] sched: thermal: Enable tuning of decay period Thara Gopinath
2019-10-28 15:42   ` Peter Zijlstra
2019-11-04 16:12   ` Ionela Voinescu
2019-11-05 20:26     ` Thara Gopinath
2019-11-05 21:29       ` Ionela Voinescu
2019-10-29 15:34 ` [Patch v4 0/6] Introduce Thermal Pressure Daniel Lezcano
2019-10-31 10:07   ` Ionela Voinescu
2019-10-31 11:54     ` Daniel Lezcano
2019-10-31 12:57       ` Ionela Voinescu
2019-10-31 17:48         ` Daniel Lezcano
2019-10-31  9:44 ` Ionela Voinescu
2019-10-31 16:41   ` Thara Gopinath
2019-10-31 16:52     ` Thara Gopinath
2019-11-05 21:04     ` Ionela Voinescu

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=CAKfTPtCpZq61gQVpATtTdg5hDA+tP4bF6xPMsvHYUMoY+H-6FQ@mail.gmail.com \
    --to=vincent.guittot@linaro.org \
    --cc=amit.kachhap@gmail.com \
    --cc=daniel.lezcano@linaro.org \
    --cc=dietmar.eggemann@arm.com \
    --cc=edubezval@gmail.com \
    --cc=ionela.voinescu@arm.com \
    --cc=javi.merino@kernel.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=mingo@redhat.com \
    --cc=peterz@infradead.org \
    --cc=qperret@google.com \
    --cc=rui.zhang@intel.com \
    --cc=thara.gopinath@linaro.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).